Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power offset”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Fine Calcium Carbonate Production by CO 2 Mineralization of Industrial Waste Brines

Calcium carbonate production via CO 2 mineralization offers an attractive route for carbon capture and utilization. The process sequesters CO 2 in a stable form of fine precipitated calcium carbonate, a high-value product with unit price in the range of $230-$280/t and a global market projected to reach 99 M tons in 2020. However, two critical barriers hinders CO 2 mineralization—(i) the need for costly processes such as electrolysis or addition of alkali hydroxides to maintain alkalinity during mineralization, and (ii) the geographic location mismatch between Ca-rich solutions (or brines) CO 2 generation sources (e.g. power plants) which often renders efficient integration of feedstocks impractical. To simultaneously address these challenges, a new process is developed to integrate CO 2 mineralization-based carbonate production into the zero liquid discharge water (ZLD) treatment systems at coal-fired power plants. In this process, Ca-rich streams, such as produced water from oil and gas extraction or carbon storage operations, serves as the Ca-source. An H + /Na + ion-exchange cycle is designed to provision alkalinity during mineralization and regenerate the ion-exchange reagent in solutions with high salinity. Ca-depleted streams are then treated within a centralized ZLD system. The process beneficially utilizes reject streams that are available at substantial quantities in the vicinity of coal power plants within several U.S regions. In addition, the process utilizes post-desulfurization flue gas from coal-fired power plants as is. The CO 2 conversion reactions are performed in alkaline streams at ambient pressure, thereby minimizing the energy burden. By beneficiation of industrial waste streams with low energy input, this process offers significant technical advantages in energy and CO 2 footprint over the current paradigm of precipitated calcium carbonate production. Overall, the new process provides a unique route to integrate CO 2 emissions control and wastewater treatment for coal power plants, while producing high-value product to offset the economic burden associated with waste management.

Simonetti, Dante↗

Hybrid Solid Oxide Fuel Cell/Gas Turbine System Design for High Altitude Long Endurance Aerospace Missions

A system level analysis, inclusive of mass, is carried out for a cryogenic hydrogen fueled hybrid solid oxide fuel cell and bottoming gas turbine (SOFC/GT) power system. The system is designed to provide primary or secondary electrical power for an unmanned aerial vehicle (UAV) over a high altitude, long endurance mission. The net power level and altitude are parametrically varied to examine their effect on total system mass. Some of the more important technology parameters, including turbomachinery efficiencies and the SOFC area specific resistance, are also studied for their effect on total system mass. Finally, two different solid oxide cell designs are compared to show the importance of the individual solid oxide cell design on the overall system. We show that for long mission durations of 10 days or more, the fuel mass savings resulting from the high efficiency of a SOFC/GT system more than offset the larger powerplant mass resulting from the low specific power of the SOFC/GT system. These missions therefore favor high efficiency, low power density systems, characteristics typical of fuel cell systems in general.

Himansu, Ananda↗

Demonstration of a Switched Wideband GaN High-Power Amplifier for Future Space Missions

In this paper, we present the architecture of a Ka-band switched, wideband, high efficiency gallium nitride based high-power amplifier. The architecture is validated by characterizing the driver and power amplifier chain. The measured results include Pout, Gain, PAE, RMS EVM for QPSK, Offset-QPSK, 8PSK, 16APSK, and 16QAM constellations, 3rd order IMD products, noise figure, and added phase noise. The wide bandwidth and high output power of the amplifier will enable future user terminals to interoperate between multiple service provider’s space networks.

Rainee N. Simons↗

Demonstration of a Switched Wideband GaN High-Power Amplifier for Future Space Missions

In this paper, we present the architecture of a Ka-band switched, wideband, high efficiency gallium nitride based high-power amplifier. The architecture is validated by characterizing the driver and power amplifier chain. The measured results include Pout, Gain, PAE, RMS EVM for QPSK, Offset-QPSK, 8PSK, 16APSK, and 16QAM constellations, 3rd order IMD products, noise figure, and added phase noise. The wide bandwidth and high output power of the amplifier will enable future user terminals to interoperate between multiple service provider’s space networks.

High power amplifier↗

Observations of Energetic High Magnetic Field Pulsars with the Fermi Large Area Telescope

We report the detection of gamma-ray pulsations from the high-magnetic-field rotation-powered pulsar PSR J1119.6127 using data from the Fermi Large Area Telescope. The gamma-ray light curve of PSR J1119.6127 shows a single, wide peak offset from the radio peak by 0.43 +/- 0.02 in phase. Spectral analysis suggests a power law of index 1.0 +/- 0.3(+0.4 -0.2) with an energy cut-off at 0.8 +/- 0.2(+2.0 -0.5) GeV. The first uncertainty is statistical and the second is systematic. We discuss the emission models of PSR J1119.6127 and demonstrate that despite the object's high surface magnetic field--near that of magnetars -- the field strength and structure in the gamma-ray emitting zone are apparently similar to those of typical young pulsars. Additionally, we present upper limits on the gamma-ray pulsed emission for the magnetically active PSR J1846.0258 in the supernova remnant Kesteven 75 and two other energetic high-Beta pulsars, PSRs J1718.3718 and J1734.3333. We explore possible explanations for the non-detection of these three objects, including peculiarities in their emission geometry.

Parent, D.↗

THE LIFETIME AND POWERS OF FR IIs IN GALAXY CLUSTERS

We have identified and studied a sample of 151 FR IIs found in brightest cluster galaxies (BCGs) in the MaxBCG cluster catalog with data from FIRST and NVSS. We have compared the radio luminosities and projected lengths of these FR IIs to the projected length distribution of a range of mock catalogs generated by an FR II model and estimate the FR II lifetime to be 1.9 Multiplication-Sign 10{sup 8} yr. The uncertainty in the lifetime calculation is a factor of two, primarily due to uncertainties in the intracluster medium (ICM) density and the FR II axial ratio. We furthermore measure the jet power distribution of FR IIs in BCGs and find that it is well described by a log-normal distribution with a median power of 1.1 Multiplication-Sign 10{sup 37} W and a coefficient of variation of 2.2. These jet powers are nearly linearly related to the observed luminosities, and this relation is steeper than many other estimates, although it is dependent on the jet model. We investigate correlations between FR II and cluster properties and find that galaxy luminosity is correlated with jet power. This implies that jet power is also correlated with black hole mass, as the stellar luminosity of a BCG should be a good proxy for its spheroid mass and therefore the black hole mass. Jet power, however, is not correlated with cluster richness, nor is FR II lifetime strongly correlated with any cluster properties. We calculate the enthalpy of the lobes to examine the impact of the FR IIs on the ICM and find that heating due to adiabatic expansion is too small to offset radiative cooling by a factor of at least six. In contrast, the jet power is approximately an order of magnitude larger than required to counteract cooling. We conclude that if feedback from FR IIs offsets cooling of the ICM, then heating must be primarily due to another mechanism associated with FR II expansion.

79 ASTRONOMY AND ASTROPHYSICS↗

Ground-Mounted Solar Array in Healthcare

This case study from Madera Community Hospital describes the installation of a 1,140-kilowatt ground-mounted solar photovoltaic array through a 20-year power purchase agreement (PPA). The array produces 2,183,220 kWh annually and offsets approximately 40% of the hospital’s electricity consumption.

Commercial, healthcare, ground mounted array, sola↗

Systems Analysis of Biomass and Coal Co-firing Power Plants with Deep Carbon Capture Toward Net-zero Emissions

Achieving a net-zero emission economy in the United States requires integrating diverse low-carbon and negative-emission technologies into the existing fossil fuel-dominant power fleet. Potential technologies from the low-carbon portfolio include renewable power, fossil power with carbon capture and storage (CCS), bioenergy with CCS (BECCS), and direct air capture (DAC). Renewable power is a clean energy source but has to pair with costly battery storage to provide dispatchable electricity. Fossil power with CCS offers dispatchable electricity yet still relies on DAC to offset residual emissions, even when deploying deep CCS with more than 90% CO2 capture. Coal-biomass co-firing with CCS, a subset of BECCS, is a reliable energy production technology that can be retrofitted from existing electricity generation units (EGUs). Power plant retrofit maximizes the use of the current U.S. coal power fleet without the need for large-scale deployment of new renewable power, battery storage, or DAC. Retrofitting coal-biomass co-firing with deep CCS in EGUs is a promising option, but not a universal solution. Biomass co-firing at a power plant introduces economic challenges and indirectly poses pressure on land and water resources. Meanwhile, retrofitting deep CCS affects plant efficiency and raises electricity generation costs. Overall, the technical feasibility and economic viability of plant retrofits vary across EGUs, as they are contingent upon the regional availability of biomass, unit-specific characteristics, site-specific fuel supply costs, and adjacent CO2 storage potential. Government incentives like 45Q can improve the retrofit viability, though the impact requires further quantification. A comprehensive analysis at the unit level is essential to address the question regarding the fate of the U.S. coal-fired electricity generation fleet toward the net-zero emission goal. This study conducts a systematic techno-economic-environmental assessment of EGUs to identify the viability of biomass co-firing and deep CCS retrofits in the U.S. coal-fired power fleet. Specifically, it characterizes the techno-economic performance of deep carbon capture, estimates life cycle greenhouse gas (GHG) emissions, and conducts a fleet-level assessment on retrofit viability. The key objectives are (1) to estimate the unit-specific performance and retrofitted cost under various biomass co-firing levels and CO2 capture rates; (2) to determine the possibility of reaching net-zero emission at the fleet level; (3) to quantify the cumulative capacities that are suitable for plant retrofits under current and future biomass supply scenarios; and (4) to improve the understanding of policy impacts on such retrofits to help the power sector’s transition to a net-zero economy. Techno-economic Model of Deep Carbon Capture. This study develops the performance and economic models for Monoethanolamine-based post-combustion CO2 capture at 95–99% capture rates. The process is simulated in Aspen Plus, analyzing the performance of carbon capture technology by varying the plant sizes, solvent lean loading, CO2 concentrations, and flue gas inlet temperature. Based on the key inputs and output parameters of CO2 capture, a reduced-order performance model of deep carbon capture is formulated. In addition, an engineering-economic model integrating the performance metrics is developed to estimate the capital as well as operation and maintenance (O&M) costs. Capital cost estimations follow the framework of the Integrated Environmental Control Model (IECM) and incorporate data regressions from three technical reports by IECM, the National Energy Technology Laboratory (NETL), and the National Renewable Energy Laboratory. The O&M cost estimation utilizes the actual inventory consumption rate and labor requirements. Both performance and cost models are embedded into IECM v13.0-beta, a fossil-fuel power plant modeling tool. Life Cycle Assessment of Power Plants. This study estimates the GHG emissions of power plants through life cycle assessment (LCA). The LCA scope includes fuel supply, combustion-based power generation, and CO2 transport and storage. The fuel-based life cycle module is designed following the framework of the NETL Unit Process Library and CO2U LCA Guidance Toolkit. The module is then incorporated into IECM v13.0-beta. The process-based LCA is applied to estimate the GHG emissions of coal and biomass supply, coal- and coal-biomass co-firing power plant operation, as well as CO2 pipeline transport and geographical sequestration. An uncertainty analysis is conducted to quantify the variability and uncertainty associated with the LCA using the Latin Hypercube Sampling (LHS) method. Fleet-level Assessment. This study evaluates the technical and economic feasibility of selected coal-fired EGUs, examines the role of tax credits in retrofit viability, and assesses the competitiveness of retrofitted units against other low-carbon options. Unit screening identifies EGUs for the study, focusing on new, efficient baseload units with air pollution controls. The power plant databases are then established to organize unit-specific information on performance and operating conditions from the relevant public databases. Biomass for co-firing retrofits is selected based on home and neighboring county availability, ensuring sustained operation with at least a 5% co-firing level. The CO2 storage site is determined by state-level storage potential, with ArcGIS Pro and NETL CO2 Saline Storage Cost Model used to identify the optimal balance between the nearest transport distances and affordable storage costs. The latest IECM v13.0-beta is then employed to configure and evaluate the eligible EGUs with or without the deployment of deep CCS and biomass co-firing. A supply curve is established to illustrate the cumulative installed capacity suitable for retrofits at different cost levels. A sensitivity analysis on tax credits for carbon sequestration is performed. Finally, a unit-level cost comparison is conducted among retrofitted plants, renewable power with battery storage, and abated fossil fuels with DAC. Expected Results. This study evaluates the technical, economic, and environmental metrics of each EGU across an array of CO2 capture rates and biomass co-firing level scenarios. Unit-level comparisons will identify critical factors influencing technical performance. The supply curves with and without tax incentives will provide insights into the impact of tax credits on biomass co-firing and CCS deployment. The cost comparisons with renewables and DAC-retrofit will assess the competitiveness of the retrofitted units. Life cycle emissions from each unit will be assessed to identify the scenarios under which net-zero emissions can be achieved. These analyses are expected to determine the total coal-fired capacity suitable for serving as a low-carbon energy source with or without tax incentives. The study results are novel in identifying optimal unit-specific strategies for producing carbon-neutral power, whether through retrofitting EGUs with deep CCS, biomass co-firing, DAC, or installing renewable power with battery. The findings will provide insight into nationwide efforts to ensure reliable, affordable, and low-carbon electricity. It also will inform investment decisions and policies in the deployment of deep carbon capture and negative emission technologies for a net-zero energy future.

Biomass Co-firing↗

AGN ACTIVITY AND IGM HEATING IN THE FOSSIL CLUSTER RX J1416.4+2315

We study active galactic nucleus (AGN) activity in the fossil galaxy cluster RX J1416.4+2315. Radio observations were carried out using the Giant Metrewave Radio Telescope at two frequencies, 1420 and 610 MHz. A weak radio lobe that extends from the central nucleus is detected in the 610 MHz map. Assuming the radio lobe originated from the central AGN, we show that the energy injection into the intergalactic medium is only sufficient to heat up the central 50 kpc within the cluster core, while the cooling radius is larger (∼130 kpc). In the hardness ratio map, three low energy cavities have been identified. No radio emission is detected for these regions. We evaluated the power required to inflate the cavities and showed that the total energy budget is sufficient to offset the radiative cooling. We showed that the initial conditions would change the results remarkably. Furthermore, the efficiency of the Bondi accretion in powering the AGN has been estimated.

79 ASTRONOMY AND ASTROPHYSICS↗

Lifetime fatigue response due to wake steering on a pair of utility-scale wind turbines

Quantifying the impacts on turbine loads during wind farm control is an important consideration in assessing power production benefits. Wake steering controls aim to improve total wind farm performance by coordinating the control actions of individual turbines, wherein an upstream turbine is intentionally yawed at an offset angle from the measured wind direction. Consequently, this redirects its wake for improved power production and potentially reduces fatigue loads of the downstream turbines. This paper studies the lifetime fatigue loads associated with wake steering by using utility-scale wind turbine experimental data to conduct an analysis on a pair of wind turbines. This study was part of a large field experiment in which a group of five GE 1.5-MW SLE CWE turbines were selected as targets for conducting wake steering research. A standard loads instrumentation package and data acquisition system were installed on two turbines within the cluster to measure turbine fundamental loads. The time-series databases were used to calculate loads statistics as well as short-term and lifetime damage equivalent loads. Fatigue calculations followed the guidance in Annex H of the International Electrotechnical Commission standard 61400-1, Edition 4. Lifetime fatigue calculation results are presented in this analysis; three methods of assessing lifetime fatigue were used to determine percent difference for blade root moments, main shaft moments, main shaft torque, and tower top torque. For all three fatigue treatments, some components’ lifetime fatigue increases for the controlled turbine; however, the downwind turbine experienced a reduction in lifetime fatigue and combined effect for the turbine pair results in a reduction of fatigue when wake steering controls are applied.

17 WIND ENERGY↗

Next Generation of Hall Thrusters for Space Propulsion

During the previous year, grant activity research focused on demonstrating high thrust/power operation of Hall thrusters. Performance of a low power and a high power Hall thruster was experimentally investigated at discharge voltages from 100 to 150 volts. Discharge efficiencies dropped significantly as discharge voltage was decreased over this range. Reductions in discharge efficiency with decreasing discharge voltage were attributed to reductions in ionization efficiency and/or ion acceleration through a potential less that the applied discharge voltage relative to the performance of state-of-art Hall thrusters operating at discharge voltages of 300 Volts and above. The low power Hall thruster exhibited a more pronounced reduction in discharge efficiency with decreasing discharge voltage. This was attributed to increased electron leakage related to the axial distribution of the radial magnetic field. These data demonstrated that the thrust benefit of operating at discharge voltages below 130 Volts was offset by a corresponding decrease in discharge efficiency for a given input power. Additional activities included continued support of on-going Hall thruster propulsion research within the On-Board Propulsion Branch at NASA Glenn Research Center.

Keith, Theo G., Jr.↗

Spectroscopic and electrical calculation of band alignment between atomic layer deposited SiO{sub 2} and β-Ga{sub 2}O{sub 3} (2{sup ¯}01)

The energy band alignment between atomic layer deposited (ALD) SiO{sub 2} and β-Ga{sub 2}O{sub 3} (2{sup ¯}01) is calculated using x-ray photoelectron spectroscopy and electrical measurement of metal-oxide semiconductor capacitor structures. The valence band offset between SiO{sub 2} and Ga{sub 2}O{sub 3} is found to be 0.43 eV. The bandgap of ALD SiO{sub 2} was determined to be 8.6 eV, which gives a large conduction band offset of 3.63 eV between SiO{sub 2} and Ga{sub 2}O{sub 3}. The large conduction band offset makes SiO{sub 2} an attractive gate dielectric for power devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

X-RAY OBSERVATIONS OF THE YOUNG PULSAR J1357-6429 AND ITS PULSAR WIND NEBULA

We observed the young pulsar J1357-6429 with the Chandra and XMM-Newton observatories. The pulsar spectrum fits well a combination of an absorbed power-law model ({Gamma} = 1.7 {+-} 0.6) and a blackbody model (kT = 140{sup +60}{sub -40} eV, R {approx} 2 km at the distance of 2.5 kpc). Strong pulsations with pulsed fraction of 42% {+-} 5%, apparently associated with the thermal component, were detected in 0.3-1.1 keV. Surprisingly, the pulsed fraction at higher energies, 1.1-10 keV, appears to be smaller, 23% {+-} 4%. The small emitting area of the thermal component either corresponds to a hotter fraction of the neutron star surface or indicates inapplicability of the simplistic blackbody description. The X-ray images also reveal a pulsar wind nebula (PWN) with complex, asymmetric morphology comprised of a brighter, compact PWN surrounded by the fainter, much more extended PWN whose spectral slopes are {Gamma} = 1.3 {+-} 0.3 and {Gamma} = 1.7 {+-} 0.2, respectively. The extended PWN with the observed flux of {approx}7.5 Multiplication-Sign 10{sup -13} erg s{sup -1} cm{sup -2} is a factor of 10 more luminous then the compact PWN. The pulsar and its PWN are located close to the center of the extended TeV source HESS J1356-645, which strongly suggests that the very high energy emission is powered by electrons injected by the pulsar long ago. The X-ray to TeV flux ratio, {approx}0.1, is similar to those of other relic PWNe. We found no other viable candidates to power the TeV source. A region of diffuse radio emission, offset from the pulsar toward the center of the TeV source, could be synchrotron emission from the same relic PWN rather than from the supernova remnant.

79 ASTRONOMY AND ASTROPHYSICS↗

Rain-rate estimates for an attenuating radar

An iterative method has been used to produce rain-rate estimates for an attenuating frequency radar. An infinite number of higher-order estimates are shown to converge in the limit to the Hitschfeld-Bordan solution under certain conditions. An error analysis was performed by a model accounting for the randomness of the radar return power, the k-Z, Z-R relations, and offsets in the radar calibration constant. Since the behavior of the estimates strongly depends on system errors, the choice of the best estimate requires a knowledge of the variance and range of offsets in meteorological data and the calibration constant. As the errors increase, the use of the lower orders avoids significant overpredictions. In order to obtain reliable rain-rate predictions in the presence of realistic errors, an antenna pointing angles away from the horizontal at frequencies in the lower end of the X-band may be used. Such antenna configurations insure low attenuation.

Meneghini, R.↗

Ray tracing optical analysis of offset solar collector for space station solar dynamic system

OFFSET, a detailed ray tracing computer code, was developed at NASA Lewis Research Center to model the offset solar collector for the Space Station solar dynamic electric power system. This model traces rays from 50 points on the face of the Sun to 10 points on each of the 456 collector facets. The triangular facets are modeled with spherical, parabolic, or toroidal reflective surface contour and surface slope errors. The rays are then traced through the receiver aperture to the walls of the receiver. Images of the collector and of the Sun within the receiver produced by this code provide insight into the collector receiver interface. Flux distribution on the receiver walls, plotted by this code, is improved by a combination of changes to aperture location and receiver tilt angle. Power loss by spillage at the receiver aperture is computed and is considerably reduced by using toroidal facets.

Jefferies, Kent S.↗

Ray tracing optical analysis of offset solar collector for Space Station solar dynamic system

OFFSET, a detailed ray tracing computer code, was developed at NASA Lewis Research Center to model the offset solar collector for the Space Station solar dynamic electric power system. This model traces rays from 50 points on the face of the sun to 10 points on each of the 456 collector facets. The triangular facets are modeled with spherical, parabolic, or toroidal reflective surface contour and surface slope errors. The rays are then traced through the receiver aperture to the walls of the receiver. Images of the collector and of the sun within the receiver produced by this code provide insight into the collector receiver interface. Flux distribution on the receiver walls, plotted by this code, is improved by a combination of changes to aperture location and receiver tilt angle. Power loss by spillage at the receiver aperture is computed and is considerably reduced by using toroidal facets.

Jefferies, Kent S.↗

Q-Band (37 to 41 GHz) Satellite Beacon Architecture for RF Propagation Experiments

In this paper, the design of a beacon transmitter that will be flown as a hosted payload on a geostationary satellite to enable propagation experiments at Q-band (37 to 41 GHz) frequencies is presented. The beacon uses a phased locked loop stabilized dielectric resonator oscillator and a solid-state power amplifier to achieve the desired output power. The satellite beacon antenna is configured as an offset-fed cutparaboloidal reflector.

Simons, Rainee N.↗

Q-Band (37-41 GHz) Satellite Beacon Architecture for RF Propagation Experiments

In this paper, the design of a beacon transmitter that will be flown as a hosted payload on a geostationary satellite to enable propagation experiments at Q-band (37-41 GHz) frequencies is presented. The beacon uses a phased locked loop stabilized dielectric resonator oscillator and a solid-state power amplifier to achieve the desired output power. The satellite beacon antenna is configured as an offset-fed cut-paraboloidal reflector.

Simmons, Rainee N.↗