Search NASA⌕ Search

SEARCH · Search NASA

Results for “Plasma Volume”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Igniter Testing and Development for Liquid Oxygen/Liquid Methane (LOX/LCH4) and Liquid Oxygen/Gaseous Hydrogen (LOX/GH2) Injectors

In support of NASA's efforts to advance methane technology for future exploration missions, two different igniter concepts were developed and tested at NASA's Marshall Space Flight Center for ignition of oxygen/methane propellants. The first type of igniter, an impinging injection, spark-initiated torch igniter (impinging igniter), used traditional spark plug technology to produce a small, but very intense, pulsed plasma as the ignition source. The second type of igniter, a microwave-generated plasma igniter (microwave igniter), used a microwave magnetron to produce a continuous, larger-volume plasma as the ignition source. Two new designs for both types of igniters were leveraged off past oxygen/methane igniter designs that were tested at MSFC and documented in a 2008 JANNAF paper. In this most recent work, the two new igniters were to be tested at the component level as well as inside a liquid oxygen/liquid methane (LOX/LCH4) 40-element swirl coaxial injector. Although the microwave igniter achieved ignition in every test, it encountered technical difficulties that prevented it from being tested with the injector. The impinging igniter required several design iterations as well as testing at different mixture ratios and mass flow rates before reliable operation with minimal ignition delay was achieved. The final design of the impinging igniter was successfully tested in the LOX/LCH4 injector. The same igniter was later re-configured and component-tested to demonstrate reliable ignition of oxygen/hydrogen propellants. Future tests of the impinging igniter will include ignition of a LOX/hydrogen two-stage swirl injector, which is one of several injector concepts being tested in the Lunar Lander Descent Engine Test Bed at MSFC. All igniter and injector tests have been funded by the Propulsion & Cryogenics Advanced Development project managed by Glenn Research Center and sponsored by NASA s Exploration Technology Development Program.

Osborne, Robin J.↗

Effect of dietary sodium on fluid/electrolyte regulation during bed rest

BACKGROUND: A negative fluid balance during bed rest (BR) is accompanied by decreased plasma volume (PV) which contributes to cardiovascular deconditioning. HYPOTHESIS: We hypothesized that increasing dietary sodium while controlling fluid intake would increase plasma osmolality (POSM), stimulate fluid conserving hormones, and reduce fluid/electrolyte (F/E) losses during BR; conversely, decreasing dietary sodium would decrease POSM, suppress fluid conserving hormones, and increase F/E losses. METHODS: We controlled fluid intake (30 ml x kg(-1) x d(-1)) in 17 men who consumed either a 4.0 +/- 0.06 g x d(-1) (174 mmol x d(-1)) (CONT; n = 6), 1.0 +/- 0.02 g x d(-1) (43 mmol x d(-1)) (LS; n = 6), or 10.0 +/- 0.04 g x d(-1) (430 mmol x d(-1)) (HS; n = 5) sodium diet before, during, and after 21 d of 6 degrees head-down BR. PV, total body water, urine volume and osmolality, POSM, and F/E controlling hormone concentrations were measured. RESULTS: In HS subjects, plasma renin activity (-92%), plasma/urinary aldosterone (-59%; -64%), and PV (-15.0%; 6.0 ml x kg(-1); p < 0.05) decreased while plasma atrial natriuretic peptide (+34%) and urine antidiuretic hormone (+24%) increased during BR (p < 0.05) compared with CONT. In LS, plasma renin activity (+166%), plasma aldosterone (+167%), plasma antidiuretic hormone (+19%), and urinary aldosterone (+335%) increased with no change in PV compared with CONT (p < 0.05). Total body water did not change in any of the subjects. CONCLUSIONS: Contrary to our hypothesis, increasing dietary sodium while controlling fluid intake during BR resulted in a greater loss of PV compared with the CONT subjects. Reducing dietary sodium while controlling fluid intake did not alter the PV response during BR compared with CONT subjects.

Clinical Trial↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Constraining the 3He + 3He Gamow energy probed in high energy density plasmas at the National Ignition Facility

Polar-direct-drive implosions at the National Ignition Facility generated large plasma volumes to study the 3He + 3He fusion reaction. The ion temperature, which determines the Gamow peak energy, was constrained by isolating the thermal contribution to the D3He-proton spectral width in a 3He plasma doped with deuterium. X-ray penumbral imaging was used to measure electron temperature, density, and hotspot volume, which was subsequently used to model the spectral broadening from plasma stopping power. Results showed 30% of the D3He-proton spectral width was due to stopping power, with residual flows contributing ≈10%. The 3He temperature was determined as T3He = 12.4 ± 3.2 keV, corresponding to a Gamow energy of 95 ± 14 keV. These experiments achieved the lowest Gamow energy to date for studying 3He + 3He fusion in high energy density plasma, approaching conditions in the Sun.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The effects of horizontal body casting on blood volume, drug responsiveness, and +Gz tolerance in the rhesus monkey

To simulate the weightless condition, eight rhesus monkeys, instrumented with solid-state pressure transducers, were horizontally restrained in body casts for 28 days. Blood volume decreased an average of 13% after 14 days of restraint, due mainly to a drop in plasma volume. Aortic pressure and heart rate responses to norepinephrine and phenylephrine decreased after 14 days of restraint. The monkeys did not show a statistically significant decreased tolerance to a 90 deg sudden upright tilt after horizontal restraint. During the fifth week of casting, four animals were subjected to +Gz acceleration tests on a centrifuge. The acceleration tolerance of the casted monkeys was significantly reduced compared to four similarly instrumented control animals. These findings indicate that the cardiovascular deconditioning associated with simulated weightlessness results from an inability to maintain central blood volume during orthostatic stress.

Dickey, D. T.↗

Development of a Method for Local Electron Temperature and Density Measurements in the Divertor of the JET Tokamak

Plasma volume recombination in the divertor, a process in which charged particles recombine to neutral atoms, contributes to plasma detachment and hence cooling at the divertor target region. Detachment has been observed at JET and other tokamaks and is known to occur at low electron temperatures (T(sub e)<1 eV) and at high electron density (n(sub e)>10(exp 20)/m(exp 3)). The ability to measure such low temperatures is therefore of interest for modelling the divertor. In present work we report development of a new spectroscopic technique for investigation of local electron density (n(sub e)) and temperature (T,) in the outer divertor at JET.

Jupen, C.↗

The rapid destruction of toroidal magnetic surfaces

The operation of ITER will require reliable simulations in order to avoid major damage to the device from disruptions. Disruptions are the sudden breakup of magnetic surfaces across the plasma volume—a fast magnetic reconnection. This reconnection can be caused by the growth of perturbations outside of the plasma core causing an ideal perturbation to the core. This causes an increasing ratio of the maximum to the minimum separation, Δmax/Δmin, between neighboring magnetic surfaces. Magnetic reconnection becomes a dominant process when magnetic field lines can quickly interchange connections over a spatial scale ar. This occurs when Δmax/Δmin≳ar/Δd, where Δd is the scale over which non-ideal effects make magnetic field lines indistinguishable. Traditional reconnection theory is fundamentally different. It is a study of the steady-state cancelation of oppositely directed magnetic field components across a thin layer. During more than sixty years, mathematical implications of Faraday's law have been derived that clarify and constrain the physics of fast magnetic reconnection. These are reviewed because they are not commonly known but are needed to understand and to place in context how an ideal magnetic evolution can cause reconnection to quickly become a dominant process no matter how small Δd/ar may be.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hemopoiesis in the pig-tailed monkey Macaca nemestrina during chronic altitude exposure.

Study of monkeys for 180 days at 3800 m altitude to examine their hemopoietic response. Plasma volume was found to be reduced while red cell volume increased steadily for four to five months. Reduction in mean corpuscular hemoglobin content was observed from day 30 to day 120 at altitude. Total plasma protein concentration was unchanged at altitude, but marked reduction in the albumin/globulin ratio occurred. Total circulating plasma protein and albumin were reduced in amount, whereas nonalbumin protein was unchanged. These results imply loss of albumin coupled with a corresponding loss of water from the blood and maintenance of normal plasma osmotic pressure. The body/venous hematocrit ratio was found to be reduced at altitude, possibly as a consequence of the expanded capillary volume of the body. The hemopoietic responses of the pig-tailed monkey at altitude require at least several months for completion, and closely resemble those seen in man; thus, the monkey can serve well for long-term studies of high-altitude acclimatization.

Buderer, M. C.↗

Cardiovascular regulatory response to lower body negative pressure following blood volume loss

An attempt is made to explain the cardiovascular regulatory responses to lower body negative pressure (LBNP) stress, both in the absence of and following blood or plasma volume loss, the latter being factors regularly observed with short- or long-term recumbency or weightlessness and associated with resulting cardiovascular deconditioning. Analytical expressions are derived for the responses of mean venous pressure and blood volume pooled in the lower body due to LBNP. An analysis is presented for determining the HR change due to LBNP stress following blood volume loss. It is concluded that the reduced orthostatic tolerance following long-term space flight or recumbency can be mainly attributed to blood volume loss, and that the associated cardiovascular responses characterizing this orthostatic intolerance is elicited by the associated central venous pressure response.

Shimizu, M.↗

Parallel plate radiofrequency ion thruster

An 8-cm-diam. argon ion thruster is described. It is operated by applying 100 to 160 Mhz rf power across a thin plasma volume in a strongly divergent static magnetic field. No cathode or electron emitter is required to sustain a continuous wave plasma discharge over a broad range of propellant gas flow. Preliminary results indicate that a large fraction of the incident power is being reflected by impedance mismatching in the coupling structure. Resonance effects due to plasma thickness, magnetic field strength, and distribution are presented. Typical discharge losses obtained to date are 500 to 600 W per beam ampere at extracted beam currents up to 60 mA.

Nakanishi, S.↗

Mechanism of thirst attenuation during head-out water immersion in men

The purpose was to determine whether extracellular volume or osmolality was the major contributing factor for reduction of thirst in air and head-out water immersion in hypohydrated subjects. Eight males (19-25 yr) were subjected to thermoneutral immersion and thermoneutral air under two hydration conditions without further drinking: euhydration in water (Eu-H2O) and euhydration in air, and hypohydration in water (Hypo-H2O) and hypohydration in air (3.7% wt loss after exercise in heat). The increased thirst sensation with Hypo-H2O decreased (P < 0.05) within 10 min of immersion and continued thereafter. Mean plasma osmolality (288 +/- 1 mosmol/kgH2O) and sodium (140 +/- 1 meq/l) remained elevated, and plasma volume increased by 4.2 +/- 1.0% (P < 0.05) throughout Hypo-H2O. A sustained increase (P < 0.05) in stroke volume accompanied the prompt and sustained decrease in plasma renin activity and sustained increase (P < 0.05) in plasma atrial natriuretic peptide during Eu-H2O and Hypo-H2O. Plasma vasopressin decreased from 5.3 +/- 0.7 to 2.9 +/- 0.5 pg/ml (P < 0.05) during Hypo-H2O but was unchanged in Eu-H2O. These findings suggest a sustained stimulation of the atrial baroreceptors and reduction of a dipsogenic stimulus without major alterations of extracellular osmolality in Hypo-H2O. Thus it appears that vascular volume-induced stimuli of cardiopulmonary baroreceptors play a more important role than extracellular osmolality in reducing thirst sensations during immersion in hypohydrated subjects.

NASA Center ARC↗

Mechanism of Thirst Attenuation During Head-Out Water Immersion in Men

The purpose was to determine whether extracellular volume or osmolality was the major contributing factor for reduction of thirst in air and head-out water immersion in hypohydrated subjects. Eight males (19 - 25 yr) were subjected to thermoneutral immersion and thermoneutral air under two hydration conditions without further drinking: euhydration in water (Eu-H2O) and euhydration in air, and hypohydration in water (Hypo-H2O) and hypohydration in air (3.7% wt loss after exercise in heat). The increased thirst sensation with Hypo-H2O decreased (P less than 0.05) within 10 min of immersion and continued thereafter. Mean plasma osmolality (288 +/- 1 mosmol/kg H2O) and sodium (140 +/- 1 meq/1) remained elevated, and plasma volume increased by 4.2 +/- 1.0% (P less than 0.05) throughout Hypo-H2O. A sustained increase (P less than 0.05) in stroke volume accompanied the prompt and sustained decrease in plasma renin activity and sustained increase (P less than 0.05) in plasma atrial natriuretic peptide during Eu-H2O and Hypo-H2O. Plasma vasopressin decreased from 5.3 +/- 0.7 to 2.9 +/- 0.5 pg/ml (P less than 0.05) during Hypo-H2O but was unchanged in Eu-H2O. These findings suggest a sustained stimulation of the atrial baroreceptors and reduction of a dipsogenic stimulus without major alterations of extracellular osmolality in Hypo-H2O. Thus it appears that vascular volume induced stimuli of cardiopulmonary baroreceptors play a more important role than extracellular osmolality in reducing thirst sensations during immersion in hypohydrated subjects. Thus the purpose for this study was to determine the relative importance of volume and osmotic stimuli, and associated hormonal interaction, for attenuation of thirst during immersion.

Wada, F.↗

Low- n stability and plasma response to RMP in various STEP scenarios

The low-n (n is the toroidal mode number) magnetohydrodynamic (MHD) stability and plasma response are numerically investigated for various scenarios designed for STEP, that are relevant for the H-mode pedestal analysis. Control of the edge-localized modes (ELMs) with externally applied resonant magnetic perturbations (RMPs) is considered. Optimization of the ELM control coil current configuration, based on the computed plasma MHD response and well-established figures of merit validated on present-day experiments, finds reasonable robustness of a fixed coil phasing (for a given n-number) to control ELMs in all five STEP plasmas considered. Based on certain semi-empirical criteria, the required coil current to achieve ELM suppression is estimated to be about 10–20 kAt with the n = 1 or 2 RMP configuration and about 100–200 kAt for the n = 4 RMP. Systematic linear stability calculations are used to map out stability windows for the low-n kink-peeling modes, in terms of the ideal-wall location and variation of the edge safety factor q 95 with respect to the target design. The kink-peeling stability boundary is found to be generally sensitive to the q 95 variation, which has implications for achieving the quiescent H-mode regime in STEP. Full toroidal quasilinear initial-value simulations for these STEP plasmas find that generation of the edge-harmonic oscillations (EHOs) depends sensitively on the plasma scenario, the initial linear stability of the kink-peeling modes, the initial plasma toroidal flow and q 95 . In general, it is easier (more robust) to access the EHO-regime for two of the cases considered with smaller plasma volume and higher on-axis safety factor. Finally, quasilinear simulations find robust density pumpout due to applied RMPs in these STEP plasmas, but the effect on the plasma toroidal flow varies among different cases.

EHO↗

Examining Individual Differences in Temporal Profiles of Cardiovascular Responses to the Head Down Tilt during Fluid Loading

Upon returning to Earth after an extended exposure to micro-gravity in space many astronauts have experienced symptoms of light headedness and fainting associated with post-flight orthostatic intolerance (low blood pressure). The main reason for this condition is the reduced fluid volume in the body while in space. A preventative treatment was proposed to prevent this condition by fluid loading to restore lost plasma volume by giving crew members salt tablets and water prior to re-entry. In order to simulate micro-gravity effects on earth test subjects are placed in a supine position with their head below the level of their heart (6 head down tilt-HDT). The purpose of the present study is to define individual differences in the time course of cardiac stroke volume responses to HDT (6 hours) and the effectiveness of fluid loading for mitigating orthostatic intolerance when standing . Echocardiography and impedance cardiography data will be collected on 8 men and 8 women to examine heart function to HDT. A second objective is to determine if the effects of fluid loading vary due to individual differences (e.g., age, gender, height, weight, physical fitness, etc.).

orthostatic intolerance↗

Hypovolemia Induced Orthostatic Hypotension in Presyncopal Astronauts and Normal Subjects Related to Hypoadrenergic Responsiveness

Circulating blood volume is reduced during spaceflight, making astronauts hemodynamically compromised. After landing, astronauts separate into two groups. One group compensates for the hypovolemia with a hyper-sympathetic response during upright tilt testing and can complete a tilt test with few symptoms. The other group is unable to mount a hyper-sympathetic response and experiences orthostatic hypotension and presyncope during upright tilt tests. We tested the hypothesis that hypovolemia alone, in the absence of spaceflight, also would cause subjects to separate into presyncopal and non-presyncopal groups according to their sympathetic responses during tilt. We studied 20 subjects, including 10 veteran astronauts, on three occasions. On Days 1 (normovolemia) and 3 (hypovolemia), plasma volume, tilt tolerance and supine and standing plasma norepinephrine levels were measured. Forty hours prior to Day 3, subjects were given intravenous furosemide, followed by 36 hours of a 10MEq Na diet. Statistical comparisons were made between normovolemia and hypovolemia responses. This protocol reproduced landing day tilt test outcomes with 100% fidelity in the astronauts. Similarly to patterns reported after flight, non-presyncopal subjects had greater norepinephrine responses to tilt during hypovolemia compared to normovolemia (580 plus or minus 79 vs. 298 plus or minus 37 pg/ml, P less than 0.05), but presyncopal subjects had no increase (180 plus or minus 44 vs. 145 plus or minus 32 pg/ml, P=NS). This model can be used to predict astronauts who will become presyncopal on landing day, so that prospective, individualized countermeasures can be developed. Within patient populations, it can be used to study the interaction of volemic state and the sympathetic nervous system.

Meck, Janice V.↗

Causes and consequences of reduced blood volume in space flight - A multi-discipline modeling study

A group of mathematical models of various physiological systems have been developed and applied to studying problems associated with adaptation to weightlessness. One biomedical issue which could be addressed by at least three of these models from varying perspectives was the reduction in blood volume that universally occurs in astronauts. Accordingly, models of fluid-electrolyte, erythropoiesis, and cardiovascular regulation were employed to study the causes and consequences of blood volume loss during space flight. This analysis confirms the notion that alterations of blood volume are central to an understanding of adaptation to prolonged space flight. More importantly, the modeling studies resulted in specific hypotheses accounting for plasma volume and red cell mass losses and testable predictions concerning the behavior of the circulatory system.

Leonard, J. I.↗

Physiologic mechanisms of circulatory and body fluid losses in weightlessness identified by mathematical modeling

Central volume expansion due to fluid shifts in weightlessness is believed to activate adaptive reflexes which ultimately result in a reduction of the total circulating blood volume. However, the flight data suggests that a central volume overdistention does not persist, in which case some other factor or factors must be responsible for body fluid losses. We used a computer simulation to test the hypothesis that factors other than central volume overdistention are involved in the loss of blood volume and other body fluid volumes observed in weightlessness and in weightless simulations. Additionally, the simulation was used to identify these factors. The results predict that atrial volumes and pressures return to their prebedrest baseline values within the first day of exposure to head down tilt (HDT) as the blood volume is reduced by an elevated urine formation. They indicate that the mechanisms for large and prolonged body fluid losses in weightlessness is red cell hemoconcentration that elevates blood viscosity and peripheral resistance, thereby lowering capillary pressure. This causes a prolonged alteration of the balance of Starling forces, depressing the extracellular fluid volume until the hematocrit is returned to normal through a reduction of the red cell mass, which also allows some restoration of the plasma volume. We conclude that the red cell mass becomes the physiologic driver for a large 'undershoot' of the body fluid volumes after the normalization of atrial volumes and pressures.

Simanonok, K. E.↗

Drinking-Induced Plasma Vasopressin and Norepinephrine Changes in Dehydrated Humans

After 24-h water deprivation, five men (23-41 yr; 78 +/- 3.6 kg) consumed, within 4.0-6.2 min, 12 mL/kg of one of six fluid formulations (16.5 C) once a week over a period of 6 weeks: water, hypotonic saline (0.045% Na(+)), isotopic saline (0.36%, Na(+)), hypertonic glucose 9 7%, glucose), and two commercial mildly hypertonic 9.7% carbohydrate drinks. Blood samples were drawn 5 min before and: 3, 9, 15, 30, and 70 min after completion of drinking. Ingestion induced no significant change in plasma Na(+), K(+), osmotic, or protein concentrations, blood pressure; or heart rate. Plasma volume (PV) was increases (P <0.05) between 30-70 min with isotonic saline and the two commercial drinks. Ingestion induced a decrease in plasma AVP (PAVP) at 3 min, which was maximal (P < 0.05) at 15 min with all drinks. Thus, the act of drinking, independent of the composition or osmolality of the fluid absorbed, leads to a prompt inhibition of PAVP secretion in man. With the exception of rehydration with isotonic saline, this prompt response was followed by a long lasting inhibition of PAVP. There was no change in PRA, plasma aldosterone, atrial natriuretic peptide, or epinephrine, but an increase in plasma norepinephrine occurred immediately after ingestion, which suggests, like that for PAVP depression, a drinking-stimulate neural mechanism.

Geelen, Ghislaine↗