Search NASA⌕ Search

SEARCH · Search NASA

Results for “Photonic systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Development and test of photon-counting microchannel plate detector arrays for use on space telescopes

The full sensitivity, dynamic range, and photometric stability of microchannel array plates(MCP) are incorporated into a photon-counting detection system for space operations. Components of the system include feedback-free MCP's for high gain and saturated output pulse-height distribution with a stable response; multi-anode readout arrays mounted in proximity focus with the output face of the MCP; and multi-layer ceramic headers to provide electrical interface between the anode array in a sealed detector tube and the associated electronics.

Timothy, J. G.↗

Long wavelength photoconductive detectors for airborne and orbital infrared astronomy

Seven gallium doped germanium (Ge:Ga) photoconductive infrared detectors were fabricated and mounted in integrating cavities. In addition, a cold preamplifier package consisting of J230 junction field effect transistors (JFETs) was produced. Tests of the system under low photon background conditions indicated that sensitivity was limited by the Johnson noise of the load resistor. The detectors were mounted in the Ames cooled grating spectrometer, and flown on the Kuiper Airborne Observatory. Good quality astronomical data were obtained during the flight of 7 July 1983.

Houck, J. R.↗

An overview of the first results on the solar array materials passive LDEF experiment (sample), A0171

Power degradation in the solar cells was consistent with the exposure environment and appears to be produced principally by the radiation and atomic oxygen environments. Atomic oxygen erosion was generally as expected; atomic oxygen effects dominated for the most part in materials that were both atomic oxygen and ultraviolet vulnerable. Silicone coatings appear to protect Kapton, and adhesive systems contained under photon opaque materials were surprisingly environmentally resistant. A high density of small micro-meteroid/space debris impacts were observed on mirrors, protective coatings, paints, and composites. New synergistic effects of the space environment were noted in the interaction of atomic oxygen and copious amounts of contamination and in the induced luminescence of many materials.

Ann F Whitaker↗

Fabricating binary optics: An overview of binary optics process technology

A review of binary optics processing technology is presented. Pattern replication techniques have been optimized to generate high-quality efficient microoptics in visible and infrared materials. High resolution optical photolithography and precision alignment is used to fabricate maximally efficient fused silica diffractive microlenses at lambda = 633 nm. The degradation in optical efficiency of four-phase-level fused silica microlenses resulting from an intentional 0.35 micron translational error has been systematically measured as a function of lens speed (F/2 - F/60). Novel processes necessary for high sag refractive IR microoptics arrays, including deep anisotropic Si-etching, planarization of deep topography and multilayer resist techniques, are described. Initial results are presented for monolithic integration of photonic and microoptic systems.

Stern, Margaret B.↗

Apparatus and method using a holographic optical element for converting a spectral distribution to image points

A holographic optical element transforms a spectral distribution of light to image points. The element comprises areas, each of which acts as a separate lens to image the light incident in its area to an image point. Each area contains the recorded hologram of a point source object. The image points can be made to lie in a line in the same focal plane so as to align with a linear array detector. A version of the element has been developed that has concentric equal areas to match the circular fringe pattern of a Fabry-Perot interferometer. The element has high transmission efficiency, and when coupled with high quantum efficiency solid state detectors, provides an efficient photon-collecting detection system. The element may be used as part of the detection system in a direct detection Doppler lidar system or multiple field of view lidar system.

McGill, Matthew J.↗

Space Qualification Issues in Acousto-optic and Electro-optic Devices

Satellite and space-based applications of photonic devices and systems require operational reliability in the harsh environment of space for extended periods of time. This in turn requires every component of the systems and their packaging to meet space qualifications. Acousto- and electro-optical devices form the major components of many current space based optical systems, which is the focus of this paper. The major space qualification issues are related to: mechanical stability, thermal effects and operation of the devices in the naturally occurring space radiation environment. This paper will discuss acousto- and electro-optic materials and devices with respect to their stability against mechanical vibrations, thermal cycling in operating and non-operating conditions and device responses to space ionizing and displacement radiation effects. Selection of suitable materials and packaging to meet space qualification criteria will also be discussed. Finally, a general roadmap for production and testing of acousto- and electro-optic devices will be discussed.

Prasad, Narasimha S.↗

A Catalog of Terrestrial Gamma-Ray Flashes Observed with the Fermi- Gamma-Ray Burst Monitor: The First Sixteen Months of Operation

The Gamma-ray Burst Monitor (GBM) on the Fermi Gamma-ray Space Telescope Observatory (Fermi) has been detecting on the average about one terrestrial gamma-ray flash every four weeks. This catalog presents the basic characteristics of observed TGFs from the beginning of the Fermi-GBM operation in 2008 July until 2009 October. The thick bismuth germanate (BGO) scintillation detectors of the GBM system have observed photon energies from TGFs at energies above 30 MeV. It is found that the TGF pulses are typically shorter than previously reported, and in several cases less than 0.2ms. Extremely high counting rates are encountered ~200kcps or higher per detector during portions of some TGFs. These high rates require considerable corrections (with inherent assumptions) to the observed data in order to derive the true counting rates.

Fishman, Gerald J.↗

Airborne Lidar Measurements of Atmospheric Pressure Made Using the Oxygen A-Band

Accurate measurements of greenhouse gas mixing ratios on a global scale are currently needed to gain a better understanding of climate change and its possible impact on our planet. In order to remotely measure greenhouse gas concentrations in the atmosphere with regard to dry air, the air number density in the atmosphere is also needed in deriving the greenhouse gas concentrations. Since oxygen is stable and uniformly mixed in the atmosphere at 20.95%, the measurement of an oxygen absorption in the atmosphere can be used to infer the dry air density and used to calculate the dry air mixing ratio of a greenhouse gas, such as carbon dioxide or methane. OUT technique of measuring Oxygen uses integrated path differential absorption (IPDA) with an Erbium Doped Fiber Amplifier (EDF A) laser system and single photon counting module (SPCM). It measures the absorbance of several on- and off-line wavelengths tuned to an O2 absorption line in the A-band at 764.7 nm. The choice of wavelengths allows us to maximize the pressure sensitivity using the trough between two absorptions in the Oxygen A-band. Our retrieval algorithm uses ancillary meteorological and aircraft altitude information to fit the experimentally obtained lidar O2 line shapes to a model atmosphere and derives the pressure from the profiles of the two lines. We have demonstrated O2 measurements from the ground and from an airborne platform. In this paper we will report on our airborne measurements during our 2011 campaign for the ASCENDS program.

Riris, Haris↗

Real-Time Optical Receiver Decoder Architecture Changes for High-Speed Modes

The National Aeronautics and Space Administration (NASA) at Glenn Research Center (GRC) has developed an optical communications transmitter and receiver using Commercial-off-the-shelf (COTS) components. The goal of this project is to become fully compliant with Consultative Committee for Space Data Systems (CCSDS) High Photon Efficiency (HPE) Optical Communications Coding and Synchronization standard. The receive modem’s decoder has been modified using shift registers to enable the decoding of higher data rate pulse-position modulation (PPM) 4 and PPM-8 signals. PPM-4 and PPM-8 is then verified by comparing the codeword error rate (CWER) of a hardware implementation to a software simulation. The changes show the capability to decode PPM-4 and PPM-8 for a single decoder. This memorandum details the changes made, the performance achieved with the changes, and necessary future work.

PPM↗

Overview of the Chandra X-Ray Observatory Facility

The Chandra X-Ray Observatory (originally called the Advanced X-Ray Astrophysics Facility - AXAF) is the X-Ray component of NASA's "Great Observatory" Program. Chandra is a NASA facility that provides scientific data to the international astronomical community in response to scientific proposals for its use. The Observatory is the product of the efforts of many organizations in the United States and Europe. The Great Observatories also include the Hubble Space Telescope for space-based observations of astronomical objects primarily in the visible portion of the electromagnetic spectrum, the now defunct Compton Gamma- Ray Observatory that was designed to observe gamma-ray emission from astronomical objects, and the soon-to-be-launched Space Infrared Telescope Facility (SIRTF). The Chandra X-Ray Observatory (hereafter CXO) is sensitive to X-rays in the energy range from below 0.1 to above 10.0 keV corresponding to wavelengths from 12 to 0.12 nanometers. The relationship among the various parts of the electromagnetic spectrum, sorted by characteristic temperature and the corresponding wavelength, is illustrated. The German physicist Wilhelm Roentgen discovered what he thought was a new form of radiation in 1895. He called it X-radiation to summarize its properties. The radiation had the ability to pass through many materials that easily absorb visible light and to free electrons from atoms. We now know that X-rays are nothing more than light (electromagnetic radiation) but at high energies. Light has been given many names: radio waves, microwaves, infrared, visible, ultraviolet, X-ray and gamma radiation are all different forms. Radio waves are composed of low energy particles of light (photons). Optical photons - the only photons perceived by the human eye - are a million times more energetic than the typical radio photon, whereas the energies of X-ray photons range from hundreds to thousands of times higher than that of optical photons. Very low temperature systems (hundreds of degrees below zero Celsius) produce low energy radio and microwave photons, whereas cool bodies like our own (about 30 degrees Celsius) produce infrared radiation. Very high temperatures (millions of degrees Celsius) are one way of producing X-rays.

Weisskopf, M. C.↗

Maximum Likelihood Time-of-Arrival Estimation of Optical Pulses via Photon-Counting Photodetectors

Many optical imaging, ranging, and communications systems rely on the estimation of the arrival time of an optical pulse. Recently, such systems have been increasingly employing photon-counting photodetector technology, which changes the statistics of the observed photocurrent. This requires time-of-arrival estimators to be developed and their performances characterized. The statistics of the output of an ideal photodetector, which are well modeled as a Poisson point process, were considered. An analytical model was developed for the mean-square error of the maximum likelihood (ML) estimator, demonstrating two phenomena that cause deviations from the minimum achievable error at low signal power. An approximation was derived to the threshold at which the ML estimator essentially fails to provide better than a random guess of the pulse arrival time. Comparing the analytic model performance predictions to those obtained via simulations, it was verified that the model accurately predicts the ML performance over all regimes considered. There is little prior art that attempts to understand the fundamental limitations to time-of-arrival estimation from Poisson statistics. This work establishes both a simple mathematical description of the error behavior, and the associated physical processes that yield this behavior. Previous work on mean-square error characterization for ML estimators has predominantly focused on additive Gaussian noise. This work demonstrates that the discrete nature of the Poisson noise process leads to a distinctly different error behavior.

Erkmen, Baris I.↗

A photon-counting multichannel spectrometer

A multichannel detector system is described in which the positions of individual photon events in a high-gain image intensifier are decoded in the output of a video detector. The high-gain intensifier consists of a pair of three-stage electrostatic image-tube assemblies each containing three fiber-optically-coupled tubes potted in a rugged package with an internal high-voltage supply. Operation of the electrooptical system is discussed along with the pulse-detection process and the operation of the spectrograph in which the image-tube assembly is mounted. It is noted that the spectrometer detects 1.0 count/sec per A for an object of magnitude 13.0 at the peak of its response in the visual band when no light is lost on the slit, that a 10% coincidence correction is reached at an overall count rate of 860 per sec, and that the response follows an exponential law up to count rates of about 4000 per sec. The measured spectrum of the Seyfert galaxy NGC 5548 is provided as an example of the raw data produced by the instrument on a 1.5 meter telescope.

Shectman, S. A.↗

UV radiation field inside dense clouds - Its possible existence and chemical implications

Interstellar UV radiation cannot penetrate into the interior of dense clouds, and cosmic ray ionization is thought to be the sole driver of the gas phase chemistry. However, cosmic ray energy deposition also involves electronic excitation of the absorbing gas. It appears, therefore, possible that emissions resulting from these excitations might maintain a significant flux of chemically effective UV photons in the interior of dense clouds. The present investigation is concerned with this possibility, taking into account a simplified approach. This approach involves a consideration of Lyman and Werner band photons of molecular hydrogen and their relevance to C and CO chemistry. The results of this investigation suggest that a chemically significant flux of UV photons may exist inside dense clouds due to cosmic ray excitation of the various band systems of hydrogen. These photons would recover C I from the CO reservoir in dense clouds via photodissociation at an order of magnitude faster rate than that possible in connection with the reaction of CO with He(+).

Prasad, S. S.↗

Photonic Integrated Circuit (PIC) Device Structures: Background, Fabrication Ecosystem, Relevance to Space Systems Applications, and Discussion of Related Radiation Effects

Electronic integrated circuits are considered one of the most significant technological advances of the 20th century, with demonstrated impact in their ability to incorporate successively higher numbers transistors and construct electronic devices onto a single CMOS chip. Photonic integrated circuits (PICs) exist as the optical analog to integrated circuits; however, in place of transistors, PICs consist of numerous scaled optical components, including such "building-block" structures as waveguides, MMIs, lasers, and optical ring resonators. The ability to construct electronic and photonic components on a single microsystems platform offers transformative potential for the development of technologies in fields including communications, biomedical device development, autonomous navigation, and chemical and atmospheric sensing. Developing on-chip systems that provide new avenues for integration and replacement of bulk optical and electro-optic components also reduces size, weight, power and cost (SWaP-C) limitations, which are important in the selection of instrumentation for specific flight projects. The number of applications currently emerging for complex photonics systems-particularly in data communications-warrants additional investigations when considering reliability for space systems development. This Body of Knowledge document seeks to provide an overview of existing integrated photonics architectures; the current state of design, development, and fabrication ecosystems in the United States and Europe; and potential space applications, with emphasis given to associated radiation effects and reliability.

Body of Knowledge (BOK)↗

Two-Photon Fluorescence Correlation Spectroscopy

We will describe a two-photon microscope currently under development at the NASA Glenn Research Center. It is composed of a Coherent Mira 900 tunable, pulsed Titanium:Sapphire laser system, an Olympus Fluoview 300 confocal scanning head, and a Leica DM IRE inverted microscope. It will be used in conjunction with a technique known as fluorescence correlation spectroscopy (FCS) to study intracellular protein dynamics. We will briefly explain the advantages of the two-photon system over a conventional confocal microscope, and provide some preliminary experimental results.

Zimmerli, Gregory A.↗

Thermal background noise limitations

Modern detection systems are increasingly limited in sensitivity by the background thermal photons which enter the receiving system. Expressions for the fluctuations of detected thermal radiation are derived. Incoherent and heterodyne detection processes are considered. References to the subject of photon detection statistics are given.

Gulkis, S.↗