Search NASA⌕ Search

SEARCH · Search NASA

Results for “Risk ratio”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

The Effects of Mixing Multi-Component HLW Glasses on Spinel Crystal Size

The Hanford Waste Treatment and Immobilization Plant will vitrify radioactive waste into borosilicate glass. The high-level waste (HLW) glass formulations are constrained by processing and property requirements, including restrictions aimed at avoiding detrimental impacts of spinel crystallization in the melter. To understand the impact of glass chemistry on crystallization, two HLW glasses precipitating small (?5 µm) spinel crystals were individually mixed with a glass that precipitated large (?45 µm) spinel crystals in ratios of 25, 50, and 75 wt%. The size of spinel crystals in the mixed glasses varied from 5 to 20 µm. Small crystal size was attributed to: (1) high concentrations of nuclei due to the presence of ruthenium oxide and (2) chromium oxide aiding high rates of nucleation. Results indicate that the spinel crystal size can be controlled using chromium oxide and/or noble metal concentrations in the melt, even in complex mixtures like HLW glasses. Small crystals tend to settle slowly, so they are acceptable in the melter without a risk of failure. Allowing higher concentrations of spinel-forming waste components in the waste glass enables glass compositions with higher waste loading, thus increasing plant operational flexibility. An additional benefit to the presence of chromium oxide in the glass composition is the potential for the oxide to protect melter walls against corrosion.

Lonergan, Charmayne E.↗

Default Radioactive and Hazardous Waste Management (RHWM) Dose Conversion Factors (DCFs) and Weighting Factors and plutonium-239 equivalent Curie (PE-Ci) methodology for acceptance into the Waste Storage Facilities

DOE-STD-5506-2007 (Ref. 1) is the standard that provides the methodology for preparing hazard analysis and accident analysis for transuranic (TRU) waste facilities. The Waste Storage Facilities hazard and accident analysis for the DSA is developed in accordance with DOE-STD- 5506-2007. Two related issues need to be addressed when implementing DOE-STD-5506-2007 regarding the calculation of consequences from TRU waste releases in accident analysis: Consequences determined in accident analysis must be modeled using inhalation Dose Conversion Factors (DCFs) that are consistent with those from the International Commission on Radiological Protection Publication 72 (ICRP-72, Ref. 2).; The use of a statistical Material at Risk (MAR) representing the distribution of radiological loading of TRU waste containers based on the use of a plutonium-239 equivalent Curie (PE-Ci) methodology. The PE-Ci methodology simplifies accident analysis by allowing one to model releases based on the Curie value of one standard nuclide (e.g., Pu-239) instead of needing to model releases for every potential nuclide of interest. This is accomplished by normalizing the Curie value of all nuclides to a single Curie value of a standard nuclide by using a Weighting Factor that is a ratio of the DCFs associated with the nuclides and that of the standard nuclide. By using the ICRP-72 DCFs to calculate PE-Ci values used in the statistical MAR, the accident analysis that uses that statistical MAR will be consistent with the consequence methodology identified in DOE-STD- 5506-2007.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CarcSeq Measurement of Rat Mammary Cancer Driver Mutations and Relation to Spontaneous Mammary Neoplasia

Abstract The ability to deduce carcinogenic potential from subchronic, repeat dose rodent studies would constitute a major advance in chemical safety assessment and drug development. This study investigated an error-corrected NGS method (CarcSeq) for quantifying cancer driver mutations (CDMs) and deriving a metric of clonal expansion predictive of future neoplastic potential. CarcSeq was designed to interrogate subsets of amplicons encompassing hotspot CDMs applicable to a variety of cancers. Previously, normal human breast DNA was analyzed by CarcSeq and metrics based on mammary-specific CDMs were correlated with tissue donor age, a surrogate of breast cancer risk. Here we report development of parallel methodologies for rat. The utility of the rat CarcSeq method for predicting neoplastic potential was investigated by analyzing mammary tissue of 16-week-old untreated rats with known differences in spontaneous mammary neoplasia (Fischer 344, Wistar Han, and Sprague Dawley). Hundreds of mutants with mutant fractions ≥ 10−4 were quantified in each strain, most were recurrent mutations, and 42.5% of the nonsynonymous mutations have human homologs. Mutants in the mammary-specific target of the most tumor-sensitive strain (Sprague Dawley) showed the greatest nonsynonymous/synonymous mutation ratio, indicative of positive selection consistent with clonal expansion. For the mammary-specific target (Hras, Pik3ca, and Tp53 amplicons), median absolute deviation correlated with percentages of rats that develop spontaneous mammary neoplasia at 104 weeks (Pearson r = 1.0000, 1-tailed p = .0010). Therefore, this study produced evidence CarcSeq analysis of spontaneously occurring CDMs can be used to derive an early metric of clonal expansion relatable to long-term neoplastic outcome.

McKim, Karen L.↗

Retrofitting Holcim Ste. Genevieve Cement Plant with CO2 Capture Plant Using Air Liquide Cryocap™ FG Technology

The global cement manufacturing industry is a major contributor to carbon dioxide emissions. The International Energy Agency's "Net Zero Emissions by 2050 Scenario" identifies CCS as a major strategy for meeting that goal. This project is among the first attempts to transfer capture technology developed at coal-fired power plants to the cement industry. The main objective of the project is to execute and complete a front-end engineering and design (FEED) studies for commercial-scale, carbon capture projects that separates 95% of the total CO2 emissions at the Holcim (US) Ste. Genevieve cement manufacturing facility using Air Liquide’s Pressure Swing Adsorption system (PSA) assisted Cryocap™ technology. The Holcim Ste. Genevieve cement plant in Missouri, US, boasts one of the largest single cement production lines in the world, with a capacity of approximately 12,000 t/day. The plant currently uses traditional fuels, namely coal and petcoke. The captured CO2 will be pipeline and geological storage grade. The industrial host site emits approximately 3.0 million tonne CO2/yr. Air Liquide’s Cryocap™ technology has been developed over the last 18+ years for CO2 capture applications. It has been shown to be applicable to a variety of industrial applications (e.g., steel, cement, SMR, Fluidized Catalytic Crackers (FCCs)). Cryocap™ FG consists of a Pressure Swing Adsorption (PSA) unit coupled with a Cryogenic System. The PSA pre-concentrates the CO2 from the flue gas, while the cryogenic unit enables the CO2 purity to be increased to the desired level. The project team is led by the Prairie Research Institute at the University of Illinois at Urbana-Champaign. The tasks include: complete FEED study for retrofitting the industrial facility with a carbon capture system to support developing a detailed cost estimate; business case analysis outlining the anticipated revenue and credits if projects was built and operated; technoeconomic analysis (TEA) outlining how capture system achieves DOE capture goals; and life cycle (LCA) analysis demonstrating zero net carbon emissions. The FEED study was successfully completed. This includes completing the process basis of design; preliminary engineering; outside battery limits (OSBL) detailed engineering including a Zero Liquid Discharge (ZLD) wastewater treatment system; inside battery limits (ISBL) detailed engineering [1]. An overall project capital cost estimate within a -20%/+30% accuracy was developed. The major contributors to the Total Plant Cost (TPC), by system, are the costs associated with the Outside Battery Limit (OSBL) section of the plant which includes a new river water intake structure and a Zero Liquid Discharge (ZLD) system. By cost category, the major contributors to the TPC are equipment and subcontractor costs, followed closely by engineering, construction management, home office and contractor fees. The TEA has been created to reflect the findings of the project. It analyzes the economic performance of the Cryocap™ technology by reviewing the estimated capital costs, operating cost, and revenue. The Cost of Capture (COC) associated with the Cryocap™ technology for 95% CO2 capture, when considering NETL 2018 economic assumptions (42/58 debt/equity ratio, 5.15% interest on debt and 1.42% return on equity in real dollars) and 2022 economic assumptions (42/58 debt/equity ratio, 8.82% interest on debt and 4.90% return on equity in real dollars) was found to be much lower than that for the DOE-NETL’s base-line cases. The highest contributors to the COC are annualized capital expenditures (CAPEX) and electricity consumption which can be offset by using lower cost renewable sources. The LCA was conducted using OpenLCA which is an open-source software that is recommended by NETL. The database utilized for this study was a modified version of TRACI 2.1 (developed by the US. Environmental Protection Agency’s National Risk Management Research Laboratory and modified by NETL). The Cryocap™ FG technology does not consume fuels in significant quantities and does not utilize specialized chemical solvents subject to decomposition, such as those utilized in amine-based carbon capture systems. The Cryocap™ FG technology mainly utilizes electricity as its energy input; hence, its calculated emissions are mainly associated with the generation of electricity offsite and are dependent on the energy matrix of the grid at the time of project implementation. The water consumption impact of the Cryocap™ FG is mostly for makeup of the water lost by evaporation in the cooling tower; however, the carbon capture plant will be equipped with a ZLD system to avoid effluent streams and minimize water consumption. The successful construction and operation of this plant based on this study results will provide a means to demonstrate an economically attractive and transformational capture technology that can be used to retrofit existing plants and be deployed at new plants.

01 COAL, LIGNITE, AND PEAT↗

2D CFD of lean premixed hydrogen–air flame quenching under locomotive engine conditions

Hydrogen (H 2 ) is a promising fuel for reducing emissions in heavy-duty internal combustion engines (ICEs), but its low quenching distance increases the risk of flame propagation into narrow crevice regions, such as piston-liner gaps. This work uses detailed CFD simulations with finite-rate chemistry to investigate premixed H 2 –air flame quenching in a two-dimensional (2D) region consistent with the piston-liner gap of a diesel ICE. Model accuracy was assessed by comparison with experimentally measured quenching distances in an annular stepwise diverging tube (ASDT). A parametric study was conducted to assess the influence of crevice width (0.05–1.18 mm), pressure (50–150 bar), unburned gas temperature (431–573 K), and equivalence ratio ( Φ= 0.3–0.6). Results show that the critical Péclet number for flame survival is no greater than 3.25, consistent with prior literature, even under ultra-lean and high-pressure conditions (Φ ≤ 0.3, > 50 bar). Additionally, flames with Péclet numbers exceeding 6.15 exhibited front wrinkling, suggesting the onset of velocity-driven instabilities and enhanced flame robustness. These findings help define thresholds for flame quenching in confined geometries and support the safe design of H 2 fueled ICEs.

08 HYDROGEN↗

Applying U.S. metal fuel experience to new fuel designs for fast reactors

With the increasing interest in small modular reactors or microreactors, developers are working to design and submit licensing approval requests of U–10Zr-fueled fast reactors. The developers and their proponents cite prior metal fuel experience (worldwide, but U.S. experience in particular for many developers) as the motivation and justification for their reactor concepts. The experience with metal fuel deployment in sodium-cooled fast reactors as well as the underlying irradiation testing database, provide a suitable basis for analytically justifying the use of metal fuel in new reactors. The evolution of metal fuel design and capability illustrates the importance of key fuel design parameters to consider in new applications of the prior experience: fuel smeared density, plenum-to-fuel volume ratio, the ratio of cladding radius to thickness, fuel composition, and cladding and duct materials. In-service operating and deployment conditions to be considered include fuel linear heat generation rate, fuel temperature, cladding temperature, peak burnup and peak fast fluence. Fuel designs and in-service conditions that are bounded by the database and experience are most easily addressed, but deviations from those previous parameters and conditions can be addressed by considering impacts on previously established behavior and applying other mitigating conservatisms, as appropriate. Here, the authors recommend any new deployment proceed with fuel surveillance and monitoring to mitigate risk, application of conservative measures to address uncertainties, and a fuel qualification program that addresses a range of in-service operating conditions with production fuel. The work reported should be of interest to students and regulators unfamiliar with metal fuel in fast reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Superiority of compensatory reserve measurement compared with the Shock index for early and accurate detection of reduced central blood volume status

Shock index (SI) equals the ratio of heart rate (HR) to systolic blood pressure (SBP) with clinical evidence that it is more sensitive for trauma patient status assessment and prediction of outcome compared with either HR or SBP alone. We used lower body negative pressure (LBNP) as a human model of central hypovolemia and compensatory reserve measurement (CRM) validated for accurate tracking of reduced central blood volume to test the hypotheses that SI: (1) presents a late signal of central blood volume status; (2) displays poor sensitivity and specificity for predicting the onset of hemodynamic decompensation; and (3) cannot identify individuals at greatest risk for the onset of circulatory shock. We measured HR, SBP, and CRM in 172 human subjects (19–55 years) during progressive LBNP designed to determine tolerance to central hypovolemia as a model of hemorrhage. Subjects were subsequently divided into those with high tolerance (HT) (n = 118) and low tolerance (LT) (n = 54) based on completion of 60 mm Hg LBNP. The time course relationship between SI and CRM was determined and receiver operating characteristic (ROC) area under the curve (AUC) was calculated for sensitivity and specificity of CRM and SI to predict hemodynamic decompensation using clinically defined thresholds of 40% for CRM and 0.9 for SI. The time and level of LBNP required to reach a SI = 0.9 (~60 mm Hg LBNP) was significantly greater (p < 0.001) compared with CRM that reached 40% at ~40 mm Hg LBNP. Shock index did not differ between HT and LT subjects at 45 mm Hg LBNP levels. ROC AUC for CRM was 0.95 (95% CI = 0.94–0.97) compared with 0.91 (0.89–0.94) for SI (p = 0.0002). Despite high sensitivity and specificity, SI delays time to detect reductions in central blood volume with failure to distinguish individuals with varying tolerances to central hypovolemia.

60 APPLIED LIFE SCIENCES↗

Evaluation of Contact Resistance and Fin Effectiveness of Enhanced, Brazed "Dogbone" Fin and Serpentine Tube Heat Exchangers for Air Conditioning and Heat Pump Applications

The energy consumption due to air conditioning is projected to increase by 1.3 and 4.5 times by 2050 compared to 2010 for members and non-members of the Organization of Economic Coordination and Development (OECD), respectively. Greenhouse Gas (GHG) emissions must be carefully managed to minimize their hazardous contribution to climate change. Air conditioners (AC) and heat pumps (HP) contribute with direct GHG emissions through systemic refrigerant leakage, which consequently degrades the system’s performance and therefore increases its indirect GHG emissions as well. To address this issue, the goals of new systems include minimizing leakage risk, using low global warming potential (GWP) refrigerants such as natural refrigerants, and increasing system efficiency. This paper presents part of the efforts in the development of a brazed “dogbone” fin to continuous serpentine tube heat exchanger (HX) for AC/HP applications. The main advantages of such technology are: 1) The potential to reduce 90% or more of the tube return-bends brazed joints compared to conventional tube-fin heat exchangers, thus minimizing leakage vulnerability, enabling the use of natural refrigerants like Propane and Ammonia that carry other concerning risks of flammability and toxicity ; and 2) The brazed fin to the tube joints should yield very low contact resistance. In order to quantify and estimate the impacts of contact resistance and fin effectiveness, a numerical-experimental study is investigated. The novel enhanced brazed “dog-bone” fin is compared to an equivalent pressure expanded fin. The results showed that the expanded fin has consistently greater effective heat transfer but greater contact resistance as well. Furthermore, the brazed fins have up to 20% lower pressure drop. The trade-off comparison shows that the thermal-hydraulic ratio between the two fins is equivalent for air velocities below 2m/s; for greater velocities, however, the expanded fin is favored since it has less fin efficiency penalty. For HVAC&R applications, the air velocities are typically low which makes the proposed technology competitive and a viable option in the pursuit of refrigerant leakage reduction.

30 DIRECT ENERGY CONVERSION↗

Large Volume Airborne Contamination Monitoring To Support Nuclear Processes' Deactivation and Decommissioning

Current D and D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries - Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne Pu, putting numerous workers at risk for radiological assimilations - Current air samplers and CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required - Hanford is located in a high radon environment, making air monitoring for alpha emitting actinides challenging in high alpha radon induced backgrounds. - Inexpensive HEPA based home and industrial air purifiers filter significantly higher volumes of air than commercially available continuous-air monitoring (CAM) systems. - Inexpensive models capable of filtered air volumes exceeding 1000 times that of a CAM. - Detector system can be built to detect x-rays generated from actinide decay. - Branching ratios of x-rays are 4 orders of magnitude more intense from Plutonium decay than its gamma emissions. - Detector system can be a low resolution systems, as x-ray region of interest is not terribly congested. - Detection systems evaluated will be designed based on slabs of NaI or pixelated NaI or CsI panels. - Simple graphical user interface software will be developed to operate the detection system. - Concept is to deploy some of these air-purifying systems in nonradiological areas around SRNL to confirm radon can be rejected with confidence. - Generate some filters contaminated with plutonium via electroplated Pu or lab generated simulated particles. - then deploy units in known airborne radiological environments to establish systems ability to accurately measure actinide based hot particles Lab analyses will follow up the system analyses to ensure hot particles were correctly identified. Analysis by Scintillation: - Application of scintillation media to the surface of the filters is being explored. - Evaluating slabs of ZnS(Ag), application of powdered ZnS(Cu) and spray on Perkin Elmer Enhance. - Scintillation events would then be digitized with a digital camera and quantified. - Comparing against sensitivity of a PMT or SiPD readout. - Currently evaluating a Thorlabs 8 Megapixel Monochrome Scientific CCD Camera, hermetically sealed cooled package with a wide angle lens. - Wide angle lens allows complete view of HEPA filter from 7 inches away. - Images taken of glow in the dark paint, as well as plutonium-induced fluorescence. - Plutonium was flamed mounted on a 1 inch diameter stainless steel planchet, covered with a layer of mylar and a section of scintillating ZnS obtained from Eljon. - Currently working on reducing signal-to-noise levels to boost sensitivity. - Dark box to hold contaminated or electroplated source covered filters under fabrication. Analysis by x-ray Spectroscopy: - Branching ratios for x-ray emissions from Plutonium isotopes are orders of magnitude more intense than gamma-ray emissions. - The nuclear databases are incomplete on the branching ratios of some of the isotopes. - Evaluating some custom built SrI2 x-ray spectrometers vs a conventional windowed NaI detector. - SrI2 detectors are carbon-composite-windowed 51 mm x 51 mm. - MCNP calculations to establish self absorbance of filter media on 17 keV x-ray. Radon Rejection: - Activated charcoal pre-filter acts as a Radon trap. - Adding a time lapse feature to camera to aid in radon rejection. SRS Plutonium Fuel Form D and D Operations: Currently deploying air sampler to D and D operation of Pu-238 facility at SRS to generate some field samples to analyze.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Role of Histidine‐Containing Peptoids in Accelerating the Kinetics of Calcite Growth

Carbonate mineralization, the conversion of CO 2 into stable, thermodynamically favorable carbonate minerals, offers a promising strategy for permanent and environmentally friendly carbon storage, with minimal risk of long-term leakage and minimal monitoring requirements. Drawing inspiration from carbonic anhydrase (CA), a family of zinc-containing metalloenzymes that catalyze the hydration of CO 2 to bicarbonate and promote carbonate precipitation, a class of histidine-containing peptoids was designed that is capable of coordinating with Zn 2+ ions to act as CA mimetics for accelerating calcite step growth. In situ atomic force microscopy (AFM) measurements reveal that these peptoids significantly enhance step advancement, with a more pronounced effect observed when combined with Zn 2+ ions and under higher calcium-to-carbonate activity ratios, indicating that peptoids facilitate the incorporation of CO 3 2− ions at step edges. Solution NMR and 3D atomic force microscopy (3D AFM) analyses show that the coordination of peptoids with Zn 2+ promotes both the deprotonation of HCO 3 − to CO 3 2− and restructures the interfacial hydration layers of calcite, collectively lowering the activation barrier for step growth. These findings establish a design framework for sequence-defined polymers to regulate carbonate mineralization, offering promising applications in CO 2 capture and long-term storage.

CO2 mineralization↗

In-Situ and Ex-Situ Studies on the Morphology Changes of Polymer Pipeline Materials for Use in Hydrogen Gas Environments

The US natural gas infrastructure is a national asset that could be used to deliver hydrogen and hydrogen blends of natural gas as a pathway to reduce carbon emissions. The distribution system comprises nearly 50% plastic pipe composed of medium- and high-density polyethylene materials (MDPE and HDPE). While these materials perform adequately for natural gas, research on their hydrogen compatibility is essential to understand if any immediate and long-term risks are associated with hydrogen addition. The Blended Gas CRADA, a HyBlend project, has established a comprehensive test method for evaluating MDPE and HDPE of various plastic resin compositions of pipeline material in pure hydrogen and 20% hydrogen/80% methane blends. Both in-situ and ex-situ measurements were performed to capture hydrogen-induced changes in the polyethylene material's crystalline, amorphous and their interphase regions. We investigated MDPE and HDPE pipeline materials made from different polymer resin systems to evaluate the effects of hydrogen gas. The materials were characterized by their density, diffusion coefficient, free volume ratio, and degree of crystallinity. Various advanced characterization methods, including in situ NMR, ex situ XRD, ex situ DSC, and ex situ TDA, were used to analyze the effects of changes in crystalline, amorphous, and interphase regions due to gas exposure. Time-dependent post-decompression quasi-static tensile tests were conducted to explore the effects of gas exposure time on the mechanical behavior of the pipe materials. This work will highlight the time sensitivities during and after gas exposure. The correlation between gas-induced polyethylene morphology changes and the associated material performance will be addressed for the intended applications. These studies will show that polyethylene resin composition and material exposure are important factors when considering whether hydrogen gas affects pipeline materials positively or negatively.

Simmons, Kevin L.↗

Association between long-term exposure to ambient air pollution and COVID-19 severity: a prospective cohort study

The tremendous global health burden related to COVID-19 means that identifying determinants of COVID-19 severity is important for prevention and intervention. We aimed to explore long-term exposure to ambient air pollution as a potential contributor to COVID-19 severity, given its known impact on the respiratory system. Methods: We used a cohort of all people with confirmed SARS-CoV-2 infection, aged 20 years and older and not residing in a long-term care facility in Ontario, Canada, during 2020. We evaluated the association between long-term exposure to fine particulate matter (PM 2.5 ), nitrogen dioxide (NO 2 ) and ground-level ozone (O 3 ), and risk of COVID-19-related hospital admission, intensive care unit (ICU) admission and death. We ascertained individuals’ longterm exposures to each air pollutant based on their residence from 2015 to 2019. We used logistic regression and adjusted for confounders and selection bias using various individual and contextual covariates obtained through data linkage. Results: Among the 151105 people with confirmed SARS-CoV-2 infection in Ontario in 2020, we observed 8630 hospital admissions, 1912 ICU admissions and 2137 deaths related to COVID-19. For each interquartile range increase in exposure to PM 2.5 (1.70 µg/m 3 ), we estimated odds ratios of 1.06 (95% confidence interval [CI] 1.01–1.12), 1.09 (95% CI 0.98–1.21) and 1.00 (95% CI 0.90–1.11) for hospital admission, ICU admission and death, respectively. Estimates were smaller for NO 2 . We also estimated odds ratios of 1.15 (95% CI 1.06–1.23), 1.30 (95% CI 1.12–1.50) and 1.18 (95% CI 1.02–1.36) per interquartile range increase of 5.14 ppb in O 3 for hospital admission, ICU admission and death, respectively.

60 APPLIED LIFE SCIENCES↗

Study of a Proposed fissionTPC Measurement of 233 U(n,f)/ 235 U(n,f) Cross Section Ratio

A review of the available 233 U( n, f )/ 235 U( n, f ) cross section ratio data compared to the ENDF evaluation in the fast neutron energy range, 0.1–20 MeV, shows that discrepancies exist between some of the various measurements and the evaluation. The discrepancies vary and a function of incident neutron energy and range between 1–5%. In this document we review two potential options for performing new measurements of the cross section ratio to potentially resolve these discrepancies. The two options are compared and contrasted in terms of measurement accuracy and cost. The first option would utilize the fissionTPC, which was designed specifically to achieve measurement uncertainties of better than 1% to resolve a similar data–evaluation discrepancy in the 239 Pu( n, f ) cross section. While this would seem to be an ideal option in this case also, there are challenges. The fissionTPC is a complex instrument and the cost of maintenance and operations are significant. Furthermore, some of the fissionTPC equipment is nearing the end of its useful life which presents a risk to completion of a measurement campaign. The second option is to use a dual-fission chamber, which is the more traditional approach to these types of measurements. The cost is estimated to be about half that of a fissionTPC measurement, while the much simpler design of the detector reduces overall risk. The trade-off is the measurement uncertainty, which would be on order of 1–3% with a careful measurement and analysis. This uncertainty however may not be good enough to fully resolve the discrepancies. The objective of a new measurement would be the improvement in the ENDF evaluation with the end goal of improving the accuracy of models and simulations at the end of the nuclear data pipeline. An understanding of the sensitivity of these models to the data uncertainties would help guide the choice of measurement techniques.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Predicting Postoperative Injury and Military Discharge Status After Knee Surgery in the US Army

Background: Researchers have assessed postoperative injury or disability predictors in the military setting but typically focused on 1 type of surgical procedure at a time, used relatively small sample sizes, or investigated mixed cohorts with civilian populations. Purpose: To identify the relationship between baseline variables and injury incidence or military discharge status in US Army soldiers after knee surgery. Study Design: Case-control study; Level of evidence, 3. Methods: Data were obtained from a repository containing personnel, performance, and medical records for all active-duty US Army soldiers. Multivariate logistic regressions were used to estimate the effects of numerous variables on postoperative injury or on medical discharge. Variable selection and model validation were conducted using the k-fold method. Results: A total of 7567 soldiers underwent knee surgery between 2017 and 2019. Meniscal procedures were the most common type of surgery (39%), and approximately 71% of the cohort had a postoperative injury. Significant predictors for sustaining a postoperative injury included having a previous nonknee injury (odds ratio [OR], 1.5), female sex (OR, 1.3), and Black race (OR, 1.2). Within 4 years after surgery, 17% of soldiers were discharged from the military because of knee-related disability. Significant predictors for discharge from duty included enlisted rank (OR, 2.3), recent fitness test failure (OR, 1.9), number of previous knee surgeries (OR, 1.7), and having a previous nonknee injury (OR, 1.6). Conclusion: After knee surgery, nearly three-fourths of the soldiers in this cohort sustained a postoperative injury and almost one-fifth of soldiers were medically discharged from the military within 4 years. This study identified variables that indicate statistically increased risk for these postoperative outcomes and highlighted potentially modifiable factors.

Orthopedics↗

Towards Anomaly Detection at the CMS High-Level Trigger System

Traditional trigger strategies in CMS typically rely on model-dependent selections or rigid kinematic cuts, risking the omission of unexpected exotic signatures. To address this, we propose a novel anomaly detection (AD) algorithm for the High-Level Trigger (HLT), designed to serve as a complementary second layer of filtering to the Level-1 AXOL1TL AD algorithm. We employ a transformer-based foundation model trained on a diverse ensemble of Standard Model processes. By combining a joint contrastive and classification objective, and using particle kinematics as inputs, the model learns to map events to a physics-informed latent space where anomalous events are isolated from dominant backgrounds. Preliminary results show that this strategy enhances the signal-to-background ratio across a range of rare SM and BSM scenarios. Furthermore, this work constitutes foundational R&D for the potential implementation of an analogous AD algorithm in the Level-1 trigger system for Phase-2.

Cruz, Roy [U. Wisconsin, Madison (main)] (ORCID:00↗

Flood Susceptibility Mapping Using Machine Learning and Geospatial-Sentinel-1 SAR Integration for Enhanced Early Warning Systems

This study presents a comprehensive framework for flood susceptibility mapping by integrating geospatial factors with both statistical and machine learning models. Thirteen Flood-related factors, including DEM, slope, TWI, NDVI, etc., are extracted as features of models, and historical flood data derived from Sentinel-1 SAR from 2018 to 2023 are used as the target variables of the models. These datasets are analyzed using a frequency-based statistical model and three machine learning models, including Random Forest, XGBoost, and CNN, to generate flood susceptibility maps. The performance of each model is evaluated through AUC; and SHAP scores are separately generated for Machine learning (ML) models to explain each feature contribution in the ML model. The generated susceptibility maps are validated by high-flood-risk locations monitored by flood sensors, BLE inundation models, and flood-prone areas suggested by the Local Community Task Force. The results indicate that the XGBoost model outperforms all other models, with an AUC of 0.92 and demonstrates the highest alignment with recommended high-flood-risk locations, while the frequency-based statistical model showed the weakest performance with an AUC of 0.65. SHAP value graphs highlight the elevation, slope, and TWI as the most influential features across all models. The susceptibility maps generated by the machine learning model show strong agreement with the BLE map and high-flood-risk areas identified by the local Community Task Force.

Google Engine↗

Does Breast Density Increase the Risk of Re-excision for Women with Breast Cancer Having Breast-Conservation Therapy?

Background: Women with dense breasts may have less-accurate preoperative evaluation of extent of disease, potentially affecting the achievement of negative margins. The goal of this study is to examine the association between breast density and re-excision rates in women having breast-conserving surgery for invasive breast cancer. Patients and Methods: Women with stage I/II invasive breast cancer treated with breast-conserving surgery between 1/1/2014 and 10/31/2014 were included. Breast density was assessed by two radiologists. The association between breast density and re-excision was examined using logistic regression. Results: Seven hundred and one women were included. Overall, 106 (15.1%) women had at least one re-excision. Younger age at diagnosis was associated with increased breast density (p < 0.001). On univariable analysis, increased breast density was associated with significantly increased odds of re-excision (odds ratio [OR] 1.38, 95% confidence interval [CI] 1.04–1.83), as was multifocal disease, human epidermal growth factor receptor 2 (HER2) positive status, and extensive intraductal component (EIC) (all p < 0.05). On multivariable analysis, breast density remained significantly associated with increased odds of re-excision (OR 1.37, 95% CI 1.00–1.86), as did multifocality and EIC. HER2 positive status was not significantly associated with re-excision on multivariable analysis. Conclusions: Women with dense breasts are more likely to need additional surgery (re-excision after breast-conserving surgery), but increased breast density did not adversely affect disease-free survival in our study. Our findings support the need for further study in developing techniques that can help decrease re-excisions for women with dense breasts who undergo breast-conserving surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

GIS-Based Modeling of Contaminated Soil Volumes at Multiple Sites in the Formerly Utilized Sites Remedial Action Program - 20149

The remediation of hazardous, toxic, and radioactive waste (HTRW) sites produces cost-related risks associated with the estimation of contaminated soil or debris volumes. Historical risk-management techniques include cost contingencies to cover volume uncertainties that affect project budgeting and decision-making. The Buffalo District teamed with project partners to lessen volume uncertainty and reduce project risks at multiple HTRW sites managed under the Formerly Utilized Sites Remedial Action Program (FUSRAP). Historical remedial investigations under FUSRAP commonly identified the presence of radiological material in site media, the associated human health risk, and then areas of remediation. To manage remedial execution and reduce risk, pre-design or remediation-phase sampling essentially 'chased' contamination, which was not conducive to efficient predictive budgeting derived from Feasibility Study (FS) cost analyses. The Buffalo District first optimized their approach to better understand volume uncertainty by utilizing the Argonne National Laboratory's Bayesian Approaches for Adaptive Spatial Sampling (BAASS) software [1]. BAASS processed soft data (e.g., gamma walk-over data) and spatial sampling data to estimate the lateral extent of contaminated soil irrespective of depth (i.e., gross contamination extent) and define areas of contaminant uncertainty. The software performed a binary transformation of contaminant concentrations at all sampling points based upon remedial action goals or a sum of ratios approach (i.e., clean, impacted, or range of impacts in soil). The model produced two-dimensional (horizontal) contaminant probability contours and statistical uncertainty in the sampling coverage and resulting contaminant extents. This method was translated vertically by partitioning the sampling data into depth brackets that produced a stacked representation of contaminant extents and uncertainty in the subsurface (i.e., similar to construction lifts). The results commonly led to a better understanding of project uncertainty and the need for sampling strategies that produce high-confidence soil volumes, which control costs. The BAASS-based delineations were eventually replaced by Empirical Bayesian Kriging (EBK) methods available in ArcGIS Spatial or 3D Analysts [2]. The EBK method calculates contaminant probability zones derived from user-controlled semivariograms of the spatial datasets. The resulting probability zones (e.g., 50% or 80% of contaminant probability) represent the two-dimensional surface delineation of the overall horizontal remedial area, similarly to BAASS. However, unlike BAASS, the vertical sampling data within these probability zones became vertical control points to contour a subterranean surface that connects subsurface points to the land-surface delineations of contamination. The resulting representation of horizontal and vertical impacts within an enclosed envelop (volume) of soil included uncertainty distributions that are used to plan uncertainty-reduction sampling. These data-driven and math-based models of three-dimensional sampling results produced well-bounded remedial volumes for project planning and better uncertainty predictions during project budgeting. The EBK method was applied to several FUSRAP sites managed by the Buffalo District and compared to less rigorously modeled sites previously remediated by the District. The comparison of modeled to actual remediated volumes provide a basis for validating the volume-estimation method. This comparison is important to ensure modeled volumes match physical boundaries of site remediation. FUSRAP sites with denser investigative sampling and lesser volume uncertainty proved useful in remedial planning and contracting. The Buffalo District noted that historical sites with sparser sampling arrays had greater disparity between estimated volumes and final remedial volumes. The benefit achieved over the cost of detailed soil sampling appears positive for FUSRAP projects, especially where impacts vary widely and appear unbounded by investigation-phase sampling. The subsequent Empirical Bayesian Kriging of contamination coupled with vertical contouring for soil estimations reduces uncertainty in soil volumes or indicates where sampling is required to reduce uncertainty, which together optimize remedial planning and budgeting. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗