Search NASA⌕ Search

SEARCH · Search NASA

Results for “Periodic Heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

MULTIMARKET CONTROL AND OPERATION OF AN ADVANCED NUCLEAR REACTOR WITHIN AN INTEGRATED ENERGY PARK

Integrated energy systems (IES) are increasing in popularity and relevance given the heightened penetration of variable renewable energy sources. This variability is causing traditional baseload generators to reconsider their business cases as exclusively electrical generation stations and to instead consider ancillary products (e.g., hydrogen) to remain competitive in the current energy market. This work investigates the coupling, control, and overall viability of IES consisting of an advanced nuclear reactor coupled with a high-temperature steam electrolysis (HTSE) plant and hydrogen storage. The goal of such IES is to produce hydrogen without impacting reactor operations during periods of off-peak electricity demand and then sell electricity to the grid during periods of high demand. To accomplish this, a novel heat exchanger, control scheme, and coupling strategy were needed to ensure that the advanced nuclear power plant could make these transitions. Idaho National Laboratory’s open-source Framework for Optimization of Resources and Economics (FORCE) framework was used to develop novel coupling and control schemes that demonstrate the viability of multi-market operation of advanced nuclear reactors to produce both electricity and hydrogen. The results demonstrated the coupled IES could operate without impacting reactor systems while monetizing the electricity market and meeting all contractual hydrogen consumer demands.

08 HYDROGEN↗

Multifunctional Heat Pump with Energy Storage Capability

Replacing gas furnaces with heat pumps on a large scale can pose challenges to the electrical grid. It will significantly increase the demand, strain the electrical grid, especially during peak usage times. To ensure that heat pumps contribute to reducing emissions, it's essential to increase the share of renewable energy in the grid. However, the supply of renewable energy is unstable. Large scale of electrification must address the concern of grid resilience to meet necessary heating/cooling demands and shift peak electric load. All these require future heat pumps having energy storage capability. These systems can store excess energy during low-demand periods and release it during high-demand periods, reducing stress on the grid. This paper will introduce an innovative configuration, control, and laboratory investigations of a multifunctional packaged heat pump. In addition to the original indoor and outdoor air coils, the heat pump has a parallel hydronic loop with a brazed plate heat exchanger (BHP). The hydronic loop circulates hot/chilled water to store heating/cooling energy in phase change material (PCM). It is capable of space cooling, space heating, cooling energy storage/defrosting, water heating/heating energy storage with outdoor air source or indoor air source, and cooling/heating energy free discharge. The laboratory studies and breadboard unit are presented. Additionally, building energy simulation demonstrates utility cost reduction potential via charging PCM panels/ceilings during off-peak hours and releasing the energy during peak hours to mitigate the peak power consumption.

Shen, Bo↗

Spins and Heat in Nanoscale Electronic Systems (SHINES) (Final Report)

This project covers the funding period of 08/01/2014-07/31/2020. The project received a no-cost extension for 6 months which ended on 01/31/2021. The overall project is divided into two periods: full funding of $\$3$ million/year with the total of $\$12$ million for the first four years (08/01/2014-07/1/2018); and $\$1.9$ million for the two-year extension (08/01/2018-07/31/2020). During the first four-year period, SHINES supported 14 PIs plus two UCR seed PIs (internally funded). During the 2-year extension, only 7 PIs were involved, and 8 UCR seed PIs were supported using UCR internal funds.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Geospatial coherence of surface-atmosphere fluxes in the upper Great Lakes region

Surface-atmosphere fluxes are known to vary at multiple time scales, but uncertainty is high as to how fluxes change spatially within regions. With an increase in the number of eddy covariance towers, we are now able to examine the geospatial coherence of ecosystem fluxes, using time-series correlation. Eighteen sites from Michigan and Wisconsin were used in this study, ranging from 100 m to 600 km apart. Surface-atmosphere fluxes from a six-month period were used to quantify spatial coherence on a pair-wise basis. Using geospatial statistics, carbon and sensible heat (H) fluxes were found to be 95% correlated directly outside of their flux footprint and 56% correlated up to a distance of ~35 km. Latent (LE) and momentum (τ) fluxes were less correlated, 83% directly outside of their flux footprint and 40% at a distance of ~130 km albeit, at a much larger spatial distance than for the carbon and sensible heat fluxes. All fluxes showed strong spectral resonance at diel and seasonal timescales, with 1-, 2- and 3-month periods being common modes of variability among H, LE, and τ fluxes. Results based on Empirical Orthogonal Function show distinct transitions of net ecosystem exchange from fall to winter before photosynthesis or respiration while H and τ do not exhibit coherent trends. Here, this work demonstrates the potential of quantifying geospatial coherence of surface-atmosphere fluxes in the Midwestern United States, with the ability to predict fluxes beyond the spatial limit of a single flux tower footprint. Ultimately, expanding the flux measurements to larger scales would allow better spatial scaling of terrestrial surface-atmosphere fluxes between tower footprint and modeling or remote sensing scales.

54 ENVIRONMENTAL SCIENCES↗

Revisiting the equatorial Pacific sea surface temperature response to global warming

The relative roles of the oceanic and atmospheric processes in the pattern formation of the equatorial Pacific sea surface temperature (SST) response to global warming is investigated using a set of climate model experiments embedded with a novel partial coupling technique. Here, the modeling results show that the SST response experiences a transition from a La Niña-like warming pattern at the initial stage to an El Niño-like warming pattern at the quasi-equilibrium stage. By decomposing anomalous equatorial Pacific SST into atmosphere-forced passive component and ocean dynamics-induced active component, it is found that the SST warming pattern at both stages is entirely induced by its active component. Specifically, the meridional and vertical ocean circulation changes play a dominant role in forming the La Niña-like SST warming pattern at the initial stage, and the zonal and meridional ocean circulation changes are responsible for the formation of the El Niño-like SST warming pattern at the quasi-equilibrium stage. In contrast, the passive SST at both stages is characterized by a zonally uniform warming along the equator, which can be explained by a balance between the cooling effect associated with mean upwelling and the warming effect due to surface passive heat flux change. In addition, this study finds that it is the slowdown of the Pacific subtropical cells during the transition period that controls the evolution of the equatorial SST warming pattern by changing the meridional and vertical ocean heat transports.

54 ENVIRONMENTAL SCIENCES↗

Two-Way Coupled CFD/DEM Simulation of Electromagnetic Heating in a Fluidized Bed Reactor

A set of tools has been developed to couple a multiphase reacting computational fluid dynamics solver (MFIX) with two computational electromagnetic solvers (COMSOL and Elmer). In contrast to several recent investigations, which calculate a single static EM field prior to the CFD calculation, in the present work the electromagnetic field is periodically updated during the simulation. This enables the EM field and associated EM heating predictions to reflect the effects of evolving material properties (temperature, composition, size etc.) and the evolving distribution of material in the system. The present work uses effective medium theory (EMT) for the electromagnetic field calculations since the goal is to apply the tool for industrial scale reacting systems. Predictions using MFIX/COMSOL and MFIX/Elmer are compared to in bed thermocouple measurements from a fluidized bed experiment and recent simulation predictions and recent experiments performed at NETL. The NETL experiments also include packed bed operating conditions. Coupled MFIX/COMSOL simulations at these conditions are compared with similar simulations using only COMSOL to measure errors due to the solver coupling approach.

CFD↗

Polarized fusion and potential in situ tests of fuel polarization survival in a tokamak plasma

Abstract The use of spin-polarized fusion fuels would provide a significant boost towards the ignition of a burning plasma. The cross section for D + T → α + n, would be increased by 1.5 if the fuels were injected with parallel polarization. Furthermore, our simulations demonstrate additional non-linear power gains in large-scale machines such as ITER, due to increased alpha heating. Such benefits require the survival of spin polarizations for periods comparable to the particle confinement time. During the 1980s, calculations predicted that polarizations could survive a plasma environment, although concerns persisted regarding the cumulative impacts of wall recycling. In that era, technical challenges prevented direct tests and left the large scale fueling of a power reactor beyond reach. Over the last decades, this situation has changed dramatically. Detailed simulations of ITER have predicted negligible wall recycling in a high-power reactor, and recent advances in laser-driven sources project the capability of producing large quantities of ∼100% polarized D and T. The remaining crucial step is an in-situ demonstration of polarization survival in a plasma. For this, we outline a measurement strategy using the isospin-mirror reaction, D + 3 He → α + p. Polarized 3 He avoids the complexities of handling tritium, while encompassing the same spin-physics. We evaluate two methods of delivering deuterium, using dynamically polarized Lithium-Deuteride (with vector polarization P V D of 70%) or frozen-spin Hydrogen-Deuteride (with P V D of 40%), together with a method of injecting optically-pumped 3 He (with 65% polarization). Pellets of these materials all have long polarization decay times (∼6 min for LiD at 2 K, ∼2 months for HD at 2 K, and ∼3 d for 3 He at 77 K), all far greater than a plasma shot in a research tokamak such as DIII-D (∼20 s). Both species can be propelled from a single cryogenic injection gun. We review plasma requirements and strategies for detecting polarization survival. Polarization alters both fusion yields and the angular distribution of fusion products, and each of these provides a potential signal. In this paper we simulate a selection of shots with similar characteristics in a future high-T ion H plasma, and find ratios of yields from shots with fuel spins parallel and antiparallel reaching 1.3 (HD + 3 He) to 1.6 (LiD + 3 He) over a wide range of poloidal angles. (A companion paper finds sensitivity to fusion product angular distributions as reflected in the pitch angles of protons and alphas reaching the plasma facing wall.)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solar Steam on Demand

INTRODUCTION: This Report summarizes the research and development project performed by Sunvapor and the subrecipient National Renewable Energy Laboratory (NREL) during the period of 10/01/2018-9/30/2021. The work was aimed at the economic integration of solar steam with an industrial process, and in particular, the advantages that a novel type of thermal energy storage and collector design could bring to the system. The completed work includes experimental research on the storage material, design of the collector, engineering of a complete solar steam plant, and economic analysis. The plant was, in the end, not constructed, due to COVID-19 impacts to the project host. PURPOSE: The purpose of the project was to test the hypothesis that a levelized cost of heat (LCOH) of 2¢/kWh delivered to a steam-consuming process, including energy discharged from storage, could be feasibly achieved. PROJECT OBJECTIVES: For Budget Period 1 our objectives were to engineer a prototype industrial solar steam generation system, and design and test a Latent Heat Energy Storage (LHES) lab-scale system. For Budget Period 2 our objectives were to construct and test the solar steam prototype plant, and to build and factory-test a full LHES module. For Budget Period 3 our objective was to integrate the storage module with the solar steam generator, show successful long duration energy tests of the combined system, and use the results to project the LCOH of delivered steam to a second-generation plant. PROJECT OUTCOMES: Various phase change materials (PCMs) for the LHES were tested for compatibility with industrial steam uses as measured by phase change temperature, stability of latent heat of fusion, and their corrosive effects on steel (the heat exchanger material). Two of these materials (sodium formate and sodium/ potassium) showed potential to meet the technical criteria. The estimated cost of a complete LHES module with these materials did not meet economic targets. The developmental collector design builds from previous work to exploit the potential cost advantages of a spaceframe of lumber construction. Design improvements were achieved in assembly efficiency and structural performance. A complete engineering package was completed for the solar steam system without storage that included the developmental as well as commercial arrays. The plant was permitted for construction. The storage CAPEX for a reference plant was estimate to be greater than $\$ 57$/kWh. The LCOH of the system without storage and with developmental collectors of lumber construction was projected to be 2¢/kWh, assuming a FCR of 8.2% over thirty years. PROJECT MILESTONES: The Milestones fully achieved in the first Budget Period includes obtaining a Letter of Intent from an industrial steam-consuming project host, issuance of a construction permit, and corrosion resistance. The Milestone that was partly achieved was the degradation in the latent heat of fusion. Milestones associated with Budget Periods 2 and 3, related to the construction and operation of the plant were not achieved as a result of the host shutting down the plant due to COVID-19 impacts. CONCLUSIONS: Sunvapor was able to secure an agreement with a host to build a fully engineered and permitted solar steam plant that met the host’s economic goals. As a basis for comparison, the solar field design was comprised of eight commercial collector arrays and one developmental Green Parabolic Trough Collector (GPTC) array. The projected LCOH with a solar field entirely populated with a second generation GPTC met the goal of 2¢/kWh. The experimental program concerning the PCM indicated the feasibility of meeting their technical requirements for industrial steam uses. The cost of the complete LHES exceeded its $\$ 14$/kWh target, and therefore the inclusion of LHES could not be economically justified. Due to COVID-19 impacts on the host, the solar steam plant was not constructed.

14 SOLAR ENERGY↗

Two-Way Coupled CFD/DEM Simulation of Electromagnetic Heating in a Fluidized Bed Reactor - Extended Abstract

A set of tools has been developed to couple a multiphase reacting computational fluid dynamics solver (MFIX) with two computational electromagnetic solvers (COMSOL and Elmer). In contrast to several recent investigations, which calculate a single static EM field prior to the CFD calculation, in the present work the electromagnetic field is periodically updated during the simulation. This enables the EM field and associated EM heating predictions to reflect the effects of evolving material properties (temperature, composition, size etc.) and the evolving distribution of material in the system. The present work uses effective medium theory (EMT) for the electromagnetic field calculations since the goal is to apply the tool for industrial scale reacting systems. Predictions using MFIX/COMSOL and MFIX/Elmer are compared to in bed thermocouple measurements from a fluidized bed experiment and recent simulation predictions and recent experiments performed at NETL. The NETL experiments also include packed bed operating conditions. Coupled MFIX/COMSOL simulations at these conditions are compared with similar simulations using only COMSOL to measure errors due to the solver coupling approach.

CFD↗

Implementation and validation of optimal start control strategy for air conditioners and heat pumps

Commercial buildings are responsible for approximately 20 % of the total energy consumption and greenhouse gas emissions in the United States. Over 85 % of these buildings lack building automation systems, and many are small (<50,000 square feet), underserved, and use rooftop units (RTUs) for heating, ventilation, and air-conditioning needs. Because these buildings lack proper energy management systems, several operational deficiencies lead to excess energy consumption. Studies have shown that managing the RTUs’ heating and cooling set points, schedules, setbacks, and optimal start can result in a 20 % to 25 % reduction in electricity consumption in small commercial buildings. These buildings typically use fixed schedules to start the RTUs 60 to 120 min before occupancy begins, which results in excess energy consumption. This paper presents research that demonstrates and evaluates the performance of four optimal start methods, which utilize data-based modeling as a key element in facilitating adaptive control in response to time-varying inputs while requiring minimal sensor inputs. The evaluation found energy savings in two commercial buildings equipped with RTUs by periodically alternating four different optimal start models during the cooling and heating season. The resulting energy savings are positive for all models and range from 2 to 5 kWh/day/unit. The units on the east side of the building showed higher savings, while interior units showed greater variability in savings due to the differences in capacities and room sizes. Savings were considerably greater during the heating season compared to the cooling season. The performance of all four models on Mondays was poor; models suggested a shorter optimal start time, which resulted in relatively larger errors. Finally, the future work will look at using a different model for the days after weekends and holidays.

42 ENGINEERING↗

The strong influence of Ti, Zr, Hf solutes and their oxidation on microstructure and performance of Nb 3 Sn superconductors

The strong influence of Ti, Zr, Hf solutes and their oxidation on microstructure and performance of Nb 3 Sn superconductors Over the last few years a new type of Nb 3 Sn superconducting composite based on the internal oxidation approach has emerged and has demonstrated performance significantly superior to conventional Nb 3 Sn. It requires a supply of O and the use of a Nb alloy – Nb-X, where X is a solute element that can be selectively oxidized to form oxide particles within the Nb 3 Sn. Such oxide particles not only refine Nb 3 Sn grain size, but also have the proper size to act as artificial pinning centers (APC) directly restraining fluxon motion, and thus dramatically improve superconducting properties. In this article we show that the size and volume fraction of the oxide particles determine both the levels of grain refinement and the shift in the peak field of the flux pinning force (F p -B) curve. Additionally, we explore the factors influencing these microstructure and properties, which we find include: selection of the solute element X, solute content, O content, and heat treatment. For the selection of X, we searched the periodic table for all promising candidates but focused down on the group-IVB elements (Ti, Zr, Hf) here as the drawability of Nb 3 Sn wires made from Nb-Ti, Nb-Zr, and Nb-Hf alloys has been demonstrated in the past few decades. We found that while internally oxidizing Nb-1.5at.%Ti led to negligible grain refinement and F p -B peak shift, Nb-Zr alloys led to much more dramatic results, and internally oxidizing Nb-Hf alloys led to the strongest grain refinement and F p -B peak shift. For Hf alloying in particular, we compared our internal oxidation method with another method for grain refinement, which uses Hf alloying itself without oxidation, and found that internal oxidation led to much stronger grain refinement and F p -B peak shift. We also found that higher solute content and lower reaction temperature led to stronger grain refinement and F p -B peak shift. We conclude with a discussion of the possible mechanisms for the influence of these factors.

43 PARTICLE ACCELERATORS↗

Ground Heat Flux Reconstruction Using Bayesian Uncertainty Quantification Machinery and Surrogate Modeling

Ground heat flux (G 0 ) is a key component of the land-surface energy balance of high-latitude regions. Despite its crucial role in controlling permafrost degradation due to global warming, G 0 is sparsely measured and not well represented in the outputs of global scale model simulation. In this study, an analytical heat transfer model is tested to reconstruct G 0 across seasons using soil temperature series from field measurements, Global Climate Model, and climate reanalysis outputs. The probability density functions of ground heat flux and of model parameters are inferred using available G 0 data (measured or modeled) for snow-free period as a reference. When observed G 0 is not available, a numerical model is applied using estimates of surface heat flux (dependent on parameters) as the top boundary condition. These estimates (and thus the corresponding parameters) are verified by comparing the distributions of simulated and measured soil temperature at several depths. Aided by state-of-the-art uncertainty quantification methods, the developed G 0 reconstruction approach provides novel means for assessing the probabilistic structure of the ground heat flux for regional permafrost change studies.

54 ENVIRONMENTAL SCIENCES↗

Balancing moisture and oxygen can match the crystallization dynamics of inert halide perovskite processing

Understanding crystallization in ambient environments is essential for scaling the fabrication of halide perovskite solar cells. Antisolvent-free perovskite deposition offers improved compatibility with high-throughput processing but introduces distinct crystallization dynamics relative to the more ubiquitous use of antisolvents in lab-scale perovskite fabrication. These dynamics are driven by interactions between solutes, solvent and the deposition environment. Using in situ wide-angle X-ray scattering during spin-coating and annealing, we demonstrate how relative humidity (RH) and oxygen, can be tuned to drive polytype evolution during ambient crystallization of formamidinium lead iodide to match that of inert synthesis and achieve comparable film and device quality. In an inert (N 2 ) environment, we find that perovskite films follow a well-established 2H → 3C phase transformation with a short period of coexistence of the 4H and 6H phase during heating. During crystallization in dry air (RH 0%), the added presence of oxygen leads to the dominance of 4H intermediate for an extended duration, establishing a 2H → 4H → 3C pathway. Introducing low humidity (RH 10%) suppresses the 4H phase to a short-lived intermediate above 100 °C, facilitating a more direct transition to the desired 3C phase and almost replicating the crystallization behavior observed under inert conditions. Interestingly, films crystallized under RH 10% show a lower onset temperature for the perovskite 3C phase than under N 2 . At higher humidity (RH 40%), the strong interaction of oxygen and moisture with iodoplumbates appears to stabilize higher order polytypes (4H and 6H). Devices fabricated under RH 10% achieve higher efficiency and enhanced stability compared to those produced under inert atmosphere. These findings provide mechanistic insight into crystallization pathways in different environments and provide a framework to transfer processes from inert to ambient conditions. The results highlight the critical role of controlled humidity in tuning antisolvent-free perovskite crystallization for scalable processing.

Hossain, Maimur [Univ. of California, San Diego, C↗

Sequential versus Simultaneous Aging of EPDM Nuclear Cable Insulation Subjected to Elevated Temperature and Gamma Radiation

Electrical cables are integral to power, control, and instrumentation systems within nuclear power plants (NPPs). Exposure of cable systems within nuclear containment to elevated temperatures and gamma radiation during decades-long operation of NPPs can lead to degradation of cable polymeric insulation. Prediction of nuclear cable insulation degradation is complicated as thermal and radiation stress are not additive. In this work, we explore the relative effects of simultaneous and sequential thermal and gamma irradiation on the aging of ethylene-propylene-diene (EPDM) elastomer insulation to better understand realistic scenarios of cable insulation degradation. Cable insulation samples of EPDM were subjected to up to 320 kGy of gamma radiation at a dose rate of 300 Gy/hr in two heating scenarios: (1) simultaneously aged samples were heated at 150°C during irradiation and (2) sequentially aged samples were heated at 150°C for designated durations followed by corresponding periods of irradiation at ambient temperature. The mass, tensile elongation at break, and carbonyl index were assessed to quantify aging of the polymers. The simultaneous aging scenario was found to the more severe of the two for EPDM insulation degradation.

ethylene-propylene-diene elastomer, EPDM, nuclear ↗

Summertime Marine Boundary Layer Cloud, Thermodynamic, and Drizzle Morphology over the Eastern North Atlantic: A Four-Year Study

Abstract Summertime remote sensor and in situ data from 2016 to 2019 collected at the ARM Eastern North Atlantic (ENA) Observatory are combined with aircraft measurements from the Aerosol and Cloud Experiments in the Eastern North Atlantic (ACE-ENA) campaign to quantify marine boundary layer (MBL) cloud, thermodynamic, and drizzle morphology in the region. A radar reflectivity–rainfall rate relationship ( Z – R ) is developed from aircraft data and 6-h cloud morphological regimes are identified from ENA data using a k -means algorithm driven by three independent inputs quantifying cloud thickness, drizzle intensity, and cloud field geometric complexity. Four separate MBL structural regimes representing non- or weakly drizzling single-layer stratocumulus, drizzling stratocumulus and cumulus-coupled stratocumulus, deep convection, and broken clouds embedded in northerly flow are identified. Single-layer stratocumulus is indicated when weak subtropical anticyclones are significantly west of the ENA site, and the MBL is cooler and drier than when drizzling and cumulus-coupled stratocumulus and broken clouds are observed. Drizzling and cumulus-coupled stratocumulus clouds are observed on the eastern flank of strong subtropical anticyclones in deep warm moist air masses with wind speeds exceeding 7 m s −1 and strong near-surface wind shear. Broken clouds exhibit strong wind shear near the inversion, while single-layer stratocumulus clouds have lower wind speeds and minimal shear. Net latent heat fluxes in the subcloud layer resulting from a combination of the ocean surface heat flux and evaporating drizzle average near zero over long periods in drizzling and cumulus-coupled stratocumulus. The ECMWF reanalysis version 5 (ERA5) is found to accurately represent single-layer stratocumulus properties, while producing significant discrepancies when drizzling stratocumulus and cumulus-coupled stratocumulus are observed.

54 ENVIRONMENTAL SCIENCES↗

Development and Evaluation of Occupancy-Aware HVAC Control for Residential Building Energy Efficiency and Occupant Comfort

Occupancy-aware heating, ventilation, and air conditioning (HVAC) control offers the opportunity to reduce energy use without sacrificing thermal comfort. Residential HVAC systems often use manually-adjusted or constant setpoint temperatures, which heat and cool the house regardless of whether it is needed. By incorporating occupancy-awareness into HVAC control, heating and cooling can be used for only those time periods it is needed. Yet, bringing this technology to fruition is dependent on accurately predicting occupancy. Non-probabilistic prediction models offer an opportunity to use collected occupancy data to predict future occupancy profiles. Smart devices, such as a connected thermostat, which already include occupancy sensors, can be used to provide a continually growing collection of data that can then be harnessed for short-term occupancy prediction by compiling and creating a binary occupancy prediction. Real occupancy data from six homes located in Colorado is analyzed and investigated using this occupancy prediction model. Results show that non-probabilistic occupancy models in combination with occupancy sensors can be combined to provide a hybrid HVAC control with savings on average of 5.0% and without degradation of thermal comfort. Model predictive control provides further opportunities, with the ability to adjust the relative importance between thermal comfort and energy savings to achieve savings between 1% and 13.3% depending on the relative weighting between thermal comfort and energy savings. In all cases, occupancy prediction allows the opportunity for a more intelligent and optimized strategy to residential HVAC control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radial Deconsolidation Leach-Burn-Leach of Five AGR-3/4 TRISO Fuel Compacts after Post-Irradiation Heating Tests

Five AGR-3/4 fuel compacts were previously heated in the Fuel Accident Condition Simulator (FACS) furnace. Three of these compacts were also reirradiated in the Neutron Radiography (NRAD) reactor before the FACS tests. One of these was heated to 1200°C, two were heated to 1400°C, one was heated to 1600°C, and one was held for a period of time at 1600 and 1700°C. After these FACS tests, the compacts were subjected to destructive post-irradiation examination (PIE) via radial-deconsolidation-leach-burn-leach (RDLBL) at INL. The RDLBL process deconsolidated the compacts in multiple radial steps, followed by a final, single-step axial deconsolidation. The samples generated at each step were analyzed for isotopes of key fission products and actinides. After each deconsolidation step, the compact volume was assessed, and this was used to normalize the measured quantities of nuclides of interest to give volumetric concentrations as a function of radial position within the compact. The total inventories of measured fission products and actinides and the radial concentration profiles were compared with their sibling compacts within the same capsule (similar irradiation conditions) that went through RDLBL in the as-irradiated state. These data will be used to refine the fission product transport models.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Techno-economic feasibility of borehole thermal energy storage system connected to geothermal heat pumps for seasonal heating load of two buildings in Fairbanks, Alaska

Borehole thermal energy storage (BTES) is an effective solution for managing imbalanced heating and cooling loads in cold regions. This study evaluated the long-term feasibility of a BTES system in the Fairbanks area, Alaska, through building energy modeling, resource characterization, and numerical modeling. The system was designed to store waste heat from a nearby coal power plant during summer and provide thermal energy during winter to geothermal heat pumps supplying heating loads in two buildings. Heating load profiles were modeled for the buildings using EnergyPlus, and the results indicated the annual heating load was 5.6 times greater than the cooling load. 40 borehole heat exchangers were pre-designed approximately 100 m away from the two buildings in terms of land availability and regulatorily optimized depth. The 20-year performance of the designed BTES system under two operational scenarios—one with a 5-year preheating period and one without—was numerically modeled using subsurface temperature and properties characterized through the literature review and thermal response tests. Both scenarios demonstrated that the BTES has the capacity to fully cover the heating loads in the two buildings throughout the 20-year lifetime. Production temperatures at central wells were 33 % higher on average than at outer wells in both scenarios. The 5-year preheating period increased subsurface and extraction temperatures, and correspondingly annual average and total thermal energy production was higher for 8 years than in the scenario without the preheating period. These results highlight the long-term reliability and sustainability of the BTES system in meeting heating demands over its lifetime, with the preheating period offering potential performance improvements. Implementing the BTES system in cold regions with high heating demand, such as Fairbanks, Alaska, could provide a long-term, sustainable energy solution for managing imbalanced heating and cooling loads.

15 GEOTHERMAL ENERGY↗