Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Damage Calculation Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

SU-E-T-356: Efficient Segmentation of Flattening Filter Free Photon Beamsfor 3D-Conformal SBRT Treatment Planning

Purpose: It has been argued that a 3D-conformal technique (3DCRT) is suitable for SBRT due to its simplicity for non-coplanar planning and delivery. It has also been hypothesized that a high dose delivered in a short time can enhance indirect cell death due to vascular damage as well as limiting intrafraction motion. Flattening Filter Free (FFF) photon beams are ideal for high dose rate treatment but their conical profiles are not ideal for 3DCRT. The purpose of our work is to present a method to efficiently segment an FFF beam for standard 3DCRT planning. Methods: A 10×10 cm Varian True Beam 6X FFF beam profile was analyzed using segmentation theory to determine the optimum segmentation intensity required to create an 8 cm uniform dose profile. Two segments were automatically created in sequence with a Varian Eclipse treatment planning system by converting isodoses corresponding to the calculated segmentation intensity to contours and applying the “fit and shield” tool. All segments were then added to the FFF beam to create a single merged field. Field blocking can be incorporated but was not used for clarity. Results: Calculation of the segmentation intensity using an algorithm originally proposed by Xia and Verhey indicated that each segment should extend to the 92% isodose. The original FFF beam with 100% at the isocenter at a depth of 10 cm was reduced to 80% at 4cm from the isocenter; the segmented beam had +/−2.5 % uniformity up to 4.4cm from the isocenter. An additional benefit of our method is a 50% decrease in the 80%-20% penumbra of 0.6cm compared to 1.2cm in the original FFF beam. Conclusion: Creation of two optimum segments can flatten a FFF beam and also reduce its penumbra for clinical 3DCRT SBRT treatment.

60 APPLIED LIFE SCIENCES↗

Annealing of focused ion beam damage in gold microcrystals: an in situ Bragg coherent X-ray diffraction imaging study

Focused ion beam (FIB) techniques are commonly used to machine, analyse and image materials at the micro- and nanoscale. However, FIB modifies the integrity of the sample by creating defects that cause lattice distortions. Methods have been developed to reduce FIB-induced strain; however, these protocols need to be evaluated for their effectiveness. Here, non-destructive Bragg coherent X-ray diffraction imaging is used to study the in situ annealing of FIB-milled gold microcrystals. Two non-collinear reflections are simultaneously measured for two different crystals during a single annealing cycle, demonstrating the ability to reliably track the location of multiple Bragg peaks during thermal annealing. The thermal lattice expansion of each crystal is used to calculate the local temperature. This is compared with thermocouple readings, which are shown to be substantially affected by thermal resistance. To evaluate the annealing process, each reflection is analysed by considering facet area evolution, cross-correlation maps of the displacement field and binarized morphology, and average strain plots. The crystal's strain and morphology evolve with increasing temperature, which is likely to be caused by the diffusion of gallium in gold below ~280°C and the self-diffusion of gold above ~280°C. The majority of FIB-induced strains are removed by 380–410°C, depending on which reflection is being considered. These observations highlight the importance of measuring multiple reflections to unambiguously interpret material behaviour.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Auger spectrum of a water molecule after single and double core ionization

The high intensity of free electron lasers opens up the possibility to perform single-shot molecule scattering experiments. However, even for small molecules, radiation damage induced by absorption of high intense x-ray radiation is not yet fully understood. One of the striking effects which occurs under intense x-ray illumination is the creation of double core ionized molecules in considerable quantity. To provide insight into this process, we have studied the dynamics of water molecules in single and double core ionized states by means of electronic transition rate calculations and ab initio molecular dynamics (MD) simulations. From the MD trajectories, photoionization and Auger transition rates were computed based on electronic continuum wavefunctions obtained by explicit integration of the coupled radial Schroedinger equations. These rates served to solve the master equations for the populations of the relevant electronic states. To account for the nuclear dynamics during the core hole lifetime, the calculated electron emission spectra for different molecular geometries were incoherently accumulated according to the obtained time-dependent populations, thus neglecting possible interference effects between different decay pathways. We find that, in contrast to the single core ionized water molecule, the nuclear dynamics for the double core ionized water molecule during the core hole lifetime leaves a clear fingerprint in the resulting electron emission spectra. The lifetime of the double core ionized water was found to be significantly shorter than half of the single core hole lifetime.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Metallurgical aspects influencing the resistance to steam oxidation and fracture toughness of select advanced replacement alloys for LWR core internals

Life extension of the existing nuclear reactors imposes accumulated damages, such as higher fluences and longer period of corrosion, to structural materials, which would result in significant challenges to the traditional reactor materials such as type 304 and 316 stainless steels. Advanced alloys with superior radiation resistance will increase safety margins, design flexibility, and economics for not only the life extension of the existing fleet but also new builds with advanced reactor designs. The Electric Power Research Institute (EPRI) teamed up with Department of Energy (DOE) to initiate the Advanced Radiation Resistant Materials (ARRM) program, aiming to develop and test degradation resistant alloys from current commercial alloy specifications by 2021 to a new advanced alloy with superior degradation resistance in light water reactor (LWR)-relevant environments by 2024. Corrosion resistance in water environment is one of the fundamental properties required for LWR core internal materials. High-temperature steam oxidation tests are not only an accelerated life testing method to uncover potential failure modes in a short period of time, but also an approach to evaluate materials’ resistance to accidental scenarios. Coupons, prepared from fourteen candidate alloys that were selected under the ARRM program, were exposed to 1 bar full steam with ~10 part-per-billion oxygen content at 600 and 650°C for up to 5,000 h, which were weighed at 500-h intervals. Ni-base superalloys are an important class of alloys for reactor applications. Alloys 690, 725, and X- 750 were three of the selected Ni-base superalloys exposed to the steam tests. This report summarizes the metallurgical aspects, such as alloy thermodynamics and the nature of the oxides and the diffusivities of primary elements, and their effects on oxidation behavior of the three alloys. In addition to monitoring mass change, microstructures of the 5000h-exposed samples of alloys 690, 725, and X-750 were characterized using scanning and transmission electron microscopy and energy dispersive x-ray spectroscopy. Together with thermodynamic calculations, the scale constitution and its exfoliation behavior were discussed. Based on experimental and theoretical values, a new model was proposed to quantitatively estimate the metal thickness loss of the alloys. Alloy X-750 was found to have the best resistance to steam oxidation with the least metal thickness loss (<1 μm), which were slightly superior to alloy 690. Alloy 725 exhibited the worst resistance to steam oxidation with the greatest metal thickness loss, e.g., ~2.5 μm at 650°C, which is nearly three times of the metal thickness losses of alloys 690 and X-750 at 650°C. The greatest metal thickness loss of alloy 725 might be attributable to its high Mo content. Photos of the fracture toughness tested samples of eight alloys are presented, which will be correlated with their fracture toughness results and planned tensile test results to select representative alloy samples for detailed microstructural characterization to reveal their microstructure and properties relationships.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Neutron scattering measurement of water content and chemical composition of alkali-glass powder reacted gel

Highlights: • Water absorption ability of alkali-glass powder reacted gel was largely reduced comparing other reported alkali-silica gels. • Both SAXS and SANS results showed similar internal structures of samples prepared with different H2O:D2O mixing ratios. • Neutron scattering method was developed to non-destructively determine gel water content and mass density of reacted gels. • Neutron scattering methods (based on scattering length density) on gel water content was validated with TGA measurement. - Abstract: Recent studies demonstrated that the added glass powder with high-alumina content could significantly reduce Alkali-Silica Reaction (ASR) damage in cement concrete. This paper aims to investigate the gel water content, chemical composition and expansion behavior of the alkali-glass powder reacted gel by using neutron scattering and other characterization techniques. Three types of samples were prepared with glass powder, sodium oxide and deuteroxide/hydrogen water with different molar ratios. The swelling potential of this alkali-glass powder reacted gel was much lower than that of the reported alkali-silica reacted gel. The gel water content and chemical compositions were characterized with small-angle neutron scattering (SANS) technique, supported by small-angle X-ray scattering (SAXS), prompt-gamma ray neutron activation analysis (PGAA) measurement. The SAXS test results showed the close scattering intensities, and thus similar internal microstructures among these samples. The elemental molar ratios of gels were obtained from the PGAA test results. Then the gel water molar ratio and mass density were determined by neutron scattering contrast calculation. The determined gel water content from neutron scattering analysis was validated with zero contrast analysis and TGA experimental measurement. Overall, this paper demonstrated the feasibility of using SANS technique to determine the water content of alkali-glass powder reacted gel.

36 MATERIALS SCIENCE↗

NSRD-16: Computational Capability to Substantiate DOE-HDBk-3010 Data

Safety basis analysts throughout the U.S. Department of Energy (DOE) complex rely heavily on the information provided in the DOE Handbook, DOE-HDBK-3010, Airborne Release Fractions/Rates and Respirable Fractions for Nonreactor Nuclear Facilities, to determine radionuclide source terms from postulated accident scenarios. In calculating source terms, analysts tend to use the DOE Handbook's bounding values on airborne release fractions (ARFs) and respirable fractions (RFs) for various categories of insults (representing potential accident release categories). This is typically due to both time constraints and the avoidance of regulatory critique. Unfortunately, these bounding ARFs/RFs represent extremely conservative values. Moreover, they were derived from very limited small-scale bench/laboratory experiments and/or from engineered judgment. Thus, the basis for the data may not be representative of the actual unique accident conditions and configurations being evaluated. The goal of this research is to develop a more accurate and defensible method to determine bounding values for the DOE Handbook using state-of-art multi-physics-based computer codes. This enables us to better understand the fundamental physics and phenomena associated with the types of accidents in the handbook. In this fourth year, we improved existing computational capabilities to better model fragmentation situations to capture small fragments during an impact accident. In addition, we have provided additional new information for various sections of Chapters 4 and 5 of the Handbook on free fall powders and impacts of solids, and have provided the damage ratio simulations for containers (7A drum and standard waste box) for various drops and impact scenarios. Thus, this work provides a low-cost method to establish physics-justified safety bounds by considering specific geometries and conditions that may not have been previously measured and/or are too costly to perform during an experiment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Coupled effect of Cr and Al on interactions between a prismatic interstitial dislocation loop and an edge dislocation line in Fe-Cr-Al alloy

Segregation of alloying elements to a prismatic dislocation loop under irradiation is an important phenomenon in understanding the role of loops in radiation effects in alloys. In this work, various segregation sequences of Cr and Al atoms to a $\langle$100$\rangle$ and a 1/2 $\langle$111$\rangle$ prismatic dislocation loop in a Fe-Cr-Al alloy are explored using molecular dynamics method and ab initio energy calculation. Here, the results reveal that Cr can readily segregate to the loops while Al atoms cannot by themselves, but the segregated Cr atoms are able to promote Al segregation at the loops, defined as a coupled segregation of Cr and Al. After interacting with Cr and Al, a previously mobile 1/2 $\langle$111$\rangle$ loop becomes sessile. Al segregation through the coupled segregation process can further affect the pinning behavior of a dislocation loop to an edge dislocation motion. By varying the Al fraction in the segregated solutes, a nonlinear dependence of the pinning effect on dislocation motion is determined. At lower fractions, the pinning strength increases with the increasing Al fraction until Al fraction reaches a critical value of about 19%, above which the pinning strength decreases with further increase of Al fraction. All these results suggest that, in addition to the effect of Al on the surface resistance to oxidation, Al effect on the dislocation loop behavior is important to optimize the composition of Fe-Cr-Al alloys for their applications in accident tolerant fuel concepts.

36 MATERIALS SCIENCE↗

SU-E-T-141: Effect of a Single Gold Nanoparticle with Different Sizes Inside a Small Water Phantom

Purpose: This study is to investigate the effects of the gold nanoparticles (GNP), a series of micrometre scale simulations have been constructed with Geant4 to track particles and simulate the effects of those particles as they pass through water phantom. Methods: The simulations were used to calculate the number of secondary electrons which are emitted from the particle tracks and the amount of energy which is deposited in the cell tissue. More electrons means that more water molecules can undergo hydrolysis and create potentially dangerous free radical molecules, therefore breaking up DNA and killing off cells or causing damaging mutations. Results: For the 20nm GNP, all three proton energies saw a small increase of electrons above the control, while the X-rays nearly tripled the number of electrons in the phantom. For the 50 nm GNP, the 3 and 2 MeV protons saw a small increase again, however the 1 MeV protons saw a decrease in electrons, the X-rays saw a large increase of nearly 4 times the number of electrons. For the 110nm GNP, all three proton energies saw a decrease in the total number of electrons in the phantom, while the X-rays saw an increase of 8 times as many electrons. Conclusion: From the range of GNP sizes used, it was found that the X-rays have a larger dose enhancement effect as the GNP size increases, the relation between electron emissions and GNP size was linear. This is because the majority of the dose from the X-rays is delivered to the cell tissue through the initial high energy secondary electrons, any dose lost from the Augerelectrons being trapped inside the GNP volume is small compared to the dose that escapes with the high energy electrons.

60 APPLIED LIFE SCIENCES↗

SU-E-T-47: Application of the Repair-Misrepair-Fixation RBE Model to Describe the Results of High Resolution Proton Irradiation Cell Survival Experiments

Purpose: To develop a system to rapidly and accurately calculate RBE with the repair-misrepair-fixation (RMF) model for proton therapy data sets and to evaluate its effectiveness in modeling RBE for cell survival experiments performed with the H460 cell line for a range of proton LET. Methods: A system for using the Monte Carlo Damage Simulation (MCDS) software with high performance computing was developed. Input for the MCDS software for a range of proton energies in increments of 0.1 MeV was generated and simulated. The output data were then used to determine doseaveraged quantities for the RMF model based on equivalently binned proton energy spectra. The method was applied to calculate RBE at 50% survival for experimental cell survival data. Experimental data were obtained using a system which allowed for the accumulation of cell survival data at known values of dose-averaged proton LETs at a range of doses. RBE was calculated based directly on a Cs-137 reference experiment and, additionally, according to fitted values of the θ and κ terms of the RMF model. Results: Dose-averaged RMF model quantities were calculated using the HPC system. Compared to experimental RBE determined using a Cs-137 irradiation as a reference, the RBE from the model differed by at most 49%. RBE based on the fitted values of θ and κ differed by at most 18% for the highest LET. Conclusion: A system for rapidly generating data necessary to calculate RBE with the RMF model has been developed. For the H460 cell line, the RMF model could not reproduce the experimentally determined RBE based solely on the photon reference data. Fitting of the θ and κ terms of the RMF model indicates that their values increase for proton LET exceeding approximately 10 keV/µm. NIH Program Project Grant P01CA021239.

60 APPLIED LIFE SCIENCES↗

A modified hypoxia-based TCP model to investigate the clinical outcome of stereotactic hypofractionated regimes for early stage non-small-cell lung cancer (NSCLC)

Purpose: Stereotactic body radiotherapy (SBRT) has been applied to lung tumors at different stages and sizes with good local tumor control (LC) rates. The linear quadratic model (LQM), in its basic formulation, does not seem to be appropriate to describe the response to radiotherapy for clinical trials, based on a few fractions. Thus, the main aim of this work was to develop a model, which takes into account the hypoxic cells and their reoxygenation. Methods: A parameter named B has been introduced in a modified tumor control probability (TCP) from LQM and linear-quadratic-linear model (LQLM), and represents the fraction of hypoxic cells that survive and become oxygenated after each irradiation. Based on published trials evaluating LC at 3 yr (LC3), values of B were obtained by maximum likelihood minimization between predicted TCP and clinical LC3. Two oxygen enhancement ratio (OER) parameter sets (1 and 2) from literature have been adopted to calculate the B-factors. Initial hypoxic cell fractions ({eta}{sub h}) from 0.05 to 0.50 were assumed. Log-likelihood (L) and Akaike information criterion (AIC) were determined in an independent clinical validation dataset. Results: The B-values of modified TCPs spanned the whole interval from 0 to 1, depending on the fractionation scheme (number of fractions and dose/fraction), showing a maximum (close to 1) at doses/fraction of 8-12 Gy. The B-values calculated using the OER parameter set 1 exhibited a smoother falloff than set 2. An analytical expression was derived to describe the B-value's dependence on the fractionation scheme. The R{sup 2}-adjusted values varied from 0.63 to 0.67 for LQ models and OER set 1 and from 0.75 to 0.78 for LQ model and OER set 2. Lower values of R{sup 2}-adjusted were found for LQLM and both OER sets. L and AIC, calculated using a fraction of {eta}{sub h} = 0.15 and the B-value from the authors analytical expression were higher than for other {eta}{sub h}-values, irrespective of model or OER set. Conclusions: The authors model allows to predict the clinical outcome associated with SBRT treatment, taking into account both direct killing and indirect vasculature or stromal damage.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radioactive Waste Water Treatment for Fukushima Daiichi Nuclear Power Plant - 16081

The Great East Japan Earthquake of 11 March 2011 caused serious damage to the Fukushima Daiichi Nuclear Power Station (NPS) of the Tokyo Electric Power Company, Inc.. Toshiba and Shaw/AVANTech installed a Simplified Active Water Retrieve and Recovery System (SARRY{sup TM}) to remove radioactive cesium (Cs) from the contaminated water. Toshiba, in partnership with EnergySolutions, also developed and installed the Multi Radionuclide Removal System (MRRSTM), which can remove radioactive nuclides being treated, except tritium, to a level less than the concentration limit in water. As contaminated water treatment has progressed, the composition of the contaminated water has changed. Both salinity and radioactive Cs concentration in the contaminated water have been decreasing. Thus, a new adsorbent that is suitable for the present water chemistry conditions is required. In order to provide an appropriate contaminated-water treatment system, Toshiba has been examining the removal of not only radioactive Cs but also radioactive strontium (Sr) by SARRY{sup TM}. SARRY{sup TM} has been operated for removing Cs by using a Cs adsorbent. Instead of a Cs adsorbent, a new media that has high selectivity for both Cs and Sr should be installed. This paper describes the results obtained when using the newly developed adsorbent for removing Cs and Sr at once. As the Cs and Sr adsorbent, we have selected crystalline silico-titanate (CST). The distribution coefficient (K{sub d}) of CST was determined by the batch method. The lifetime of the adsorbent was evaluated by a column examination. The selected CST had a K{sub d} value of over 10{sup 4} ml/g for both Cs and Sr. The highest-selectivity CST had a lifetime (defined as the period for the outlet concentration to decrease to one tenth of the inlet level) of more than 125000 BV (bed volume) for Cs and more than 18000 BV for Sr, when the test was conducted at 10 BV/h. Calculation code was also developed for estimating the relation between the BV and the decontamination factor (DF) using an adsorption rate model for diffusion and adsorption. The calculation results of the Cs and Sr adsorption behavior agreed well with the experimental results. To evaluate the replacement cycle of adsorption tower in actual equipment, the radiation exposure during the replacement operation and the required Cs and Sr removal performance were used as limiting conditions for the estimation. The results of the evaluation showed that the selected CST has sufficient performance for practical usage. Based on this finding, Toshiba proposed loading the CST in SARRY{sup TM}, and SARRY{sup TM} loaded with this CST started removing Cs and Sr in December 2014 resulting in decreased contaminated water. It has been continuously working since then. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Green synthesis and characterization of nontoxic L-methionine capped silver and gold nanoparticles

The simple green method for synthesis of stable L-Methionine (L-Met) capped silver (Ag@LM NPs) and gold (Au@LM NPs) nanoparticles (NPs) without adding any additional reduction agent or stabilizer was developed. Colloidal dispersions were characterized by UV–Vis spectrophotometry. The size and spherical shape of NPs were evaluated by transmission electron microscopy. Their surface covering was confirmed by atomic force microscopy, Fourier transform infrared spectroscopy, dynamic light scattering, and zeta potential measurements. Density functional theory calculations pointed that the preferential adsorption mode of L-Met on both Ag and Au surfaces was a vertical binding geometry via –NH2 group, while horizontal binding mode via [sbnd]S[sbnd] and –NH2 groups is also possible. The genotoxicity (evaluated by the micronucleus assay) of NPs, as well as their effects on some oxidative stress parameters (catalase activity, malondialdehyde level), were assessed in vitro using human peripheral blood cells as a model system. The influence of NPs on the morphology of lymphocyte cells studied using atomic force microscopy revealed that the membrane of cells remained unaffected after the treatment with NPs. When considering the effects of NPs on catalase activity and malondialdehyde level, neither particle type promoted oxidative stress. However, the treatment of lymphocytes with Ag@LM NPs induced a concentration-dependent enhancement of the micronuclei incidence and suppression of the cell proliferation while Au@LM NPs promoted cell proliferation, with no significant effects on micronuclei formation. The Ag@LM NPs were more prone to induce DNA damage than Au@LM NPs, which makes the latter type more suitable for further studies in nano-medicine. © 2019.

60 APPLIED LIFE SCIENCES↗

Correlation between energy deposition and molecular damage from Auger electrons: A case study of ultra-low energy (5–18 eV) electron interactions with DNA

Purpose: The present study introduces a new method to establish a direct correlation between biologically related physical parameters (i.e., stopping and damaging cross sections, respectively) for an Auger-electron emitting radionuclide decaying within a target molecule (e.g., DNA), so as to evaluate the efficacy of the radionuclide at the molecular level. These parameters can be applied to the dosimetry of Auger electrons and the quantification of their biological effects, which are the main criteria to assess the therapeutic efficacy of Auger-electron emitting radionuclides. Methods: Absorbed dose and stopping cross section for the Auger electrons of 5–18 eV emitted by{sup 125}I within DNA were determined by developing a nanodosimetric model. The molecular damages induced by these Auger electrons were investigated by measuring damaging cross section, including that for the formation of DNA single- and double-strand breaks. Nanoscale films of pure plasmid DNA were prepared via the freeze-drying technique and subsequently irradiated with low-energy electrons at various fluences. The damaging cross sections were determined by employing a molecular survival model to the measured exposure–response curves for induction of DNA strand breaks. Results: For a single decay of{sup 125}I within DNA, the Auger electrons of 5–18 eV deposit the energies of 12.1 and 9.1 eV within a 4.2-nm{sup 3} volume of a hydrated or dry DNA, which results in the absorbed doses of 270 and 210 kGy, respectively. DNA bases have a major contribution to the deposited energies. Ten-electronvolt and high linear energy transfer 100-eV electrons have a similar cross section for the formation of DNA double-strand break, while 100-eV electrons are twice as efficient as 10 eV in the induction of single-strand break. Conclusions: Ultra-low-energy electrons (<18 eV) substantially contribute to the absorbed dose and to the molecular damage from Auger-electron emitting radionuclides; hence, they should be considered in the dosimetry calculation of such radionuclides. Moreover, absorbed dose is not an appropriate physical parameter for nanodosimetry. Instead, stopping cross section, which describes the probability of energy deposition in a target molecule can be an appropriate nanodosimetric parameter. The stopping cross section is correlated with a damaging cross section (e.g., cross section for the double-strand break formation) to quantify the number of each specific lesion in a target molecule for each nuclear decay of a single Auger-electron emitting radionuclide.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Measurement of the Stopping Power of Water for Carbon Ions Using Inverted Doppler Shift Attenuation

Carbon ion therapy has gained importance in cancer treatment due to its locally well confined dose distribution, but there is a significant lack of experimental data which is needed for dose calculations and estimation of biological damage. Since tissue is mainly comprised of water, the energy-dependent stopping power of water is the critical measure. Importantly, previous data gathered from experiments with light ions has been limited to water vapour and ice and neglected water in its liquid phase. Additionally, theoretical models regarding the stopping power cannot yet describe the complex charge transfer interactions of the projectile at velocities in the range of the mean velocity of the valence electrons of the traversed medium. There are also discrepancies in the amount of phase effects concerning water and water vapour cross sections. Despite its importance there exists no experimental data for the stopping power of water for carbon ions in the energy region between 1 MeV and 5 MeV. This may be due to the short track length of carbon ions which makes traditional transmission experiments unfeasible. Therefore a project was launched to measure the stopping power of liquid water for carbon ions in the vicinity of the Bragg peak which corresponds to the energy regime of the maximum stopping power. For this measurement the inverted Doppler shift attenuation method was used. This uses the gamma quanta emitted from excited carbon nuclei which are produced by means of the {sup 12}C(α,α'){sup 12}C* reaction. The recorded γ-spectra contain the information of the projectiles velocity at the time they decay to their ground state and an internal clock provided by the exponential decay law. The deceleration of the projectile is directly connected to the stopping power which can be determined with this method as a function of the projectiles kinetic energy. Further measurements have been carried out to improve the experimental method. The setup and the preliminary results of this study will be presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic Field Dependence of Magnetotransport Properties of MgB{sub 2}/CrO{sub 2} Bilayer Thin Films

In this work, we comparatively investigated two MgB{sub 2} films: one (F1) was typically fabricated using the PLD method, while the other (F2) was fabricated using the same method but on top of a 100-nm-thick CrO{sub 2} layer. Both films had a thickness of 300 nm and were annealed ex situ at 700 °C for 30 min before being investigated under an external magnetic field of up to ± 7 T. The activation energy (U{sub o}), upper critical field (H{sub C2}), irreversibility field (H{sub irr}), magnetoresistance (MR), and I-V characteristics for the two films were studied in detail, and the results were compared with theoretical models. XRD analysis showed that both films are c-axis-oriented, while the RRR values for the films were found to be 1.6 and 1.89, respectively. Experimental data showed a broadening of the R-T transitions for an increasing magnetic field, with such broadening observed to be wider for F2 due to surface superconductivity. The activation energy under magnetic fields ranging from 0 to 7 T was calculated using our data and compared with a theoretical model. In both films, U{sub o} followed a parabolic curve but was higher for F2 up to 6 T before sharply decreasing, while it continued to follow the same trend for F1 up to 7 T. The theoretical model was in good agreement with F1 for the full span of magnetic fields used. H{sub C2} and H{sub irr} were estimated and fitted using Ginzburg–Landau theory, but although the fitting was very good for F1, some modification in fitting parameters was required to obtain the same fitting for F2. Magnetoresistance and I-V characteristics confirm that the CrO{sub 2} layer in F2 leads to faster damage to the superconductivity property for high magnetic fields and temperatures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Calculated organ doses using Monte Carlo simulations in a reference male phantom undergoing HDR brachytherapy applied to localized prostate carcinoma

Purpose: The aim of this study was to obtain equivalent doses in radiosensitive organs (aside from the bladder and rectum) when applying high-dose-rate (HDR) brachytherapy to a localized prostate carcinoma using {sup 60}Co or {sup 192}Ir sources. These data are compared with results in a water phantom and with expected values in an infinite water medium. A comparison with reported values from proton therapy and intensity-modulated radiation therapy (IMRT) is also provided. Methods: Monte Carlo simulations in Geant4 were performed using a voxelized phantom described in International Commission on Radiological Protection (ICRP) Publication 110, which reproduces masses and shapes from an adult reference man defined in ICRP Publication 89. Point sources of {sup 60}Co or {sup 192}Ir with photon energy spectra corresponding to those exiting their capsules were placed in the center of the prostate, and equivalent doses per clinical absorbed dose in this target organ were obtained in several radiosensitive organs. Values were corrected to account for clinical circumstances with the source located at various positions with differing dwell times throughout the prostate. This was repeated for a homogeneous water phantom. Results: For the nearest organs considered (bladder, rectum, testes, small intestine, and colon), equivalent doses given by {sup 60}Co source were smaller (8%-19%) than from {sup 192}Ir. However, as the distance increases, the more penetrating gamma rays produced by {sup 60}Co deliver higher organ equivalent doses. The overall result is that effective dose per clinical absorbed dose from a {sup 60}Co source (11.1 mSv/Gy) is lower than from a {sup 192}Ir source (13.2 mSv/Gy). On the other hand, equivalent doses were the same in the tissue and the homogeneous water phantom for those soft tissues closer to the prostate than about 30 cm. As the distance increased, the differences of photoelectric effect in water and soft tissue, and appearance of other materials such as air, bone, or lungs, produced variations between both phantoms which were at most 35% in the considered organ equivalent doses. Finally, effective doses per clinical absorbed dose from IMRT and proton therapy were comparable to those from both brachytherapy sources, with brachytherapy being advantageous over external beam radiation therapy for the furthest organs. Conclusions: A database of organ equivalent doses when applying HDR brachytherapy to the prostate with either {sup 60}Co or {sup 192}Ir is provided. According to physical considerations, {sup 192}Ir is dosimetrically advantageous over {sup 60}Co sources at large distances, but not in the closest organs. Damage to distant healthy organs per clinical absorbed dose is lower with brachytherapy than with IMRT or protons, although the overall effective dose per Gy given to the prostate seems very similar. Given that there are several possible fractionation schemes, which result in different total amounts of therapeutic absorbed dose, advantage of a radiation treatment (according to equivalent dose to healthy organs) is treatment and facility dependent.

60 APPLIED LIFE SCIENCES↗

Limit Load and Buckling Analysis for Assessing Hanford Single-Shell Tank Dome Structural Integrity - 12278

The U.S. Department of Energy, Office of River Protection has commissioned a structural analysis of record for the Hanford single shell tanks to assess their structural integrity. The analysis used finite element techniques to predict the tank response to the historical thermal and operating loads. The analysis also addressed the potential tank response to a postulated design basis earthquake. The combined response to static and seismic loads was then evaluated against the design requirements of American Concrete Institute standard, ACI-349-06, for nuclear safety-related concrete structures. Further analysis was conducted to estimate the plastic limit load and the elastic-plastic buckling capacity of the tanks. The limit load and buckling analyses estimate the margin between the applied loads and the limiting load capacities of the tank structure. The potential for additional dome loads from waste retrieval equipment and the addition of large dome penetrations to accommodate retrieval equipment has generated additional interest in the limit load and buckling analyses. This paper summarizes the structural analysis methods that were used to evaluate the limit load and buckling of the single shell tanks. This paper summarizes the structural analysis methods that were used to evaluate the limit load and buckling limit states of the underground single shell tanks at the Hanford site. The limit loads were calculated using nonlinear finite element models that capture the progressive deformation and damage to the concrete as it approaches the limit load. Both uniform and concentrated loads over the tank dome were considered, and the analysis shows how adding a penetration in the center of the tank would affect the limit loads. For uniform surface loads, the penetration does not affect the limit load because concrete crushing and rebar yielding initiates first at the top of the wall, away from the penetration. For concentrated loads, crushing initiates at the center of the dome, so the penetration does reduce the concentrated limit load somewhat. However, the safety factors comparing the limit loads to the maximum allowable applied loads remain well above the required value of 3.0. The buckling analysis method accounts for the geometric imperfections, concrete creep, cracking and reinforcements, and concrete plasticity in determining the allowable buckling load limits. The method was demonstrated in this paper for the evaluation of a tank before and after a penetration is added in the dome center. Finite element buckling models were used to accurately calculate the linear critical buckling loads. The models showed that adding the penetration reduces the linear critical buckling load by only 2.5%. Bounding cases also showed that the possible range of soil support on the walls does not significantly affect the dome buckling loads. Buckling models of the full 360 deg. dome also showed that the dome is more resistant to buckling when the load is offset than when it is positioned over the center. These limit load and buckling analysis methods are being used at the Hanford site to assess the tank loads that can be safely applied during future waste retrieval activities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗