Search NASA⌕ Search

SEARCH · Search NASA

Results for “Photon Acceleration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Microscopy X-ray imaging enriched with small angle X-ray scattering for few nanometer resolution reveals shock waves and compression in intense short pulse laser irradiation of solids

Understanding how laser pulses compress solids into high-energy-density states requires diagnostics that simultaneously resolve macroscopic geometry and nanometer-scale structure. Here we present a combined X-ray imaging (XRM) and small-angle X-ray scattering (SAXS) approach that bridges this diagnostic gap. Using the Matter in Extreme Conditions end station at LCLS, we irradiated 25 μm copper wires with 45 fs, 0.9 J, 800 nm pulses at 3.5 × 10 19 W/cm 2 while probing with 8.2 keV XFEL pulses. XRM visualizes the evolution of ablation, compression, and inward-propagating fronts with ∼ 200 nm resolution, while SAXS quantifies their nanometer-scale sharpness via the time-resolved evolution of scattering streaks. The joint analysis reveals that an initially smooth compression steepens into a nanometer-sharp shock front after t sh ≈ (18 ± 3) ps, consistent with an analytical steepening model and hydrodynamic simulations. The front reaches a velocity of c sh ≈ 25 k m / s and a lateral width of several tens of microns, demonstrating direct observation of shock formation and decay at solid density for the first time with few-nanometer precision. This integrated XRM–SAXS method establishes a quantitative, multi-scale diagnostic of laser-driven shocks in dense plasmas relevant to inertial confinement fusion, warm dense matter, and planetary physics.

Kluge, Thomas [Helmholtz-Zentrum Dresden-Rossendor↗

Application of Superconducting Cavities as Ultra-Sensitive RF Photon Detectors

Superconducting radio frequency (SRF) cavities are the world’s most efficient engineered oscillators, and they have long been employed for extremely high efficiency transfer of energy to beams of charged particles. Decades of R&D for particle accelerators have led to modern treatments for SRF cavities that achieve higher performance than was previously possible. Advanced SRF cavities using particle accelerator technology are now being used to search for new physics, including dark matter and gravitational waves. The extremely high Q makes it possible to search for very small signals from photons in the radio frequency range, and the extremely high electric fields makes it possible to perform experiments that involve pumping one mode of a cavity in order to search for power transfer mediated by new physics. This talk will present novel experiments that employ SRF cavities, including searches for axions and dark photons dark matter, light-shining-through-walls, and high frequency gravitational waves. Results to be presented include searches with world record sensitivity.

43 PARTICLE ACCELERATORS↗

Selecting XFEL single-particle snapshots by geometric machine learning

A promising new route for structural biology is single-particle imaging with an X-ray Free-Electron Laser (XFEL). This method has the advantage that the samples do not require crystallization and can be examined at room temperature. However, high-resolution structures can only be obtained from a sufficiently large number of diffraction patterns of individual molecules, so-called single particles. Here, we present a method that allows for efficient identification of single particles in very large XFEL datasets, operates at low signal levels, and is tolerant to background. This method uses supervised Geometric Machine Learning (GML) to extract low-dimensional feature vectors from a training dataset, fuse test datasets into the feature space of training datasets, and separate the data into binary distributions of “single particles” and “non-single particles.” As a proof of principle, we tested simulated and experimental datasets of the Coliphage PR772 virus. We created a training dataset and classified three types of test datasets: First, a noise-free simulated test dataset, which gave near perfect separation. Second, simulated test datasets that were modified to reflect different levels of photon counts and background noise. These modified datasets were used to quantify the predictive limits of our approach. Third, an experimental dataset collected at the Stanford Linear Accelerator Center. The single-particle identification for this experimental dataset was compared with previously published results and it was found that GML covers a wide photon-count range, outperforming other single-particle identification methods. Moreover, a major advantage of GML is its ability to retrieve single particles in the presence of structural variability.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Visualizing plasmons and ultrafast kinetic instabilities in laser-driven solids using X-ray scattering

Ultra-intense lasers that ionize atoms and accelerate electrons in solids to near the speed of light can lead to kinetic instabilities that alter the laser absorption and subsequent electron transport, isochoric heating, and ion acceleration. These instabilities can be difficult to characterize, but X-ray scattering at keV photon energies allows for their visualization with femtosecond temporal resolution on the few nanometer mesoscale. Here, we perform such experiment on laser-driven flat silicon membranes that shows the development of structure with a dominant scale of 60 nm in the plane of the laser axis and laser polarization, and 95 nm in the vertical direction with a growth rate faster than 0.1 fs -1 . Combining the XFEL experiments with simulations provides a complete picture of the structural evolution of ultra-fast laser-induced plasma density development, indicating the excitation of plasmons and a filamentation instability. Particle-in-cell simulations confirm that these signals are due to an oblique two-stream filamentation instability. These findings provide new insight into ultra-fast instability and heating processes in solids under extreme conditions at the nanometer level with possible implications for laser particle acceleration, inertial confinement fusion, and laboratory astrophysics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Initial Steps Towards a Clinical FLASH Radiotherapy System: Pediatric Whole Brain Irradiation with 40 MeV Electrons at FLASH Dose Rates

In this work, we investigated the delivery of a clinically acceptable pediatric whole brain radiotherapy plan at FLASH dose rates using two lateral opposing 40-MeV electron beams produced by a practically realizable linear accelerator system. The EGSnrc Monte Carlo software modules, BEAMnrc and DOSXYZnrc, were used to generate whole brain radiotherapy plans for a pediatric patient using two lateral opposing 40-MeV electron beams. Electron beam phase space files were simulated using a model of a diverging beam with a diameter of 10 cm at 50 cm SAD (defined at brain midline). The electron beams were collimated using a 10-cm-thick block composed of 5 cm of aluminum oxide and 5 cm of tungsten. For comparison, a 6-MV photon plan was calculated with the Varian AAA algorithm. Electron beam parameters were based on a novel linear accelerator designed for the PHASER system and powered by a commercial 6-MW klystron. Calculations of the linear accelerator's performance indicated an average beam current of at least 6.25 µA, providing a dose rate of 115 Gy/s at isocenter, high enough for cognition-sparing FLASH effects. The electron plan was less homogenous with a homogeneity index of 0.133 compared to the photon plan's index of 0.087. Overall, the dosimetric characteristics of the 40-MeV electron plan were suitable for treatment. In conclusion, Monte Carlo simulations performed in this work indicate that two lateral opposing 40-MeV electron beams can be used for pediatric whole brain irradiation at FLASH dose rates of >115 Gy/s and serve as motivation for a practical clinical FLASH radiotherapy system, which can be implemented in the near future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evolution of charge density wave soft phonon modes in Pd 𝑥 ⁢ErTe 3

Here, we investigated the lattice dynamics of quasi-two-dimensional Pd-intercalated ErTe 3 in relation to its charge-density-wave (CDW) transitions by means of x-ray diffuse and meV-resolution inelastic x-ray scattering. In pristine ErTe 3 , CDW order develops at orthogonal in-plane wave vectors q$^𝑐_1$ =(0,0,0.29) (the 𝑐−CDW ) and q$^𝑎_2 $= (0.31,0,0) (the 𝑎−CDW ), with transition temperatures $𝑇^𝑐_1$ = 270K and $𝑇^𝑎_2$ = 160K, respectively. Remarkably, we observe diffuse x-ray scattering already near the higher transition temperature $𝑇^𝑐_1$ along 𝑎−CDW but at a slightly different wave vector q$^𝑎_1$ = (0.29,0,0). Inelastic x-ray scattering for Pd 0.01 ⁢ErTe 3 shows that a partial phonon softening at q$^𝑎_1$, underscoring the strong competition between ordering tendencies along the nearly equivalent in-plane axes of the orthorhombic lattice. For intercalation levels 𝑥 ≥ 0.02, the 𝑎−CDW state is suppressed. Nevertheless, a similar correlation between phonon softening and diffuse scattering persists along the [100] direction, again observed at q$^𝑎_1$ = (0.29,0,0) and $𝑇^𝑐_1$. These findings suggest that the 𝑎−CDW is fully suppressed for 𝑥 ≥ 0.02, and that the residual diffuse scattering at originates from the partial phonon softening associated with the 𝑐−CDW, reflected by the near equality of the absolute size of q$^𝑐_1$ and q$^𝑎_1$.

Maity, Avishek [Technische Univ. München, Garching↗

Burn parameters affect PAH emissions at conditions relevant for prescribed fires

Wildfire smoke is a health hazard as it contains carcinogenic volatile compounds and fine particulate matter. In particular, exposure to polycyclic aromatic hydrocarbons (PAHs) is a major concern, since these compounds have been recognized as important contributors to the overall carcinogenic risk. In this work, gas and particle-phase PAH emissions from combustion of Eastern White Pine (Pinus strobus) were quantified using time-of-flight mass spectrometry over a range of burn conditions representative of wildfires and prescribed fires, including fuel moisture, heat flux, and oxygen concentration. We found that changing the burn environment lead to a variability of up to 77% in phenanthrene/anthracene emissions. This could explain a large part of the variability in PAH emission factors from biomass combustion reported in the literature. Here, we found that optimal conditions for fuel moisture content of 20–30%, sample heat load of 60 - 70 kW m -2 , and oxygen concentrations of 5–15% can significantly reduce the emissions of heavy molar weight PAHs. Our analysis showed that the relative carcinogenic risk from PAH exposure can be reduced by more than 50% under optimal conditions. In light of the increasing use of prescribed fire for forest management, the relationship between emissions and burn conditions that we have established provides a guidance for assessing the expected health impact from prescription burns, and can inform strategies to reduce PAH emissions from prescribed fire activities.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Thermal processing to modulate surface chemistry and bulk charge distribution in nickel-rich layered lithium positive electrodes

The broader application of nickel-rich layered oxides as positive electrode materials for lithium-ion batteries has been hindered by their high manufacturing cost and inferior cycling stability. Thermal processing, which is integral to electrode materials manufacturing and fundamental in materials science, has not been fully utilized to design advanced positive electrode materials. Herein, we demonstrate the capability of using quenching heat treatment to regulate Li distribution and modulate electronic structure near particle surface. The resulting materials exhibit less parasitic reactions with the electrolyte and an improved charge distribution homogeneity in secondary particles, leading to more stable cycling performance at high voltages (4.5 V vs Li/Li + ). Our synchrotron X-ray analyses reveal the underlying interplay between surface structure and bulk charge distribution in positive electrode materials particles. While strategies used to stabilize positive electrode materials through compositional control, surface modification, and electrolyte engineering have become mature, thermal processing can be advantageous to further improve positive electrode materials manufacturing.

36 MATERIALS SCIENCE↗

Imaging and dosimetric characteristics of 67 Cu

In recent years the use of beta-emitting radiopharmaceuticals for cancer therapy has expanded rapidly following development of therapeutics for neuroendocrine tumors, prostate cancer, and other oncologic malignancies. One emerging beta-emitting radioisotope of interest for therapy is 67 Cu (t 1/2 : 2.6 d) due to its chemical equivalency with the widely-established positron-emitting isotope 64 Cu (t 1/2 : 12.7 h). Here we evaluate both the imaging and dosimetric characteristics of 67 Cu, as well as producing the first report of SPECT/CT imaging using 67 Cu. To this end, 67 Cu was produced by photon-induced reactions on isotopically-enriched 68 Zn at the Low-Energy Accelerator Facility (LEAF) of Argonne National Laboratory, followed by bulk separation of metallic 68 Zn by sublimation and radiochemical purification by column chromatography. Gamma spectrometry was performed by efficiency-calibrated high-purity germanium (HPGe) analysis to verify absolute activity calibration and establish radionuclidic purity. Absolute activity measurements corroborated manufacturer-recommended dose-calibrator settings and no radionuclidic impurities were observed. Using the Clinical Trials Network anthropomorphic chest phantom, SPECT/CT images were acquired. Medium Energy (ME) SPECT collimation was found to provide the best image quality from the primary 185 keV gamma emission of 67 Cu. Reconstructed images of 67 Cu were similar in quality to images acquired using 177 Lu. Recovery coefficients were calculated and compared against quantitative images of 99m Tc, 177 Lu, and 64 Cu within the same anthropomorphic chest phantom. Production and clinical imaging of 67 Cu appears feasible, and future studies investigating the therapeutic efficacy of 67 Cu-based radiopharmaceuticals are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quench Behavior of 18-mm-Period, 1.1-m-Long Nb 3 Sn Undulator Magnets

A novel Nb 3 Sn-based superconducting undulator (SCU) was developed and integrated into the Advanced Photon Source (APS) at Argonne National Laboratory. The SCU achieved user operation within an accelerator environment. Compared to its Nb-Ti counterpart, the Nb 3 Sn SCU operates at substantially higher currents. Thus, a detailed experimental evaluation of the SCU magnets’ performance was necessary under both “wet” and indirectly cooled conditions to ensure its reliability during operation. Here our study indicated that the cooling method has a noticeable influence on the magnet's behavior. Specifically, energy dissipation in the magnets during quenches was observed to be greater under indirect cooling than with “wet” cooling. This investigation provided insights into the safe operational limits. Guided by these insights the more challenging high-current tests were successfully carried out at the end of the user phase. The SCU achieved the design undulator field of 1.17 T at 820 A and 4.2 K, with a magnetic gap of 9.5 mm and a period of 18 mm. Actual performance exceeded the specifications, reaching 850 A.

43 PARTICLE ACCELERATORS↗

NDX: Neutron Dose Rate Meters with Extended Capabilities

Particle accelerators, irradiation facilities, and nuclear power plants would benefit from using neutron dose rate meters featuring improved energy response covering full range of expected neutron energies, improved dynamic range of measured dose rates while providing the real-time data, and improved ability to operate in harsh radiation environments including heavy photon backgrounds and pulsed beams. The novel design of the neutron moderator for the NDX dose rate meter implements a layer of a Beryllium-loaded medium Z material which, similar to the earlier known WENDI detectors, allows the device to detect higher energy neutron flux and convert it to dose. Using Beryllium helps to fill the known dip in the response functions around 5-50 MeV. Optimized design parameter set, obtained using FLUKA Monte Carlo simulations, features the NDX moderator made of polyethylene embedding a layer of BeCu alloy inside, with the dose rate response constant within ±10% in the neutron energy range from about 100 keV to 500 MeV, and ±25% essentially in the full energy range above thermal. A new sensor technique implemented in the NDX is based on using the Ionization Chamber (IC) filled with 3He gas to capture the moderated neutron fluence, and includes a symmetric IC filled with regular 4He to evaluate the contributions due to the non-neutron ionizing radiation. Advantages of the method include large accessible dynamic range, relative insensitivity of the IC probes to photon radiation fields, and the ability to subtract their contribution. Two prototype NDX detectors were built, calibrated, and operated in various conditions at the CEBAF 12 GeV electron accelerator at JLab. The first results showed reliable neutron dose rate measurements in the presence of overwhelming photon radiation fields, and at practical high dose rate levels of up to approximately 10 Sv/h. Detector design, operation, first results, and further development plans are presented.

Degtiarenko, Pavel V.↗

Development of a rapid-transit system for precision nuclear physics measurements

A Rapid Belt-driven Irradiated Target Transfer System, named RABITTS, was developed for use at the Triangle Universities Nuclear Laboratory. This system allows for cyclic activation with neutron or photon beams, and measurement of reaction products using γ-ray spectroscopy. Both a 1 meter and 10 meter transfer system have been developed with transit times as low as 0.4 and 1.0 seconds, respectively. The systems are deployed at the tandem accelerator laboratory for use with monoenergetic neutron beams, and at the High-Intensity γ-ray Source facility for activation using photon beams. A detailed characterization of the systems’ performance and sensitivity is presented. In order to produce the highest accuracy cross-section data, a model for calculating corrections to cyclic activation with variable beam flux is developed and presented. We have commissioned these systems by measuring 197m Au, where we report a measured half-life of 7.73 ± 0.05 s and a 197 Au(n, n') 197m Au isomer production cross of 628 ± 28 mb at neutron energy E n = 2.0 MeV. In addition, we measured 90m Zr, where we report a measured half-life of 799.7 ± 8.0 ms and a 90 Zr(n, n') 90m Zr isomer production cross of 180 ± 12 mb at E n = 4.6 MeV. Furthermore, these measured half-lives are in excellent agreement with the evaluated values and the cross-section measurements are performed at previously unmeasured incident neutron energies.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Wavelength-dependent photodissociation of iodomethylbutane

Ultrashort XUV pulses of the Free-Electron-LASer in Hamburg (FLASH) were used to investigate laser-induced fragmentation patterns of the prototypical chiral molecule 1-iodo-2-methyl-butane (C 5 H 11 I) in a pump-probe scheme. Ion velocity-map images and mass spectra of optical-laser-induced fragmentation were obtained for subsequent FEL exposure with photon energies of 63 eV and 75 eV. These energies specifically address the iodine 4d edge of neutral and singly charged iodine, respectively. The presented ion spectra for two optical pump-laser wavelengths, i.e., 800 nm and 267 nm, reveal substantially different cationic fragment yields in dependence on the wavelength and intensity. For the case of 800-nm-initiated fragmentation, the molecule dissociates notably slower than for the 267 nm pump. The results underscore the importance of considering optical-laser wavelength and intensity in the dissociation dynamics of this prototypical chiral molecule that is a promising candidate for future studies of its asymmetric nature.

74 ATOMIC AND MOLECULAR PHYSICS↗

In-device Battery Failure Analysis

Lithium-ion batteries are indispensable power sources for a wide range of modern electronic devices. However, battery lifespan remains a critical limitation, directly affecting the sustainability and user experience. Conventional battery failure analysis in controlled lab settings may not capture the complex interactions and environmental factors encountered in real-world, in-device operating conditions. Here, this study analyzes the failure of commercial wireless earbud batteries as a model system within their intended usage context. Through multiscale and multimodal characterizations, the degradations from the material level to the device level are correlated, elucidating a failure pattern that is closely tied to the specific device configuration and operating conditions. The findings indicate that the ultimate failure mode is determined by the interplay of battery materials, cell structural design, and the in-device microenvironment, such as temperature gradients and their fluctuations. This holistic, in-device perspective on environmental influences provides critical insights for battery integration design, enhancing the reliability of modern electronics.

36 MATERIALS SCIENCE↗

Fermi and Swift Observations of GRB 190114C: Tracing the Evolution of High-energy Emission from Prompt to Afterglow

We report on the observations of gamma-ray burst (GRB) 190114C by the Fermi Gamma-ray Space Telescope and the Neil Gehrels Swift Observatory . The prompt gamma-ray emission was detected by the Fermi GRB Monitor (GBM), the Fermi Large Area Telescope (LAT), and the Swift Burst Alert Telescope (BAT) and the long-lived afterglow emission was subsequently observed by the GBM, LAT, Swift X-ray Telescope (XRT), and Swift UV Optical Telescope. The early-time observations reveal multiple emission components that evolve independently, with a delayed power-law component that exhibits significant spectral attenuation above 40 MeV in the first few seconds of the burst. This power-law component transitions to a harder spectrum that is consistent with the afterglow emission observed by the XRT at later times. This afterglow component is clearly identifiable in the GBM and BAT light curves as a slowly fading emission component on which the rest of the prompt emission is superimposed. As a result, we are able to observe the transition from internal-shock- to external-shock-dominated emission. We find that the temporal and spectral evolution of the broadband afterglow emission can be well modeled as synchrotron emission from a forward shock propagating into a wind-like circumstellar environment. We estimate the initial bulk Lorentz factor using the observed high-energy spectral cutoff. Considering the onset of the afterglow component, we constrain the deceleration radius at which this forward shock begins to radiate in order to estimate the maximum synchrotron energy as a function of time. We find that even in the LAT energy range, there exist high-energy photons that are in tension with the theoretical maximum energy that can be achieved through synchrotron emission from a shock. These violations of the maximum synchrotron energy are further compounded by the detection of very high-energy (VHE) emission above 300 GeV by MAGIC concurrent with our observations. We conclude that the observations of VHE photons from GRB 190114C necessitates either an additional emission mechanism at very high energies that is hidden in the synchrotron component in the LAT energy range, an acceleration mechanism that imparts energy to the particles at a rate that is faster than the electron synchrotron energy-loss rate, or revisions of the fundamental assumptions used in estimating the maximum photon energy attainable through the synchrotron process.

79 ASTRONOMY AND ASTROPHYSICS↗

Applications of machine learning to a compact magnetic spectrometer for high repetition rate, laser-driven particle acceleration

Accurately and rapidly diagnosing laser–plasma interactions is often difficult due to the time-intensive nature of the analysis and will only become more so with the rise of high repetition rate lasers and the desire to implement feedback on a commensurate timescale. Diagnostic analysis employing machine learning techniques can help address this problem while maintaining a high degree of accuracy. We report on the application of machine learning to the analysis of a scintillator-based electron spectrometer for experiments on high intensity, laser–plasma interactions at the Colorado State University Advanced Lasers and Extreme Photonics facility. Our approach utilizes a neural network trained on synthetic data and tested on experiments to extract the accelerated electron temperature. By leveraging transfer learning, we demonstrate an improvement in the neural network accuracy, decreasing the network error by 50%.

Swanson, K. K. (ORCID:0000000286880568)↗

Beam-spin asymmetry Σ for Σ – hyperon photoproduction off the neutron

We report a new measurement of the beam-spin asymmetry $\boldsymbol{\Sigma}$ for the $\vec{\gamma} n \rightarrow K^+\Sigma^-$ reaction using quasi-free neutrons in a liquid-deuterium target. The new dataset includes data at previously unmeasured photon energy and angular ranges, thereby providing new constraints on partial wave analyses used to extract properties of the excited nucleon states. The experimental data were obtained using the CEBAF Large Acceptance Spectrometer (CLAS), housed in Hall B of the Thomas Jefferson National Accelerator Facility (JLab). The CLAS detector measured reaction products from a liquid-deuterium target produced by an energy-tagged, linearly polarised photon beam with energies in the range 1.1 to 2.3 GeV. Predictions from an isobar model indicate strong sensitivity to $N(1720)3/2^+$, $\Delta(1900)1/2^-$, and $N(1895)1/2^-$, with the latter being a state not considered in previous photoproduction analyses. When our data are incorporated in the fits of partial-wave analyses, one observes significant changes in $\gamma$-$n$ couplings of the resonances which have small branching ratios to the $\pi N$ channel.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗