The Spallation Neutron Source Normal Conducting Linac RF System Design for the Proton Power Upgrade Project

The Proton Power Upgrade (PPU) project at the Spallation Neutron Source will double the available proton beam power from 1.4 to 2.8 MW by increasing the beam energy from 1.0 to 1.3 GeV and the beam current from 26 to 38 mA. The increase in beam current resulted in the need to redesign the existing normal conducting linac (NCL) RF Systems. High-power testing of the existing NCL RF Systems configured to accelerate PPU-level beam provided the data used to make the final design decisions. This paper describes the development and execution of those in-situ tests and the subsequent results.

Moss, John↗

Neutrino beam bunch structure reconstruction with precision timing in the ICARUS liquid argon time projection chamber

The ICARUS detector has been operating smoothly since 2021 as the far detector in the Short Baseline Neutrino (SBN) program at Fermilab, collecting neutrino interactions from both the Booster Neutrino Beam (BNB) and off-axis from the Neutrinos at the Main Injector (NuMI) beam. Analysis of neutrino interactions in ICARUS requires mitigation of substantial cosmogenic backgrounds. This is achieved by using an external Cosmic Ray Tagger (CRT) and a Photomultiplier Tube (PMT) system embedded in the liquid argon. The intrinsic neutrino beam bunch structure, inherited time structure from the Radio Frequency (RF) system used to accelerate the protons, can be resolved at the ICARUS detector using precise timing information. Located at shallow depth, ICARUS is exposed to a high flux of cosmic rays that can be mistaken for neutrino interactions. To mitigate this background, the CRT and a 3-meter-thick concrete overburden were installed. To better model backgrounds, ICARUS makes use of an overlay technique where simulated neutrino events are superimposed on detector beam-off data. PMTs installed within a Time Projection Chamber detect argon scintillation light emitted by high energy charged particles passing through the chamber and provide the event timing of neutrino interactions. The nanosecond-level beam bunch structure is reconstructed with the PMT system and can be used to further understand backgrounds and enhance neutrino physics capabilities. In this thesis, I will discuss background mitigation techniques using precision timing and present a novel technique to select neutrino events from our unbiased data stream using the beam bunch structure.

Heggestuen, Anna [Colorado State U.] (ORCID:000000↗

Ab-initio Cu alloy design for high-gradient accelerating structures

Operation of normal conducting accelerator structures at high accelerating gradients is beneficial for many accelerator applications in basic science, industry, medicine, and National Security. RF breakdown is the major factor that limits the achievable accelerating gradients. Previous experiments on copper (Cu) have demonstrated that RF breakdown probability can be significantly decreased by hardening the material and alloying Cu with solutes such as silver (Ag). In this paper, we propose a figure-of-merit (FOM) that characterizes the ability of Cu alloys to withstand high-gradients. The FOM represents a trade-off between hardening through solid solution strengthening and the additional thermal stress induced by incremental RF pulse heating resulting from changes in electronic properties induced by alloying. We performed high-throughput ab initio calculations and computed the FOM for a large number of binary Cu alloys. Several promising candidate alloys for high-gradient accelerating structures were identified, such as CuAg, CuCd, CuHg, CuAu, CuIn, and CuMg. CuAg alloys have previously exhibited low RF breakdown rates in experiments. The results provide guidance for selecting alloys for the future high-gradient normal conducting accelerating structures operating at very high gradients.

36 MATERIALS SCIENCE↗

Technical Report for Bayesian Optimization and Reinforcement Learning for Beam Polarization Increase in the BNL Hadron Injectors

This project developed and evaluated physics-informed Bayesian learning and machine learning (ML)-based optimization methods for improving beam polarization preservation in the BNL hadron injector chain. The work focused on uncertainty-aware digital twin modeling, Bayesian calibration of accelerator simulations using beam measurements, and data-efficient optimization strategies including Bayesian optimization and reinforcement learning. These methods were applied to injector tuning and RF control problems in realistic accelerator settings to support improved operational robustness and readiness for RHIC operations and future Electron–Ion Collider facilities. No subject inventions were disclosed under this award.

43 PARTICLE ACCELERATORS↗

Ir-192 radioisotope replacement with a hand-portable 1 MeV Ku-band electron linear accelerator

Although linear accelerators are used in many security, industrial and medical applications, the existing technologies are too large and expensive for several critical applications such as radioactive source replacement, field radiography and mobile cargo scanners. Here, one of the main requirements for these sources is to be highly portable to allow field operation. In response to this problem, RadiaBeam has designed a hand-portable 1 MeV X-ray source, scalable to higher energies, based on Ku-band split electron linac, that can be used for Ir-192 radioisotope replacement. In this paper, we present its multiphysics and engineering design studies, as well as an accelerating structure prototype along with RF measurements.

43 PARTICLE ACCELERATORS↗

Observations On Submicropulse Electron-beam Effects From Short-range Wakefields In Tesla-type Superconducting RF Cavities

aExperiments were performed at The Fermilab Accelerator Science and Technology (FAST) facility to elucidate the effects of short-range wakefields (SRWs) in TESLA-type rf cavities. FAST has a unique configuration of a photocathode rf gun beam injecting two TESLA-type single cavities (CC1 and CC2) in series prior to the cryomodule. To investigate short-range wakefield effects, we have steered the beam to minimize the signals in the higher-order mode (HOM) detectors of CC1 and CC2 for a baseline, and then selected a vertical corrector to steer the beam off axis at an angle into CC1 or CC2. A Hamamatsu synchro-scan streak camera viewing a downstream OTR screen provided an image of y-t effects within the micropulses with ~10-micron spatial resolution and 2-ps temporal resolution. At 500 pC/b, 50 b, and 2 mrad off-axis steering into CC2, we observed an ~ 100-micron head-tail centroid shift in the streak camera image y(t)-profiles. This centroid shift value is consistent wit h a calculated short-range wakefield effect using ASTRA simulations.

43 PARTICLE ACCELERATORS↗

DIRECT OBSERVATIONS OF SUBMICROPULSE ELECTRON-BEAM EFFECTS FROM SHORT-RANGE WAKEFIELDS IN TESLA-TYPE SUPERCONDUCTING RF CAVITIES

Experiments were performed at The Fermilab Accelerator Science and Technology (FAST) facility to elucidate the effects of short-range wakefields (SRWs) in TESLA-type rf cavities. FAST has a unique configuration of a photocathode rf gun beam injecting two TESLA-type single cavities (CC1 and CC2) in series prior to the cryomodule. To investigate short-range wakefield effects, we have steered the beam to minimize the signals in the higher-order mode (HOM) detectors of CC1 and CC2 for a baseline, and then used a vertical corrector between the two cavities to steer the beam off axis at an angle into CC2. A Hamamatsu synchroscan streak camera viewing a downstream OTR screen provided an image of y-t effects within the micropulses with ~10-micron spatial resolution and 2-ps temporal resolution. At 500 pC/b, 50 b, and 4 mrad off-axis steering into CC2, we observed an ~ 100-micron head-tail centroid shift in the streak camera image y(t)-profiles. This centroid shift value is 5 times l arger than the observed HOM-driven centroid oscillation within the macropulse, and it is consistent with a calculated short-range wakefield effect using ASTRA simulations.

43 PARTICLE ACCELERATORS↗

Design of a Low-Energy FARAD Thruster

The design of an electrodeless thruster that relies on a pulsed, rf-assisted discharge and electromagnetic acceleration using an inductive coil is presented. The thruster design is optimized using known performance,scaling parameters, and experimentally-determined design rules, with design targets for discharge energy, plasma exhaust velocity; and thrust efficiency of 100 J/pulse, 25 km/s, and 50%, respectively. Propellant is injected using a high-speed gas valve and preionized by a pulsed-RF signal supplied by a vector inversion generator, allowing for current sheet formation at lower discharge voltages and energies relative to pulsed inductive accelerators that do not employ preionization. The acceleration coil is designed to possess an inductance of at least 700 nH while the target stray (non-coil) inductance in the circuit is 70 nH. A Bernardes and Merryman pulsed power train or a pulse compression power train provide current to the acceleration coil and solid-state components are used to switch both powertrains.

Polzin, K. A.↗

PIP-II 800 MeV Proton Linac Beam Pattern Generator

The PIP2 IT Beam Pattern Generator is the system that synchronizes beam injection and the RF systems between the PIP2 LINAC to the Booster. The RF frequencies of these two accelerator systems are not harmonically related. Synchronization is accomplished by controlling two MEBT Beam Choppers, which select 162.5MHz beam bunches from the LEBT and RFQ to produce an appropriate reduced beam bunch pattern that enables bucket-to-bucket transfer to the Booster RF at 46.46MHz (84th harmonic). This chopping pattern also reduces the beam current to an average of 2mA over the Booster injection, matching the Linac nominal beam current. The BPG also generates the RF frequency/phase reference which the Booster will phase lock to during injection. The BPG is fully programmable, allowing for arbitrary beam patterns with adjustable timing parameters, having a fine adjustment resolution of 38ps. The latter is accomplished using digital signal processing techniques. This paper discusses the design of the BPG, its construction, test results, and operational experience after being integrated into the PIP2 IT test accelerator and concludes with a discussion of the system’s performance and future plans.

43 PARTICLE ACCELERATORS↗

Design and Preliminary Testing Plan of Electronegative Ion Thruster

Electronegative ion thrusters are a new iteration of existing gridded ion thruster technology differentiated by their ability to produce and accelerate both positive and negative ions. The primary motivations for electronegative ion thruster development include the elimination of lifetime-limiting cathodes from a thruster system and the ability to generate appreciable thrust through the acceleration of both positive or negative-charged ions. Proof-of-concept testing of the PEGASES (Plasma Propulsion with Electronegative GASES) thruster demonstrated the production of positively and negatively-charged ions (argon and sulfur hexafluoride, respectively) in an RF discharge and the subsequent acceleration of each charge species through the application of a time-varying electric field to a pair of metallic grids similar to those found in gridded ion thrusters. Leveraging the knowledge gained through experiments with the PEGASES I and II prototypes, the MINT (Marshall's Ion-ioN Thruster) is being developed to provide a platform for additional electronegative thruster proof-of-concept validation testing including direct thrust measurements. The design criteria used in designing the MINT are outlined and the planned tests that will be used to characterize the performance of the prototype are described.

Schloeder, Natalie R.↗

SRF Cavity Emulator for PIP-II LLRF Lab and Field Testing

There are many stages in the LLRF and RF system development process for any new accelerator that can take advantage of hardware emulation of the high-power RF system and RF cavities. LLRF development, bench testing, control system development and testing of installed systems must happen well before SRF cavities are available for test. The PIP-II Linac has three frequencies of SRF cavities, 162.5 MHz, 325 MHz and 650 MHz and a simple analog emulator design has been chosen that can meet the cavity bandwidth requirements, provide tuning errors to emulate Lorentz force detuning and microphonics for all cavity types. This emulator design utilizes a quartz crystal with a bandwidth of 65Hz at an IF of ~ 4 MHz, providing a Q of ~ 1.3 x 10^7 at 650MHz. This paper will discuss the design and test results of this emulator.

43 PARTICLE ACCELERATORS↗

Results of the first implementation of RF phase signature matching at LANSCE

The LINAC at the Los Alamos Neutron Science Center (LANSCE) has been utilizing the Delta-t method to match the RF cavities to the design acceleration parameters since its commissioning in 1972. The differences in time-of-flight between two subsequent Beam Position and Phase Monitors (BPPMs) are measured with both accelerated and drifting beams, depending on the whether the module is set to on or off. The algorithm optimizes the module amplitude and phase via iterative measurements if the initial phase is in the vicinity of the design value. With an upgrade to a faster readout system, a scan over the whole RF cavity phase range requires relatively less time than the classical optimization procedure. The Phase Scan Signature Matching (PSSM) method provides a time-efficient method that ensures the phase selection lands on the bunching side and empowers future analyses to build module-specific models. The PSSM also utilizes a direct model to determine the correct amplitude to sub-percent level instead of using linearized matrices. Furthermore, lacking a reliable energy measurement method in the LINAC, we measure the beam phases at two downstream locations to increase the precision of energy measurements. In this letter, we also discuss the sensitivities of PSSM, error propagation, and the implementation results for the 2019 and 2020 beam cycles.

47 OTHER INSTRUMENTATION↗

Pathway to tune sputter coated Nb$_3$Sn with Zr

Superconducting radio frequency (SRF) cavities are essential elements of many modern-day particle accelerators such as, European XFEL (DESY), LCLS II-HE (SLAC) and PIP II (Fermilab). Nb$_3$Sn superconducting material promises significant potential to exceed the performance of conventional niobium based SRF cavities. We aim to advance the ongoing R$&$D efforts to achieve Nb$_3$Sn coated cavities with high material quality. In this work, we have developed to achieve a route for effectively reducing the intrinsic defects in magnetron sputter coated Nb$_3$Sn SRF cavities and eventually improve the overall RF performance. We have observed that Zr is mainly being incorporated as ZrO$_2$ precipitates of average dimensions ranging from 20-100nm. By increasing the concentration of Zr, we have three major effects in the physical properties. Firstly, we noted that the density of the surface and bulk voids as well as their average dimensions are dramatically reduced on increasing the Zr content in Nb$_3$Sn. These surface voids are believed to be detrimental to cavity applications due to increase the local dissipation of electric and magnetic fields. These results indicate that inclusion of Zr in Nb$_3$Sn sputtered coating will improve the material quality and might help to reduce the overall RF power dissipation. Secondly, we observed that increasing Zr concentration from 0 to 2.4% substantially improves both superconducting transition temperature (Tc) and upper critical magnetic field (Hc2). However, on further increasing the Zr concentration to 24%, we noticed a small decrement in the Hc2 value. These results infer that the increase in Zr concentration up to an optimal concentration will be beneficial to enhance the superconducting properties. Increase in Tc promises lesser RF losses and improvement in accelerating gradient, whereas the increase in Hc2 suggests more efficient flux pinning which could give rise to high quality factors in presence of multi-Tesla magnetic field. Additionally, we also observed that increasing Zr concentration possibly prevents the oxygen diffusion and leads to thinner formation of primary surface oxide (Nb$_2$O$_5$ and SnO). This study gives a route to tune Zr fraction in Nb3Sn to modify the physical properties that control the high field performance of Nb3Sn RF cavities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Helicon Plasma Injector and Ion Cyclotron Acceleration Development in the VASIMR Experiment

In the Variable Specific Impulse Magnetoplasma Rocket (VASIMR) radio frequency (rf) waves both produce the plasma and then accelerate the ions. The plasma production is done by action of helicon waves. These waves are circular polarized waves in the direction of the electron gyromotion. The ion acceleration is performed by ion cyclotron resonant frequency (ICRF) acceleration. The Advanced Space Propulsion Laboratory (ASPL) is actively developing efficient helicon plasma production and ICRF acceleration. The VASIMR experimental device at the ASPL is called VX-10. It is configured to demonstrate the plasma production and acceleration at the 10kW level to support a space flight demonstration design. The VX-10 consists of three electromagnets integrated into a vacuum chamber that produce magnetic fields up to 0.5 Tesla. Magnetic field shaping is achieved by independent magnet current control and placement of the magnets. We have generated both helium and hydrogen high density (>10(exp 18) cu m) discharges with the helicon source. ICRF experiments are underway. This paper describes the VX-10 device, presents recent results and discusses future plans.

Squire, Jared P.↗

An X-Band Ultra-High Gradient Photoinjector

High brightness beams appealing for XFELs and UEM essentially imply a high current and a low emittance. To obtain such beams we propose to raise the accelerating voltage in the gun mitigating repealing Coulomb forces. An ultra-high gradient is achieved utilizing a short-pulse technology. We have designed a room temperature X-band 1,5 cell gun that is able to inject 4 MeV, 100 pC bunches with as low as 0.15 mcm normalized transverse emittance. The gun is operated with as high gradients as 400 MV/m and fed by 200 MW, 10 ns RF pulses generated with Argonne Wakefield Accelerator (AWA) power extractor. We report results of low RF power tests, laser alignment test results, and successful gun conditioning results carried out at nominal RF power.

43 PARTICLE ACCELERATORS↗

On the Phase Grouping Mechanism for a Magnetron Coherent Oscillation

CW magnetrons, developed for industrial heaters, but driven by an injection-locking signal were suggested to power Superconducting RF (SRF) cavities due to higher efficiency and lower cost of generated RF power per Watt than traditionally used RF sources (klystrons, IOTs, solid-state amplifiers). When the magnetrons are intended to feed Room Temperature (RT) cavities, the injected phase or frequency locking signal may provide required phase or frequency stability of the accelerating field. However, when the magnetron RF sources are intended to feed high Q-factor SRF cavities, the sources must be controlled in phase and power in a wide bandwidth to compensate parasitic phase and amplitude modulations caused by microphonics. In dependence on parameters of magnetron and the injection-locking signal one can choose regime most suitable for feeding SRF cavities, enabling magnetron almost coherent oscillation at the wide bandwidth of control. A novel approach considering magnetrons as quasi-coherent or coherent RF generators enables choosing the tube parameters and operation most suitable for various SRF accelerators.

43 PARTICLE ACCELERATORS↗

Rotating field mass and velocity analyzer

A rotating field mass and velocity analyzer having a cell with four walls, time dependent RF potentials that are applied to each wall, and a detector. The time dependent RF potentials create an RF field in the cell which effectively rotates within the cell. An ion beam is accelerated into the cell and the rotating RF field disperses the incident ion beam according to the mass-to-charge (m/e) ratio and velocity distribution present in the ion beam. The ions of the beam either collide with the ion detector or deflect away from the ion detector, depending on the m/e, RF amplitude, and RF frequency. The detector counts the incident ions to determine the m/e and velocity distribution in the ion beam.