Search NASA⌕ Search

SEARCH · Search NASA

Results for “Recording systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

River Valley pluton, Ontario - A late-Archean/early-Proterozoic anorthositic intrusion in the Grenville Province

This paper presents Nd, Sr, and Pb isotopic data indicating a late-Archean/early-Proterozoic age for the River Valley anorthositic pluton of the southwestern Grenville Province of Sudbury, Ontario. Pb-Pb isotopic data on 10 whole-rock samples ranging in composition from anorthosite to gabbro yield an age of 2560 + or - 155 Ma. The River Valley pluton is thus the oldest anorthositic intrusive yet recognized within the Grenville Province. The Sm-Nd isotopic system records an age of 2377 + or - 68 Ma. High Pb-208/Pb-204 of deformed samples relative to igneous-textured rocks implies Th introduction and/or U loss during metamorphism in the River Valley area. Rb-Sr data from igneous-textured and deformed samples and from mineral separates give an age of 2185 + or - 105 Ma, indicating substantial disturbance of the Rb-Sr isotopic system.

Ashwal, Lewis D.↗

An evaluation of vertical drag and ground effect using the RSRA rotor balance system

A flight test program utilizing the Rotor Systems Research Aircraft (RSRA) main rotor balance system was conducted to obtain data for the helicopter configuration. The test program is discussed along with the employed data reduction methods, and the results. NASA 740, the RSRA used for the vertical drag test, was in the standard helicopter configuration. The 31-foot radius blades have a linear twist of eight degrees and NACA 0012 airfoil sections. Aspects of instrumentation are considered, taking into account the data recording system, the static calibration facility, and aspects of data calibration and processing. Attention is given to the test procedure, data analysis methods, balance measurements, the ground effect, and vertical drag. It is found that the RSRA rotor balance system is capable of providing high quality performance data. The vertical drag of the RSRA is 4%, compared to 2.9% predicted.

Flemming, R. J.↗

Loop interaction in the visible emission corona: Morphological details

Coronagraph observations of two post flare loop systems, recorded photographically in the emissions of Fe 14 (5303 A) and Fe 10 (6374 A), show occasional enhancements at the intersections of some loops. The brightness of such enhancements in the green line gradually increases to a maximum value several times greater than that of the legs of the loops and then declines with a typical lifetime approx. 30 to 60 min. In red line emission the loop systems are usually very faint, but show the same overall type of enhancement, with a lag in maximum brightness relative to that of the green line approx. 10 min. The electron density, derived from the cooling time, is approx. 10 to the 12th power/cu cm.

Smartt, Raymond N.↗

Computer controlled performance mapping of thermionic converters: effect of collector, guard-ring potential imbalances on the observed collector current-density, voltage characteristics and limited range performance map of an etched-rhenium, niobium planar converter

The effect of collector, guard-ring potential imbalance on the observed collector-current-density J, collector-to-emitter voltage V characteristic was evaluated in a planar, fixed-space, guard-ringed thermionic converter. The J,V characteristic was swept in a period of 15 msec by a variable load. A computerized data acquisition system recorded test parameters. The results indicate minimal distortion of the J,V curve in the power output quadrant for the nominal guard-ring circuit configuration. Considerable distortion, along with a lowering of the ignited-mode striking voltage, was observed for the configuration with the emitter shorted to the guard ring. A limited-range performance map of an etched-rhenium, niobium, planar converter was obtained by using an improved computer program for the data acquisition system.

Manista, E. J.↗

Summary Report of Mission Acceleration Measurements for STS-78. Launched June 20, 1996

The microgravity environment of the Space Shuttle Columbia was measured during the STS-78 mission using accelerometers from three different instruments: the Orbital Acceleration Research Experiment, the Space Acceleration Measurement System and the Microgravity Measurement Assembly. The quasi-steady environment was also calculated in near real-time during the mission by the Microgravity Analysis Workstation. The Orbital Acceleration Research Experiment provided investigators with real-time quasi-steady acceleration measurements. The Space Acceleration Measurement System recorded higher frequency data on-board for post-mission analysis. The Microgravity Measurement Assembly provided investigators with real-time quasi-steady and higher frequency acceleration measurements. The Microgravity Analysis Workstation provided calculation of the quasi-steady environment. This calculation was presented to the science teams in real-time during the mission. The microgravity environment related to several different Orbiter, crew and experiment operations is presented and interpreted in this report. A radiator deploy, the Flight Control System checkout, and a vernier reaction control system reboost demonstration had minimal effects on the acceleration environment, with excitation of frequencies in the 0.01 to 10 Hz range. Flash Evaporator System venting had no noticeable effect on the environment while supply and waste water dumps caused excursions of 2 x lO(exp -6) to 4 x 10(exp -6) g in the Y(sub b) and Z(sub b) directions. Crew sleep and ergometer exercise periods can be clearly seen in the acceleration data, as expected. Accelerations related to the two Life Science Laboratory Equipment Refrigerator/Freezers were apparent in the data as are accelerations caused by the Johnson Space Center Projects Centrifuge. As on previous microgravity missions, several signals are present in the acceleration data for which a source has not been identified. The causes of these accelerations are under investigation.

Hakimzadeh, Roshanak↗

A suspended anemometer system for measuring true airspeed on low-speed airplanes

A suspended anemometer system for calibrating pitot-static systems on low speed research airplanes is described. The anemometer measures true airspeed when suspended beneath the airplane on a long cable in regions of undisturbed air. The electrical output of the propeller driven tachometer is a sine wave, the frequency of which is proportional to true airspeed. The anemometer measures true airspeed over a range from 20 to 60 m/sec at altitudes to 3000 m, with an accuracy of + or - 0.5 percent of full scale range. This accuracy is exclusive of errors in the recording system. The stability of the suspended system was investigated and was found adequate in the airspeed range. For the purpose of determining the location of the anemometer relative to the airplane, a method is given for calculating the shape assumed by the deployed cable.

Kershner, D. D.↗

Flow visualization and characterization of evaporating liquid drops

An optical system, consisting of drop-reflection image, reflection-refracted shadowgraphy and top-view photography, is used to measure the spreading and instant dynamic contact angle of a volatile-liquid drop on a non-transparent substrate. The drop-reflection image and the shadowgraphy is shown by projecting the images of a collimated laser beam partially reflected by the drop and partially passing through the drop onto a screen while the top view photograph is separately viewed by use of a camera video recorder and monitor. For a transparent liquid on a reflective solid surface, thermocapillary convection in the drop, induced by evaporation, can be viewed nonintrusively, and the drop real-time profile data are synchronously recorded by video recording systems. Experimental results obtained from this technique clearly reveal that evaporation and thermocapillary convection greatly affect the spreading process and the characteristics of dynamic contact angle of the drop.

Chao, David F.↗

MARS 1414 recorder environmental tests

Environmental testing is described and the data of the Modular Airborne Recording System (MARS) 1414 is presented. The preliminary data marks a starting point for more complete thermal testing in the future. The unit was operated at +/-55 C at one atmosphere, -10 C at 75,000 feet (28 mm Hg)at the other. Temperatures at 13 locations on the unit were monitored and plotted against elapsed time. From the test results, some estimation can be made of ambient temperatures in which the heaters will operate and shut off. This data is sufficient to complete a preliminary analysis of the MARS 1414 Recorder, and to design further tests.

Langjahr, D.↗

Feasibility Study of a Rotorcraft Health and Usage Monitoring System ( HUMS): Usage and Structural Life Monitoring Evaluation

The objective of this study was to evaluate two techniques, Flight Condition Recognition (FCR) and Flight Load Synthesis (FLS), for usage monitoring and assess the potential benefits of extending the retirement intervals of life-limited components, thus reducing the operator's maintenance and replacement costs. Both techniques involve indirect determination of loads using measured flight parameters and subsequent fatigue analysis to calculate the life expended on the life-limited components. To assess the potential benefit of usage monitoring, the two usage techniques were compared to current methods of component retirement. In addition, comparisons were made with direct load measurements to assess the accuracy of the two techniques. The data that was used for the evaluation of the usage monitoring techniques was collected under an independent HUMS Flight trial program, using a commercially available HUMS and data recording system. The usage data collect from the HUMS trial aircraft was analyzed off-line using PC-based software that included the FCR and FLS techniques. In the future, if the technique prove feasible, usage monitoring would be incorporated into the onboard HUMS.

Dickson, B.↗

Field Validation of MVA Technology for Offshore CCS: Novel Ultra-High-Resolution 3D Marine Seismic Technology (P-Cable) (Final Report)

The objectives of the proposed study were to deploy and validate a specific monitoring technology, high-resolution 3D marine seismic (HR3D), appropriate for large-demonstration and commercial-scale offshore CCS sites. The project accomplished successful acquisition two HR3D seismic surveys. The first HR3D dataset was over the offshore injection site of the Tomakomai, Japan integrated pilot CCS project, which at the time of survey acquisition was actively injecting CO 2 . The first survey also represented a successful international collaboration between the DOE NETL program and Japan’s national CCS program and was the first successful acquisition and use of HR3D over an active CO 2 injection site (Meckel, Feng et al. 2019). The Tomakomai HR3D survey successfully tested a novel 4-streamer HR3D system array in which, for the first time, no cross-cable (aka “P-Cable”) was utilized and only four GeoEel streamers were used instead of the standard 12-streamer configuration. Consequently, this was not, strictly speaking, a deployment of the “P-Cable” system of (Planke and Berndt 2004) but rather a modified version, thereof, and it is the first known demonstration of the modified system configuration. One very positive outcome from the Japanese collaboration earlier in the project was the ability to learn from the Japanese how they used tail buoys with GPS to determine the position of the seismic source and receivers in time and space. Based on that experience, GCCC designed and built six GPS receivers that could be used to position the streamer receivers and the seismic source via tail buoys. A fundamental advance that was made on the original design, was the ability to directly power the tail buoy GPS units and transfer data through the streamers (i.e., vs. the batteries used at Tomakomai). The bulkiness of the GPS batteries caused drag and episodic surging of the buoys, which affected data quality by lifting up the tail end of the streamers so the receivers were not at the same depth. The units were tested onshore for accuracy and functionality, and the design was subsequently and successfully tested in marine acquisition mode during the SLP survey acquisition. The marine acquisition test and survey satisfied Subtasks 2.2.2, Novel Positioning Technology Selection and Subtask 2.2.3, Novel Positioning Technology Deployment. Results of the novel positioning technology selection (Subtask 2.2.2) were considered successful and will be incorporated in future HR3D seismic acquisition projects to reduce costs, improve deployment safety at sea, and integrate both seismic and data recording via a single data transfer through the streamers to the recording system. The project also established a permitting process through NETL NEPA compliance, which included an Environmental Assessment in a marine setting and is required for conducting these types of surveys using Federal funding. The permitting process charted a “boilerplate,” which can allow future surveys related to other funded projects to move forward more expeditiously. Future improvements that could be considered are more robust seals on the GPS module and stronger materials (especially joints) on tail buoy fabrication. These would increase fixed costs, but would be advisable and probably more economic long-term if multiple HR3D surveys are planned. Project Accomplishments include: • Pre-survey Sensitivity Study • Marine geochemistry methods and data analysis • Successful HR3D seismic dataset acquired @ Tomakomai active CO 2 injection marine site • Developed advanced seismic processing techniques • No NRMS anomalies detected in overburden; Demonstration of containment • Repeatability study • Second survey collected @ San Luis Pass, TX • 4D application using positioning techniques developed in the project for monitoring were successful

3D seismic GPS positioning↗

A Prototype Flux-Plate Heat-Flow Sensor for Venus Surface Heat-Flow Determinations

Venus is the most Earth-like planet in the Solar System in terms of size, and the densities of the two planets are almost identical when selfcompression of the two planets is taken into account. Venus is the closest planet to Earth, and the simplest interpretation of their similar densities is that their bulk compositions are almost identical. Models of the thermal evolution of Venus predict interior temperatures very similar to those indicated for the regions of Earth subject to solid-state convection, but even global analyses of the coarse Pioneer Venus elevation data suggest Venus does not lose heat by the same primary heat loss mechanism as Earth, i.e., seafloor spreading. The comparative paucity of impact craters on Venus has been interpreted as evidence for relatively recent resurfacing of the planet associated with widespread volcanic and tectonic activity. The difference in the gross tectonic styles of Venus and Earth, and the origins of some of the enigmatic volcano-tectonic features on Venus, such as the coronae, appear to be intrinsically related to Venus heat loss mechanism(s). An important parameter in understanding Venus geological evolution, therefore, is its present surface heat flow. Before the complications of survival in the hostile Venus surface environment were tackled, a prototype fluxplate heat-flow sensor was built and tested for use under synthetic stable terrestrial surface conditions. The design parameters for this prototype were that it should operate on a conforming (sand) surface, with a small, self-contained power and recording system, capable of operating without servicing for at least several days. The precision and accuracy of the system should be < 5 mW/sq m. Additional information is included in the original extended abstract.

Morgan, Paul↗

Emerging anomaly detection techniques for electronic health records: A survey

Background Anomaly detection in electronic health records (EHRs) is a cornerstone of biomedical informatics, with direct implications for patient safety, clinical decision-making, and the prevention of healthcare fraud. Once guided primarily by simple rule-based methods, the field has advanced rapidly, driven by increased computing power, richer and more detailed health data, and the rise of machine learning and deep learning techniques. The objective of this paper is to provide a comprehensive overview of modern approaches to detecting anomalies in EHRs, outlining their strengths, limitations, and relevance to key healthcare challenges. We review traditional statistical methods alongside newer ML- and DL-based strategies and hybrid models, with particular attention to how these techniques support transparency and build clinical trust. Methods This paper presents a thorough and critical survey through systematic review (PRISMA-based) of the latest anomaly detection strategies in time-sequence data domains within electronic health record systems. Results We explore a broad spectrum of methodologies, including statistical models, supervised and unsupervised learning approaches, hybrid frameworks, and state-of-the-art ML-based techniques that collectively advance the precision and scalability of detecting anomalies in complex clinical datasets. In addition to mapping current capabilities, we address the enduring challenges that hinder widespread implementation and provide a forward-looking perspective on the future of anomaly detection in the data-rich landscape of modern healthcare. Summary The advancement in AI-based approaches is reported along with the basic principles of the individual approaches and their applicability. The increased availability of high-quality data, advancements in DL approaches, and enhanced computation power are leading to more frequent adaptation of DL-based approaches. Emerging DL-based approaches that have been adapted in other domains or recently applied in the EHR domain are also discussed in detail. Although DL-based approaches can improve model predictions by incorporating comorbidities, their application is limited in low-frequency data domains (e.g., when the total available data remains in the single digits). Therefore, the user must carefully consider the application based on data availability.

Anomaly detection↗

First Time-Resolved Leader Spectra Associated With a Downward Terrestrial Gamma-Ray Flash Detected at the Telescope Array Surface Detector

Optical emissions associated with Terrestrial Gamma ray Flashes (TGFs) have recently become important subjects in space-based and ground-based observations as they can help us understand how TGFs are produced during thunderstorms. In this paper, we present the first time-resolved leader spectra of the optical component associated with a downward TGF. The TGF was observed by the Telescope Array Surface Detector (TASD) simultaneously with other lightning detectors, including a Lightning Mapping Array (LMA), an INTerFerometer (INTF), a Fast Antenna (FA), and a spectroscopic system. The spectroscopic system recorded leader spectra at 29,900 frames per second (33.44 μs time resolution), covering a spectral range from 400 to 900 nm, with 2.1 nm per pixel. The recordings of the leader spectra began 11.7 ms before the -18 kA return stroke and at a height of 2.37 km above the ground. These spectra reveal that optical emissions of singly ionized nitrogen and oxygen occur between 167 μs before and 267 μs after the TGF detection, while optical emissions of neutrals (H I, 656 nm; N I, 744 nm, and O I, 777 nm) occur right at the moment of the detection. The time-dependent spectra reveal differences in the optical emissions of lightning leaders with and without downward TGFs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A novel high frequency, high bandwidth, three phase Mach–Zehnder optical data link

In inertial confinement fusion, hydrogen isotopes are fused together under high pressures and temperatures. Typically, the duration of these experiments is incredibly short, on the order of around 60–150 ps. Due to the high radiation environment, a detector’s signal is typically data linked far distances to a protected location. The diagnostic challenge for fusion reaction history measurements is to measure signals of interest maximizing dynamic range while also maintaining time resolution on the order of 10 ps. In this work, we present a new experimental optical data link used to efficiently transport diagnostic signals over great distances to the recording system while not restricting the dynamic range. The concept of a three phase Mach–Zehnder modulator system is introduced as well as a description of the physical prototype. The initial results from testing at the OMEGA facility show that this system is a viable method for signal transportation.

47 OTHER INSTRUMENTATION↗