Search NASA⌕ Search

SEARCH · Search NASA

Results for “RUBY LASER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

179 records · Page 10

Nonradiative relaxation in tunable solid state laser crystals

The characteristics of nonradiative transitions between the 4T2 and 2E excited states of trivalent-chromium-ion-activated ruby (containing 0.04 percent Cr2O3 by weight) and alexandrite (containing 0.4 at. percent chromium ion) laser crystals were studied using the technique described by Gayen et al. (1985). In this technique, a 527-nm pulse excites the 4T2 band of the Cr(3+), and the subsequent population kinetics among excited states is monitored by an IR picosecond probe pulse as a function of pump-probe delay. In ruby, a resolution-limited sharp rise in the excited state population was followed by a long-lifetime decay, leading to an upper limit of 7 ps for the 4T2-state nonradiative lifetime. In alexandrite, a longer rise time was followed by a multicomponent decay. A theoretical model is proposed for explaining the induced absorption and the transition dynamics observed in these crystals.

Gayen, S. K.↗

Analysis of differential absorption lidar from the Space Shuttle

A parametric analysis of the Shuttle-borne differential absorption lidar concept for the measurement of atmospheric trace constituent profiles in the nadir viewing mode is presented. The criterion of an optimum constituent optical depth is developed and applied to generate estimates of range resolved measurement errors. These errors emphasize the fundamental limitations for establishing the feasibility of range-resolved differential absorption lidar measurements from Shuttle. With current lidar system technology, atmospheric backscatter density profiles may be adequately determined up to about 60-km altitude at the doubled-ruby wavelength, 3472 A, for a 1-J/pulse laser and a 1-sq m receiver. Potential range-resolved measurements of stratospheric and mesospheric trace constituents by differential absorption from Shuttle altitudes are limited to H2O, CH4, N2O, O3, and CO, species which can be more easily measured by passive limb viewing techniques. Range-resolved water vapor data for the lower troposphere may be obtained with accuracies which would be competitive with those from passive sensors.

Remsberg, E. E.↗

Nd:YAG and ruby based lidar systems for remote sensing of atmospheric aerosols

The application of solid-state lasers to the study of stratospheric and tropospheric aerosols is analyzed. A 48-inch mobile lidar which operates in the 0.6943, 1.06, 0.3472, and 0.5300 micron ranges is utilized to monitor the stratosphere. The detectors of the system consist of photomultipliers, and the dual-channel, computer-based data-acquisition-system which provides on-line plotting of scattering ratio profiles. The components of the 14-inch aperture, dual-wavelength airborne lidar system that operates with ruby and Nd:YAG transmitters are described. An 8-inch, down-looking airborne lidar with silicon diode or photomultiplier detectors was developed. The capabilities of the system alone and when combined with the 14-inch lidar are discussed. Examples of the data provided by the three lidar systems are presented, revealing the reliability and operational efficiency of the systems.

Fuller, W. H., Jr.↗

Coherent lidar technology for global wind profiling

Current lidar systems are proven sensors for atmospheric wind measurement. Ground-based and airborne continuous wave and pulsed CO2 systems were developed and applied to several wind measuring applications. Analytical and hardware feasibility studies indicte the feasibility of measuring the global wind field from a space splatform. A Global Backscater Experiment is planned by NASA to develop a global model of aerosol backscatter using a CO2 laser. Ground-based aerosol backscatter profiles will also be obtained using a ruby and a pulsed CO2 lidar.

Huffaker, R. M.↗

Vapor phase deposition of alumina on interior surfaces of tritium storage containers

Efficient tritium management and containment are critical challenges for nuclear fusion. To mitigate issues related to permeation into structural materials and isotopic exchange with protium, permeation barriers must be applied to the nonplanar internal surfaces of tritium handling components. In this study, we developed an atomic layer deposition (ALD) system to deposit films on canisters used to store and transport tritium. Growth conditions for deposition of Al 2 O 3 were mapped spatially along the length of a canister using silicon witness samples characterized by ellipsometry, atomic force microscopy, and x-ray reflectivity (XRR). We identified ALD process windows for growth at temperatures between 100 and 140 °C. Furthermore, we compared films grown on our Si witness samples to those grown on polished stainless steel 316 (SS316). X-ray photoelectron spectroscopy indicates two distinct chemical states for the alumina, while XRR confirms that the overall growth rate is similar to the 1.1 Å/cycle that we observed on the Si witness samples.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

UV lidar measurements of the stratospheric aerosol layer and comparison with other optical data

After the violent volcanic eruptions of El Chichon in Mexico (17.33 deg. N, 93.20 deg. W) in late March and early April 1982, enhanced stratospheric aerosols have been monitored by ruby (lasing wavelength lambda=694.3 nm) or Nd:YAG lidars (lambda=1064 or 532 nm). By these lidars, visible or near-infrared optical informations of stratospheric aerosols and their space-time variations can be obtained. It is usually difficult to measure the background level of stratospheric aerosols by an ultraviolet (UV) lidar, since Rayleigh scattering prevails over Mie scattering in the stratosphere. However, after the large volcanic eruptions, UV lidar measurements of stratospheric aerosols are possible. In order to obtain UV optical properties of stratospheric aerosols, measurements have been made at Fukuoka (33.65 deg. N, 130.35 deg. E) by a p-terphenyl dye laser at a wavelength of 340.5 nm. Observational results during October 1982, through May 1983, are shown and are compared with the results obtained by a ruby lidar at Tsukuba (36.05 deg. N, 140.13 deg. E).

Uchino, O.↗

Improved solution of the lidar equation utilizing particle counter measurements

The extraction of particle backscattering from incoherent lidar measurements poses some problems. In the case of measurements of the stratospheric aerosol layer the solution of the lidar equation is based on two assumptions which are necessary to normalize the measured signal and to correct it with the two-way transmission of the laser pulse. Normalization and transmission are tackled by adding the information contained in aerosol particle counter measurements of the University of Wyoming to the ruby lidar measurements at Garmisch-Partenkirchen. Calculated backscattering from height levels above 25 km for the El Chichon period will be compared with lidar measurements and necessary corrections. The calculated backscatter-to-extinction ratios are compared to those, which were derived from a comparison of published extinction values to measured lidar backscattering at Garmisch. These ratios were used to calculate the Garmisch lidar returns. For the period 4 to 12 months after the El Chichon eruption a backscater-to-extinction ratio of 0.026 1/sr was applied with smaller values before and after that time.

Jaeger, H.↗

Eocene-Oligocene Metamorphism, Fluid Flow and Deformation in the Ruby Mountains-East Humboldt Range Metamorphic Core Complex

Metamorphic core complexes are ubiquitous in collapsed orogens globally and play a primary role in crustal exhumation. Here, we investigate the metamorphic history of the Ruby Mountains-East Humboldt Range metamorphic core complex, Nevada, using petrochronology to understand how magmatism, metamorphism and deformation interact to modulate crustal rheology, and the timing of exhumation within the Sevier orogenic belt. Field study, microstructural analysis, thermobarometry and laser ablation split-stream monazite, titanite and allanite petrochronology of the mylonitic footwall were integrated to elucidate the pressure-temperature-time (P-T-t) evolution. Major-, trace-element and quartz-in-garnet thermobarometry show peak metamorphism occurred at 5.5–6 kbar and 600–650°C across the study area. Monazite and titanite U-(Th)-Pb petrochronology constrain this episode of metamorphism to 88–81 Ma with the structurally deepest samples yielding dates down to ca. 71 Ma. The preservation of peak metamorphic mineral assemblages indicates these rocks remained at near-peak temperature conditions into the Cenozoic. Cenozoic metamorphism occurred during a punctuated episode contemporaneous with the Great Basin ignimbrite flare up. All samples show a distinct 39–37 Ma population of monazite, titanite and allanite dates that correlate with the emplacement of quartz diorite and gabbro intrusions throughout the footwall. Accessory phases contain zoning textures in backscattered electron images that are consistent with fluid-mediated dissolution-reprecipitation reactions. The U-(Th)-Pb analyses from these zones yield 39–27 Ma dates interpreted as the timing of fluid flow. The results of this study elucidate the integrated importance of magmatism, melting and fluid flow in driving the coupled evolution of Late Cretaceous metamorphism within the Sevier hinterland and the subsequent Cenozoic metamorphic core complex development that exhumed the middle crust.

58 GEOSCIENCES↗

Multiple scattering depolarization in marine stratus clouds: Lidar experiments

The depolarization of ruby lidar backscattering caused by multiple scattering in marine stratus clouds was examined systematically from a field site on the southern California coast. Investigated were the effects on the linear depolarization (delta) of lidar receiver field of view (FOV), elevation angle and laser beam pointing errors. An approximately linear increase in maximum delta values was observed with increasing receiver FOV, and the importance of accurate transmitter/receiver beam alignment was demonstrated during experiments in which the laser axis was deliberately misaligned. An elevation angle dependence to the delta values was observed as a consequence of the natural vertical inhomogeneity of water cloud content above the cloud base. Time histories of the depolarization characteristics of dissipating stratus clouds revealed significant spatial and temporal variability in delta values attributed to cloud composition variations. Employing a 1 mrad transmitter FOV, maximum delta values of 0.21 nd 0.33 were observed with 1 and 3 mrad receiver FOVs, respectively, from the low stratus clouds. The fundamental causes and effects on the lidar equation of multiple scattering are also discussed.

Sassen, K.↗

Energy Connector [SWR-26-014]

The Energy Connector is a web-based software application that is designed to facilitate energy bill savings for low-income households through streamlined community solar subscriptions. By using the Connector, Developers and Subscription Managers can save money on acquisition costs and streamline enrollment without having to perform additional income verification.

Rivard, Tim [National Laboratory of the Rockies (N↗

Ophthalmic Diagnostics Using a New Dynamic Light Scattering Fiber Optic Probe

A new fiber optic probe is developed to study different parts of the eye. The probe positioned in front of an eye, delivers a low power light from a laser diode into the eye and guides the light which is back scattered by different components (aqueous humor, lens, and vitreous humor) of the eye through a receiving optical fiber to a photo detector. The probe provides rapid determination of macromolecular diffusivities and their respective size distributions in the eye lens and the gel-like material in the vitreous humor. We report alpha-crystalline size distributions, as a function of penetration depth, inside the lens and hyaluronic acid molecular size distribution in the vitreous body. In a clinical setting, the probe can be mounted on a slit-lamp apparatus simply by using a H-ruby lens holder. The capability of detecting cataracts, both nuclear and peripheral, in their early stages of formation, in a non invasive and quantitative fashion, has the potential in patient monitoring and in developing and testing new drugs or diet therapies to 'dissolve' or slow down the cataract formation before surgery is necessary. The ability to detect biochemical and macromolecular changes in the vitreous structure can be very useful in identifying certain diseases of the posterior chamber, e.g., posterior vitreous detachment.

Ansari, Rafat R.↗

Melting of troilite at high pressure in a diamond cell by laser heating

A system for measuring melting temperatures at high pressures is described. The sample is heated with radiation from a YAG laser. The beam is reflected downward through a microscope objective, through the upper diamond anvil, and focused onto the sample. Hense, intense heating is produced only at the sample and not within the diamond anvils. A vidicon system is used to observe the sample during heating. Incandescent light from the heated sample passes back through the objective lens into a grating spectrometer. The spectrum of the incandescent light is received by the photodiode array and stored in the multichannel analyzer. These data can then be transferred to floppy disk for analysis. A curve fitting program is used to compare the spectra with standard blackbody curves and to determine the temperature. Pressure is measured by the ruby fluorescence method. The system was used to study the melting behavior of natural troilite (FeS).

Bassett, William A.↗

Analysis of streaked images of x-ray self-emission in laser-driven spherical implosions

Imaging of x-ray self-emission provides a powerful in situ measurement of the spatial and temporal evolution of high-energy-density plasmas. However, interpretation of these measurements requires detailed understanding of the data-generating process. This work presents a case study in the interpretation of x-ray self-emission data for the specific application of streaked one-dimensional slit imaging of spherical laser-driven implosions. A comprehensive generative model of the streaked slit-imaging diagnostic is developed including detailed treatments of the radiation transfer, photometrics, and photostatistics associated with the measurement. The model is used to generate realistic synthetic streaked images and to analyze experimental streaked images to extract important physical quantities of interest. An example analysis of streaked images from implosion experiments on the OMEGA laser is presented, where the model developed in this work is used to constrain the trajectory and peak velocity of the implosion using Bayesian inference.

Bayesian inference↗

X-ray phase-contrast imaging of strong shocks on OMEGA EP

The ongoing improvement in laser technology and target fabrication is opening new possibilities for diagnostic development. An example is x-ray phase-contrast imaging (XPCI), which serves as an advanced x-ray imaging diagnostic in laser-driven experiments. In this work, we present the results of the XPCI platform that was developed at the OMEGA EP Laser-Facility to study multi-Mbar single and double shocks produced using a kilojoule laser driver. Two-dimensional radiation-hydrodynamic simulations agree well with the shock progression and the spherical curvature of the shock fronts. It is demonstrated that XPCI is an excellent method to determine with high accuracy the front position of a trailing shock wave propagating through an expanding CH plasma that was heated by a precursor Mbar shock wave. Furthermore, the interaction between the rarefaction wave and the shock wave results in a clear signature in the radiograph that is well reproduced by radiation-hydrodynamic simulations.

47 OTHER INSTRUMENTATION↗

Design and Calibration of a Raman Spectrometer for use in a Laser Spectroscopy Instrument Intended to Analyze Martian Surface and Atmospheric Characteristics for NASA

This project's goal is the design of a Raman spectroscopy instrument to be utilized by NASA in an integrated spectroscopy strategy that will include Laser-Induced Breakdown Spectroscopy (LIBS) and Laser-Induced Florescence Spectroscopy (LIFS) for molecule and element identification on Mars Europa, and various asteroids. The instrument is to be down scaled from a dedicated rover mounted instrument into a compact unit with the same capabilities and accuracy as the larger instrument. The focus for this design is a spectrometer that utilizes Raman spectroscopy. The spectrometer has a calculated range of 218 nm wavelength spectrum with a resolution of 1.23 nm. To filter out the laser source wavelength of 532 nm the spectrometer design utilizes a 532 nm wavelength dichroic mirror and a 532 nm wavelength notch filter. The remaining scatter signal is concentrated by a 20 x microscopic objective through a 25-micron vertical slit into a 5mm diameter, 1cm focal length double concave focusing lens. The light is then diffracted by a 1600 Lines per Millimeter (L/mm) dual holographic transmission grating. This spectrum signal is captured by a 1-inch diameter double convex 3 cm focal length capture lens. An Intensified Charge Couple Device (ICCD) is placed within the initial focal cone of the capture lens and the Raman signal captured is to be analyzed through spectroscopy imaging software. This combination allows for accurate Raman spectroscopy to be achieved. The components for the spectrometer have been bench tested in a series of prototype developments based on theoretical calculations, alignment, and scaling strategies. The mounting platform is 2.5 cm wide by 8.8 cm long by 7 cm height. This platform has been tested and calibrated with various sources such as a neon light source and ruby crystal. This platform is intended to be enclosed in a ruggedized enclosure for mounting on a rover platform. The size and functionality of the Raman spectrometer allows for the rover to carry other mission critical devices. This project will be continued at NASA until the requirements are met for the expected initial 2020 launch date.

Lucas, John F.↗