Cohesive Modeling of Transverse Cracking in Laminates with a Single Layer of Elements per Ply

This study aims to bridge the gap between classical understanding of transverse cracking in cross-ply laminates and recent computational methods for the modeling of progressive laminate failure. Specifically, the study investigates under what conditions a finite element model with cohesive X-FEM cracks can reproduce the in situ effect for the ply strength. It is shown that it is possible to do so with a single element across the thickness of the ply, provided that the interface stiffness is properly selected. The optimal value for this interface stiffness is derived with an analytical shear lag model. It is also shown that, when the appropriate statistical variation of properties has been applied, models with a single element through the thickness of a ply can predict the density of transverse matrix cracks

VanDerMeer, Frans P.↗

High-Fidelity Computational Methodology for Stitched Composite Aerospace Structures

Due to the high demands for energy efficient commercial transportation, the aviation industry has taken a leading role in the integration of composite structures. Among the leading concepts to develop lighter, more fuel-efficient commercial transport is the Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) concept, an enabling technology for hybrid wing bodies. Many proof-of-concept tests have been performed to demonstrate that the use of PRSEUS has improved the residual strength of damaged structures compared to conventional composite structures, but efficient computational tools must be developed before the concept can be commercially certified and implemented. In an attempt to address the need for efficient computational tools, a comprehensive modeling approach is developed and applied to investigate applications of PRSEUS at multiple scales. Therefore, a computational methodology has been progressively developed based on physically realistic concepts. The focus of the work described herein is to define the modeling characteristics required to accurately simulate the damage progression and failure of PRSEUS at the coupon scale. The work herein is focused on the development and analysis of a PRSEUS stringer, the methodology for which may be extended to other PRSEUS coupons and components.

Brandon Horton↗

Quasi-Static and Dynamic Analysis of Composite Panels: Characterization and Validation

The predictive capability of a progressive damage model to simulate the quasi-static and dynamic crushing of composite specimens is evaluated in this article. The material model is commercially available within the ABAQUS finite element software package, i.e., “Damage for Fiber reinforced Composites”, and is often utilized to simulate damage progression and failure in static and dynamic failure scenarios such as crushing of a composite plate. The composite specimens used in this study consist of quasi-isotropic C-shaped and corrugated composite panels comprised of carbon fiber/epoxy braided fabric. The C-shaped panel specimen is used to calibrate the model and optimize material/model properties through comparison with experimental results. Then, using the same model parameters, the quasi-static crush response of the corrugated panel is predicted. The predictive capability of the model is further demonstrated by simulating the dynamic crushing response of both C-shaped and corrugated panels using the same material properties as in the quasi-static crush case with only minor adjustments for the dynamic elastic properties (i.e., rate dependent modulus). Results show that the in-built material model available in ABAQUS can successfully reproduce experimental results for both panels (C-shaped and corrugated) subjected to both quasi-static and dynamic loading scenarios. A small-scale parametric study on physical (experimentally measurable) and nonphysical (purely mathematical) model parameters was also conducted. It can be concluded that, achieving successful simulation results requires a more in-depth understanding of the influence of model parameter variation on the mechanical response of the composite together with the strategies and challenges of the utilized modeling methodology (e.g., FEA mesh density, etc.).

Naghipour Ghezeljeh, Paria↗

Toughening of Boron Carbide Composites by Hierarchical Microstructuring

Due to a unique combination of properties including high hardness, low density, chemical and thermal stability, semi-conductivity, and high neutron absorption, boron carbide (B4C) is a potential candidate for various applications involving extreme environment. However, B4C’s current application is limited because of its low fracture toughness. In this study, a hierarchical microstructure design with features including TiB2 grains and graphite platelets was used to toughen B4C by simultaneously utilizing multiple toughening mechanisms including crack deflection, bridging, and micro-crack toughening. Using field-assisted sintering technology (FAST), B4C composites with dense and hierarchical microstructure were fabricated. Previously, the fracture toughness of fabricated B4C composites was measured at micro-scale using micro-indentation to have up to 56% improvement. In this work, the B4C composites’ fracture toughness was characterized at macro-scale using four-point bending methods and compared with previous results obtained at micro-scale. Micromechanics modeling of fracture behaviors for B4C-TiB2 composites was also performed to evaluate the contributions from experimentally observed toughening mechanisms. From four-point bending tests, B4C composites reinforced with both TiB2 grains (~15 vol%) and graphite platelets (~8.7 vol%) exhibited the highest fracture toughness enhancement from 2.38 to 3.65 MPa∙m^(1/2). The measured values were lower than those obtained using micro-indentation but maintained the general trends. The discrepancy between the indentation and four-point bending test results originated from the complex deformation behaviors triggered by the high contact load during indentation tests. Through micromechanics modeling, introduced thermal residual stress due to thermal expansion mismatch between B4C and TiB2, and weak interphases at B4C-TiB2 boundaries were identified as the main causes for experimentally observed toughness enhancement. These results proved the effectiveness of hierarchical microstructure designs for B4C toughening and can provide reference for the future design of B4C composites with optimized microstructures for further fracture toughness enhancement.

composites↗

Lessons Learned from the Arecibo Observatory Auxiliary M4N Socket Analysis and Implications for Future Observatory Designs

The Arecibo Observatory collapsed after a progressive structural failure stemming from the failure of a single socket joint cable termination. A failure investigation was conducted to identify the cause of the first failed cable termination socket. Due to the nature of the suspended observatory receiver, the dominant source of loading in the suspension cables was due to deadload, with secondary contributions coming from environmental effects and observatory operation. The high ratio of deadload vs. live load applied to the cable over many years resulted in a creep failure mode of the cast zinc within the socket which further induced stress into the highly stress wires at the entrance of the socket. The design of the socket joint did not explicitly consider socket constituent stress margins and time-dependent damage mechanisms such as creep. Lessons learned from this investigation led to recommendations for revising civil engineering cable standards, and recommendations for manufacturers and designers. The design of cables employing socket terminations should consider the cumulative damage effects from creep and cyclic loading identify their corresponding worst-case inspectable defects or establish a sufficiently high factor of safety so that the design is sufficiently robust to defects and time-dependent failure modes. The design should specify end-of-life capability and set service life inspection intervals with pass/fail inspection criteria. Finally, trial studies on design iterations were conducted to increase the reliability of cables with socket joints.

Pavel Babuska↗

GENOA-PFA: Progressive Fracture in Composites Simulated Computationally

GENOA-PFA is a commercial version of the Composite Durability Structural Analysis (CODSTRAN) computer program that simulates the progression of damage ultimately leading to fracture in polymer-matrix-composite (PMC) material structures under various loading and environmental conditions. GENOA-PFA offers several capabilities not available in other programs developed for this purpose, making it preferable for use in analyzing the durability and damage tolerance of complex PMC structures in which the fiber reinforcements occur in two- and three-dimensional weaves and braids. GENOA-PFA implements a progressive-fracture methodology based on the idea that a structure fails when flaws that may initially be small (even microscopic) grow and/or coalesce to a critical dimension where the structure no longer has an adequate safety margin to avoid catastrophic global fracture. Damage is considered to progress through five stages: (1) initiation, (2) growth, (3) accumulation (coalescence of propagating flaws), (4) stable propagation (up to the critical dimension), and (5) unstable or very rapid propagation (beyond the critical dimension) to catastrophic failure. The computational simulation of progressive failure involves formal procedures for identifying the five different stages of damage and for relating the amount of damage at each stage to the overall behavior of the deteriorating structure. In GENOA-PFA, mathematical modeling of the composite physical behavior involves an integration of simulations at multiple, hierarchical scales ranging from the macroscopic (lamina, laminate, and structure) to the microscopic (fiber, matrix, and fiber/matrix interface), as shown in the figure. The code includes algorithms to simulate the progression of damage from various source defects, including (1) through-the-thickness cracks and (2) voids with edge, pocket, internal, or mixed-mode delaminations.

Murthy, Pappu L. N.↗

Large Area Nondestructive Evaluation of a Fatigue Loaded Composite Structure

Large area nondestructive evaluation (NDE) inspections are required for fatigue testing of composite structures to track damage initiation and growth. Of particular interest is the progression of damage leading to ultimate failure to validate damage progression models. In this work, passive thermography and acoustic emission NDE were used to track damage growth up to failure of a composite three-stringer panel. Fourteen acoustic emission sensors were placed on the composite panel. The signals from the array were acquired simultaneously and allowed for acoustic emission location. In addition, real time thermal data of the composite structure were acquired during loading. Details are presented on the mapping of the acoustic emission locations directly onto the thermal imagery to confirm areas of damage growth leading to ultimate failure. This required synchronizing the acoustic emission and thermal data with the applied loading. In addition, processing of the thermal imagery which included contrast enhancement, removal of optical barrel distortion and correction of angular rotation before mapping the acoustic event locations are discussed.

Joseph N Zalameda↗

DIVA/DeviceEditor (DIVA) v6.0.0

The DIVA software interfaces a process in which researchers design their DNA with a web-based graphical user interface (DeviceEditor), submit their designs to a central queue, and a few weeks later receive their sequence-verified clonal constructs. Each researcher independently designs the DNA to be constructed with a web-based BioCAD tool, and presses a button to submit their designs to a central queue. Researchers have web-based access to their DNA design queues, and can track the progress of their submitted designs as they progress from "evaluation", to "waiting for reagents", to "in progress", to "complete". Researchers access their completed constructs through the central DNA repository. Along the way, all DNA construction success/failure rates are captured in a central database. Once a design has been submitted to the queue, a small number of dedicated staff evaluate the design for feasibility and provide feedback to the responsible researcher if the design is either unreasonable (e.g., encompasses a combinatorial library of a billion constructs) or small design changes could significantly facilitate the downstream implementation process. The dedicated staff then use DNA assembly design automation software to optimize the DNA construction process for the design, leveraging existing parts from the DNA repository where possible and ordering synthetic DNA where necessary. Once all requisite process inputs are available, the design progresses from "waiting for reagents" to "in progress" in the design queue. Human-readable and machine-parseable DNA construction protocols output by the DNA assembly design automation software are then executed by the dedicated staff exploiting lab automation devices wherever possible. Since the all employed DNA construction methods are sequence-agnostic, standardized (utilize the same enzymatic master mixes and reaction conditions), completely independent DNA construction tasks can be aggregated into the same multi-well plates and pursued in parallel. The resulting sets of cloned constructs can then be screened by high-throughput next-gen sequencing platforms for sequence correctness. A combination of long read-length (e.g., PacBio) and paired-end read platforms (e.g., Illumina) would be exploited depending the particular task at hand (e.g., PacBio might be sufficient to screen a set of pooled constructs with significant gene divergence). Post sequence verification, designs for which at least one correct clone was identified will progress to a "complete" status, while designs for which no correct clones were identified will progress to a "failure" status. Depending on the failure mode (e.g., no transformants), and how many prior attempts/variations of assembly protocol have been already made for a given design, subsequent attempts may be made or the design can progress to a "permanent failure" state. All success and failure rate information will be captured during the process, including at which stage a given clonal construction procedure failed (e.g., no PCR product) and what the exact failure was (e.g. assembly piece 2 missing). This success/failure rate data can be leveraged to refine the DNA assembly design process.

Plahar, Hector↗

NEXT Long-Duration Test Neutralizer Performance and Erosion Characteristics

The NASA's Evolutionary Xenon Thruster (NEXT) program is developing the next-generation ion propulsion system with significant enhancements beyond the state-of-the-art to provide future NASA science missions with enhanced capabilities at a low total development cost. A Long-Duration Test (LDT) was initiated in June 2005, to verify the NEXT propellant throughput capability to a qualification-level of 450 kg, 1.5 times the anticipated throughput requirement of 300 kg per thruster based on mission analyses. As of September 2, 2009, the thruster has accumulated 24,400 hr of operation with extensive durations at the following input powers: 6.9, 4.7, 1.1, and 0.5 kW. The thruster has processed 434 kg of xenon, surpassing the NASA Solar Technology Application Readiness (NSTAR) program thruster propellant throughput demonstrated during the extended life testing of the Deep Space 1 flight spare ion thruster and approaching the NEXT development qualification throughput goal of 450 kg. The NEXT LDT has demonstrated a total impulse of 16.1 10(exp 6zzz0 N s; the highest total impulse ever demonstrated by an ion thruster. A reduction in neutralizer flow margin has been the only appreciable source of thruster performance degradation. The behavior of the neutralizer is not easily predicted due to both erosion and deposition observed in previous wear tests. Spot-to-plume mode transition flow data and in-situ erosion results for the LDT neutralizer are discussed. This loss of flow margin has been addressed through a combination of a design change in the prototype-model neutralizer to increase flow margin at low emission current and to update the NEXT throttle table to ensure adequate flow margin as a function of propellant throughput processed. The new throttle table will be used for future LDT operations. The performance of the NEXT LDT neutralizer is consistent with that observed for long-life hollow cathodes. The neutralizer life-limiting failure modes are progressing as expected and the neutralizer data indicate none of the neutralizer failures are imminent.

Herman, Daniel A.↗

Finite Element Model for Failure Study of Two-Dimensional Triaxially Braided Composite

A new three-dimensional finite element model of two-dimensional triaxially braided composites is presented in this paper. This meso-scale modeling technique is used to examine and predict the deformation and damage observed in tests of straight sided specimens. A unit cell based approach is used to take into account the braiding architecture as well as the mechanical properties of the fiber tows, the matrix and the fiber tow-matrix interface. A 0 deg / plus or minus 60 deg. braiding configuration has been investigated by conducting static finite element analyses. Failure initiation and progressive degradation has been simulated in the fiber tows by use of the Hashin failure criteria and a damage evolution law. The fiber tow-matrix interface was modeled by using a cohesive zone approach to capture any fiber-matrix debonding. By comparing the analytical results to those obtained experimentally, the applicability of the developed model was assessed and the failure process was investigated.

Li, Xuetao↗

Numerical Predictions of Damage and Failure in Carbon Fiber Reinforced Laminates Using a Thermodynamically-Based Work Potential Theory

A thermodynamically-based work potential theory for modeling progressive damage and failure in fiber-reinforced laminates is presented. The current, multiple-internal state variable (ISV) formulation, referred to as enhanced Schapery theory (EST), utilizes separate ISVs for modeling the effects of damage and failure. Consistent characteristic lengths are introduced into the formulation to govern the evolution of the failure ISVs. Using the stationarity of the total work potential with respect to each ISV, a set of thermodynamically consistent evolution equations for the ISVs are derived. The theory is implemented into a commercial finite element code. The model is verified against experimental results from two laminated, T800/3900-2 panels containing a central notch and different fiber-orientation stacking sequences. Global load versus displacement, global load versus local strain gage data, and macroscopic failure paths obtained from the models are compared against the experimental results.

composite materials↗

Computational Simulation of Damage Progression of Composite Thin Shells Subjected to Mechanical Loads

Defect-free and defected composite thin shells with ply orientation (90/0/+/-75) made of graphite/epoxy are simulated for damage progression and fracture due to internal pressure and axial loading. The thin shells have a cylindrical geometry with one end fixed and the other free. The applied load consists of an internal pressure in conjunction with an axial load at the free end, the cure temperature was 177 C (350 F) and the operational temperature was 21 C (70 F). The residual stresses due to the processing are taken into account. Shells with defect and without defects were examined by using CODSTRAN an integrated computer code that couples composite mechanics, finite element and account for all possible failure modes inherent in composites. CODSTRAN traces damage initiation, growth, accumulation, damage propagation and the final fracture of the structure. The results show that damage initiation started with matrix failure while damage/fracture progression occurred due to additional matrix failure and fiber fracture. The burst pressure of the (90/0/+/- 75) defected shell was 0.092% of that of the free defect. Finally the results of the damage progression of the (90/0/+/- 75), defective composite shell was compared with the (90/0/+/- theta, where theta = 45 and 60, layup configurations. It was shown that the examined laminate (90/0/+/- 75) has the least damage tolerant of the two compared defective shells with the (90/0/+/- theta), theta = 45 and 60 laminates.

Gotsis, P. K.↗

Angiotensin-converting enzyme and matrix metalloproteinase inhibition with developing heart failure: comparative effects on left ventricular function and geometry

The progression of congestive heart failure (CHF) is left ventricular (LV) myocardial remodeling. The matrix metalloproteinases (MMPs) contribute to tissue remodeling and therefore MMP inhibition may serve as a useful therapeutic target in CHF. Angiotensin converting enzyme (ACE) inhibition favorably affects LV myocardial remodeling in CHF. This study examined the effects of specific MMP inhibition, ACE inhibition, and combined treatment on LV systolic and diastolic function in a model of CHF. Pigs were randomly assigned to five groups: 1) rapid atrial pacing (240 beats/min) for 3 weeks (n = 8); 2) ACE inhibition (fosinopril, 2.5 mg/kg b.i.d. orally) and rapid pacing (n = 8); 3) MMP inhibition (PD166793 2 mg/kg/day p.o.) and rapid pacing (n = 8); 4) combined ACE and MMP inhibition (2.5 mg/kg b.i.d. and 2 mg/kg/day, respectively) and rapid pacing (n = 8); and 5) controls (n = 9). LV peak wall stress increased by 2-fold with rapid pacing and was reduced in all treatment groups. LV fractional shortening fell by nearly 2-fold with rapid pacing and increased in all treatment groups. The circumferential fiber shortening-systolic stress relation was reduced with rapid pacing and increased in the ACE inhibition and combination groups. LV myocardial stiffness constant was unchanged in the rapid pacing group, increased nearly 2-fold in the MMP inhibition group, and was normalized in the ACE inhibition and combination treatment groups. Increased MMP activation contributes to the LV dilation and increased wall stress with pacing CHF and a contributory downstream mechanism of ACE inhibition is an effect on MMP activity.

Non-NASA Center↗

Use of Acoustic Emission to Monitor Progressive Damage Accumulation in Kevlar (R) 49 Composites

Acoustic emission (AE) data acquired during intermittent load hold tensile testing of epoxy impregnated Kevlar(Registeres TradeMark) 49 (K/Ep) composite strands were analyzed to monitor progressive damage during the approach to tensile failure. Insight into the progressive damage of K/Ep strands was gained by monitoring AE event rate and energy. Source location based on energy attenuation and arrival time data was used to discern between significant AE attributable to microstructural damage and spurious AE attributable to noise. One of the significant findings was the observation of increasing violation of the Kaiser effect (Felicity ratio < 1.0) with damage accumulation. The efficacy of three different intermittent load hold stress schedules that allowed the Felicity ratio to be determined analytically is discussed.

Waller, Jess M.↗

In-Situ NDE Characterization of Kevlar and Carbon Composite Micromechanics for Improved COPV Health Monitoring

This project is a subtask of a multi-center project to advance the state-of-the-art by developing NDE techniques that are capable of evaluating stress rupture (SR) degradation in Kevlar/epoxy (K/Ep) composite overwrapped pressure vessels (COPVs), and damage progression in carbon/epoxy (C/Ep) COPVs. In this subtask, acoustic emission (AE) data acquired during intermittent load hold tensile testing of K/Ep and C/Ep composite tow materials-of-construction used in COPV fabrication were analyzed to monitor progressive damage during the approach to tensile failure. Insight into the progressive damage of composite tow was gained by monitoring AE event rate, energy, source location, and frequency. Source location based on arrival time data was used to discern between significant AE attributable to microstructural damage and spurious AE attributable to background and grip noise. One of the significant findings was the observation of increasing violation of the Kaiser effect (Felicity ratio < 1.0) with damage accumulation.

Waller, Jess M.↗

Internal short circuit and failure mechanisms of lithium-ion pouch cells under mechanical indentation abuse conditions: An experimental study

Electromechanical structural integrity and thermal stability dictate the safety performance of lithium-ion batteries. Progressive deformation and failure across microscopic and macroscopic lengths scales that are responsible for internal short circuit (ISC) in lithium-ion cells under mechanical abuse conditions remains elusive. In this study, a series of indentation tests were conducted on lithium-ion cells with different capacities up to the occurrence of ISC. The external response and internal configuration of these cells were investigated. It is discovered that cells with different capacities and state of charges exhibited different behaviors. Maximum temperature, which is often regarded as the most important parameter related to thermal runaway (TR), varied considerably due to the complicated contact configurations. X-ray computed tomography (XCT) showed that ISC was a collective result of shear band or other strain-localization modes in the electrode assembly, shear offsets in the granular coatings of electrodes, and the accompanying ductile fracture in the metal foils. We believe that the irregular strain-localization modes (kinks, cusps, and buckles), radical mismatches in mechanical properties of different layers, and geometric features of the indenter eventually lead to the tearing/puncture of cell separator at various locations. Furthermore, the results could provide useful guidance for the micromechanical modeling of lithium-ion cells.