Search NASA⌕ Search

SEARCH · Search NASA

Results for “Phase shift”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

High dimensional binary classification under label shift: phase transition and regularization

Label Shift has been widely believed to be harmful to the generalization performance of machine learning models. Researchers have proposed many approaches to mitigate the impact of the label shift, e.g., balancing the training data. However, these methods often consider the underparametrized regime, where the sample size is much larger than the data dimension. The research under the overparametrized regime is very limited. Here, to bridge this gap, we propose a new asymptotic analysis of the Fisher Linear Discriminant classifier for binary classification with label shift. Specifically, we prove that there exists a phase transition phenomenon: Under certain overparametrized regime, the classifier trained using imbalanced data outperforms the counterpart with reduced balanced data. Moreover, we investigate the impact of regularization to the label shift: The aforementioned phase transition vanishes as the regularization becomes strong.

binary classification↗

Phase-sensitive optical coherence reflectometer with differential phase-shift keying of probe pulses

We report a new method for reconstructing the signal shape of the external dynamic perturbations along the entire length of the fibre of an optical coherence reflectometer. The method proposed is based on differential phase-shift keying of a probe pulse and demodulation of scattered light by the phase diversity technique. Possibilities of the method are demonstrated experimentally. (fibre-optic sensors)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scattering phase-shift formulas for mesons and baryons in elongated boxes

We derive Lüscher phase-shift formulas for two-particle states in boxes elongated in one of the dimensions. Such boxes offer a cost-effective way of varying the relative momentum of the particles. Boosted states in the elongated direction, which allow wider access to energies, are also considered. The formulas for the various scenarios (moving and zero-momentum states in cubic and elongated boxes) are compared, and relations between them are clarified. The results are applicable to a wide set of meson-meson and meson-baryon elastic scattering processes, with the two-particle system having equal or unequal masses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cavity Attenuated Phase Shift (CAPS) Monitor Instrument Handbook

The CAPS PMex monitor is a cavity attenuated phase shift extinction instrument. It operates as an optical extinction spectrometer, using a visible-light-emitting diode (LED) as the light source, a sample cell incorporating two high-reflectivity mirrors centered at the wavelength of the LED, and a vacuum photodiode detector. Its efficacy is based on the fact that aerosols are broadband scatterers and absorbers of light.

54 ENVIRONMENTAL SCIENCES↗

Application of ANFIS to Phase Estimation for Multiple Phase Shift Keying

The paper discusses a novel use of Adaptive Neuro-Fuzzy Inference Systems (ANFIS) for estimating phase in Multiple Phase Shift Keying (M-PSK) modulation. A brief overview of communications phase estimation is provided. The modeling of both general open-loop, and closed-loop phase estimation schemes for M-PSK symbols with unknown structure are discussed. Preliminary performance results from simulation of the above schemes are presented.

Drake, Jeffrey T.↗

Supersymmetry-generated jost functions and nucleon–nucleon scattering phase shifts

By exploiting the supersymmetry-inspired factorization method higher partial wave Jost solutions and functions for nuclear Hulthen potential are constructed from the knowledge of the ground state wave function. As a case study the nucleon–nucleon scattering phase shifts are computed for partial waves ℓ = 0, 1, and 2.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-energy heavy-ion scattering and the optical phase shift function

Within the framework of the Glauber approximation, an exact expression for the optical phase shift function is derived which takes into account the center-of-mass correlation function. We calculate total and differential cross sections using the first-order term for the shift function and compare them with the usual (first-order) optical limit results and, for the lighter nuclei, with the exact Glauber results. The nucleus-nucleus elastic scattering amplitude does not exhibit the large-q divergence which characterizes the usual optical limit. The obtained results improve the calculated total and differential cross sections dramatically for light nuclei, and significantly for medium and heavy nuclei.

Franco, V.↗

Measurement and Calibration of PSD with Phase-shifting Interferometers

We discuss the instrumental aspects affecting the measurement accuracy when determining PSD with phase shifting interferometers. These include the source coherence, optical train effects, and detector effects. The use of a carefully constructed calibration standard will also be discussed. We will end with a recommended measurement and data handling procedure.

Lehan, J. P.↗

Mathematical simulation of an experimental prototype of a high-speed nonreturn-to-zero differential phase-shift-keying fibre-optic communication system

The influence of chromatic dispersion, optical power, and nonlinear distortions in a fibre-optic communication system on the quality of data transmission based on nonreturn-to-zero differential phase-shift keying at a rate of 40 Gbit s{sup -1} in one spectral channel have been numerically simulated and experimental studied. The results of direct numerical calculations and estimates based on the quality factor (Q factor) are in qualitative agreement with the experimental data. It is found experimentally that the dependence of the error rate on the accumulated dispersion has a plateau in the range from -50 to 50 ps nm{sup -1}; a similar dependence is obtained in the numerical calculation based on the Q factor. The optimal calculated value of the power launched into each of 10 sections of a line with a total length of 1000 km is 2 - 4 dBm; it corresponds to the experimental value of 3 dBm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low energy scattering phase shifts for meson-baryon systems

Here, in this work, we calculate meson-baryon scattering phase shifts in four channels using lattice QCD methods. From a set of calculations at four volumes, corresponding to spatial sizes of 2, 2.5, 3, and 4 fm, and a pion mass of 𝑚 𝜋 ∼ 390 MeV, we determine the scattering lengths and effective ranges for these systems at the corresponding quark masses. We also perform the calculation at a lighter quark mass, 𝑚 𝜋 ∼ 230 MeV, on the largest volume. Using these determinations, along with those in previous work, we perform a chiral extrapolation of the scattering lengths to the physical point after correcting for the effective range contributions using the multivolume calculations performed at 𝑚 𝜋 ∼ 390 MeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Voltage-controlled attenuator with low phase shift

Five megahertz RF (radiofrequency) signal attenuator utilizing RF quadrature hybrid, and optically viable-resistance load controlled by lamp circuit exhibits little phase shift. Circuit is designed to help distribute standard RF signal of controlled amplitude, and phase throughout complex of facilities could be useful in application to precision test equipment and communication electronics.

Lutes, G. F., Jr.↗

Shot-noise-limited measurement of sub-parts-per-trillion birefringence phase shift in a high-finesse cavity

We report on a promising approach to high-sensitivity anisotropy measurements using a high-finesse cavity locked by optical feedback to a diode laser. We provide a simple and effective way to decouple the weak anisotropy of interest from the inherent mirror's birefringence whose drift may be identified as the key limiting parameter in cavity-based techniques. We demonstrate a shot-noise-limited phase shift resolution previously inaccessible in an optical cavity, readily achieving the state-of-the-art level of 3x10{sup -13} rad.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact instantaneous phase-shifting Sagnac interferometer for nanoscale tilt measurement

There is a large inter disciplinary need for high precision angular sensors in state-of-the-art technologies. This particularly applies to optical metrology in the field of Extreme Ultraviolet (EUV) or X-ray where the optics are commonly characterized in terms of slope errors at a nanoradian scale level. Here, in this paper, we present the in-lab development of an angular sensor based on a single reflection compact Sagnac interferometer using instantaneous phase shifting. Our automated prototype and first results show less than 15 nrad RMS repeatability, at least 200 nrad sensitivity and 280 nrad reproducibility over 100 μrad angular range.

36 MATERIALS SCIENCE↗