Search NASA⌕ Search

SEARCH · Search NASA

Results for “REFRACTIVE INDEX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Tunable effective nonlinear refractive index of graphene dispersions during the distortion of spatial self-phase modulation

Spatial self-phase modulation (SSPM) was observed directly when a focused He-Ne laser beam at 633 nm went through liquid-phase-exfoliated graphene dispersions. The diffraction pattern of SSPM was found to be distorted rapidly right after the incident beam horizontally passing through the dispersions, while no distortion for the vertically incident geometry. We show that the distortion is originated mainly from the non-axis-symmetrical thermal convections of the graphene nanosheets induced by laser heating, and the relative change of nonlinear refractive index can be determined by the ratio of the distortion angle to the half-cone angle. Therefore, the effective nonlinear refractive index of graphene dispersions can be tuned by changing the incident intensity and the temperature of the dispersions.

36 MATERIALS SCIENCE↗

Single-shot measurement of the nonlinear refractive index of air at 92 µm with a picosecond terawatt CO 2 laser

We developed a simple, accurate single-shot method to determine the nonlinear refractive index of air by measuring the evolution of the spatial shape of a laser beam propagating through the atmosphere. A distinctive feature of this new method, which relies on a modified Fresnel propagation model for data analysis, is the use of a hard aperture for producing a welldefined, high-quality beam from a comparatively nonuniform quasi-flat-top beam which is typical for highpeak-power lasers. The nonlinear refractive index of air for a very short (2 ps) long-wave infrared (LWIR) laser pulse was measured for the first time, yielding n 2 = 3.0 × 10 -23 m 2 /W at 9.2 µm. This result is 40% lower than a corresponding measurement with longer (200 ps) LWIR pulses at a similar wavelength.

43 PARTICLE ACCELERATORS↗

High optical transparency polymer aerogels using low refractive index monomers

A polymer aerogel has polymerizable monomers and crosslinkers, wherein at least one of the monomers or at least one of the crosslinkers has a refractive index of less than 1.5, and the polymer aerogel has a visible transmittance of at least 20%/3 mm, a haze of 50%/3 mm or lower, and a porosity of at least 10%. A method of producing an aerogel includes dissolving precursors into a solvent, wherein the precursors include monomers, crosslinkers, a controlling agent and an initiator to form a precursor solution, wherein at least one of the monomers or at least one of the crosslinkers has a refractive index of 1.5 or lower, polymerizing the precursor solution to form a gel polymer, and removing the solvent from the gel polymer to produce an aerogel polymer.

Bulger, Eli↗

Temperature-dependent Refractive Index of CaF2 and Infrasil 301

In order to enable high quality lens designs using calcium fluoride (CaF2) and Heraeus Infrasil 301 (Infrasil) for cryogenic operating temperatures, we have measured the absolute refractive index of these two materials as a function of both wavelength and temperature using the Cryogenic, High-Accuracy Refraction Measuring System (CHARMS) at NASA's Goddard Space Flight Center. For CaF2, we report absolute refractive index and thermo-optic coefficient (dn/dT) at temperatures ranging from 25 to 300 K at wavelengths from 0.4 to 5.6 pm, while for Infrasil, we cover temperatures ranging from 35 to 300 K and wavelengths from 0.4 to 3.6 pm. For CaF2, we compare our index measurements to measurements of other investigators. For Infrasil, we compare our measurements to the mate~al manufacturer's data at room temperature and to cryogenic measurements for fused silica from previous investigations including one of our own. Finally, we provide temperature-dependent Sellmeier coefficients based on our measured data to allow accurate interpolation of index to other wavelengths and temperatures.

Leviton, Douglas B.↗

Sound speed and refractive index of amorphous CaSiO3 upon pressure cycling to 40 GPa

Abstract Brillouin spectroscopy at room temperature and pressures up to 40 GPa documents nearly identical elasticity and refractive index of amorphous CaSiO3 created by two different methods: temperature-quenching the melt at ambient pressure and pressure-amorphizing crystalline wollastonite at room temperature. We find reproducible hysteresis of 0 to 8% on pressure cycling that is small relative to the 30 to 60% changes in shear and longitudinal wave velocities over this pressure range. Together with observed changes in refractive index and previous results from Raman spectroscopy, these measurements reveal a continuous and reversible change in atomic packing induced by pressure. Unlike many other silicate glasses, amorphous CaSiO3 exhibits highly reproducible properties, behaving smoothly and reversibly under pressure cycling and possessing similar structure and elasticity regardless of synthesis paths for the starting material, which suggests that the amorphous solid may mimic the liquid over the pressure range investigated.

Geochemistry & Geophysics↗

Refractive Index Seen by a Probe Beam Interacting with a Laser-Plasma System

Here, we report the first complete set of measurements of a laser-plasma optical system’s refractive index, as seen by a second probe laser beam, as a function of the relative wavelength shift between the two laser beams. Both the imaginary and real refractive index components are found to be in good agreement with linear theory using plasma parameters measured by optical Thomson scattering and interferometry; the former is in contrast to previous work and has implications for crossed-beam energy transfer in indirect-drive inertial confinement fusion, and the latter is measured for the first time. The data include the first demonstration of a laser-plasma polarizer with 85$-$87% extinction for the particular laser and plasma parameters used in this experiment, complementing the existing suite of high-power, tunable, and ultrafast plasma-based photonic devices.

42 ENGINEERING↗

Effect of optical pumping on the refractive index and temperature in the core of active fibre

This paper examines the refractive index change (RIC) induced in the core of Yb{sup 3+}-doped active silica fibres by pulsed pumping. RIC kinetic measurements with a Mach - Zehnder interferometer make it possible to separately assess the contributions of the electronic and thermal mechanisms to the RIC and evaluate temperature nonuniformities in the fibre.

36 MATERIALS SCIENCE↗

Determination of the thickness and spectral dependence of the refractive index of Al{sub x}In{sub 1-x}Sb epitaxial layers from reflectance spectra

A nondestructive method for measuring the thicknesses of epitaxial layers of Al{sub x}In{sub 1-x}Sb alloys based on interference effects in reflectance spectra measured in a wide wavelength range (1-28 {mu}m) is implemented. The studied 0.9-3.3 {mu}m thick Al{sub x}In{sub 1-x}Sb layers are grown on highly lattice-mismatched GaAs substrates by molecular beam epitaxy. The found thicknesses are in good agreement with the independent data of scanning electron microscopy. The spectral dependence of the refractive index n(E) of Al{sub x}In{sub 1-x}Sb layers is measured both for the regions of transparency and fundamental absorption. The refractive index for the case of E < E{sub 0} was calculated by a double-oscillator model using a refined experimental dependence of the band gap on the composition E{sub 0}(x). The experimental data on the n(E) of Al{sub x}In{sub 1-x}Sb for energies E > E{sub 0} are found based on the interference pattern.

36 MATERIALS SCIENCE↗

Nanoimprinted High-Refractive Index Active Photonic Nanostructures Based on Quantum Dots for Visible Light

A novel method to realizing printed active photonic devices was developed using nanoimprint lithography (NIL), combining a printable high-refractive index material and colloidal CdSe/CdS quantum dots (QDs) for applications in the visible region. Active media QDs were applied in two different ways: embedded inside a printable high-refractive index matrix to form an active printable hybrid nanocomposite, and used as a uniform coating on top of printed photonic devices. As a proof-of-demonstration for printed active photonic devices, two-dimensional (2-D) photonic crystals as well as 1D and 2D photonic nanocavities were successfully fabricated following a simple reverse-nanoimprint process. We observed enhanced photoluminescence from the 2D photonic crystal and the 1D nanocavities. Outstandingly, the process presented in this study is fully compatible with large-scale manufacturing where the patterning areas are only limited by the size of the corresponding mold. This work shows that the integration of active media and functional materials is a promising approach to the realization of integrated photonics for visible light using high throughput technologies. We believe that this work represents a powerful and cost-effective route for the development of numerous nanophotonic structures and devices that will lead to the emergence of new applications.

36 MATERIALS SCIENCE↗

Refractive index of erbium doped GaN thin films

GaN is an excellent host for erbium (Er) to provide optical emission in the technologically important as well as eye-safe 1540 nm wavelength window. Er doped GaN (GaN:Er) epilayers were synthesized on c-plane sapphire substrates using metal organic chemical vapor deposition. By employing a pulsed growth scheme, the crystalline quality of GaN:Er epilayers was significantly improved over those obtained by conventional growth method of continuous flow of reaction precursors. X-ray diffraction rocking curve linewidths of less than 300 arc sec were achieved for the GaN (0002) diffraction peak, which is comparable to the typical results of undoped high quality GaN epilayers and represents a major improvement over previously reported results for GaN:Er. Spectroscopic ellipsometry was used to determine the refractive index of the GaN:Er epilayers in the 1540 nm wavelength window and a linear dependence on Er concentration was found. The observed refractive index increase with Er incorporation and the improved crystalline quality of the GaN:Er epilayers indicate that low loss GaN:Er optical waveguiding structures are feasible.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On the feasibility of optical-CT imaging in media of different refractive index

Purpose: Achieving accurate optical-CT 3D dosimetry without the use of viscous refractive index (RI) matching fluids would greatly increase convenience. Methods: Software has been developed to simulate optical-CT 3D dosimetry for a range of scanning configurations including parallel-beam, point, and converging light sources. For each configuration the efficacy of three refractive media was investigated: air, water, a fluid closely matched to PRESAGE{sup Registered-Sign }, and perfect matching (RI = 1.00, 1.33, 1.49, and 1.501 respectively). Reconstructions were performed using both filtered backprojection (FBP) and algebraic reconstruction technique (ART). The efficacy of the three configurations and the two algorithms was evaluated by calculating the usable radius (i.e., the outermost radius where data were accurate to within 2%), and gamma ({Gamma}) analysis. This definition recognizes that for optical-CT imaging, errors are greatest near the edge of the dosimeter, where refraction can be most pronounced. Simulations were performed on three types of dose distribution: uniform, volumetric modulated arc therapy (VMAT), and brachytherapy (Cs-137). Results: For a uniformly irradiated dosimeter the usable radius achieved with filtered backprojection was 68% for water-matching and 31% for dry-scanning in air. Algebraic reconstruction gave usable radii of 99% for both water and air (dry-scanning), indicating greater recovery of useful data for the uniform distribution. FBP and ART performed equally well for a VMAT dose distribution where less dose is delivered near the edge of the dosimeter. In this case, the usable radius was 86% and 53% for scanning in water and air, respectively. For brachytherapy, the usable radius was 99% and 98% for scanning in water and air, respectively using FBP, and a major decrease was seen with ART. Point source geometry provided 1%-2% larger usable radii than parallel geometry. Converging geometry recovered less usable dosimetry data (up to 10% reduced usable radii) than point and parallel geometries. A further disadvantage of converging geometry was an increased requirement on detector size by up to 18 Degree-Sign . Conclusions: For applications where dose information is not required in the periphery of the dosimeter, some dry and low-viscous matching configurations may be feasible. For all three dose distributions (uniform, VMAT, brachytherapy) the point source geometry produced slightly more favorable results (an extra 1%-2% usable radii) than parallel and converging. When dosimetry is required on the periphery, best results were obtained using close refractive matching and ART. A concern for water or dry-scanning is the increase in required detector size, introducing potential cost penalties for manufacturing.

36 MATERIALS SCIENCE↗

Complex Refractive Index of Ammonium Nitrate in the 2-20 micron Spectral Range

Using high resolution Fourier Transform Infrared Spectroscopy (FTIR) absorbance/transmittance spectral data for ammonium sulfate (AMS), calcium carbonate (CAC) and ammonium nitrate (AMN), comparisons were made with previously published complex refractive indices data for AMS and CAC to infer experimental parameters to determine the imaginary refractive index for AMN in the infrared wavelength range from 2 to 20 microns. Kramers-Kronig mathematical relations were applied to calculate the real refractive index for the three compositions. Excellent agreement for AMS and CAC with the published values was found, validating the complex refractive indices obtained for AMN. Backscatter calculations using a lognormal size distribution for AMS, AMN, and CAC aerosols were performed to show differences in their backscattered spectra.

Jarzembski, Maurice A.↗

Fuel film thickness measurements using refractive index matching in a stratified-charge SI engine operated on E30 and alkylate fuels

This paper shows fuel film measurements in a spark-ignited direct injection engine using refractive index matching (RIM). The RIM technique is applied to measure the fuel impingement of a high research octane number gasoline fuel with 30 vol% ethanol content at two intake pressures and coolant temperatures. Measurements are conducted for an alkylate fuel at one operating case, as well. It is shown that the fuel volume on the piston surface increases for lower intake pressure and lower coolant temperature and that the alkylate fuel shows very little spray impingement. The fuel films can be linked to increased soot emissions. A detailed description of the calibration technique is provided and measurement uncertainties are discussed. The dependency of the RIM signal on refractive index changes is measured. The RIM technique provides quantitative film thickness measurements up to 0.9 µm in this engine. Finally, for thicker films, semi-quantitative results of film thickness can be utilized to study the distribution of impinged fuel.

42 ENGINEERING↗

Planar waveguide structures based on SrF{sub 2}: Ho, Er, Tm. Dependence of the refractive index on the dopant concentration

Refractive indices of SrF{sub 2} crystals doped with holmium, erbium, and thulium ions are measured. These crystals are used as active laser media, in particular, as materials for planar waveguides. The presence of active ions in these crystals may create a difference between the refractive indices of the cladding and the doped core of a planar waveguide. At dopant concentration to 4 %, the difference Δn between the refractive indices of the doped core and undoped reflective layer can reach 0.007.

36 MATERIALS SCIENCE↗

Method of time resolved refractive index measurements of x-ray laser heated solids

With the advent of new x-ray light-sources worldwide, the creation of dense, uniformly heated plasma states arising from intense x-ray irradiation of solids has been made possible. In the early stages of x-ray solid heating, before significant hydrodynamic motion occurs, the matter exists in a highly non-equilibrium state. A method based on wavefront sensing is proposed to probe some of the fundamental properties of these states. The deflection and absorption of a high harmonic probe beam propagated through the plasma can be measured with a wavefront sensor, and allow for the determination of the complex refractive index (RI) of the plasma, giving a 2D map of the optical properties as function of time in a pump-probe arrangement. A solid heating model has been used to estimate the expected temperatures of x-ray heated thin foils, and these temperatures are used in three separate models to estimate the changes in the refractive index. The calculations show the changes induced on an extreme ultra-violet (XUV) probe beam by a solid density thin foil plasma are significant, in terms of deflection angle and absorption, to be measured by already existing XUV Hartmann wavefront sensors. The method is applicable to a wide range of photon energies in the XUV (10 s to several 100 s of eV) and plasma parameters, and can add much needed experimental data to the fundamental properties of such dense plasma states.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mean effective size and refractive index of transparent atmospheric particulates

It is demonstrated that the scattering ratio-principle originally restricted to exact forward and exact backward scattering, and to values of the size parameter and of the product (refractive index x size parameter) less than 0.8 has a much wider applicability. After relaxing these stringent conditions, it is also shown that this principle can be retained as the basis of an experimental technique for retrieving the mean effective size and refractive index of transparent atmospheric particulates.

Fymat, A. L.↗