Search NASA⌕ Search

SEARCH · Search NASA

Results for “Portable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Portable, heterogeneous ensemble workflows at scale using libEnsemble

libEnsemble is a Python-based toolkit for running dynamic ensembles, developed as part of the DOE Exascale Computing Project. The toolkit utilizes a unique generator–simulator–allocator paradigm, where generators produce input for simulators, simulators evaluate those inputs, and allocators decide whether and when a simulator or generator should be called. The generator steers the ensemble based on simulation results. Generators may, for example, apply methods for numerical optimization, machine learning, or statistical calibration. libEnsemble communicates between a manager and workers. Flexibility is provided through multiple manager–worker communication substrates each of which has different benefits. These include Python’s multiprocessing, mpi4py, and TCP. Multisite ensembles are supported using Balsam or Globus Compute. We overview the unique characteristics of libEnsemble as well as current and potential interoperability with other packages in the workflow ecosystem. We highlight libEnsemble’s dynamic resource features: libEnsemble can detect system resources, such as available nodes, cores, and GPUs, and assign these in a portable way. These features allow users to specify the number of processors and GPUs required for each simulation; and resources will be automatically assigned on a wide range of systems, including Frontier, Aurora, and Perlmutter. Such ensembles can include multiple simulation types, some using GPUs and others using only CPUs, sharing nodes for maximum efficiency. We also describe the benefits of libEnsemble’s generator–simulator coupling, which easily exposes to the user the ability to cancel, and portably kill, running simulations based on models that are updated with intermediate simulation output. We demonstrate libEnsemble’s capabilities, scalability, and scientific impact via a Gaussian process surrogate training problem for the longitudinal density profile at the exit of a plasma accelerator stage. In conclusion, the study uses gpCAM for the surrogate model and employs either Wake-T or WarpX simulations, highlighting efficient use of resources that can easily extend to exascale.

Dynamic ensembles↗

Performance Portability of HPC Discovery Science Software: Fusion Energy Turbulence Simulations at Extreme Scale

As HPC R&D moves forward on a variety of “path to exascale” architectures today, an associated objective is to demonstrate performance portability of discovery-science-capable software. Important application domains, such as Magnetic Fusion Energy (MFE), have improved modelling of increasingly complex physical systems -- especially with respect to reducing “time-to-solution” as well as “energy to solution.” The emergence of new insights on confinement scaling in MFE systems has been aided significantly by efficient software capable of harnessing powerful supercomputers to carry out simulations with unprecedented resolution and temporal duration to address increasing problem sizes. Specifically, highly scalable particle-in-cell (PIC) programing methodology is used in this paper to demonstrate how modern scientific applications can achieve efficient architecture-dependent optimizations of performance scaling and code portability for path-to-exascale platforms.

97 MATHEMATICS AND COMPUTING↗

Singularity-EOS: Performance Portable Equations of State and Mixed Cell Closures

We present Singularity-EOS, a new performance-portable library for equations of state and related capabilities. Singularity-EOS provides a large set of analytic equations of state, such as the Gruneisen equation of state, and tabulated equation of state data under a unified interface. It also provides support capabilities around these equations of state, such as Python wrappers, solvers for finding pressure-temperature equilibrium between multiple equations of state, and a unique modifier framework, allowing the user to transform a base equation of state, for example by shifting or scaling the specific internal energy. All capabilities are performance portable, meaning they compile and run on both CPU and GPU for a wide variety of architectures.

97 MATHEMATICS AND COMPUTING↗

Portable Radiation Package (PRP) Instrument Handbook

The Portable Radiation Package (PRP) was developed to provide basic radiation information in locations such as ships at sea where proper exposure is remote and difficult, the platform is in motion, and azimuth alignment is not fixed. Development of the PRP began at Brookhaven National Laboratory (BNL) in the mid-1990s and versions of it were deployed on ships in the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility’s Nauru-99 project. The PRP was deployed on ships in support of the National Aeronautics and Space Administration (NASA) Sensor Intercomparison for Marine Biological and Interdisciplinary Ocean Studies (SIMBIOS) program. Over the years the measurements have remained the same while the post-processing data analysis, especially for the FRSR, has evolved. This document describes the next-generation Portable Radiation Package (PRP2) that was developed for the DOE ARM Facility, under contract no. 9F-31462 from Argonne National Laboratory (ANL). The PRP2 has the same scientific principles that were well validated in prior studies, but has upgraded electronic hardware. The PRP2 approach is completely modular, both in hardware and software. Each sensor input is treated as a separate serial stream into the data collection computer. In this way the operator has complete access to each component of the system for purposes of error checking, calibration, and maintenance. The resulting system is more reliable, easier to install in complex situations, and more amenable to upgrade.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

I. Final Report for DOE SBIR Phase I Project DE-SC0013795 Final Report for DOE SBIR Phase I Project DE-SC0013795 Microtron-based Compact, Portable Gamma-Ray Source

Microtron-based Compact, Portable Gamma-Ray Source. The objective of Phase I of this project was to produce a conceptual design of a prototype compact microtron electron accelerator, which could be designed, built, and demonstrated in Phase II of the project. The conceptual design study included an analysis of the parameters of the microtron and its components, and the expected performance of the prototype microtron as a source of x-rays and/or RF neutrons in the MeV energy range. The major components of the microtron are the magnet, the accelerating system, the power system, the vacuum system, the control system, the beam extraction system and the targets to produce x-rays (and/or neutrons). Our objectives for the design of the prototype were for it to be compact, cost-effective, capable of producing high intensity x-ray (an/or neutron) fluxes. In addition, the prototype was to be easily assembled and disassembled so that components could be easily replaced. The main parameters for the prototype are the following: the range of electron kinetic energies, the output power, the RF frequency band (X-band, C-band, or S-Band), the type of injection (Type I or Type II), the magnet type, i.e. permanent magnet, electromagnet, or a hybrid combination of permanent and electromagnet. The results of the Phase I study and analysis for a prototype microtron are the following: The electron energy range can be varied from below 6 MeV to 9 MeV, the optimal frequency range is S-Band (2-4 GHz) RF frequency, Type II injection (described below), and the magnet type is the hybrid version. The prototype version will be capable of producing gamma ray doses of ~1800 R/min-m and neutron fluxes of up to ~6 x 10 10 n/s with appropriate targets. The results of the Phase I study and analysis are provided below. The proposed Phase II plan was to demonstrate the prototype at low beam power. In the subsequent Phase III, high power tests would be performed, and the design of commercial versions of microtrons with various energies, sizes and types would be produced and marketed, including a more compact and more portable 6 MeV battery-powered model that more closely meets the requirements in the original FOA topic description. In the course of the Phase I study, we also identified another microtron version, one that was larger (not compact) and more powerful than that of the Phase II prototype, which could serve as an intense source of photo- neutrons, up to 4 x 10 12 n/s for use in nuclear medicine, short-lived isotope production, or other applications. In addition, it could produce gamma dose rates up to 130 kR/min-m with a heavy metal bremsstrahlung target. The results and specifications of this were submitted to IPAC16 (Reference [12]) the paper is included in Addendum B. Because this version was beyond the scope of the Phase I project, there is no additional description in the Final Report.

43 PARTICLE ACCELERATORS↗

A Novel, Low-Cost, Portable Device for Counterfeit and Noncompliant Refrigerant Detection

The increasing prevalence of counterfeit refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVACR) systems, including compromised equipment performance, safety hazards, and environmental non-compliance. This report details the development of a novel, cost-effective, and portable detection device designed to accurately identify counterfeit refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing users with clear visual indicators for refrigerant authenticity.Laboratory validation demonstrated the device’s high accuracy (exceeding 95%) in detecting unauthorized refrigerant blends. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks such as the American Innovation and Manufacturing (AIM) Act, enhances safety in HVACR operations, and mitigates the risks associated with counterfeit refrigerants. Future developments will focus on expanding refrigerant detection capabilities, integrating machine learning for enhanced accuracy, implementing cost-reduction strategies to improve accessibility and market adoption, and optimizing system packaging for enhanced field portability.

99 GENERAL AND MISCELLANEOUS↗

Portable Waveguide-Based Optical Biosensor

Rapid, on-site diagnostics allow for timely intervention and response for warfighter support, environmental monitoring, and global health needs. Portable optical biosensors are being widely pursued as a means of achieving fieldable biosensing due to the potential speed and accuracy of optical detection. We recently developed the portable engineered analytic sensor with automated sampling (PEGASUS) with the goal of developing a fieldable, generalizable biosensing platform. Here, we detail the development of PEGASUS’s sensing hardware and use a test-bed system of identical sensing hardware and software to demonstrate detection of a fluorescent conjugate at 1 nM through biotin-streptavidin chemistry.

47 OTHER INSTRUMENTATION↗

Improved Spacecraft Tracking and Navigation Using a Portable Radio Science Receiver

The Portable Radio Science Receiver (PRSR) is a suitcase-sized open-loop digital receiver designed to be small and easy to transport so that it can be deployed quickly and easily anywhere in the world. The PRSR digitizes, downconverts, and filters using custom hardware, firmware, and software. Up to 16 channels can be independently configured and recorded with a total data rate of up to 256 Mbps. The design and implementation of the system's hardware, firmware, and software is described. To minimize costs and time to deployment, our design leveraged elements of the hardware, firmware, and software designs from the existing full-sized operational (non-portable) Radio Science Receivers (RSR) and Wideband VLBI Science Receivers (WVSR), which have successfully supported flagship NASA deep space missions at all Deep Space Network (DSN) sites. We discuss a demonstration of the PRSR using VLBI, with one part per billion angular resolution: 1 nano-radian / 200 ?as synthesized beam. This is the highest resolution astronomical instrument ever operated solely from the Southern Hemisphere. Preliminary results from two sites are presented, including the European Space Agency (ESA) sites at Cebreros, Spain and Malargue, Argentina. Malargue's South American location is of special interest because it greatly improves the geometric coverage for spacecraft navigation in the Southern Hemisphere and will for the first time provide coverage to the 1/4 of the range of declination that has been excluded from reference frame work at Ka-band.

Delta Differential One-Way (DOR)↗

A Portable 16-channel Magnetic Sensor for Human Magnetocardiographic Experiments

Here, we constructed a portable, low-cost 16-channel magnetic sensor for magnetocardiography (MCG) applications. The sensor is based on a high-sensitivity optically pumped magnetometer (OPM) with a novel configuration of nearly parallel pump and probe laser beams. The OPM-based 16-channel magnetic sensing is realized in a single module by using a fairly large rubidium vapor cell, broad pump/probe laser beams, and a 16-channel photodiode array, leading projected 10-fold reduction of the cost of sensors. The portability of the sensor is achieved by coupling the pump and probe lasers to OPM optics through multi-mode optical fibers. The 16-channel magnetic sensor is surrounded by a non-magnetic enclosure for safe operation. For MCG experiments with the sensor, its main components except lasers are located inside a magnetically shielded room (MSR), which reduces the ambient magnetic noise. The location of lasers and supporting electronics outside the MSR improves the sensitivity of the sensor. We report that the 16-channel magnetic sensor has a magnetic field sensitivity sufficient to directly detect the human cardiac magnetic signals.

16-channel magnetic sensing↗

Tailored Micromagnet Sorting Gate for Simultaneous Multiple Cell Screening in Portable Magnetophoretic Cell‐On‐Chip Platforms

Abstract Conventional magnetophoresis techniques for manipulating biocarriers and cells predominantly rely on large‐scale electromagnetic systems, which is a major obstacle to the development of portable and miniaturized cell‐on‐chip platforms. Herein, a novel magnetic engineering approach by tailoring a nanoscale notch on a disk micromagnet using two‐step optical and thermal lithography is developed. Versatile manipulations are demonstrated, such as separation and trapping, of carriers and cells by mediating changes in the magnetic domain structure and discontinuous movement of magnetic energy wells around the circumferential edge of the micromagnet caused by a locally fabricated nano‐notch in a low magnetic field system. The motion of the magnetic energy well is regulated by the configuration of the nanoscale notch and the strength and frequency of the magnetic field, accompanying the jump motion of the carriers. The proposed concepts demonstrate that multiple carriers and cells can be manipulated and sorted using optimized nanoscale multi‐notch gates for a portable magnetophoretic system. This highlights the potential for developing cost‐effective point‐of‐care testing and lab‐on‐chip systems for various single‐cell‐level diagnoses and analyses.

36 MATERIALS SCIENCE↗

Using Compiler Directives for Performance Portability in Scientific Computing: Kernels from Molecular Simulation

Achieving performance portability for high-performance computing (HPC) applications in scientific fields has become an increasingly important initiative due to large differences in emerging supercomputer architectures. Here we test some key kernels from molecular dynamics (MD) to determine whether the use of the OpenACC directive-based programming model when applied to these kernels can result in performance within an acceptable range for these types of programs in the HPC setting. We find that for easily parallelizable kernels, performance on the GPU remains within this range. On the CPU, OpenACC-parallelized pairwise distance kernels would not meet the performance standards required, when using AMD Opteron “Interlagos” processors, but with IBM Power 9 processors, performance remains within an acceptable range for small batch sizes. These kernels provide a test for achieving performance portability with compiler directives for problems with memory-intensive components as are often found in scientific applications.

Sedova, Ada↗

Exploring the Limits of Overhauser Dynamic Nuclear Polarization (O-DNP) for Portable Magnetic Resonance Detection of Low γ Nuclei

Nuclear magnetic resonance (NMR) spectroscopy in portable, permanent magnet-based spectrometers is primarily limited to nuclei with higher gyromagnetic ratio, γ, such as 1 H, 19 F, and 31 P due to the limited field strength achievable in these systems. Overhauser effect dynamic nuclear polarization (O-DNP), which transfers polarization from an unpaired electron to a nucleus by saturating an electron paramagnetic resonance transition with an oscillating radio frequency magnetic field, B 1e , can increase the polarization of low γ nuclei by hundreds or even thousands, enabling detection in a portable system. We have investigated the potential for O-DNP to enhance signals using (4-amino-2,2,6,6-tetramethylpiperidin-1-yl)oxyl (TEMPO hereafter) as a source of unpaired electrons in a homebuilt ultra-low field (ULF) O-DNP-NMR spectrometer. We have found, in general, that larger concentrations of TEMPO are required for effective O-DNP with low γ nuclei, which has a number of important effects. Spin exchange effects cause the EPR lines to overlap and ultimately merge at high concentrations of TEMPO, fundamentally increasing the maximum possible enhancement, while the electron–electron dipolar interaction reduces both longitudinal and transverse relaxation times for the electrons, dramatically increasing the required B 1e strength. The relationship between TEMPO concentration, B 1e magnitude and O-DNP enhancement is quantified, and strategies for achieving these fields are discussed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Personal thermal management using portable thermoelectrics for potential building energy saving

Heating and cooling of buildings consume approximately 15% of all energy used in the United States. Such a large energy demand is primarily due to heating and cooling of the entire building space to temperature setpoints usually between 21.1 degrees C (70 degrees F) and 23.9 degrees C (75 degrees F). However, even with such a narrow range of temperature setpoints, more than 20% of the occupants do not feel thermally comfortable due to individual differences (e.g. age, gender, clothing, or physiology). The personal thermal management techniques, which create a local thermal envelope around a human body instead of heating or cooling the entire building space, have the potential to greatly reduce the building energy consumption and to enhance thermal comfort of individuals. In this study, a portable thermoelectric energy conversion unit (TECU) that converts electricity into cooling and heating energy is developed. The TECU supplies cool air (in the cooling mode) or warm air (in the heating mode) to regulate the thermal comfort of a human body. The cool or warm air is supplied through a tree-like rubber tube network that is knitted into a thermoregulatory undergarment. To achieve a cooling/heating target that provides satisfactory thermal comfort, the required cooling/heating power supply from the TECU is determined first while a theoretical model is then developed to guide the design of the TECU. To minimize the TECU weight and make it suitable for portable applications, relationships between weight and thermal resistances of commercial off-the-shelf heat sinks are established first, and a method to find the minimal weight of heat sinks for the TECU is then developed. This methodology is also applicable for other applications where heat sink weight needs to be minimized. The thermal manikin tests demonstrate that 24.6 W of personal cooling power and 18.5 W of personal heating power are achieved by using the TECU.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ExaCA v2.0: A versatile, scalable, and performance portable cellular automata application for additive manufacturing solidification

The previously established ExaCA software for performance portable alloy grain structure simulation has been updated to better represent the solidification behavior during complex alloy processing conditions, such as those encountered during metal additive manufacturing (AM), and for improved performance and scalability. Here, an extension to the time–temperature history input data format and the core ExaCA algorithm to include an arbitrary number of melting and solidification events yielded improved prediction of texture for various melt pool geometries, expanding the range of AM-relevant conditions that can be accurately simulated. Improved heat transport process simulation coupling, including the creation of large raster datasets from single track time–temperature history data and in-memory coupling with the new, performance portable finite difference code Finch, were also demonstrated in example studies on the effect of multilayer AM microstructure predictions on hatch spacing and cell size, respectively. Additional new features are detailed and demonstrated, including the ability to perform simulations using various interfacial response function forms, execute simulations on state-of-the-art hardware, improved usability through post-processing versatility, and improved strong and weak scaling performance. The performance, physics, and versatility improvements demonstrated here will further enable large-scale studies on AM process–microstructure relationships that were not previously possible. Furthermore, the usability improvements and ability to run coupled AM process–microstructure simulations using the Finch-ExaCA workflow will facilitate broader use of this open-source software by the computational materials community.

36 MATERIALS SCIENCE↗

An immersed interface method for microstructure-scale electrochemical battery models: numerical formulation and performance portable implementation

We present the numerical formulation, verification, and performance portable implementation of an immersed interface method for microstructure scale electrochemical modeling of batteries. The innovation in this approach is the resolution of chemical species and electrostatic potential discontinuities at active interfaces without the use of interface conforming unstructured grids. A unified formulation on Cartesian grids for all domains (electrodes and electrolyte) is used with interfacial flux conditions applied using volume fraction or “color” function gradients. We have developed one dimensional and two dimensional test cases with analytic solutions for electrochemical modeling using which we verified the consistency and accuracy of our scheme. Our solver is also validated against solutions from a macroscale model and an unstructured multi-subdomain solver for a full lithium ion cell. We then demonstrated the utility of our solver on an image-based complex battery electrode microstructure at high charging rate. Our technique also exhibits good scalability on distributed memory architectures using central processing units (CPU), with problem sizes up to 1.8 billion degrees of freedom and with 5400 ranks. Initial performance studies of our open-source performance portable solver showed about 70 times speed up using a graphics processing unit (GPU) compared to single compute core for a problem with 4 million cells.

25 ENERGY STORAGE↗

Framework for the assessment of PEMS (Portable Emissions Measurement Systems) uncertainty

Highlights: • Portable Emissions Measurement Systems (PEMS) are used to measure Real-Driving Emissions (RDE) of vehicles. • The uncertainty of PEMS was evaluated based on experimental data and technical requirements prescribed in the European regulation. • The 2017 uncertainty estimation was 43%. European regulation 2016/427 (the first package of the so-called Real-Driving Emissions (RDE) regulation) introduced on-road testing with Portable Emissions Measurement Systems (PEMS) to complement the chassis dynamometer laboratory (Type I) test for the type approval of light-duty vehicles in the European Union since September 2017. The Not-To-Exceed (NTE) limit for a pollutant is the Type I test limit multiplied by a conformity factor that includes a margin for the additional measurement uncertainty of PEMS relative to standard laboratory equipment. The variability of measured results related to RDE trip design, vehicle operating conditions, and data evaluation remain outside of the uncertainty margin. The margins have to be reviewed annually (recital 10 of regulation 2016/646). This paper lays out the framework used for the first review of the NO{sub x} margin, which is also applicable to future margin reviews. Based on experimental data received from the stakeholders of the RDE technical working group in 2017, two NO{sub x} margin scenarios of 0.24–0.43 were calculated, accounting for different assumptions of possible zero drift behaviour of the PEMS during the tests. The reduced uncertainty margin compared to the one foreseen for 2020 (0.5) reflects the technical improvement of PEMS over the past few years.

54 ENVIRONMENTAL SCIENCES↗

Development of a CPU/GPU portable software library for Lagrangian–Eulerian simulations of liquid sprays

The Lagrangian–Eulerian method is widely used for simulations of fuel sprays in turbulent combustion because of the advantage of treating the spray droplets as discrete points. One challenge of the Lagrangian–Eulerian method is the intense computational requirement when tracking the large number of Lagrangian particles needed for high fidelity. We have developed a performance-portable library, Grit, to track the Lagrangian particles in parallel on central processing unit (CPU) and graphics processing unit (GPU) accelerated high performance computing (HPC) architectures. Grit is a C++ library which employs Message Passing Interface (MPI) for distributed memory parallelism and Kokkos programming model for on-node shared memory parallelism with performance portability across different architectures of GPUs and multi-core/manycore CPUs. The parallel algorithms, key parallel kernels, and their performances on the pre-exascale supercomputer, Summit, are presented. Grit is coupled with a direct numerical simulation (DNS) solver, S3D, for multiphase simulations. A conservative formulation has been developed and implemented in Grit for phase coupling with thermodynamic consistency. The formulation separates the conservation of mass, momentum and energy from the physical models to prevent accidental violation of conservation laws due to inconsistent models. The formulation also enforces consistent definitions of enthalpies of the fuel for both phases and the latent heat of evaporation. Finally, simulations of turbulent particle-laden flow and the evaporation of dilute turbulent spray jet are performed to verify the software implementation, and to demonstrate the scalability of Grit for large-scale multiphase simulations.

97 MATHEMATICS AND COMPUTING↗

Non-destructive measurement and real-time monitoring of apple hardness during ultrasonic contact drying via portable NIR spectroscopy and machine learning

Portable near-infrared spectrometer in the spectral range of 900–1700 nm was evaluated for the first time to assess and monitor apple hardness in real-time during ultrasonic drying. Calibration models were developed using PLS and ANN, and their performances were evaluated by internal leave-one-out cross-validation and an external dataset. Several pre-treatments including standard normal variate (SNV), multiplicative scatter correction (MSC), Savitzky–Golay first and second derivatives were employed to examine the effects of spectral variations in hardness prediction. Seven important wavelengths were selected using weighted regression coefficients to develop a simple MLR model to facilitate the model interpretation and circumvent noise. The models using PLS, MLR, and ANN with selected wavelengths predicted the apple hardness with R 2 p of 0.91, 0.91, 0.95, and RMSEP of 14.78, 14.85, and 12.46 N, respectively. Finally, the results indicate that portable NIR spectrometers are quite promising for real-time monitoring of apple hardness during ultrasonic drying.

47 OTHER INSTRUMENTATION↗