Search NASA⌕ Search

SEARCH · Search NASA

Results for “Polarization spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Anti-Stokes scattering as an XUV radiation source

Harris (1977) has shown that laser induced scattering from atoms stored in a metastable level may be used to produce an XUV radiation source with several unique properties, including narrow linewidth, tunability, linear polarization, picosecond pulsewidth, and relatively high peak spectral brightness. The present investigation provides a summary concerning the progress made on the use of this radiation source as a unique instrument for XUV spectroscopy, and as a possible flashlamp for a 200 A laser. Zych et al. (1978) demonstrated that the maximum spectral brightness of the source is that of a blackbody with a temperature of the metastable storage level. The peak count rate and peak spectral brightness of the anti-Stokes emission at 569 A are 17 times and 139 times greater than those of the 584 A resonance line. The anti-Stokes process was employed as an external source of radiation for high resolution spectroscopy of the 3p6 shell of potassium. Attention is also given to emission spectroscopy of lithium, metastable levels which are appropriate for storage, and a hollow cathode discharge.

Harris, S. E.↗

MOPITT - A gas correlation spectrometer for tropospheric Earth observations

MOPITT (Measurement of Pollution in the Troposphere) is an instrument that will fly on the EOS AM-1 Polar Orbiting Platform, to be launched in mid-1998. The instrument accurately measures the concentration of carbon monoxide (CO) and methane (CH4) gas in the troposphere, using novel and conventional gas correlation spectroscopy techniques. These techniques are used to measure both the column amount and the vertical profile of the two gases in the troposphere. The instrument is nadir viewing and has cross-track scanning ability. It measures upwelling IR radiation through the atmosphere in the 4.6-micron and 2.3-micron bands for CO detection, and 2.2-micron for CH4. The instrument performance is enhanced using Stirling cycle mechanical coolers to maintain the IR detectors at less than 100 K. MOPITT has a total of eight detector channels to measure the total column of atmospheric CH4 gas to a precision of 1 percent, and to measure CO profiles to a precision of 10 percent. The instrument is self-calibrating to ensure data validity using internal targets and an external cold space view.

Drummond, James R.↗

Exoplanet Imaging with CHARIS and Future Synergies with WFIRST CGI

The principal science goal of directly imaging exoplanets is spectroscopy. At Subaru, the SCExAO instrument uses the CHARIS integral field spectrograph (IFS) to take spectra of young, self-luminous companions and disks in the near-infrared. CHARIS provides both R70 and R20 spectral resolutions across the J, H, and K bands. Of the two, R20 is the primary observing mode, which provides both excellent spectral coverage of the companions and a larger bandpass for advanced speckle subtraction techniques. Looking to the future, the WFIRST CoronaGraph Instrument (CGI) is a technology demonstration for future missions whose spectroscopic techniques are rooted in what has been demonstrated at ground observatories. CGI will reach very high contrast in broadband light with advanced wavefront control and coronagraphy techniques, paving the way for characterizing Earth-like planets. The spectral resolution of CGI spectroscopic modes is R50 with 15% bandpasses from 600 to 970nm. The calibration, speckle subtraction, and spectral extraction methods for CGI spectroscopy has a strong heritage from techniques developed for SCExAO+CHARIS. We discuss such synergies between CHARIS and CGI characterization capabilities from both a science and engineering perspective, including the new Wollaston polarization upgrade to CHARIS.

Groff, Tyler D.↗

Sulfur dioxide at the Venus cloud tops, 1978-1986

Ultraviolet spectroscopy from the Pioneer Venus Orbiter shows a decline in the cloud top abundance of SO2 from about 100 ppb to about 10 ppb in the period 1978-1986. A consistent decline in polar haze has occurred over the same period, with the correlation coefficient between these two observables of r = 0.8. Star calibrations determine the instrument sensitivity to within 10 percent which rules out the possibility that this is an instrumental effect. Systematic errors could increase the SO2 abundance to twice the inferred values in later orbits. Tracking of SO2 features and power spectral analysis give rotation periods for the longer-lived features of 3.6-5.2 days, consistent with cloud-tracked winds observed at other wavelengths. The behavior of SO2 and polar haze can be plausibly explained by episodic injection of SO2 into the cloud top regions, for example, by active volcanism.

Esposito, Larry W.↗

Sulfur dioxide and its variations

UV spectroscopy from the Pioneer Venus Orbiter shows a decline in the cloud top abundance of SO2 from about 100 ppb to about 10 ppb in the period 1978-1986. A consistent decline in polar haze has occurred over the same period with the correlation coefficient between these two observables of 0.8. Star calibrations determine the instrument sensitivity to within 10 percent, which rules out the possibility that this is an instrumental effect. Systematic errors could increase the SO2 abundance to twice the inferred values in later orbits. Tracking of SO2 features and power spectral analysis give rotation periods for the longer lived features of 3.6-5.2 d, consistent with cloud tracked winds observed at other wavelengths. The behavior of SO2 and polar haze can be plausibly explained by episodic injection of SO2 into the cloud top regions, for example, by active volcanism.

Esposito, Larry W.↗

The reddening and variability of XX Ophiuchi

We present polarization data on the XX Oph system which suggest that the interstellar extinction to this object has been overestimated in the past: our data imply A(V) = 1.6 mag. Our photometry and infrared spectroscopy suggest a spectral class of M7III for the late component, and a BOV companion that ionizes the wind of the cool component. XX Oph seems more like a Zeta Aur/VV Cep system than a 'symbiotic object'. The photometric variability of XX Oph seems to have a number of causes, ranging from shell-type variability in the U band to variations in the M component in the infrared.

Evans, A.↗

ASTRO-2 Spacelab Instrument Pointing System mission performance

This paper reports the performance of the Instrument Pointing System (IPS) that flew on the National Aeronautics and Space Administration (NASA) ASTRO-2 Spacelab mission aboard the Space Shuttle Endeavour in March 1995. The IPS provides a stabilizing platform for the ASTRO-2 instrument payload complement that consists of three main experiments (telescopes). The telescopes observe stellar targets in the universe within the ultraviolet portion of the electromagnetic spectrum that must be observed from beyond the earth's atmospheric filtering effects. The three main experiments for observation are the Hopkins Ultraviolet Telescope (HUT), the Ultraviolet Imaging Telescope (UIT), and the Wisconsin Ultraviolet Photo-Polarimetry Experiment (WUPPE). The HUT uses spectroscopy to obtain the structure and chemical makeup of ultraviolet targets. UIT is responsible for wide field photographing to capture the hidden view of the ultraviolet universe. The WUPPE gathers data on the polarization of the ultraviolet electromagnetic energy coming from the astronomical targets. The capability of IPS enables the experiments to 'see' faint celestial objects. A brief explanation of the IPS is given followed by a review of engineering efforts to improve IPS performance over the ASTRO-1 mission. The main focus of improvements was on enhancing the star acquisition capability through improved guide star selection, lab simulations, computer upgrades, data display systems improvements, and software modifications. A star simulator was developed in the lab to enable IPS to be simulated on the ground pre-mission with flight hardware and software in the loop. The paper concludes with results from the ASTRO-2 mission. The number of targets acquired and the IPS pointing accuracy/stability is reported along with recommendations for the future use of the Instrument Pointing System.

Wessling, Francis C., III↗

ATMOS Measurements of H2O + 2CH4 and Total Reactive Nitrogen in the November 1994 Antarctic Stratosphere: Dehydration and Denitrification in the Vortex

Simultaneous stratospheric volume mixing ratios (VMR's) measured inside and outside the Antarctic vortex by the Atmospheric Trace Molecule Spectroscopy (ATMOS) instrument in November 1994 reveal previously unobserved features in the distributions of total reactive nitrogen (NO(y)) and total hydrogen (H2O + 2CH4). Maximum removal of NO(y) due to sedimentation of polar stratospheric clouds (PSC's) inside the vortex occurred at a potential temperature (Theta) of 500-525 K (approximately 20 km), where values were 5 times smaller than measurements outside. Maximum loss of H2O + 2CH4 due to PSC's occurred in the vortex at 425-450 K, approximately 3 km lower than the peak NO(y) loss. At that level, H2O + 2CH4 VMR's inside the vortex were approximately 70% of corresponding values outside. The Antarctic and April 1993 Arctic measurements by ATMOS show no significant differences in H2O + 2CH4 VMR's outside the vortices in the two hemispheres. Elevated NO(y) VMRs were measured inside the vortex near 700 K. Recent model calculations indicate that this feature results from downward transport of elevated NO(y) produced in the thermosphere and mesosphere.

Rinsland, C. P.↗

Circular polarimetry of EXO 033319-2554.2 - A new eclipsing AM Herculis star

This Letter presents circular polarimetry that unequivocally identifies EXO 033319-2554.2 as only the third eclipsing AM Her star and brings the total number of AM Her stars now identified to 14. The orbital period is 126.4 minutes, as previously reported, and defines a new short-period edge to the period gap seen in all classes of cataclysmic variable stars. EXO 033319-2554.2 shows 2.5 mag deep eclipses of the predominantly accreting magnetic pole on the white dwarf. Before the eclipse, the pole rotates into the line of sight and shows white-light circular polarization, due to cyclotron radiation, that reaches values as high as 10 percent. There is some evidence that the second pole is emitting cyclotron radiation too. How high time resolution photometry, linear polarimetry, and spectroscopy will be of great value in understanding this system.

Berriman, Graham↗

Laboratory studies of chemical and photochemical processes relevant to stratospheric ozone

The purpose of this project is to reduce the uncertainty in several key gas-phase kinetic processes which impact our understanding of stratospheric ozone. The main emphasis of this work is on measuring rate coefficients and product channels for reactions of HO(sub x) and NO(sub x) species in the temperature range 200 K to 240 K relevant to the lower stratosphere. Other areas of study have included infrared spectroscopic studies of the HO2 radical, measurements of OH radical reactions with alternative fluorocarbons, and determination of the vapor pressures of nitric acid hydrates under stratospheric conditions. The results of these studies will improve models of stratospheric ozone chemistry and predictions of perturbations due to human influences. In this annual report, we focus on our recent accomplishments in the quantitative spectroscopy of the HO2 radical. This report details the measurements of the broadening coefficients for the v(sub 2) vibrational band. Further measurements of the vapor pressures of nitric acid hydrates relevant to the polar stratospheric cloud formation indicate the importance of metastable crystalline phases of H2SO4, HNO3, and H2O. Large particles produced from these metastable phases may provide a removal mechanism for HNO3 in the polar stratosphere.

Zahniser, Mark S.↗

Strain Dependence of Photoluminescense of Individual Carbon Nanotubes

We have investigated strain dependence of photoluminescense (PL) spectra of single wall carbon nanotubes (SWNT). Nanotubes were sparsely dispersed in a thin PMMA film applied to acrylic bar, and strained in both compression and extension by bending this bar in either direction in a homebuilt four-point bending rig. The average surface strain was measured with high accuracy by a resistive strain gage applied on top of the film. The near infrared imaging and spectroscopy were performed on the inverted microscope equipped with high numerical aperture reflective objective lens and InGaAs CCD cameras. PL was excited with a diode laser at either 658, 730 or 785 nm, linearly polarized in the direction of the strain. We were able to measure (n,m) types and orientation of individual nanotubes with respect to strain direction and strain dependence of their PL maxima. It was found that PL peak shifts with respect to the values measured in SDS micelles are a sum of three components. First, a small environmental shift due to difference in the dielectric constant of the surrounding media, that is constant and independent of the nanotube type. Second, shift due to isotropic compression of the film during drying. Third, shifts produced by the uniaxial loading of the film in the experiment. Second and third shifts follow expression based on the first-order expansion of the TB hamiltonian. Their magnitude is proportional to the nanotube chiral angle and strain, and direction is determined by the nanotube quantum number. PL strain dependence measured for a number of various nanotube types allows to estimate TB carbon-carbon transfer integral.

Nikolaev, Pavel N.↗

The Faint Object Camera

The Faint Object Camera fully exploits the spatial resolution capability of the Space Telescope on the very faintest detectable objects over a broad wavelength range. A full complement of filters, objective prisms and polarizers, a choice of coronograhic masks, and a variety of scan formats extend the scientific versatility of the direct imaging mode. In addition, the Faint Object Camera provides the unique facility of long-slit spectroscopy to Space Telescope observers.

Macchetto, F.↗

Nuclear techniques in studies of condensed matter

Nuclear techniques have played an important role in the studies of materials over the past several decades. For example, X-ray diffraction, neutron diffraction, neutron activation, and particle- or photon-induced X-ray emission techniques have been used extensively for the elucidation of structural and compositional details of materials. Several new techniques have been developed recently. Four such techniques are briefly reviewed which have great potential in the study and development of new materials. Of these four, Mossbauer spectroscopy, muon spin rotation, and positron annihilation spectroscopy techniques exploit their great sensitivity to the local atomic environments in the test materials. Interest in synchrotron radiation, on the other hand, stems from its special properties, such as high intensity, high degree of polarization, and high monochromaticity. It is hoped that this brief review will stimulate interest in the exploitation of these newer techniques for the development of improved materials.

Singh, Jag J.↗

Lunar and Planetary Science XXXVI, Part 18

Topics discussed include: PoDS: A Powder Delivery System for Mars In-Situ Organic, Mineralogic and Isotopic Analysis Instruments Planetary Differentiation of Accreting Planetesimals with 26Al and 60Fe as the Heat Sources Ground-based Observation of Lunar Surface by Lunar VIS/NIR Spectral Imager Mt. Oikeyama Structure: First Impact Structure in Japan? Central Mounds in Martian Impact Craters: Assessment as Possible Perennial Permafrost Mounds (Pingos) A Further Analysis of Potential Photosynthetic Life on Mars New Insight into Valleys-Ocean Boundary on Mars Using 128 Pixels per Degree MOLA Data: Implication for Martian Ocean and Global Climate Change; Recursive Topography Based Surface Age Computations for Mars: New Insight into Surficial Processes That Influenced Craters Distribution as a Step Toward the Formal Proof of Martian Ocean Recession, Timing and Probability; Laser-induced Breakdown Spectroscopy: A New Method for Stand-Off Quantitative Analysis of Samples on Mars; Milk Spring Channels Provide Further Evidence of Oceanic, >1.7-km-Deep Late Devonian Alamo Crater, Southern Nevada; Exploration of Martian Polar Residual Caps from HEND/ODYSSEY Data; Outflow Channels Influencing Martian Climate: Global Circulation Model Simulations with Emplaced Water; Presence of Nonmethane Hydrocarbons on Pluto; Difference in Degree of Space Weathering on the Newborn Asteroid Karin; Circular Collapsed Features Related to the Chaotic Terrain Formation on Mars; A Search for Live (sup 244)Pu in Deep-Sea Sediments: Preliminary Results of Method Development; Some Peculiarities of Quartz, Biotite and Garnet Transformation in Conditions of Step-like Shock Compression of Crystal Slate; Error Analysis of Remotely-Acquired Mossbauer Spectra; Cloud Activity on Titan During the Cassini Mission; Solar Radiation Pressure and Transient Flows on Asteroid Surfaces; Landing Site Characteristics for Europa 1: Topography; and The Crop Circles of Europa.

Source record↗

Columbia University OSO-8 instrument for stellar and solar X-ray spectroscopy and polarimetry

A spectrometer and a polarimeter consisting of large-area panels of mosaic crystals have been constructed and prepared for use in the OSO-8 satellite. The instrumentation is planned for study of stellar and solar X-ray spectra between 1.8-8 keV and stellar X-ray polarization at 2.6 keV. Aspects of the design which enable the instrument to make measurements of the diverse range of stellar and solar phenomena are described. Some of the unique features, such as high sensitivity, high temporal resolution, and spectral range, are discussed. The applicability of the spectrometer and polarimeter to various current problems in X-ray astronomy is considered.

Wolff, R. S.↗

Qualitative Headspace GCMS Analysis of Lunar Regolith and Volatile Simulant Mixtures

Introduction: Future Artemis missions aim to return the volatile-bearing samples collected near lunar polar craters. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving the integrity of returned samples and the science value those samples contain. The extent to which that preservation is possible, and the trade-offs preservation requires (e.g. monetary costs, sample volume limitations) all must be considered. Even less-than pristine volatile-bearing samples will be of tremendous value to the scientific community seeking to unravel the history of lunar surface volatiles and, more broadly, volatiles in the solar system. A sample collected on the lunar surface will experience at least five distinctive periods during which any changes here referred to as “alteration” will certainly occur at some scale: collection on the lunar surface; transportation back to Earth; long-term storage; curatorial processing; and allocation/distribution. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on returned volatile samples by working with high-fidelity volatile-containing regolith simulants, setting the foundation for the future of cold curation. This abstract is focused on gas-surface interactions between LCROSS volatiles and readily available lunar regolith simulants. Experiments involved analyzing differences in headspace gas composition for various combinations of volatile and regolith simulants using gas chromatography/mass spectrometry (GC/MS). Experimental Procedure: The volatile simulants were chosen based on the molecules detected during the LCROSS mission.1 Stock solutions of condensed lunar volatile analytes were: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. The regolith simulants used were primarily JSC-1A and NU-LHT-4M. Additional regolith simulant control studies were conducted with <150 μm sieved sand and KBr. A nested vial sample preparation approach separated the liquid stock solutions from the regolith, eliminating potential matrix effects between liquid and solid phases. Fifteen microliter aliquots of liquid volatile simulants were added to a 2 mL liquid GC vial and capped in atmosphere. An 18G needle punctured the 2 mL GC vial immediately before being transferred and sealed in a 20 mL GC vial containing 0-0.3 g of regolith simulant, see Figure 1. Separating the analytes ensures any changes observed in the total headspace gases is a result of gas-surface and/or gas-gas interactions. Equipment and Method: Initial GC/MS method development for the separation and identification of relevant headspace gases can be found in Amick, et al. 2023.2 The only hardware change is a different column: a TG-1701MS 30 m × 0.25 mm × 1.00 μm column. The vials were sampled at 10°C, room temperature (~25°C) and 50°C. Low temperature samples were kept in a chilled autosampler stage for at least 1 hour prior to sampling. High temperature samples were agitated at 50°C for 5 minutes immediately prior to injection onto the column. Headspace chromatograms were collected for each combination of temperature, regolith, and volatile simulant, including controls without one or both types of analytes, in triplicate. The chromatogram elution window for each analyte or significant atmospheric gas was identified using the peak mass spectrum cross-referenced with Figure 1.Picture of the nested vial set-up. a NIST MS library search. Each analyte peak was integrated after filtering the mass spectrum trace for the parent or most unique mass-to-charge ratio. For example, the mass-to-charge ratio used to identify, filter for, and integrate the carbon dioxide peak was centered around 44 m/z. Results: Figure 2 shows the integrated peak area for hydrogen sulfide in all combinations of regolith simulants, temperatures, and the addition of ammonia in methanol solution. Multiple repeat experiments with H2S and regolith simulants have confirmed hydrogen sulfide is removed from the headspace within 1 hour when exposed to JSC-1A, NU-LHT-4M and sand (not pictured). The consumption of H2S by lunar regolith simulants at different temperatures indicates surface chemistry will be an integral component in sample integrity and preservation. It is important to note that while the effect of surface chemistry on gaseous hydrogen sulfide is intriguing, further investigation into more chemically accurate regolith simulants is necessary and ongoing. The sulfur in hydrogen sulfide is in its most reduced state while off-the-shelf, terrestrially sourced JSC-1A and NU-LHT-4M are more oxidized than most lunar materials,3which likely leads to different oxidation-reduction reactions than would be expected in lunar regolith. Figure 3 shows the integrated peak area of carbon dioxide for each sample combination that contained ammonia in methanol solution. The addition of ammonia to the GC vials results in a consistent and reproducible decrease in carbon dioxide gas, even at 50°C. The effect became more pronounced when JSC-1A or NU-LHT-4M were present. This set of experiments demonstrated that the sample composition will affect the chemical and physical state of each component present. Future spectroscopic and microscopy experiments will be geared towards identifying the cause for the CO2(g) concentration decrease and the consumption of hydrogen sulfide. As cold and volatile curation scientists, this information provides necessary insight on how to appropriately handle and analyze volatile bearing returned samples, as well as predict the effect chemical composition has on the various sample phases we will analyze upon return to Earth. Unlike traditional curation of geologic materials, the molecules in a sample cannot be identified or processed using the naked eye or even an optical microscope. Volatile curation will require a combination of analytical techniques, including but not limited to highly sensitive gas and solid/condensed phase spectroscopy. This set of experiments has demonstrated the need for more detailed studies of volatile mixtures with mineralogically and geochemically analogous lunar regolith simulants to prepare for the curation of volatile-rich lunar samples from the south polar region of the Moon. References: [1] Colaprete, A., et al. (2010) Science, 330, (463-468). [2] Amick, C. L., et al.(2023) Houston, Texas, [3] Heiken, G. H., et al.(1991) (778-778)

Cecilia L Amick↗

A Novel Application of Fourier Transform Spectroscopy with HEMT Amplifiers at Microwave Frequencies

The goal was to develop cryogenic high-electron-mobility transistor (HEMT) based radiometers and use them to measure the anisotropy in the cosmic microwave background (CMB). In particular, a novel Fourier transform spectrometer (FTS) built entirely of waveguide components would be developed. A dual-polarization Ka-band HEMT radiometer and a similar Q-band radiometer were built. In a series of measurements spanning three years made from a ground-based site in Saskatoon, SK, the amplitude, frequency spectrum, and spatial frequency spectrum of the anisotropy were measured. A prototype Ka-band FTS was built and tested, and a simplified version is proposed for the MAP satellite mission. The 1/f characteristics of HEMT amplifiers were quantified using correlation techniques.

Wilkinson, David T.↗

A Possible X-Ray and Radio Counterpart of the High-Energy Gamma-Ray Source 3EG J2227+6122

The identity of the persistent EGRET sources in the Galactic plane is largely a mystery. For one of these, 3EG J2227+6122, our complete census of X-ray and radio sources in its error circle reveals a remarkable superposition of an incomplete radio shell with a flat radio spectrum, and a compact, power-law X-ray source with photon index Gamma = 1.5 and with no obvious optical counterpart. The radio shell is polarized at a level of approx. = 25%. The anomalous properties of the radio source prevent us from deriving a completely satisfactory theory as to its nature. Nevertheless, using data from ROSAT, ASCA, the VLA, and optical imaging and spectroscopy, we argue that the X-ray source may be a young pulsar with an associated wind-blown bubble or bow shock nebula, and an example of the class of radio-quiet pulsars which are hypothesized to comprise the majority of EGRET sources in the Galaxy. The distance to this source can be estimated from its X-ray absorption as 3 kpc. At this distance, the X-ray and gamma-ray luminosities would be approx. = 1.7 x 10(exp 33) and approx. = 3.7 x 10(exp 35) erg/s, respectively, which would require an energetic pulsar to power them. If, on the contrary, this X-ray source is not the counterpart of 3EG J2227+6122, then by process of elimination the X-ray luminosity of the latter must be less than 10(exp -4) of its gamma-ray luminosity, a condition not satisfied by any established class of gamma-ray source counterpart. This would require the existence of at least a quantitatively new type of EGRET source, as has been suggested in studies of other EGRET fields.

Halpern, Jules P.↗