Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Muon tracking in a LiquidO opaque scintillator detector

LiquidO is an innovative radiation detector concept. The core idea is to exploit stochastic light confinement in a highly scattering medium to self-segment the detector volume. In this paper, we demonstrate event-by-event muon tracking in a LiquidO opaque scintillator detector prototype. The detector consists of a 30 mm cubic scintillator volume instrumented with 64 wavelength-shifting fibres arranged in an 8 × 8 grid with a 3.2 mm pitch and read out by silicon photomultipliers. A wax-based opaque scintillator with a scattering length of approximately 0.5 mm is used. The tracking performance of this LiquidO detector is characterised with cosmic-ray muons and the position resolution is demonstrated to be 450 μm per row of fibres. These results highlight the potential of LiquidO opaque scintillator detectors to achieve fine spatial resolution, enabling precise particle tracking and imaging.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-rate heavy-ion tracking using MWPCs and PPACs with an Anti-Discharge Unit

This work reports on the development of two robust, heavy-ion beam tracking concepts operating at low pressure (< 15 Torr) for high rate applications (> 200 kHz). The first concept consists of a Multi-Wire Proportional Counter (MWPC) with a central anode consisting of 12 μm Au-plated Tungsten wires spaced 1 mm from each other. The anode grid is sandwiched between two segmented cathodes aligned orthogonally in the two dimensions for (x,y) particle localization. The second detector is a Parallel-Plate Avalanche Counter (PPAC) that uses the same readout geometry as the MWPC, but replaces the wire anode with a 150 nm silver layer deposited on both sides of a thin (< 1 mg/cm 2 ) polypropylene foil. Additionally, the bias circuitry for the PPAC anode central foil is equipped with an Anti-Discharge Unit (ADU) to prevent transitions from proportional operation to streamer formation, thereby avoiding damaging discharges. The localization capability of both detectors was tested with a low-rate alpha-particle source (241-Am). A position resolution of < 1 mm (FWHM) was achieved under stable, high-gas-gain (> 1000) operating conditions. Their performance in terms of detection efficiency as a function of the isotope charge (Z) was determined by irradiating the detectors with a cocktail beam (Z ≤ 15) with energy of ∼ 100 MeV/u. Full detection efficiency is maintained for all available fragments under optimal operational conditions (i.e., voltage bias). Full detection efficiency was achieved at rates above 200 kHz by irradiating the detectors with a 1 cm diameter 238 U beam at an energy of 143 MeV/u.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status and Performance of New Silicon Stripixel Detector for the PHENIX Experiment at RHIC: Beta Source, Cosmic-rays and Proton Beam at 120 GeV

We are constructing a Silicon Vertex Tracker detector (VTX) for the PHENIX experiment at RHIC. Our main motivation is to enable measurements of heavy flavor production (charm and beauty) in p+p, p+d and A+A collisions. Such data will illuminate the properties of the matter created in high-energy heavy-ion collisions. The measurements also will reveal the distribution of gluons in protons from p+p collisions. The VTX detector consists of four layers of barrel detectors and covers |{eta}|<1.2, and almost a 2{pi} in azimuth. The inner two silicon barrels consist of silicon pixel sensors; their technology accords with that of the ALICE1LHCB sensor-readout hybrid. The outer two barrels are silicon stripixel detectors with a new 'spiral' design, and a single-sided sensor with 2-dimensional (X, U) readout. In this paper, we describe the silicon stripixel detector and discuss its performance, including its response to electrons from a beta source ({sup 90}Sr), muons from cosmic-rays, and a 120 GeV proton beam. The results from the proton beam demonstrate that the principle of two-dimensional position sensitivity based on charge sharing works; the signal-to-noise value is 10.4, the position resolution is 33.6 {micro}m for X-stripixel (35.2 {micro}m for U-stripixel), and the tracking efficiencies in the X- and U-stripixels are, over 98.9 {+-} 0.2%. The stripixel detector within the VTX project is in the pre-production phase.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nuclear recoil spectroscopy of levitated particles

Here, we propose a method for the detection and characterization of nuclear decay processes. Specifically, we describe how nuclear decay recoil can be observed within small particles levitated in an optical trap with high positional resolution. Precise measurements of the magnitude of each recoil as well as their rate of occurrence can provide accurate information about the isotopic composition of a radioactive sample. We expect that this technique for nuclear material characterization will be especially useful in the area of nuclear forensic analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Intruder dominance in the ${0_2^+}$ state of 32 Mg studied with a novel technique for in-flight decays

The development of advanced $γ$-ray tracking arrays allows for a sensitive new technique to investigate elusive states of exotic nuclei with fast rare-isotope beams. By taking advantage of the excellent energy and position resolution of the Gamma-Ray Energy Tracking In-beam Nuclear Array in this study, we developed a novel technique to identify in-flight isomeric decays of the 0$^+_2$ state in 32 Mg populated in a two-proton removal reaction. We confirm the 0$^+_2$ → 2$^+_1$ $γ$-ray transition of 32 Mg and constrain the 0$^+_2$ decay lifetime, suggesting a large collectivity. The small partial cross section populating the 0$^+_2$ state in this reaction provides experimental evidence for the reduced occupancy of the normal configuration of the 0$^+_2$ state, indicating the intruder dominance of this state.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Benefits of MeV-scale reconstruction capabilities in large liquid argon time projection chambers

Using truth-level Monte Carlo simulations of particle interactions in a large volume of liquid argon, we demonstrate physics capabilities enabled by reconstruction of topologically compact and isolated low-energy features, or “blips,” in large liquid argon time projection chamber (LArTPC) events. These features are mostly produced by electron products of photon interactions depositing ionization energy. The blip identification capability of the LArTPC is enabled by its unique combination of size, position resolution precision, and low energy thresholds. Here, we show that consideration of reconstructed blips in LArTPC physics analyses can result in substantial improvements in calorimetry for neutrino and new physics interactions and for final-state particles ranging in energy from the MeV to the GeV scale. Blip activity analysis is also shown to enable discrimination between interaction channels and final-state particle types. In addition to demonstrating these gains in calorimetry and discrimination, some limitations of blip reconstruction capabilities and physics outcomes are also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration, event reconstruction, data analysis, and limit calculation for the LUX dark matter experiment

Here, the LUX experiment has performed searches for dark matter particles scattering elastically on xenon nuclei, leading to stringent upper limits on the nuclear scattering cross sections for dark matter. Here, for results derived from ${1.4}\times 10^{4}\;\mathrm{kg\,days}$ of target exposure in 2013, details of the calibration, event-reconstruction, modeling, and statistical tests that underlie the results are presented. Detector performance is characterized, including measured efficiencies, stability of response, position resolution, and discrimination between electron- and nuclear-recoil populations. Models are developed for the drift field, optical properties, background populations, the electron- and nuclear-recoil responses, and the absolute rate of low-energy background events. Innovations in the analysis include in situ measurement of the photomultipliers' response to xenon scintillation photons, verification of fiducial mass with a low-energy internal calibration source, and new empirical models for low-energy signal yield based on large-sample, in situ calibrations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Research and Development of Scintillation fiber Trackers

We are developing the scintillation fiber trackers. This detector is consist of 0.5 mm diameter scintillation fibers and PPDs. This detector has the doughnut shape with outer diameter of 50 cm and inner diameter of 10 cm and thickness of 2 mm. The position resolution is 70 μm. There are no ineffective area. And the cost is several million yen. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results From a Prototype Combination TPC Cherenkov Detector With GEM Readout

A combined time projection chamber-Cherenkov (TPCC) prototype detector has been developed as part of the detector research and development program for a future electron-ion collider (E!C). The prototype was tested at the Fermilab test beam facility (FTBF) to provide a proof of the principle to demonstrate the ability to measure particle tracks and provide particle identification (P!D) information within a common detector volume. The time projection chamber (TPC) portion consists of a 10 × 10 × 10 cm 3 field cage, which delivers charge from tracks to a quadruple gas electron multiplier (GEM) with zigzag-shaped charge collection anodes. The Cherenkov portion consists of a photosensitive quadruple GEM detector with a Cs! photocathode. As tracks pass through the drift volume of the TPC, the generated Cherenkov light is able to escape through sparsely arranged wires making up one side of the field cage, facing the Cs! photocathode. The Cherenkov detector is thus operated in a windowless, proximity focused configuration for high efficiency. Pure CF 4 is used as the working gas for both detector components, mainly due to its transparency into the deep UV, as well as its high N0. Results from the beam test, including the position resolution as well as the particle id capabilities of the detector, are discussed in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-207A-03: Development of Proton CT Imaging System Using Thick Scintillator and CCD Camera

Purpose: In the treatment planning of proton therapy, Water Equivalent Length (WEL), which is the parameter for the calculation of dose and the range of proton, is derived by X-ray CT (xCT) image and xCT-WEL conversion. However, about a few percent error in the accuracy of proton range calculation through this conversion has been reported. The purpose of this study is to construct a proton CT (pCT) imaging system for an evaluation of the error. Methods: The pCT imaging system was constructed with a thick scintillator and a cooled CCD camera, which acquires the two-dimensional image of integrated value of the scintillation light toward the beam direction. The pCT image is reconstructed by FBP method using a correction between the light intensity and residual range of proton beam. An experiment for the demonstration of this system was performed with 70-MeV proton beam provided by NIRS cyclotron. The pCT image of several objects reconstructed from the experimental data was evaluated quantitatively. Results: Three-dimensional pCT images of several objects were reconstructed experimentally. A finestructure of approximately 1 mm was clearly observed. The position resolution of pCT image was almost the same as that of xCT image. And the error of proton CT pixel value was up to 4%. The deterioration of image quality was caused mainly by the effect of multiple Coulomb scattering. Conclusion: We designed and constructed the pCT imaging system using a thick scintillator and a CCD camera. And the system was evaluated with the experiment by use of 70-MeV proton beam. Three-dimensional pCT images of several objects were acquired by the system. This work was supported by JST SENTAN Grant Number 13A1101 and JSPS KAKENHI Grant Number 15H04912.

60 APPLIED LIFE SCIENCES↗

Accessing tens-to-hundreds femtoseconds nuclear state lifetimes with low-energy binary heavy-ion reactions

A novel Monte Carlo technique has been developed to determine lifetimes of excited states in the tens-to-hundreds femtoseconds range in products of low-energy heavy-ion binary reactions, with complex velocity distributions. The method is based on a detailed study of Doppler-broadened γ-ray lineshapes. Its relevance is demonstrated in connection with the 18 O(7.0MeV/u)+ 181 Ta experiment, performed at GANIL with the AGATA+VAMOS+PARIS setup, to study neutron-rich O, C, N, ... nuclei. Excited states in 17 O and 19 O, with known lifetimes, are used to validate the method over the ~20-400fs lifetime-sensitivity range. Emphasis is given to the unprecedented position resolution provided by γ-tracking arrays, which turns out to be essential for reaching the required accuracy in Doppler-shift correction. The technique is anticipated to be an important tool for lifetime investigations in exotic neutron-rich nuclei, produced with intense ISOL-type beams.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detection prospects for the second-order weak decays of 124 Xe in multi-tonne xenon time projection chambers

We investigate the detection prospects for two-neutrino and neutrinoless second-order weak decays of 124 Xe – double-electron capture (0/2νECEC), electron capture with positron emission (0/2νECβ + ) and double-positron emission (0/2νβ + β + ) – in multi-tonne xenon time projection chambers. We simulate the decays in a liquid xenon medium and develop a reconstruction algorithm which uses the multi-particle coincidence in these decays to separate signal from background. This is used to compute the expected detection efficiencies as a function of position resolution and energy threshold for planned experiments. In addition, we consider an exhaustive list of possible background sources and find that they are either negligible in rate or can be greatly reduced using our topological reconstruction criteria. In particular, we draw two conclusions: First, with a theoretical half-life of $T^{2νECβ^+}_{1/2}$= (1.7 ± 0.6) ∙10 23 year, the 2νECβ + decay of 124 Xe will likely be detected in upcoming Dark Matter experiments (e.g. XENONnT or LZ), and their major background will be γ-rays from detector construction materials. Second, searches for the 0νECβ + decay mode will likely be background-free, and new parameter space may be within reach. To this end we investigate two different scenarios of existing experimental constraints on the effective neutrino mass. The necessary 500 kg-year exposure of 124 Xe could be achieved by the baseline design of the DARWIN observatory, or by extracting and using the 124 Xe from the tailings of the nEXO experiment. We demonstrate how a combination of 124 Xe results with those from 0νβ - β - searches in 136 Xe could help to identify the neutrinoless decay mechanism.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range

Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The “standard” EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the visible and near infrared (NIR) ranges. The first is due to bremsstrahlung of electrons scattered on neutral atoms (“neutral bremsstrahlung”, NBrS). The second, responsible for electron avalanche scintillation in the NIR at higher electric fields, is due to transitions between excited atomic states. In this work, we have for the first time demonstrated two alternative techniques of the optical readout of two-phase argon detectors, in the visible and NIR range, using a silicon photomultiplier matrix and electroluminescence due to either neutral bremsstrahlung or avalanche scintillation. The amplitude yield and position resolution were measured for these readout techniques, which allowed to assess the detection threshold for electron and nuclear recoils in two-phase argon detectors for dark matter searches. To the best of our knowledge, this is the first practical application of the NBrS effect in detection science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Searches for Sub-GeV Dark Matter with NOvA and LDMX and Performance Studies of the Cosmic-Ray Veto for Mu2e

The constituents of dark matter are still unknown, and the viable possibilities span a very large mass range. Specific scenarios for the origin of dark matter sharpen the focus to within about an MeV to 100 TeV. Most of the stable constituents of known matter have masses in the lower range, and a thermal origin for dark matter works in a simple and predictive manner in this mass range as well. Non-gravitational couplings of dark matter to Standard Model particles would make it possible to produce dark matter at accelerators. Through 120 GeV proton-nucleus collisions, NOvA is effectively a beam dump experiment for producing and detecting dark matter. This thesis presents a search for dark matter – electron scattering in the NOvA near detector from sub-GeV dark matter produced at the target. A future search for sub-GeV dark matter with the Light Dark Matter eXperiment (LDMX) is discussed, along with a study of LDMX's expected sensitivity to visibly decaying dark photons. Additionally, performance studies of the Mu2e cosmic ray veto (CRV) are presented. A calibration procedure for the CRV counters is discussed, along with tests of the efficiency, position resolution, and light yield decline of the CRV counters.

Horoho, Tyler Gregory [Virginia U.] (ORCID:0000000↗

Development of Large-Area Photo-Detectors (Final Scientific/Technical Report)

This proposal requested ADR funds for two years to make measurements and detector proto-types in the context of planning a program in conjunction with Argonne National Laboratory to develop very large-area planar photodetectors. The proposed detectors have integrated transmission-line readout and sampling electronics able to achieve timing and position resolutions in the range of 1-50 psec and 1-10 mm, respectively. The capability for very precise time measurements is inherent in the design, and provides a third coordinate, orthogonal to the two in the plane, for the point of origin of photons or charged particles, allowing tomographic reconstruction in 3-dimensions inside a volume.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Semiconductor detectors with proximity signal readout

Semiconductor-based radiation detectors are routinely used for the detection, imaging, and spectroscopy of x-rays, gamma rays, and charged particles for applications in the areas of nuclear and medical physics, astrophysics, environmental remediation, nuclear nonproliferation, and homeland security. Detectors used for imaging and particle tracking are more complex in that they typically must also measure the location of the radiation interaction in addition to the deposited energy. In such detectors, the position measurement is often achieved by dividing or segmenting the electrodes into many strips or pixels and then reading out the signals from all of the electrode segments. Fine electrode segmentation is problematic for many of the standard semiconductor detector technologies. Clearly there is a need for a semiconductor-based radiation detector technology that can achieve fine position resolution while maintaining the excellent energy resolution intrinsic to semiconductor detectors, can be fabricated through simple processes, does not require complex electrical interconnections to the detector, and can reduce the number of required channels of readout electronics. Proximity electrode signal readout (PESR), in which the electrodes are not in physical contact with the detector surface, satisfies this need.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Working Group Report: Sensors

Sensors play a key role in detecting both charged particles and photons for all three frontiers in Particle Physics. The signals from an individual sensor that can be used include ionization deposited, phonons created, or light emitted from excitations of the material. The individual sensors are then typically arrayed for detection of individual particles or groups of particles. Mounting of new, ever higher performance experiments, often depend on advances in sensors in a range of performance characteristics. These performance metrics can include position resolution for passing particles, time resolution on particles impacting the sensor, and overall rate capabilities. In addition the feasible detector area and cost frequently provides a limit to what can be built and therefore is often another area where improvements are important. Finally, radiation tolerance is becoming a requirement in a broad array of devices. We present a status report on a broad category of sensors, including challenges for the future and work in progress to solve those challenges.

HEP↗

Application of pixel-cell detector technology for Advanced Neutron Beam Monitors

Application of Pixel-Cell Detector Technology for Advanced Neutron Beam Monitors Specifications of currently available neutron beam detectors limit their usefulness at intense neutron beams of large-scale national user facilities used for the advanced study of materials. A large number of neutron-scattering experiments require beam monitors to operate in an intense neutron beam flux of >10E+7 neutrons per second per square centimeter. For instance, a 4 cm x 4 cm intense beam flux of 6.25 x 10E+7 n/s/cm2 at the Spallation Neutron Source will put a flux of 1.00 x 10E+9 n/s at the beam monitor. Currently available beam monitors with a typical efficiency of 1 x 10E-4 will need to be replaced in less than two years of operation due to wire and gas degradation issues. There is also a need at some instruments for beam position information that are beyond the capabilities of currently available He-3 and BF3 neutron beam monitors. ORDELA, Inc.’s research under USDOE SBIR Grant (DE-FG02-07ER84844) studied the feasibility of using pixel-cell technology for developing a new generation of stable, long-life neutron beam monitors. The research effort has led to the development and commercialization of advanced neutron beam detectors that will directly benefit the Spallation Neutron Source and other intense neutron sources such as the High Flux Isotope Reactor. A prototypical Pixel-Cell Neutron Beam Monitor was designed and constructed during this research effort. This prototype beam monitor was exposed to an intense neutron beam at the HFIR SNS HB-2 test beam site. Initial measurements on efficiency, uniformity across the detector, and position resolution yielded excellent results. The development and test results have provided the required data to initiate the fabrication and commercialization of this next generation of neutron-detector systems. ORDELA, Inc. has (1) identified low-cost design and fabrication strategies, (2) developed and built pixel-cell detectors and instrumented a 64-pixel-cell detector to specifications for the Cold-Neutron Chopper Spectrometer and POWGEN instruments, (3) investigated the general characteristics of this technology, (4) studied pixel-cell configurations and arrived at an optimized modular design, and (5) evaluated fabrication costs of mass production for these configurations. The resulting technology will enable a complete line of pixel-cell-based neutron detectors to be commercially under available. ORDELA, Inc has a good track history of application of innovative technology into the marketplace. Our commercialization record reflects this. For additional information, please contact Daniel Kopp at ORDELA, Inc. at +1 (865) 483-8675 or check our website at www.ordela.com.

36 MATERIALS SCIENCE↗