Cloud Droplet Measurement System for the ARM Tethered Balloon System (TBS) Field Campaign Report

The Mesa Photonics' cloud droplet measurement system (CDMS) performs in situ measurement of droplet size distribution and droplet number density in clouds. These characteristics are important cloud microphysical properties that are critical input parameters for atmospheric models and are also useful for proper calibration and validation of performance of other atmospheric measurement instrumentation. This small campaign was the first project (out of two) that involved integration of the CDMS into the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s tethered balloon system (TBS) and its initial testing at the ARM Southern Great Plains (SGP) atmospheric observatory. The follow-up campaign (AFC07016) involved testing of the CDMS under relevant conditions at the third ARM Mobile Facility (AMF3) at Oliktok Point, Alaska and making in situ measurements in clouds. The goal of this small field campaign was to deploy the CDMS on the ARM TBS, demonstrate its integrity and compatibility with the TBS, and test the wireless telecommunication system in preparation for subsequent in-cloud measurements at ARM’s North Slope of Alaska (NSA) observatory at Utqiagvik (formerly Barrow). The specific technical objectives included: (1) Integration of the Mesa Photonics' CDMS into the ARM TBS, (2) testing of the wireless telecommunication system of the CDMS, (3) evaluating the data acquisition software and image processing algorithms especially under high-background-illumination conditions, and (4) testing the ruggedness of the instrument's optical alignment and other performance characteristics. All objectives have been successfully met. The mounting hardware was designed and built mostly at Sandia National Laboratories (SNL), which allowed reliable mounting of the CDMS on the TBS and co-locating the CDMS with other instruments. The field tests were performed by the principal investigator (PI) in collaboration with the TBS operational crew led by D. Dexheimer. The field testing demonstrated good compatibility of the CDMS with the TBS. During the TBS flights, the crew did not experience any operational issues with the CDMS. The instrument demonstrated reliable operational characteristics, including sufficient battery life and good thermal management. The wireless telecommunication system has been successfully tested at TBS flight altitudes of up to 1000 m. During all flights, the CDMS raw data were wirelessly transmitted to the ground station and processed in real time. The ruggedness of the instrument's optical alignment was evaluated by performing calibration of the CDMS (using Mesa Photonics' fixed-size monodisperse droplet generator) before and after the campaign. The calibration was stable within the instrument's measurement precision. In summary, the campaign demonstrated good compatibility of the Mesa Photonics' CDMS with the ARM TBS. The flight tests confirmed the mechanical integrity of the CDMS and stability of its optical layout, as well as reliability of the wireless telecommunication system. Successful completion of this campaign provided a solid basis for the next campaign (AFC07016, November 2020), that involved testing of the CDMS during in-cloud TBS flights at AMF3 at Oliktok Point.

54 ENVIRONMENTAL SCIENCES↗

Three-dimensional co-axial linear photonic switch

Techniques, systems, and devices are disclosed that relate to coaxial photoconductive switch modules. The coaxial photoconductive switch may include an outer conductor, an inner conductor, and a photoconductive material positioned between the inner conductor and the outer conductor. The inner conductor, the outer conductor, and the photoconductive material have a predetermined height. A bias voltage may be applied between the inner conductor and the outer conductor. When light of a predetermined wavelength and a predetermined intensity is incident on the photoconductive material, the photoconductive material may break down allowing a current to flow through the photoconductive material between the inner conductor and the outer conductor.

Conway, Adam↗

Electro-refractive modulation in photonic structures

Methods, systems, and devices are described for electro-optic tuning. An example device may comprise a first layer comprising a transition metal di-chalcogenide material, a second layer comprising a conductive material, and a third layer comprising a dielectric material. The third layer may be disposed at least partially between the first layer and the second layer. An electrical potential difference applied between the first layer and the second layer may cause a tunable refractive index change in the first layer.

Lipson, Michal↗

Classifying topology in photonic crystal slabs with radiative environments

Abstract In the recent years, photonic Chern materials have attracted substantial interest as they feature topological edge states that are robust against disorder, promising to realize defect-agnostic integrated photonic crystal slab devices. However, the out-of-plane radiative losses in those photonic Chern slabs has been previously neglected, yielding limited accuracy for predictions of these systems’ topological protection. Here, we develop a general framework for measuring the topological protection in photonic systems, such as in photonic crystal slabs, while accounting for in-plane and out-of-plane radiative losses. Our approach relies on the spectral localizer that combines the position and Hamiltonian matrices of the system to draw a real-picture of the system’s topology. This operator-based approach to topology allows us to use an effective Hamiltonian directly derived from the full-wave Maxwell equations after discretization via finite-elements method (FEM), resulting in the full account of all the system’s physical processes. As the spectral FEM-localizer is constructed solely from FEM discretization of the system’s master equation, the proposed framework is applicable to any physical system and is compatible with commonly used FEM software. Moving forward, we anticipate the generality of the method to aid in the topological classification of a broad range of complex physical systems.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Nanoelectromechanical Control of Spin–Photon Interfaces in a Hybrid Quantum System on Chip

Color centers (CCs) in nanostructured diamond are promising for optically linked quantum technologies. Scaling to useful applications motivates architectures meeting the following criteria: C1 individual optical addressing of spin qubits; C2 frequency tuning of spin-dependent optical transitions; C3 coherent spin control; C4 active photon routing; C5 scalable manufacturability; and C6 low on-chip power dissipation for cryogenic operations. Here, we introduce an architecture that simultaneously achieves C1–C6. We realize piezoelectric strain control of diamond waveguide-coupled tin vacancy centers with ultralow power dissipation necessary. The DC response of our device allows emitter transition tuning by over 20 GHz, combined with low-power AC control. We show acoustic spin resonance of integrated tin vacancy spins and estimate single-phonon coupling rates over 1 kHz in the resolved sideband regime. Combined with high-speed optical routing, our work opens a path to scalable single-qubit control with optically mediated entangling gates.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

An operator-based approach to topological photonics

Abstract Recently, the study of topological structures in photonics has garnered significant interest, as these systems can realize robust, nonreciprocal chiral edge states and cavity-like confined states that have applications in both linear and nonlinear devices. However, current band theoretic approaches to understanding topology in photonic systems yield fundamental limitations on the classes of structures that can be studied. Here, we develop a theoretical framework for assessing a photonic structure’s topology directly from its effective Hamiltonian and position operators, as expressed in real space, and without the need to calculate the system’s Bloch eigenstates or band structure. Using this framework, we show that nontrivial topology, and associated boundary-localized chiral resonances, can manifest in photonic crystals with broken time-reversal symmetry that lack a complete band gap, a result that may have implications for new topological laser designs. Finally, we use our operator-based framework to develop a novel class of invariants for topology stemming from a system’s crystalline symmetries, which allows for the prediction of robust localized states for creating waveguides and cavities.

97 MATHEMATICS AND COMPUTING↗

Efficient light harvesting and photon sensing via engineered cooperative effects

Abstract Efficient devices for light harvesting and photon sensing are fundamental building blocks of basic energy science and many essential technologies. Recent efforts have turned to biomimicry to design the next generation of light-capturing devices, partially fueled by an appreciation of the fantastic efficiency of the initial stages of natural photosynthetic systems at capturing photons. In such systems extended excitonic states are thought to play a fundamental functional role, inducing cooperative coherent effects, such as superabsorption of light and supertransfer of photoexcitations. Inspired by this observation, we design an artificial light-harvesting and photodetection device that maximally harnesses cooperative effects to enhance efficiency. The design relies on separating absorption and transfer processes (energetically and spatially) in order to overcome the fundamental obstacle to exploiting cooperative effects to enhance light capture: the enhanced emission processes that accompany superabsorption. This engineered separation of processes greatly improves the efficiency and the scalability of the system.

42 ENGINEERING↗

SPC-70646 Specification for Reactor Supplemental Shielding for Use in DOME

NRIC is developing the Demonstration of Microreactor Experiments (DOME) test bed at the Idaho National Laboratory (INL) Materials and Fuels Complex (MFC): to allow for testing of advanced reactors in support of future licensing and commercial operations. One such need is a neutron and photon radiation shielding system to protect personnel and equipment from harsh neutron and photon fluxes during reactor operations and post shut down operations, disassembly, and decommissioning.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

System and method for curved light sheet projection during two-photon polymerization

A laser-based manufacturing system is disclosed for fabricating non-planar three-dimensional layers. The system may have a laser for producing a laser beam with a plurality of optical wavelengths. An optically dispersive element may be used for receiving the laser beam and splitting the beam into a plurality of distinct beam components, wherein each beam component has spatially separated optical spectral components. A phase mask may be used which is configured to receive at least one of the beam components emerging from the dispersive element and to create a modified beam. One or more focusing elements may then be used to receive the modified beam emerging from the phase mask and to focus the modified beam into a non-planar light sheet for use in fabricating a part.

Saha, Sourabh Kumar↗

A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mitigation of birefringence in cavity-based quantum networks using frequency-encoded photons

Atom-cavity systems offer unique advantages for building large-scale distributed quantum computers by providing strong atom-photon coupling while allowing for high-fidelity local operations of atomic qubits. However, in prevalent schemes where the photonic state is encoded in polarization, cavity birefringence introduces an energy splitting of the cavity eigenmodes and alters the polarization states, thus limiting the fidelity of remote entanglement generation. To address this challenge, we propose a scheme that encodes the photonic qubit in the frequency degree-of-freedom. The scheme relies on resonant coupling of multiple transverse cavity modes to different atomic transitions that are well-separated in frequency. We numerically investigate the temporal properties of the photonic wavepacket, two-photon interference visibility, and atom-atom entanglement fidelity under various cavity polarization-mode splittings and find that our scheme is less affected by cavity birefringence. Finally, we propose practical implementations in two trapped ion systems, using the fine structure splitting in the metastable D state of 40 Ca + , and the hyperfine splitting in the ground state of 225 Ra + . Furthermore, our study presents an alternative approach for cavity-based quantum networks that is less sensitive to birefringent effects, and is applicable to a variety of atomic and solid-state emitter-cavity interfaces.

Cavity quantum electrodynamics↗

Near‐Field Characterization of Higher‐Order Topological Photonic States at Optical Frequencies

Abstract Higher‐order topological insulators (HOTIs) represent a new type of topological system, supporting boundary states localized over boundaries, two or more dimensions lower than the dimensionality of the system itself. Interestingly, photonic HOTIs can possess a richer physics than their original condensed matter counterpart, supporting conventional HOTI states based on tight‐binding coupling, and a new type of topological HOTI states enabled by long‐range interactions. Here, a new mechanism to establish all‐dielectric infrared HOTI metasurfaces exhibiting both types of HOTI states is proposed, supported by a topological transition accompanied by the emergence of topological Wannier‐type polarization. Two kinds of near‐field experimental studies are performed: i) the solid immersion spectroscopy and ii) near‐field imaging using scattering scanning near‐field optical microscopy to directly observe the topological transition and the emergence of HOTI states of two types. It is shown that the near‐field profiles indicate the displacement of the Wannier center across the topological transition leading to the topological dipole polarization and emergence of the topological boundary states. The proposed all‐dielectric HOTI metasurface offers a new approach to confine the optical field in micro‐ and nano‐scale topological cavities and thus paves the way to achieve a novel nanophotonic technology.

Vakulenko, Anton↗

High framerate and high dynamic range electron microscopy

Methods and systems for acquiring transmission electron microscope video data on a rolling-shutter detector at an enhanced frame rate and without temporal distortions are described. Also described are methods to enhance the dynamic range of image and diffraction data acquired using a transmission electron microscope. The disclosed methods and systems may also be applicable to photon detection and imaging systems.

Bloom, Ruth↗

Tunable quantum emitters on large-scale foundry silicon photonics

Abstract Controlling large-scale many-body quantum systems at the level of single photons and single atomic systems is a central goal in quantum information science and technology. Intensive research and development has propelled foundry-based silicon-on-insulator photonic integrated circuits to a leading platform for large-scale optical control with individual mode programmability. However, integrating atomic quantum systems with single-emitter tunability remains an open challenge. Here, we overcome this barrier through the hybrid integration of multiple InAs/InP microchiplets containing high-brightness infrared semiconductor quantum dot single photon emitters into advanced silicon-on-insulator photonic integrated circuits fabricated in a 300 mm foundry process. With this platform, we achieve single-photon emission via resonance fluorescence and scalable emission wavelength tunability. The combined control of photonic and quantum systems opens the door to programmable quantum information processors manufactured in leading semiconductor foundries.

Larocque, Hugo (ORCID:000900095849780X)↗

A Multiplexed Hybrid Velocimeter

Optical velocimetry systems play a crucial role in studying the dynamic behavior of materials under extreme conditions. Two prominent systems used at the Nevada National Security Site are the velocity interferometer system for any reflector(VISAR) and the photon Doppler velocimeter (PDV) system. Their ability to accurately measure surface motion ranging from 0 to > 20km=s without interacting with material flow enables experimenters to construct thermodynamic equations of state for materials of interest. A number of modifications to VISAR and PDV have taken place over the past five decades, leading to improved performance, increased recording capacity, and a reduction in operational burden. Prior efforts to develop a hybrid velocimeter combining the advantages of both PDV and VISAR into a single diagnostic did not take into account progress in PDV technology or new optical components that had not been developed. This thesis describes the design and implementation of a multiplexed hybrid velocimeter (MHV) based on time-multiplexing techniques, an optical hybrid, and polarization-maintaining fiber and components. Data from experiments, compared with current velocity systems, serve to demonstrate the hybrid's performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗