Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Performance analysis and comparison of data-driven models for predicting indoor temperature in multi-zone commercial buildings

Building thermal models, which characterize the properties of a building’s envelope and thermal mass, are essential for accurate indoor temperature and cooling/heating demand prediction. Because of their flexibility and ease of use, data-driven models are increasingly used. Here, this study compared and analyzed the performance of gray-box (resistance-capacitance) and black-box (recurrent neural network) models for predicting indoor air temperature in a real multi-zone commercial building. The developed resistance-capacitance model served as a benchmark model for which full sets of temporal data and building information were used as inputs. The recurrent neural network models were trained and tested assuming various available types and amounts of temporal data and known building physical information to investigate the effects of data and information availability. Feature importance analysis was conducted to select the key variables for different prediction targets under different scenarios. This research provides guidance in selecting an appropriate building thermal response modeling method based on the measured data availability, building physical information, and application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance analysis and optimization for scalable deployment of deep learning models for country-scale settlement mapping on Titan supercomputer

Here, we present a scalable object detection workflow for detecting objects, such as settlements, from remotely sensed (RS) imagery. We have successfully deployed this workflow on Titan supercomputer and utilized it for the task of mapping human settlement at a country scale. The performance of various stages in the workflow was analyzed before making it operational. The workflow implemented various strategies to address issues such as suboptimal resource utilization and long-tail effects due to unbalanced image workload, data loss due to runtime failures, and maximum wall-time constraints imposed by Titan's job scheduling policy. A mean shift clustering–based static load balancing strategy was implemented, which partitions the image load such that each partition contained similar-sized images. Furthermore, a checkpoint-restart strategy was added in the workflow as a fault-tolerance mechanism to prevent the data losses due to unforeseen runtime failures. The performance of the above-mentioned strategies was observed in various scenarios, such as node failure, exceeding wall time, and successful completion. Using this workflow, we have examined an RS data set that has a spatial resolution of 0.31 m and is comprised of 685 675 km 2 of area of the Republic of Zambia in under six hours using 5426 nodes of the Titan supercomputer.

97 MATHEMATICS AND COMPUTING↗

Thermal Performance Analysis of a Geologic Borehole Repository

The Brazilian Nuclear Research Institute (IPEN) proposed a design for the disposal of Disused Sealed Radioactive Sources (DSRS) based on the IAEA Borehole Disposal of Sealed Radioactive Sources (BOSS) design that would allow the entirety of Brazil’s inventory of DSRS to be disposed in a single borehole. The proposed IPEN design allows for 170 waste packages (WPs) containing DSRS (such as Co-60 and Cs-137) to be stacked on top of each other inside the borehole. The primary objective of this work was to evaluate the thermal performance of a conservative approach to the IPEN proposal with the equivalent of two WPs and two different inside configurations using Co-60 as the radioactive heat source. The current WP configuration (heterogeneous) for the IPEN proposal has 60% of the WP volume being occupied by a nuclear radioactive heat source and the remaining 40% as vacant space. The second configuration (homogeneous) considered for this project was a homogeneous case where 100% of the WP volume was occupied by a nuclear radioactive heat source. The computational models for the thermal analyses of the WP configurations with the Co-60 heat source considered three different cooling mechanisms (conduction, radiation, and convection) and the effect of mesh size on the results from the thermal analysis. The results of the analyses yielded maximum temperatures inside the WPs for both of the WP configurations and various mesh sizes. The heterogeneous WP considered the cooling mechanisms of conduction, convection, and radiation. The temperature results from the heterogeneous WP analysis suggest that the model is cooled predominantly by conduction with effect of radiation and natural convection on cooling being negligible. From the thermal analysis comparing the two WP configurations, the results suggest that either WP configuration could be used for the design. The mesh sensitivity results verify the meshes used, and results obtained from the thermal analyses were close to being independent of mesh size. The results from the computational case and analytically-calculated case for the homogeneous WP in benchmarking were almost identical, which indicates that the computational approach used here was successfully verified by the analytical solution.

07 ISOTOPE AND RADIATION SOURCES↗

Performance analysis of novel thermal storage integrated heat pump system in a residential building at the hot climate for demand flexibility

A novel thermal energy storage integrated heat pump system was proposed to reshape the electricity load profile of residential buildings while maintaining thermal comfort. High-fidelity computer simulations are needed for evaluating the feasibility of the proposed system. This study investigates the annual performance of the proposed system through Modelica-based system simulations. A rule-based control strategy was developed to shift the electric demand of a typical single-family house in Atlanta, GA from peak to off-peak hours to utilize the Time-of-Use electricity rate to lower the energy costs for conditioning the building. For comparison, a conventional air-source heat pump system serving the same building was also developed. Simulation results indicate that the proposed system is capable of shifting around 90% of the building's electricity consumption for meeting the thermal demand from peak to off-peak hours on a daily basis. In addition, the annual power consumption and operating cost for running the HVAC system can be reduced by 6% and 34%, respectively, compared with the conventional air-source heat pump.

Shi, Liang↗

Dynamic performance analysis of two regional Nuclear Hybrid Energy Systems

In support of more efficient utilization of clean energy generation sources, including renewable and nuclear options, hybrid energy systems (HES) can be designed and operated as flexible energy resources (FER) to meet both electrical and thermal energy needs in the electric grid and industrial sectors. These conceptual systems could effectively and economically be utilized, for example, to manage the increasing levels of dynamic variability and uncertainty introduced by variable energy resources (VER) such as renewable sources (e.g., wind, solar), distributed energy resources, demand response schemes, and modern energy demands (e.g., electric vehicles) with their ever changing usage patterns. HES typically integrate multiple energy inputs (e.g., nuclear and renewable generation) and multiple energy outputs (e.g., electricity, gasoline, fresh water) using complementary energy conversion processes. This work reports a preliminary dynamic analysis of two realistic HES including a nuclear reactor as the main baseload heat generator and to assess the local (e.g., HES owners) and system (e.g., the electric grid) benefits attainable by their application in scenarios with multiple commodity production and high renewable penetration. It is performed for regional cases - not generic examples - based on available resources, existing infrastructure, and markets within the selected regions. This study also briefly addresses the computational capabilities developed to conduct such analyses.

24 POWER TRANSMISSION AND DISTRIBUTION↗

THERMAL PERFORMANCE ANALYSIS FOR SMALL ION-EXCHANGE CESIUM REMOVAL PROCESS

The In-Riser Ion Exchange program focuses on the development of in-tank systems to decontaminate high level waste (HLW) salt solutions at the Savannah River Site (SRS) and the Hanford Site. Small Column Ion Exchange (SCIX) treatment for cesium removal is a primary in-riser technology for decontamination prior to final waste immobilization in Saltstone. Through this process, radioactive cesium from the salt solution is adsorbed onto the ion exchange media which is packed within a flow-through column. Spherical Resorcinol-Formaldehyde (RF) is being considered as the ion exchange media for the application of this technology at both sites. A packed column loaded with media containing radioactive cesium generates significant heat from radiolytic decay. Under normal operating conditions, process fluid flow through the column can provide adequate heat removal from the columns. However, in the unexpected event of loss of fluid flow or fluid drainage from the column, the design must be adequate to handle the thermal load to avoid unacceptable temperature excursions. Otherwise, hot spots may develop locally which could degrade the performance of the ion-exchange media or the temperature could rise above column safety limits. Data exists which indicates that performance degradation with regard to cesium removal occurs with RF at 65C. In addition, the waste supernate solution will boil around 130C. As a result, two temperature limits have been assumed for this analysis. An additional upset scenario was considered involving the loss of the supernate solution due to inadvertent fluid drainage through the column boundary. In this case, the column containing the loaded media could be completely dry. This event is expected to result in high temperatures that could damage the column or cause the RF sorbent material to undergo undesired physical changes. One objective of these calculations is to determine the range of temperatures that should be evaluated during testing with the RF media. Although, the safety temperature limit is based on the salt solution boiling point which does not apply in the air-filled case (because there is no liquid), this same limit (130C) is used as a measure for the evaluation of this condition as well. The primary objective of the present work is to develop models to simulate the thermal performance of the RF column design when the media is fully loaded with radioactive cesium and the central cooling tube is excluded. Previous analysis led to the consideration of this design simplification for RF, since the baseline column design with center cooling was developed assuming that CST media would be used for cesium removal which has a higher volumetric heat load. Temperature distributions and maximum temperatures across the column during SCIX process operations and upset conditions were conducted with a focus on SCIX implementation at Hanford. However, a feed composition and cesium loading were assumed which were known to be considerably higher than would typically be observed at Hanford. In order to evaluate the impact of this potentially highly conservative assumption, fractionally-reduced loading cases were also considered. A computational modeling approach was taken to include conservative, bounding estimates for key parameters so that the results would provide the maximum temperatures achievable under the design configurations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance analysis of hybrid power configurations: Impact on primary energy intensity, carbon dioxide emissions, and life cycle costs

In this work, utilization of Natural gas and Hydrogen to support current and future building energy needs to offset the total electric demand while improving the grid resiliency and energy efficiency was investigated. Demand side energy management will play an important role in efficiently managing the available energy resources. Performance assessment of different power generation and energy management configurations is presented in this paper. Development of solutions in addressing grid resiliency by providing the ability to design suitable configurations for meeting individual building energy needs is discussed. Primary movers (PM) such as internal combustion engines (ICE) and fuel cells (FC) along with small scale auxiliary renewable energy source such as photovoltaics (PV) were considered. Key attributes of total carbon foot-print, life cycle costs including capital and operational expenditure, electric grid offset or peak shaving capability, thermal energy availability and its further potential to offset total electric demand, and primary energy intensity are analyzed and discussed in detail.

08 HYDROGEN↗

Performance Analysis of Transposition Models Simulating Solar Radiation on Inclined Surfaces: Preprint

Transposition models are widely used in the solar energy industry to simulate solar radiation on inclined photovoltaic (PV) panels. These transposition models have been developed using various assumptions about the distribution of the diffuse radiation, and most of the parameterizations in these models have been developed using hourly ground data sets. Numerous studies have compared the performance of transposition models, but this paper aims to understand the quantitative uncertainty in the state-of-the-art transposition models and the sources leading to the uncertainty using high-resolution ground measurements in the plane of array. Our results suggest that the amount of aerosol optical depth can affect the accuracy of isotropic models. The choice of empirical coefficients and the use of decomposition models can both result in uncertainty in the output from the transposition models. It is expected that the results of this study will ultimately lead to improvements of the parameterizations as well as the development of improved physical models.

14 SOLAR ENERGY↗

Energy performance analysis of smart wall system with switchable insulation and thermal storage capacity

The ever-increasing global energy demand and the issues caused by population growth and unsustainable energy resource usages have several environmental and economic impacts. The on-demand capability of dynamic wall systems with switchable insulation systems can contribute toward energy efficiency and reduced electric cost using "building-as-a-battery." In this paper, the performance of an exterior envelope system that employs a switchable insulation system is investigated. A COMSOL simulation was used to study the envelope performance under three switchable insulation locations in the wall system. The on and off switching cycle included insulating or conducting the exterior, interior, or both sides of the mass wall system. To validate the simulation work, an experimental test was conducted in climate chamber on a 4 × 8 in. wall system with identical wall components used in the COMSOL simulation. Results show a good agreement between the experiment and simulation results. The wall system with switchable insulation placed on the exterior side provided the highest interior inward heat flux when compared with the interior or split insulation. Also, an exterior switchable insulation system in addition to a thermal mass maintained a positive heat flow for more hours when the outdoor temperature was lower than the interior temperature.

Iffa, Emishaw↗

Performance Analysis and Simulaion of the Hydraulic Scram System in TREAT Reactor

The Transient Reactor Test Facility (TREAT) at Idaho National Laboratory (INL) serves a vital role in nuclear fuel safety research, enabling transient experiments that simulate reactivity excursions and accident scenarios. Central to these operations is the transient control rod drive system (TCRDS), which drives rapid motion of the transient control rods such that TREAT can simulate rapid power changes typical of reactor accidents. The reliability and performance of this system are critical for protecting both fuel specimens and reactor infrastructure. This study presents the initial phase of a two-year investigation into the dynamics and reliability of the TREAT hydraulic TCRDS. Conducted in collaboration with INL, the research employs a combined computational and experimental approach to analyze the system's response time, pressure transients, and potential failure modes. Emphasis is placed on understanding how fluid characteristics influence the TCRDS’s ability to achieve both rapid power changes and mechanical stability. The TRDS and the skid that powers it will be analyzed throughout this investigation. Computational modeling using computational fluid dynamics (CFD) will simulate the hydraulic response under varying conditions. In parallel, experimental testing planned at INL will validate these models and capture key performance metrics. This paper outlines the system design, analytical framework, and modeling strategies that form the foundation for later testing. Ultimately, this work aims to support improvements to the TCRDS’s design and reliability, contributing to the broader goal of enhancing nuclear fuel safety and sustaining TREAT’s mission as a premier nuclear fuel test facility.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Performance Analysis and Limiting Parameters of Cross-flow Membrane-based Liquid-desiccant Air Dehumidifiers

We report that to dehumidify a humid air stream, existing air conditioning (AC) systems substantially overcool the outdoor humid air below its dew point, thereby significantly reducing energy efficiency. Directly capturing humidity, membrane-based liquid-desiccant dehumidification systems separate sensible and latent cooling (SSLC) loads and thus offer a promising pathway for a high-performance AC solution. Design of an energy-efficient SSLC-AC system, however, rests largely on detailed understating of the dehumidification process. While some studies have identified the dehumidification process mainly depends on membrane characteristics, other studies have argued that the process is limited by desiccant liquid or alternatively air thermo-hydraulic physics for typical humid climate conditions. The present study examines performance and physics of the membrane-based liquid-desiccant dehumidification process over a wide range of climate conditions through a novel 3D, two-phase, multi-species CFD model. Decoupling the thermodynamic and hydraulic effects, the study reveals that the dehumidification rate is a linear function of the water vapor pressure potential ($J=α ΔP$) summarizing the system's thermodynamic state. The slope of the curve (i.e., α) depends on hydraulic transport characteristics of the membrane pores, air stream, and desiccant solution. More importantly, it was found that the air dehumidification process is mainly limited by the air-side transport physics for thin liquid-desiccant films and commonly used porous superhydrophobic membranes. Additionally, results show that, depending on ambient/desiccant conditions and physical dehumidifier characteristics, energy effectiveness and dehumidification rate vary from 13 to 34% and from 0.13 to 1.4 g m -2 s -1 , respectively. Therefore, the present study allows to efficiently design future SSLC-based AC systems exhibiting high performance energy metrics.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Nonlinear modeling and performance analysis of cracked beam microgyroscopes

Cracks constitute a common structural defect in microelectromechanical systems that may arise during manufacturing, mechanical fatigue, or shock loading. Areas weakened by cracks increase the flexibility of the microstructure. Furthermore, depending on the crack severity, the increased flexibility can cause dramatic changes in the static and dynamic behaviors of electrically actuated MEMS. In this study, a numerical investigation of the depth and location of multiple edge cracks on the performance of beam microgyroscopes is conducted. Applying the Griffith strain energy release theorem for an edge crack, the vibrational characteristics of microgyroscopes with multiple cracks including the static deflection, natural frequencies, and mode shapes are studied analytically. Then, the differential quadrature method is employed to model the nonlinear dynamic behaviors of the cracked gyroscope system. Cracks initiated along the driving or sensing directions of the microgyroscope are found to have differing effects on its nonlinear dynamic response. This numerical study reveals that the onset of severe single cracks or a series of multiple cracks can significantly affect the sensitivity of the microgyroscope to base rotations and therefore leads to a degradation in the performance of the damaged MEMS sensor. This study also shows that a potential design approach for broadband microgyroscope systems manufactured with cracks can be proposed.

42 ENGINEERING↗

Performance Analysis of Photovoltaic Thermal System Using Silicone Oil Spectrum Filter

The paper reports use of silicone oil as spectrum filter and heat absorber for photovoltaic thermal systems. The terrestrial solar spectrum is in the wavelength range of 0.25 to 2.5 μm. The response range of C-Si solar cell is 0.75 to 1.125 μm. In the current study, the feasibility of Silicone oil (Transformer oil) as spectrum filter cum heat absorber for C-Si solar cell is investigated. The spectroscopic analysis of 1 cm thick Silicone oil sample with UV-VIS-NIR spectrophotometer is carried out. This analysis concludes that the Silicone oil is transparent to the response range of C-Si solar cell. Also, it shows a significant absorption for UV and IR part of the spectrum. A glass container with 1 cm thick Silicone oil layer is mounted on the C-Si PV module. The performance of the system is analyzed using solar simulator at irradiance of 1000 W/m{sup 2}, AM 1.5 G and in natural sunlight at Nagpur (21.10 N, 79.090 E). The experiments were performed for the entire year for time period of one hour in the noon. With Silicone oil spectrum filter, the average electrical efficiency of the PV module was found increase marginally. However, for 10 W module, 27 W average heat gain was recorded. In this study, the surface area of PV module (30 × 35 cm = 0.105 m{sup 2}) was very small. In actual practice, for large scale installations, significant heat gain is possible. The experimentation and significant outcomes are discussed in this article.

14 SOLAR ENERGY↗

Performance analysis of a latent heat storage system with phase change material for new designed solar collectors in greenhouse heating

The continuous increase in the level of greenhouse gas emissions and the rise in fuel prices are the main driving forces behind the efforts for more effectively utilize various sources of renewable energy. In many parts of the world, direct solar radiation is considered to be one of the most prospective sources of energy. In this study, the thermal performance of a phase change thermal storage unit is analyzed and discussed. The storage unit is a component of ten pieced solar air collectors heating system being developed for space heating of a greenhouse and charging of PCM. CaCl{sub 2}6H{sub 2}O was used as PCM in thermal energy storage with a melting temperature of 29 C. Hot air delivered by ten pieced solar air collector is passed through the PCM to charge the storage unit. The stored heat is utilized to heat ambient air before being admitted to a greenhouse. This study is based on experimental results of the PCM employed to analyze the transient thermal behavior of the storage unit during the charge and discharge periods. The proposed size of collectors integrated PCM provided about 18-23% of total daily thermal energy requirements of the greenhouse for 3-4 h, in comparison with the conventional heating device. (author)

14 SOLAR ENERGY↗

Performance Analysis of a Single-phase GaN-based 3L-ANPC Inverter for Photovoltaic Applications

Nowadays, the power electronics converter design is challenged with a request of high efficiency and compactness for various applications. To tackle this, the research community and the industry have almost fully exploited the silicon technology, leading to the development of new power transistors. The Gallium-Nitride (GaN) HEMTs can be promising power devices to replace the traditional power devices. Therefore, the performances of GaN-based converters should be assessed to validate the effectiveness in terms of efficiency and power density. Moreover, among the available converter topologies, the performance of the three-level Neutral Point Clamped (NPC) family can be enhanced with the GaN HEMTs. In light of the above, in this paper, the performance of a GaN-based three-level Active NPC (3L-ANPC) converter is evaluated in terms of power losses, volume impact of passive components, and output distortions. Simulations and experiments have been performed.

Valante, Mauro↗

Performance analysis of emerging data analytics and HPC workloads

Supercomputers are increasingly being used to run a data analytics workload in addition to a traditional simulation science workload. This mixed workload must be rigorously characterized to ensure that appropriately balanced machines are deployed. In this paper we analyze a suite of applications representing the simulation science and data workload at the NERSC supercomputing center. We show how time is spent in application compute, library compute, communication and I/O, and present application performance on both the Intel Xeon and Intel Xeon-Phi partitions of the Cori supercomputer. We find commonality in the libraries used, I/O motifs and methods of parallelism, and obtain similar node-to-node performance for the base application configurations. We demonstrate that features of the Intel Xeon-Phi node architecture and a Burst Buffer can improve application performance, providing evidence that an exascale-era energy-efficient platform can support a mixed workload.

Daley, Christopher S.↗

PERFORMANCE ANALYSIS OF AN ENGINEERING SCALE HYDROTHERMAL LIQUEFACTION SYSTEM

This work evaluates the Modular Hydrothermal Liquefaction System (MHTLS), an engineering-scale, integrated continuous HTL plant operated at the Pacific Northwest National Laboratory (PNNL), for converting realistic wet wastes into energy-dense biocrudes. The production campaigns discussed here processed algae, sewage sludges, lignocellulosic blends, Industrial food waste, and engineered food-waste slurries at 350?°C and around 200?bar, with nominal feed rates of ~12?L?h?¹. We report biocrude yields and composition, establish mass and elemental (C, N) balances, and quantify energy performance via heater duties, heat-exchanger behavior, and system-level efficiencies. Biocrudes contained 76–80?wt?% C (dry, ash-free) with HHVs of 38-41?MJ?kg?¹, substantially higher than feed materials HHVs of 16.6–26.1?MJ?kg?¹ and approaching petroleum fuels. Dry, ash-free biocrude yields of 32–53?wt?% corresponded to 43–71?wt?% carbon yields, with 18–40?wt?% of feed carbon routed to the aqueous phase. Thermal efficiencies were 50-65%, and total energy efficiencies, including reactor heat input, were 35-55%. A counter-current tube-in-tube heat exchanger delivered U values of 200–450?W?m?²?K?¹, with fouling-induced declines impacting heat recovery and heater duty. The analysis highlights three priorities for the process intensification of HTL: robust, fouling-resistant heat recovery, hydrodynamically suitable reactor and heat-exchanger designs, simplified and predictable solids management, and biocrude-water separation.

Biocrude production↗

Performance analysis of higher mode spoof surface plasmon polariton for terahertz sensing

We investigated the spoof surface plasmon polaritons (SSPPs) on 1D grooved metal surface for terahertz sensing of refractive index of the filling analyte through a prism-coupling attenuated total reflection setup. From the dispersion relation analysis and the finite element method-based simulation, we revealed that the dispersion curve of SSPP got suppressed as the filling refractive index increased, which cause the coupling resonance frequency redshifting in the reflection spectrum. The simulated results for testing various refractive indexes demonstrated that the incident angle of terahertz radiation has a great effect on the performance of sensing. Smaller incident angle will result in a higher sensitive sensing with a narrower detection range. In the meanwhile, the higher order mode SSPP-based sensing has a higher sensitivity with a narrower detection range. The maximum sensitivity is 2.57 THz/RIU for the second-order mode sensing at 45° internal incident angle. The proposed SSPP-based method has great potential for high sensitive terahertz sensing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗