NASA Ames' COSmIC Laboratory Astrophysics Facility: Recent Results and Progress

The COSmIC facility was developed at NASA Ames to study interstellar, circumstellar and planetary analogs in the laboratory]. COSmIC stands for "Cosmic Simulation Chamber" and is dedicated to the study of neutral and ionized molecules and nanoparticles under the low temperature and high vacuum conditions that are required to simulate space environments. COSmIC integrates a variety of instruments that allow generating; processing and monitoring simulated space conditions in the laboratory. It is composed of a Pulsed Discharge Nozzle (PDN) expansion that generates a plasma in a free supersonic jet expansion coupled to high-sensitivity, complementary in situ diagnostic tools, used for the detection and characterization of the species present in the expansion: a Cavity Ring Down Spectroscopy (CRDS) and fluorescence spectroscopy systems for photonic detection, and a Reflectron Time-Of-Flight Mass Spectrometer (ReTOF-MS) for mass detection. Recent advances achieved in laboratory astrophysics using COSmIC will be presented, in particular in the domain of the diffuse interstellar bands (DIBs) and the monitoring, in the laboratory, of the formation of dust grains and aerosols from their gasphase molecular precursors in environments as varied as circumstellar outflows and planetary atmospheres. Plans for future laboratory experiments on cosmic molecules and grains in the growing field of laboratory astrophysics (NIR-MIR CRDS, Laser Induced Fluorescence spectra of cosmic molecule analogs and the laser induced incandescence spectra of cosmic grain analogs) will also be addressed as well as the implications of the on-going studies for astronomy.

Laboratory Astrophysics↗

GaN/AlGaN Avalanche Photodiode Detectors for High Performance Ultraviolet Sensing Applications

The shorter wavelengths of the ultraviolet (UV) band enable detectors to operate with increased spatial resolution, variable pixel sizes, and large format arrays, benefitting a variety of NASA, defense, and commercial applications. AlxGa1-xN semiconductor alloys, which have attracted much interest for detection in the UV spectral region, have been shown to enable high optical gains, high sensitivities with the potential for single photon detection, and low dark current performance in ultraviolet avalanche photodiodes (UV-APDs). We are developing GaN/AlGaN UV-APDs with large pixel sizes that demonstrate consistent and uniform device performance and operation. These UV-APDs are fabricated through high quality metal organic chemical vapor deposition (MOCVD) growth on lattice-matched, low dislocation density GaN substrates with optimized material growth and doping parameters. The use of these low defect density substrates is a critical element to realizing highly sensitive UV-APDs and arrays with suppressed dark current under high electric fields.Optical gains greater than 5X10 (exp 6) with enhanced quantum efficiencies over the 350-400 nm spectral range have been demonstrated, enabled by a strong avalanche multiplication process. Furthermore, we are developing 6X6 arrays of devices to test high gain UV-APD array performance at ~355 nm. These variable-area GaN/AlGaN UV-APD detectors and arrays enable advanced sensing performance over UV bands of interest with high resolution detection for NASA Earth Science applications.

Sood, Ashok K.↗

Synthesis of CdZnTeSe single crystals for room temperature radiation detector fabrication: mitigation of hole trapping effects using a convolutional neural network

In this article, we report the growth of Cd 0.9 Zn 0.1 Te 0.97 Se 0.03 (CZTS) wide bandgap semiconductor single crystals for room temperature gamma-ray detection using a modified vertical Bridgman method. Charge transport properties measured in the radiation detectors, fabricated from the grown CZTS crystals, indicated signs of hole trapping. Hole traps inhibit high-resolution radiation detection especially for energetic gamma rays. Machine learning (ML) applications are gaining tremendous mpetus in improving device and sensor performance by compensating for limi tations arising from such intrinsic material properties. In this article, we describe a deep convolutional neural network (CNN) that has demonstrated remarkable efficiency in identifying the energy of a gamma photon detected by a CZTS detector. The CNN has been trained using simulated data that resemble output pulses from actual CZTS detectors when exposed to 662-keV gamma photons. The device properties required for the simulation have been derived from radiation detection measurements on a real Cd 0.9 Zn 0.1 Te 0.97 Se 0.03 detector fabricated in our laboratory. The CNN has been trained with detector pulses arising through photoelectric (PE) and Compton scattering (CS) separately. The percentage error in predicting the detected energies, within an extremely small duration of 0.28 ms, was found to be lower than 0.1% for gamma energies above 50 keV and for training datasets con taining PE and CS events separately. The CNN was also validated for a mixed PE and CS dataset to obtain a prediction error of 1%. Additionally, the effect of detector resolution on the efficiency of the CNN was also explored.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Possible X-Ray Detection of the Binary Millisecond Pulsar J1012+5307

A possible X-ray detection of the newly discovered binary millisecond radio pulsar PSR J1012+5307 was obtained from an archival ROSAT observation. The 80 +/- 24 photons detected correspond to a 0.1 - 2.4 keV luminosity of approx. = 2.5 x 10(exp 30) erg/s at the nominal dispersion-measure distance of 520 pc. This luminosity is a factor of 2 less than that of PSR J0437-4715, a near twin of PSR J1012+5307 in its spin parameters and energetics, and the only millisecond pulsar from which pulsed X-rays have definitely been detected. PSR J1012+5307 is also within 6 deg of the "HI hole" in Ursa Major, providing a new estimate of the electron column density through this region which confirms that the ionized column density is also low. The small neutral column density to PSR J1012+5307, N(sub H) less than 7.5 x 10(exp 19)/sq cm, will facilitate future soft X-ray study, which will help to discriminate between thermal and nonthermal origins of the X-ray emission in millisecond pulsars.

Halpern, Jules P.↗

Search for photons above 10 18 eV by simultaneously measuring the atmospheric depth and the muon content of air showers at the Pierre Auger Observatory

The Pierre Auger Observatory is the most sensitive instrument to detect photons with energies above 1 0 17 eV . It measures extensive air showers generated by ultrahigh energy cosmic rays using a hybrid technique that exploits the combination of a fluorescence detector with a ground array of particle detectors. The signatures of a photon-induced air shower are a larger atmospheric depth of the shower maximum ( X max ) and a steeper lateral distribution function, along with a lower number of muons with respect to the bulk of hadron-induced cascades. In this work, a new analysis technique in the energy interval between 1 and 30 EeV ( 1 EeV = 1 0 18 eV ) has been developed by combining the fluorescence detector-based measurement of X max with the specific features of the surface detector signal through a parameter related to the air shower muon content, derived from the universality of the air shower development. No evidence of a statistically significant signal due to photon primaries was found using data collected in about 12 years of operation. Thus, upper bounds to the integral photon flux have been set using a detailed calculation of the detector exposure, in combination with a data-driven background estimation. The derived 95% confidence level upper limits are 0.0403, 0.01113, 0.0035, 0.0023, and 0.0021 km − 2 sr − 1 yr − 1 above 1, 2, 3, 5, and 10 EeV, respectively, leading to the most stringent upper limits on the photon flux in the EeV range. Compared with past results, the upper limits were improved by about 40% for the lowest energy threshold and by a factor 3 above 3 EeV, where no candidates were found and the expected background is negligible. The presented limits can be used to probe the assumptions on chemical composition of ultrahigh energy cosmic rays and allow for the constraint of the mass and lifetime phase space of super-heavy dark matter particles. Published by the American Physical Society 2024

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of High-Temperature SiPM Noise

Introduction • Background: Silicon photomultipliers (SiPMs) are compact, low-power, and high-efficiency detectors that are increasingly used in radiation detection applications like medical imaging and nuclear safeguards. The have advantages of PMTs because they are smaller, operate at lower voltages, and offer high photon detection efficiency. • Challenges: SiPMs suffer from increased dark count rate (DCR) and optical crosstalk (OCT), which degrades performance. • Purpose of study: This study compares the Advansid ASD-NUV3S-P-40, Broadcom AFBR-S4K33C0147L, and Onsemi MicroFJ-30035-TSVTR under four different temperatures to compare their performance in harsh environments.

Fritchie, Jacob↗

Improved heavy-ion PID using scintillation light detector with neural network analysis: a Monte Carlo simulation study

The photon collection efficiency of gaseous scintillator detectors varies according to the position of the impinging charged particles in the medium that generates scintillation light. Thus, when impinging particles are distributed over a large area, the intrinsic photon-number resolution of the system is affected by a large variation. This work presents and discusses a method for adjusting the total number of detected photons to account for variation in the photon collection efficiency as a function of the position of the light source within the scintillating medium. The method was developed and validated by processing data from systematic simulation studies based on GEANT4 that model the response of the Energy Loss Optical Scintillation System (ELOSS) detector. The position of the charged particle is calculated using a deep neural network algorithm. This is accomplished by analyzing the distribution of scintillation light recorded by the array of photosensors. The estimated particle position is then used to calculate the correction factor and adjust the amount of captured light to account for variations in the photon collection efficiency. The neural network algorithm provides excellent tracking capabilities, achieving sub-millimeter position resolution and an angular resolution of 12 mrad, approaching the performance of traditional tracking detectors (e.g., drift chambers). The present method can be generalized to any optical scintillation system where the photon collection efficiency depends on the position of the impinging particle.

Heavy-ion detectors↗

Moiré photonics and optoelectronics

Moiré superlattices, the artificial quantum materials, have provided a wide range of possibilities for the exploration of completely new physics and device architectures. In this Review, we focus on the recent progress on emerging moiré photonics and optoelectronics, including but not limited to moiré excitons, trions, and polaritons; resonantly hybridized excitons; reconstructed collective excitations; strong mid- and far-infrared photoresponses; terahertz single-photon detection; and symmetry-breaking optoelectronics. We also discuss the future opportunities and research directions in this field, such as developing advanced techniques to probe the emergent photonics and optoelectronics in an individual moiré supercell; exploring new ferroelectric, magnetic, and multiferroic moiré systems; and using external degrees of freedom to engineer moiré properties for exciting physics and potential technological innovations.

Science & Technology - Other Topics↗

Semiconductor superlattice photodetectors

Superlattice photodetectors were investigated. A few major physical processes in the quantum-well heterostructures related to the photon detection and electron conduction mechanisms, the field effect on the wave functions and the energy levels of the electrons, and the optical absorption with and without the photon assistance were studied.

Chuang, S. L.↗

Multiple-Quantum-Well Intersubband Infrared Detector

Proposed multiple-quantum-well intersubband semiconductor device detects photons over broader range of wavelengths. Device is stack of substacks, each of which contains quantum-well layers sensitive to different narrow band of wavelengths. Bandwidth and detectivity increased.

Borenstain, Shmuel I.↗

Characterization of Digital Silicon Photomultipliers

Digital Silicon photomultipliers (Digital SiPMs) have become an increasingly viable option for single-photon detection due to their compact size and precise timing and resolution. The following work characterizes the noise performance of a diSiPM designed and tested in-house at Fermilab. The SiPM consists of a 26x32 array of single-photon avalanche diode (SPAD) cells. Through the implementation of a shift register masking circuit, individual SPAD cells can be enabled and disabled at will, allowing for precise detection measurements of single columns (accumulator channels) and cells. The provided circuit design operates on voltage clock pulses and collects data on clock edges allowing for precise tuning of the data collection process by varying the clock frequency, pulse width, and integration period.

Shoemaker, Oliver [U. Chicago (main)]↗

Light detection with power and signal transmission over fiber

The Deep Underground Neutrino Experiment is a next generation long baseline (1300 km) neutrino oscillation experiment. The neutrino beam measurements will be performed by a near detector and far detector. The far detector will consist of four modules, installed 1.5 km deep underground, based on Liquid Argon Time Projection Chamber (LArTPC) technology to detect particles. The Vertical Drift (VD) LArTPC is a recent technology proposed by the DUNE collaboration for the second FD module. In VD, light collection will be optimized by embedding photon detectors within the LArTPC cathode, which is biased at −300 kV. As a result, power must arrive to the Photon Detection System and signal must be transmitted via non-conductive material. The proposed solution is to use Power-over-Fiber and Signal-over-Fiber. An intense validation of the system is being performed by the collaboration at the CERN Neutrino Platform. The design of the system and the results of the validation collected over the first half of 2022 are presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-energy reconstructions, central electron temperature measurements, and early detection of the birth and growth of runaway electrons using a versatile soft x-ray pinhole camera at MST

A multi-energy soft x-ray pinhole camera has been designed, built, and deployed at the Madison Symmetric Torus to aid the study of particle and thermal transport, as well as MHD stability physics. This novel imaging diagnostic technique employs a pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently on each pixel. The detector of choice is a PILATUS3 100 K with a 450 μm thick silicon sensor and nearly 100 000 pixels sensitive to photon energies between 1.6 and 30 keV. An ensemble of cubic spline smoothing functions has been applied to the line-integrated data for each time-frame and energy-range, obtaining a reduced standard-deviation when compared to that dominated by photon-noise. The multi-energy local emissivity profiles are obtained from a 1D matrix-based Abel-inversion procedure. Central values of Te can be obtained by modeling the slope of the continuum radiation from ratios of the inverted radial emissivity profiles over multiple energy ranges with no a priori assumptions of plasma profiles, magnetic field reconstruction constraints, high-density limitations, or need of shot-to-shot reproducibility. In tokamak plasmas, a novel application has recently been tested for early detection, 1D imaging, and study of the birth, exponential growth, and saturation of runaway electrons at energies comparable to 100 × Te,0; thus, early results are also presented.

Delgado-Aparicio, L. F. (ORCID:0000000167394380)↗

SOFT PARTICLE DETECTORS

Gas-filled proportional counter for photon detection in the .1-20 kev range

PROPORTIONAL COUNTER↗

The development and test of multi-anode microchannel array detector systems. Part 2: Soft X-ray detectors

Detector systems based on the high gain microchannel plate (MCP) electron multiplier were used extensively for imaging at soft X-ray wavelengths both on the ground and in space. The latest pulse counting electronic readout systems provide zero readout noise, spatial resolutions (FWHM) of 25 microns or better and can determine the arrival times of detected photons to an accuracy of the order of 100 ns. These systems can be developed to produce detectors with active areas of 100 nm in diameter or greater. The use of CsI photocathodes produces very high detective quantum efficiencies at wavelengths between about 100 and 1A (approximately 0.1 to 10 keV) with moderate energy resolution. The operating characteristics of the different types of soft X-ray MCP detector systems are described and the prospects for future developments are discussed.

Timothy, J. G.↗

Microchannel plates and image detection at soft X-ray wavelengths

Detector systems based on the high-gain microchannel plate (MCP) electron multiplier have been used extensively for imaging at soft X-ray wavelengths both on the ground and in space. The latest pulse-counting electronic readout systems provide zero readout-noise, spatial resolutions (FWM) of 25 microns or better and can determine the arrival times of detected photons to an accuracy of the order of 100 ns. These systems can br developed to produce detectors with active areas of 100 mm in diameter or greater. The use of CsI photocathodes produces very high detective quantum efficiencies to wavelengths between about 100 and 1A (0.1 to 10 keV) with moderate energy resolution. The operating characteristics of the different types of soft X-ray MCP detector systems are described, and the prospects for future developments are discussed.

Timothy, J. G.↗

Possible Evidence for an Event Horizon in Cyg XR-1

The X-ray emitting component in the Cyg XR-1/HDE226868 system is a leading candidate for identification as a stellar-mass sized black hole. The positive identification of a black hole as predicted by general relativity requires the detection of an event horizon surrounding the point singularity. One signature of such an event horizon would be the existence of dying pulse trains emitted by material spiraling into the event horizon from the last stable orbit around the black hole. We observed the Cyg XR-1 system at three different epochs in a 1400 - 3000 A bandpass with 0.1 ms time resolution using the Hubble Space Telescope's High Speed Photometer. Repeated excursions of the detected flux by more than three standard deviations above the mean are present in the UV flux with FWHM 1 - 10 ms. If any of these excursions are pulses of radiation produced in the system (and not just stochastic variability associated with the Poisson distribution of detected photon arrival times), then this short a timescale requires that the pulses originate in the accretion disk around Cyg XR-1. Two series of pulses with characteristics similar to those expected from dying pulse trains were detected in three hours of observation.

Dolan, Joseph F.↗

Detection of scintillation light in noble gases with wavelength-shifting optical fibers

Wavelength-shifting (WLS) techniques enable particle detectors based on noble gases, whose scintillation light is predominantly emitted in the vacuum-ultraviolet. We investigate WLS fibers coated with tetraphenyl butadiene (TPB) for scintillation light detection in gaseous xenon and argon at pressures up to 8.5 bar, motivated by future high-pressure xenon time-projection chambers of the NEXT program. Two detector configurations are studied: an elongated high-pressure vessel with four PTFE panels equipped with WLS fibers read by temperature-stabilized SiPMs, and a compact box-shaped detector operated at 1 bar Xe with WLS fibers read out by PMTs. Both operate with continuous gas purification. The detector response is characterized using cosmic muons and alpha particles from a $^{241}$Am source. With the SiPM setup, we measure a light collection efficiency (LCE) of ${1.18 \pm 0.01~\mathrm{(sta.)}~^{+0.07}_{-0.09}~\mathrm{(sys.)}~\%}$ for xenon and ${1.07 \pm 0.01~\mathrm{(sta.)}~^{+0.06}_{-0.08}~\mathrm{(sys.)}~\%}$ for argon. With PMT readout, we measure a LCE of ${0.45 \pm 0.01~\mathrm{(sta.)} \pm 0.05~\mathrm{(sys.)}~\%}$ in xenon, in agreement with the SiPM result once photon detection efficiency is accounted for. Average scintillation waveforms in xenon and argon are studied to assess the time structure of the emitted light. Cosmic-muon measurements yield a mean energy required to produce a scintillation photon $45\pm7~\mathrm{(sta.)}~^{+4}_{-5}~\mathrm{(sys.)}~\mathrm{eV}$ at 1.5 bar, in agreement with the literature. The results demonstrate that TPB-coated WLS fiber systems can reliably detect scintillation light in high-pressure gaseous noble detectors, with a LCE representing an upper limit for realistic large-scale TPCs, where additional photon losses from materials and fiber attenuation are expected.

Soleti, S. R. [Donostia Intl. Phys. Ctr., San Seba↗