Search NASA⌕ Search

SEARCH · Search NASA

Results for “Residential Construction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

EUI Benchmarks for Net-Zero Energy Buildings in India

In our study we present EUI benchmarks for NZEBs for six building types across residential and non-residential typologies and for India's five climate zones. This approach is similar to the simulation-based benchmarks used by the B3 program in Minnesota, the Cal-Arch methodology in California, and the US Solar Decathlon approach, which combine simulations with actual building data. Of the six building types we explore one in detail with a range of operation scenarios, specifically narrowing down the EUI benchmarks for mixed-mode building operation and for variable temperature set-points as prescribed in the National Building Code of India.The contribution of this work is to provide rigorous end-use level EUI benchmarks for six building types, and to describe a method for simulation-based EUI benchmarks for mixed-mode operation with variable setpoints to highlight the difference between the standard approach used for the five building types and the On-Site Construction Worker Housing which additionally has the mixed-mode variable setpoint approach.On-Site Construction Worker Housings are typically poorly constructed temporary structures, without adequate thermal comfort, It is critical to provide adequate thermal comfort to protect people from the warming effects of climate change, and to discover super efficient and cost-effective ways to do so.The methodology used for the On-Site Construction Worker Housing (CWH) results in an 80% acceptability according to the India Model for Adaptive Comfort in the National Building Code of India. EUIs of all six buildings are 60% lower than the minimum compliance with India's Energy Conservation Building Codes, providing benchmarks for efficiency levels. The end-use level EUI benchmarks are now provided to over 1800 Solar Decathlon India participants so that they can compare the performance of their NZEB designs.In particular, the CWH results provide an insight into the importance of the mixed-mode operation with variable temperature set-points. The results from the simulation study show that for an NZEB target, the EUI with standard thermal comfort model and without mixed operation is 58.26 kWh/m2*year, while that with the variable set-points of the adaptive model with mixed mode operation is 24.23 kWh/m2*year. This is a 58% reduction in EUI. Given that many building types including residential, and non-residential operate in mixed mode, it is important to take this work further to develop mixed-mode operation NZEB benchmarks so that the carbon intensity of these buildings could be lower than the standard thermal comfort model approach.

benchmarking↗

Electric Vehicle Charging for Residential and Commercial Energy Codes: Technical Brief

Numerous studies show that sales of electric vehicles (EVs) have grown consistently over recent years in the U.S. The U.S. Energy Information Administration (EIA) estimated 3 million EVs were on the road in 2022, and the Edison Electric Institute (EEI) forecasts a total of 26.4 million EVs on the road by 2030. Based on this forecast, EEI projects the need for an additional 12.9 million EV charge ports by 2030. If EV charging infrastructure fails to keep pace with sales of EVs it could result in consumers stranded without options to power their vehicles. EVs are capable of providing substantial benefits to the consumers. EVs are less expensive to operate than conventional internal combustion engine vehicles, have lower maintenance costs, and have the convenience of fueling (charging) at home or work. Studies conducted in California show that costs associated with installing EV charging infrastructure can be substantially more expensive for retrofit scenarios compared to new construction, making inclusion of EV infrastructure in new construction codes a cost-effective policy option to increase infrastructure to meet growing demands. PNNL tracks adoption of mandatory EV provisions across the U.S. As of December 20, 2024, 12 states (California, Oregon, Washington, Colorado, New Mexico, Illinois, Maryland, Delaware, New Jersey, Rhode Island, Massachusetts and Vermont) and 53 local governments have added EV provisions to their building codes, local ordinances and zoning requirements. Originally published in 2022, this tech brief has been revised to align with recent model energy code committee discussions and published EV infrastructure code language. This technical brief summarizes market trends, costs and benefits, and provides sample code language for EV charging infrastructure for consideration to be included in model codes, such as the International Energy Conservation Code (IECC) and ANSI/ASHRAE/IES Standard 90.1, as well as directly by states and local governments in their building codes. The technical brief summarizes related efforts undertaken by states and local governments, and builds upon language considered during the 2021 and 2024 IECC development cycles.

2021 IECC↗

National Energy Education Development Project (NEED Project) (CRADA Final Report)

The U.S. Department of Energy Building Technologies Office (BTO) funds student competitions that introduce students to careers in the building sciences and increase public awareness around high-performance buildings to support the goal of developing, demonstrating, and accelerating the adoption of cost-effective technologies, techniques, tools, and services that enable high-performing, energy-efficient and demand-flexible residential and commercial buildings in both the new and existing buildings markets. The U.S. Department of Energy Solar Decathlon® (DOE/SD) is a flagship, high-visibility international competition started in 2002 that advances the goals of BTO by introducing students to building science careers; educating students and the public about the latest technologies and materials in high-performance buildings; encouraging student-led projects and research centered around building science; and demonstrating to the public the comfort and savings of homes that combine energy-efficient construction, home systems, appliances and innovative design with onsite renewable energy production. SD is a collegiate competition, comprising 10 contests, that challenges student teams to design and build highly efficient and innovative buildings powered by renewable energy. The winners will be those teams that best blend architectural and engineering excellence with innovation, market potential, building efficiency, and smart energy production. Solar Decathlon is comprised of two Challenges – Design Challenge (annual) and Build Challenge (biennial). The National Renewable Energy Laboratory (NREL) provides competition management for Solar Decathlon. NREL and Participant establish this CRADA to enable the success of the overall Solar Decathlon program by managing sponsorship funds and creating a K12 education program. Participant is to act as an Education Partner to Solar Decathlon, which includes: 1) accepting and dispersing sponsorship funds for DOE/SD; and 2) providing K12 education program to support Solar Decathlon Competition Events in April each year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and analysis of optimal pre-cooling in residential buildings

Existing pre-cooling strategies provide a means of shifting or reducing the peak demand and/or energy cost in residential buildings. However, majority of them are rule-based and therefore may not be optimal in terms of cost saving, leaving room for improvement. In this paper, an integer linear programming problem that accounts for the thermal properties of a specific home, HVAC system capacity, utility rate structure, and weather conditions and makes use of a home thermal model is formulated. This problem determines the HVAC on/off control signal that minimizes the 24-h energy cost while maintaining thermal comfort and calculates the corresponding optimal indoor air temperature. The model is constructed using home thermal properties identified via data training in real-time. Through simulation, the energy performance of the proposed optimal pre-cooling strategy is investigated and compared with three rule-based operation strategies from the literature. It is found that the optimal strategy requires the least energy consumption without sacrificing thermal comfort. The superb energy performance of the optimal strategy is attributed to a longer runtime of the HVAC system in cool outdoor air conditions and to the elimination of deadband in HVAC operation, which is required by the rule-based strategies, to allow the indoor air temperature to stay near the thermal comfort upper bound as much as possible. In terms of energy cost, the rule-based operation strategies require 3.52, 1.90, and 2.79, respectively, while the optimal strategy only requires 1.52. These figures represent a saving of 56.82%, 20.00%, and 45.52%, respectively. The results suggest that the optimal strategy is indeed significantly more effective than the existing rule-based operation strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building the Efficiency Workforce: Preprint

Demand for high-performance homes and buildings is growing due to their marketability, environmental benefits, and increasing affordability. Growth for energy efficient technologies and building upgrades has driven expansion across many traditional industries including construction trades (which added almost 21,000 jobs) and professional services (which added 35,000 employees) in 2018, according to the 2019 U.S. Energy Employment Report (USEER). As buildings become more automated, digitized and interconnected, the workforce that supports the design, build, operations and maintenance of these buildings must evolve. The U.S. Department of Energy’s Building Technologies Office (BTO) has engaged NREL to provide a framework upon which BTO can develop their next generation workforce development strategy. The strategy will be designed to increase quantity of workers with the skills to adequately design, install, maintain and operate high- performance buildings across all building sectors (residential, commercial, industrial). This paper will summarize past BTO workforce development efforts, identify current skills gaps and hiring challenges, and present anticipated future workforce needs based on new technologies currently being developed by labs and industry. Through a literature review and a series of industry and academic workshops, NREL will present a framework that includes multiple options to best prepare the next generation workforce.

buildings↗

Design, fabrication, test, and qualification and price analysis of third generation design solar cell modules

The Block 4 shingle type module makes it possible to apply a photovoltaic array to the sloping roof of a residential building by simply nailing the overlapping hexagon shaped shingles to the plywood roof sheathing. This third-generation shingle module design consists of nineteen series connected 100 mm diameter solar cells which are arranged in a closely packed hexagon configuration to provide in excess of 75 watts/sq m of exposed module area under standard operating conditions. The solar cells are individually bonded to the embossed underside of a 4.4 mm thick thermally tempered piece of glass. An experimental silicone pottant was used as the transparent bonding adhesive between the cells and glass. The semi-flexible portion of each shingle module is a composite laminate construction consisting of an outer layer of FLEXSEAL bonded to an inner core of closed cell polyethylene foam. Silaprene is used as the substrate laminating adhesive. The module design has satisfactorily survived qualification testing program which includes 50 thermal cycles between -40 and +90 C, a seven day temperature-humidity exposure test, and a wind resistance test.

Shepard, N. F.↗

User Friendly Web-Based Tool to Assess the Energy Efficiency and Durability of Residential Wall Retrofits

According to the U.S. Department of Energy Windows and Building Envelope Research and Development Roadmap for Emerging Technologies, building envelope wall energy loss in the United States accounts for about 5.9 x 1010 kWh or 2 quads of energy annually, costing homeowners and occupants billions of dollars. Enclosure retrofits targeting these losses can save significant energy, reduce greenhouse gas emissions, and save occupants millions of dollars over time. Older homes, built before 1992 when DOE’s Building Energy Codes Program was established, represent approximately 68 percent of the residential building stock in the country, often having significant air leakage and inadequate insulation. Homes with little to no air sealing or insulation have heating and cooling losses that can represent a substantial portion of utility bills.High-performance building envelope retrofit systems are rarely selected for retrofit applications. Current solutions are expensive and/or unfamiliar to many designers, builders, contractors, and code officials and therefore are perceived as risky. The dominant perceived risk is durability specifically related to condensation and moisture accumulation in the building envelope component.The Building Science Advisor (BSA) is a rule-based expert system web-based tool that was originally developed to assist building professionals in designing energy efficient and durable wall systems for new construction. With the present focus being placed on upgrading the existing building stock, a retrofit module has been developed that, based on the location, existing construction, and planned retrofit strategy, provides recommendations on how to address the retrofit in a manner that will perform in accordance with IECC 2018 building code and not create a durability problem. This paper will describe the development of this tool and demonstrate its features and capabilities.

Desjarlais, Andre Omer↗

Installation Quality Framework: Investment Return Approach for Energy Savings on Building Product Installation

A case study was conducted on 44 residential homes using both traditional house wrap and ZIP System systems to measure the overall airtightness and compare estimated energy usages. The labor, material, and overhead and profit (O&P) costs were analyzed and used to determine the optimal choice for long-term benefits in terms of cost and performance. The impact of insulation installation is considered a key factor in improving the strategy of reducing energy consumption. Improved installation practices can affect the airtightness of common wall assemblies to reduce the building energy performance gaps and provide insight on how to allocate resources better. A framework was developed to analyze operational costs and building energy performance to address how installation quality is a factor in the return of investment in building construction for heating and cooling systems within the thermal envelope. With this methodology, aggressive energy performance goals will be met while balancing the tradeoff between installation techniques and building systems efficiency based on the introduced probabilistic investment return (PIR) metric.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The impact of simplified window and exhaust fan assumptions on indoor air quality in multifamily buildings

In residential buildings, the indoor air quality can be significantly affected by ventilation measures initiated by occupants, including the operation of windows and in-unit exhaust fans in kitchens and bathrooms. Many simulations simplify these factors by disregarding window opening behaviors and using fixed schedules for exhaust fan operation across all residential units. To estimate the impact of these simplifications in the U.S. context, this study used coupled CONTAM and EnergyPlus models to simulate airflow and contaminant transport in multifamily buildings. The coupled models parametrically varied climate zone, building airtightness, and mechanical ventilation system types. The study conducted a sensitivity analysis on two key occupant behaviors: (1) operating kitchen and bathroom exhausts on different schedules in individual dwelling units, and (2) scheduling open windows on ground and top floors. The simplified assumptions (i.e. uniform in-unit exhaust fan operation and window operation) had a minimal impact on inter-unit air flow and contaminant transport simulations across a broad range of building air leakage and mechanical ventilation system types. These findings suggest that for buildings with tight construction it is reasonable for most modelling and simulation efforts to ignore the effects of non-uniform exhaust fan operation and window opening.

Occupant behavior↗

What to expect when you're expecting engagement: Delivering procedural justice in large-scale solar energy deployment

Community engagement in the planning process to build large-scale solar (LSS) projects can win local support and advance procedural justice. However, an understanding of community engagement in current LSS development is lacking. Using responses from a U.S. nationwide survey (n = 979) of residential neighbors living within 3 miles (4.8 km) of completed LSS projects (i.e. “solar neighbors”) and project details from the U.S. Large-Scale Solar Photovoltaic Database (USPVDB), this study seeks to answer the following questions: How are solar neighbors' perceptions of community engagement associated with their attitudes toward their LSS projects? How do solar neighbors' perceptions of community engagement compare to their expectations? And, how do neighbors explain what they perceived about the planning process? We answer these questions using mixed methods, including regression modeling, a new gap analysis technique, and qualitative coding. We find that higher perceived engagement is associated with more positive attitudes toward the project, even when controlling for respondents who acted in opposition. Supporters and opponents alike expect more engagement than they perceived and information about projects both before construction and after operation is lacking. Awareness and engagement expectations increase at certain project size and proximity thresholds. However, most neighbors expect the public to offer input during engagement, but not make decisions. We contextualize these findings with explanatory comments from respondents.

14 SOLAR ENERGY↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Waffle Homes: Utilizing Aerial Imagery of Unfinished Buildings to Determine Average Room Size

A primary function of the Population Density Tables Project (PDT) at Oak Ridge National Laboratory is to produce residential population densities per 1000 sq. ft. for each country and their associated first-level administrative units. This is accomplished by utilizing the average size of different types of dwelling areas (urban, rural, single-family, multi-family, etc.) and the average household size provided by a country’s Census or statistical bureau records. This data is available for the majority of Europe, North America, and large swathes of Asia, but is less easily found in Africa and South America. In these regions, Censuses generally report dwelling area by number of rooms, which poses the challenging question of how we can translate number of rooms to dwelling size when no dwelling size areas are available with which to compare. Using sub-meter resolution satellite imagery of Accra, Ghana, this challenge can be tackled using imagery of roofless buildings currently under construction that show the interior floor plan of the dwelling. A sample of buildings from the different neighborhoods of Accra can be digitized to provide an estimate and range of average room sizes of dwellings. This average room size can then be translated to a total dwelling area using the "number of rooms occupied by a household" variable from the Ghanaian Census. This intermediate step between average dwelling size and number of rooms occupied, fills the missing link that prevents PDT from continually producing new population densities for countries where dwelling size is unavailable through any official means.

Woody, Carson↗

Exploring the Impact of Near-Term Innovations on the Technical Potential of Land-Based Wind Energy

Land based wind may play a critical role in reaching emissions reductions goals and high renewable contribution scenarios with capacity expansion modeling results estimating over 1 terawatt of land-based wind by 2035 to reach 100% clean electricity. Deployment of land-based wind at this magnitude may require significant investments in transmission infrastructure and will require significant land area for new wind and transmission. Cost reductions via technological advancements in wind turbine design, construction, and maintenance will have a major role in enabling the scale of deployment required. Since 1998, the levelized cost of wind energy has fallen by over 60% due to improvements in capacity factors, advancements in turbine controls, and cost reductions in installation, operation, and maintenance. These cost reduction pathways, generally referred to as wind technology "innovations", have enabled significant increases in the capacity and electric generation share of wind power in the United States. Nevertheless, achievements of past wind innovations have not led to widespread wind deployment outside of high wind speed geographies. This study evaluates the potential of near-term innovations to expand the geographic range of economically viable land-based wind power production in the United States. Many challenges to future deployment of wind power can be associated with increasing concentration in high-wind areas. As more wind power is deployed in these same areas, it is likely that residential and regulatory resistance to further deployment will increase, access to transmission will diminish, and options for distant companies and governments with renewable energy goals will remain limited. Therefore, this analysis aims to emphasize the potential for innovations to enable land-based wind in regions with limited wind deployment and with lower wind resource and better access to transmission.

17 WIND ENERGY↗

Life-Cycle Analysis of Residential Windows Retrofits: Net GHG Emission Reduction and Payback Periods

Windows are a critical envelope component that plays an important role in the overall performance and environmental impact of a building life cycle. These implications can be embedded in the window lifecycle related to its design, manufacturing, raw materials and transportation, performance during the building’s use (operational), replacements, maintenance and end-of-life. Windows may impact 25% of the heating and cooling energy use, 10% of total building energy use and 45% of the envelope heat transfer (Harris 2022). The impacts of windows on the energy consumption of buildings have been extensively discussed, however, its embodied life-cycle impacts, such as greenhouse gas (GHG) emissions, and the trade-offs between the embodied and its operational emissions are less explored. Understanding the life cycle impacts of windows may subsidize decision making process and inform the development of emerging windows technologies. BTO’s Windows Program has played an important role to increase the adoption of emerging technologies as high-performance windows in the U.S. (Harris 2022) and to consider the GHG emission impacts of the those windows is an important aspect that can support the strategic objectives and the performance targets from the national blueprint for decarbonizing the buildings sector and to reduce the on-site emissions and embodied life cycle emissions from building materials and construction (US DOE 2024).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of the INL Thermal Energy Distribution System (TEDS) in the Modelica Eco-System for Validation and Verification

This report provides an overview on the development of the Thermal Energy Distribution System (TEDS) in the Modelica process model eco-system at Idaho National Laboratory as part of the integrated energy system initiative. Model development has led to the creation of a dynamic process model of the experimental TEDS facility housed within the Engineering Science Laboratory (ESL) at INL. The model was then used during the pre-construction phase of the experimental effort to inform experimental design (insulation requirements, bypass line placement, expected performance of components) and to test innovative control schemes prior to the initial operation. The TEDS model developed in Modelica includes the primary components of the TEDS experimental unit including: a 200kW Chromalox heater, a single-tank packed bed thermal energy storage system filled with 0.125 inch Alumina (Al 2 O 3 ), an ethylene-glycol to Therminol-66 heat exchanger, system piping, six control valves, and all associated temperature, pressure, and mass flow sensors. The model does not include nitrogen fill gas tanks, or associated overfill tanks, as these are not part of standard system control. Two simulation sets were run. The first is a five-hour test that operates as a shakedown test for the facility. This simulation puts the facility through all five potential operating modes and showcases the ability of valving, control sensors, and component controllers to meet the system demands. The second case imposes a typical summer day demand on the system from a region with mixed commercial and residential electrical needs where the generator alone cannot meet peak demand but instead requires the thermal storage unit to act as a peaking unit. Over the course of the fifteen-hour discharge cycle heat losses account for a heat loss of approximately 15°C in outlet temperature. Such heat losses would lead to a decrease in overall system efficiency and may lead to additional design changes for such designs in the future that may include a topping heater. Through commencement of this work, a systems level model of TEDS with associated control systems, sensors, piping diameters, and component capabilities has been created. This model has been utilized in the pre-experimental phase to inform system design, insulation thicknesses, and potential control schemes to operate the system effectively and safely. Once TEDS begins operation, this model will be refined, tuned, and used for validation and verification purposes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

How close are urban scale building simulations to measured data? Examining bias derived from building metadata in urban building energy modeling

Residential and commercial buildings in the United States accounted for 40% of total energy in 2020. Building energy modeling (BEM) is a useful tool that allows individuals, researchers, companies, or utilities to save energy by optimizing buildings through estimation of building technology savings and performance projection of building energy under various environmental conditions. Urban building energy modeling (UBEM) expands the scope beyond individual buildings to the buildings in a neighborhood, city, utility and more. Yet there is a knowledge gap in the literature as to how these models compare to measured data on an individual and aggregated basis. As UBEM data and methods continue to develop, it is important to consider the accuracy, bias, and limitations of the models. Here, nation-scale data and UBEM software suite named Automatic Building Energy Modeling (AutoBEM) was used to model 50,843 buildings in Chattanooga, Tennessee. The uncalibrated simulation results were compared to aggregated 15-minute electricity data for the year 2019 with visualizations highlighting sources of bias in building data and the AutoBEM framework while considering how they relate to other UBEM methods. Estimation of building type and year of constructions are found to be the major sources of bias. Accounting for the amount of conditioned area per building significantly improves the overall fit of the simulated energy use intensity. it was found that inherent variation in building energy use contributes to R 2 values between 0.008 and 0.095 across building types but slope values near 1 for the total number of buildings. This indicates the need for building aggregation for representative building energy modeling with data sources available at an urban scale while illustrating the need for additional individual building data and model improvement beyond the originally produced UBEM models for individual building analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fire Station #2, Former Sewage Treatment Plant #17, and Towway Area-SWMU 114 PFAS Site Assessment Progress Report Kennedy Space Center, Florida

This PFAS Site Assessment Progress Report (SAPR) presents the findings of the 2022 PFAS investigation conducted from November 2021 through August 2022 at Solid Waste Management Unit (SWMU) 114 located within Kennedy Space Center (KSC), Florida. SWMU 114 includes area around Fire Station #2, Former Sewage Treatment Plant #17, the southern portion of the Shuttle Landing Facility Runway, Remote Launch Vehicle Hangar, and the Towway area. Fire Station #2 was constructed in 2008 and is currently active, housing fire station personnel and equipment, including aqueous film forming foam (AFFF). Releases of AFFF has occurred at SWMU 114. Previous environmental assessments have been performed at SWMU 114, including soil, groundwater, and surface water sampling for volatile organic compounds, polycyclic aromatic hydrocarbons, total petroleum hydrocarbons, and metals. No active remediation has been performed at the SWMU 114. PFAS site assessment field activities were conducted at SWMU 114 from November 2021 through August 2022. During the 2021-2022 Site Assessment, 124 direct-push samples were collected from 27 locations, 17 surface water samples were collected from 15 locations, 41 groundwater samples were collected from 37 newly installed monitoring wells, five concrete samples were collected from four locations, and one asphalt sample was collected. Additionally, two soil borings were advanced to 60 feet for lithologic descriptions, ten staff gauges were installed, and one round of water level measurements were collected from monitoring wells and staff gauges for groundwater flow determination. All groundwater and surface water samples were analyzed for 25 PFAS analytes by USEPA Method 537M. Concrete, and asphalt samples were analyzed by synthetic precipitation leaching procedure (SPLP) PFAS analysis by USEPA Modified Method 537M. Groundwater results were compared to the most recent Regional Screening Levels (RSLs) published by USEPA for residential tap water (USEPA, 2022a) to determine the extent of PFAS contamination at SWMU 114 for six PFAS analytes (PFOA, PFNA, PFBS, PFHxS, PFOS, and GenX). Surface water results were compared to the FDEP surface water screening levels (SW SLs) (FDEP, 2020) for PFOA and PFOS. The PFAS investigation concluded that groundwater exceeding RSLs extends east and south to Banana Creek and west to approximately the center of the SLF runway. The extent of PFAS is approximated to the north, to an area between Sharkey Road and Astronaut Road, where samples below the RSLs do not fully bound SWMU 114. At least two distinct PFAS source areas are located near Fire Station #2 and along Towway, at S114-MW0007S, within SWMU 114. Groundwater head measurements indicate that flow at SWMU 114 is generally similar across the shallow and intermediate water tables. A northeast to southwest trending groundwater divide is located near the middle of Towway where groundwater southeast of the divide flows to the south and groundwater northwest of the divide flows to the west. The groundwater divide generally separates the two areas of higher PFAS concentrations. Surface water samples indicated concentrations of PFOS above the SW SLs in surface water bodies across the site. Further assessment and sampling are required to better understand the interaction between groundwater and surface water at SWMU 114. Concrete and asphalt samples collected confirm that a significant release of AFFF occurred near the stormwater pond northwest of Fire Station #2. Additional concrete samples surrounding Fire Station #2 and at the northwest and southeast edges of the SLF tarmac indicate elevated PFOS concentrations. These results indicate that discharges of AFFF in these locations have infiltrated into asphalt and concrete and may act as a continuing source of PFAS to groundwater and surface water after rain events. Additional direct-push samples are required to delineate PFAS at SWMU 114. Samples may need to extend beyond the Former SLF Rescue Building and Morpheous Test Site to delineate PFAS in groundwater. Monitoring wells should be sampled and gauged quarterly to determine if seasonal impacts are observable, especially in shallow wells near surface water features. Furthermore, surface water samples should be collected from additional ditches to further define the extent of surface water impacts at SWMU 114 and extending along the SLF runway. Staff gauges should be gauged quarterly with groundwater gauging to determine surface water flow and interaction with groundwater. The PFAS sampling results and path forward for SWMU 114 were presented to the KSC Remediation Team in October 2022. Once the PFAS SAPR is approved, it will be submitted to the Florida Department of Environmental Protection.

Howard Franklin Fowler↗

Empirical Validation of UBEM: An Assessment of Bias in Urban Building Energy Modeling for Chicago

Residential and commercial buildings currently account for 30% of total global final energy consumption. Urban-scale building energy modeling (UBEM) can enable scalable investments and unlock building improvements by quantifying energy, demand, emissions, and cost reductions of specific measures or packages for building-specific technologies in large geographic regions. While the sophistication of UBEM data sources and technologies have increased dramatically in the past decade, there remains a knowledge gap for empirical validation and sources of bias between building-specific energy models and measured data at varying geographic scales.As UBEM continues to develop, systemic analysis of accuracy, bias, and limitations of the resulting models is necessary to inform best practices and move toward standardization. These are characterized for the Automatic Building Energy Modeling (AutoBEM) software suite with an initial case study involving metered electricity consumption data from 247,188 buildings in Chicago, Illinois, USA - averaged across years 2019-2021 - compared to the following datasets: (1) the AutoBEM-generated nation-scale Model America version 2 (MAv2) data for 596,064 buildings, (2) tax assessor data for 579,829 buildings, (3) tax assessor data filled with MAv2, and (4) 102 representative dynamic archetypes. The accuracy is reported for every building type and vintage combination, along with multiple sources of bias for unique building descriptors. The AutoBEM simulation workflow produced energy consumption estimates that closely match aggregated metered electricity consumption data for different types of buildings constructed during various time periods at the city scale - with initial normalized mean bias error of 10.9%, and 1.1% after removing outliers. Contribution of statistically significant factors including building type, land use, age, and size to variance in UBEM bias is quantified.

Garg, Ankur↗