Search NASA⌕ Search

SEARCH · Search NASA

Results for “Rotation operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Design and fabrication of the Brayton rotating unit

The Brayton rotating unit (BRU), operating on a gas bearing system, has been designed, fabricated, and demonstrated for use in a closed Brayton cycle space power conversion system. The BRU uses a binary mixture of xenon and helium (molecular weight, 83.8) as the cycle working fluid and bearing lubricating medium and was designed to produce from 2.25 to 10.5 kw sub e of 1200 Hz three-phase electrical power. The single-shaft rotating assembly operates at a design speed of 36,000 rpm and comprises a radial single-stage compressor, a four-pole Rice alternator rotor, and a radial inflow turbine. Four units, a dynamic simulator and three component research packages, were supplied to the NASA Lewis Research Center for performance testing and further development.

Davis, J. E.↗

Novel motor design for rotating anode x-ray tubes operating in the fringe field of a magnetic resonance imaging system

Purpose: Using hybrid x-ray/MR (XMR) systems for image guidance during interventional procedures could enhance the diagnosis and treatment of neurologic, oncologic, cardiovascular, and other disorders. The authors propose a close proximity hybrid system design in which a C-arm fluoroscopy unit is placed immediately adjacent to the solenoid magnet of a MR system with a minimum distance of 1.2 m between the x-ray and MR imaging fields of view. Existing rotating anode x-ray tube designs fail within MR fringe field environments because the magnetic fields alter the electron trajectories in the x-ray tube and act as a brake on the induction motor, reducing the rotation speed of the anode. In this study the authors propose a novel motor design that avoids the anode rotation speed reduction. Methods: The proposed design replaces the permanent magnet stator found in brushed dc motors with the radial component of the MR fringe field. The x-ray tube is oriented such that the radial component of the MR fringe field is orthogonal to the cathode-anode axis. Using a feedback position sensor and the support bearings as electrical slip rings, the authors use electrical commutation to eliminate the need for mechanical brushes and commutators. A vacuum compatible prototype of the proposed motor design was assembled, and its performance was evaluated at various operating conditions. The prototype consisted of a 3.1 in. diameter anode rated at 300 kHU with a ceramic rotor that was 5.6 in. in length and had a 2.9 in. diameter. The material chosen for all ceramic components was MACOR, a machineable glass ceramic developed by Corning Inc. The approximate weight of the entire assembly was 1750 g. The maximum rotation speed, angular acceleration, and acceleration time of the motor design were investigated, as well as the dependence of these parameters on rotor angular offset, magnetic field strength, and field orientation. The resonance properties of the authors' assembly were also evaluated to determine its stability during acceleration, and a pulse width modulation algorithm was implemented to control the rotation speed of the motor. Results: At a magnetic flux density of 41 mT orthogonal to the axis of rotation (on the lower end of the expected flux density in the MR suite) the maximum speed of the motor was found to be 5150 revolutions per minute (rpm). The acceleration time necessary to reach 3000 rpm was found to be approximately 10 s at 59 mT. The resonance frequency of the assembly with the anode attached was 1310 rpm (21.8 Hz) which is far below the desired operating speeds. Pulse width modulation provides an effective method to control the speed of the motor with a resolution of 100 rpm. Conclusions: The proposed design can serve as a direct replacement to the conventional induction motor used in rotating anode x-ray tubes. It does not suffer from a reduced rotation speed when operating in a MR environment. The presence of chromic steel bearings in the prototype prevented testing at the higher field strengths, and future iterations of the design could eliminate this shortcoming. The prototype assembly demonstrates proof of concept of the authors' design and overcomes one of the major obstacles for a MR compatible rotating anode x-ray tube.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent technology advances in the NASA-Lewis Research Center Brayton program

A review of the progress and milestones passed in the Brayton program is presented. The 2-to-15 kWe power system was successfully operated in a vacuum with a space-type radiator. Gas loop and electrical subsystem endurance tests have continued to demonstrate long-term operation with one rotating unit surpassing 10,000 hours of failure-free operation. Simplified gas-bearing designs for the rotating unit are being evaluated. Fabrication of an improved design of heat exchanger is nearing completion, and a study of more advanced heat exchanger technology is being conducted. A study was completed to investigate the applicability of Brayton technology applied to a lower power level (0.5 to 2.5 kWe) and showed potentially very attractive performance, simplicity, and low cost for a system in this power range.

Vernon, R.↗

Recent technology advances in the NASA-Lewis Research Center Brayton program.

A review of the progress and milestones passed in the Brayton program during the past year is presented. The 2-to-15 kWe power system was successfully operated in a vacuum with a space-type radiator. Gas loop and electrical subsystem endurance tests have continued to demonstrate long-term operation with one rotating unit surpassing 10,000 hours of failure-free operation. Simplified gas-bearing designs for the rotating unit are being evaluated. Fabrication of an improved design of heat exchanger is nearing completion, and a study of more advanced heat exchanger technology is being conducted.

Vernon, R.↗

Hydrodynamics and Load Shedding Behavior of a Variable-Geometry Oscillating Surge Wave Energy Converter (OSWEC)

In order to improve their long-term viability, wave energy converters (WECs) need to be able to shed loads when a threshold wave condition is exceeded. As shown by Tom et al. (2016) [1], provision of adjustable flaps within the body of an oscillating surge wave energy converter (OSWEC) allows wave energy to pass through the device. A control system may then be able to open and close the flaps when waves approaching the device exceed preset thresholds. The variable-geometry OSWEC (VG-OSWEC) concept studied in this paper is a bottom-hinged, rectangular wave paddle with five flaps of elliptical cross-section embedded into the face of the paddle. System ID tests were conducted on this VG-OSWEC device at a 1:14 scale in a wave basin. Free decay tests showed that the damping was distinctly nonlinear when the flaps were fully open, and the natural frequency increased by 40% when compared with the flaps in a fully closed configuration. Tests with regular wave conditions were used to develop the response amplitude operator for the rotational motion about the hinge. These response amplitude operator results when compared with numerical simulations run using WEC-Sim/WAMIT and ANSYS AQWA, show strong agreement with the flap open and closed conditions. The regular-wave condition measurements also show that the wave excitation moment about the hinge was reduced by up to 60% when the flaps were fully open. The experiments serve to demonstrate the potential of the variable geometry design to shed loads and survive harsh ocean environments.

load shedding↗

Effects of Inlet Area Ratio on Operability of an Axial Air Inlet Rotating Detonation Combustor

This research presents the first results from a new Rotating Detonation Combustor (RDC) design with an axial air inlet and rear-facing angled fuel injection. This design features a variable air inlet that allows for the study of the effect of inlet area ratio on operation and to directly study the coupling between the air plenum and channel of the RDC while minimizing inlet pressure losses. This device maintains the same downstream channel configuration as those previously tested in our laboratory, which includes a 154 mm outer channel diameter and a constant area channel with a width of 7.6 mm. All tests were completed with a downstream hydrogen-air afterburner capable of flashing back in the channel to initiate detonation operation. Initial tests demonstrated successful operation at air mass flow rates from 160 to 770 g/s and equivalence ratios from 0.53 to 1.05 at multiple air inlet to channel area ratios, indicated that sensors installed within the air feed plenum are able to characterize the dynamic characteristics of waves within the detonation channel, and verified that the design goals for this configuration were achieved.

Shepard, Joshua↗

Rotating odd-parity Lorentz invariance test in electrodynamics

We report the first operation of a rotating odd-parity Lorentz invariance test in electrodynamics using a microwave Mach-Zehnder interferometer with permeable material in one arm. The experiment sets a direct bound to {kappa}{sub tr} of -0.3{+-}3x10{sup -7}. Using new power recycled waveguide interferometer techniques (with the highest spectral resolution ever achieved of 2x10{sup -11} rad/{radical}(Hz)) we show an improvement of several orders of magnitude is attainable in the future.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Variations of (pseudo-)rotations and the Laplace-Beltrami operator on homogeneous spaces

In this paper we obtain the Lie derivatives of the scalar parameters in the generalized Euler decomposition with respect to arbitrary axes under left and right deck transformations. This problem can be directly related to the representation of the angular momentum in quantum mechanics. As a particular example, we calculate the angular momentum and the corresponding quantum hamiltonian in the standard Euler and Bryan representations. Similarly, in the hyperbolic case, the Laplace-Beltrami operator is retrieved for the Iwasawa decomposition. The case of two axes is considered as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quiet High Speed Fan II (22-inch) Duct Mode Characteristics as Measured by the Rotating Rake Mode Measurement System while Operated in the NASA Glenn 9x15 Low Speed Wind Tunnel

Wind Tunnel at a tunnel Mach number of 0.10. This was an entry to investigate the effect of “stator clocking” on noise. The fan consisted of a moderately aft swept rotor and an aft swept set of stator vanes. The fan stage consisted of 22 rotor blades, 50 stator vanes, and 10 downstream support struts. A set of stator vanes designed for lower noise was tested as well as a baseline stator vane set. The stator assembly could be rotated several degrees to adjust the clocking angle between the stator vane pack and the strut assembly. All configurations were with a hard wall duct (no acoustic treatment). The NASA Glenn Research Center’s Rotating Rake Mode Measurement System was utilized to obtain a complete map of the acoustic duct modes present in the ducted fan. The system is a radial rake emersed into the duct that continuously rotates about the duct centerline. For the two stator configurations, data were acquired at several different fan speeds which included nominal, approach, cutback, and takeoff conditions. Analysis of the mode power level results at the fan fundamentals showed the improved designed set resulted in lower rotor-stator and rotor-strut interaction acoustic levels for the interaction modes. Varying the angle between the stators and struts was shown to be a viable method to achieve a minimum in rotor-strut interaction mode power level. Multiple-pure-tones generated by the Quiet High Speed Fan II in the inlet were also measured.

Turbofan, Duct Modes↗

Quiet High Speed Fan II (22-inch) Duct Mode Characteristics as Measured by the Rotating Rake Mode Measurement System while Operated in the NASA Glenn 9x15 Low Speed Wind Tunnel

Wind Tunnel test at a tunnel Mach number of 0.10. This was an entry to investigate the effect of “stator clocking” on noise. The fan consisted of a moderately aft swept rotor and an aft swept set of stator vanes. The fan stage consisted of 22 rotor blades, 50 stator vanes, and 10 downstream support struts. A set of stator vanes designed for lower noise was tested as well as a baseline stator vane set. The stator assembly could be rotated several degrees to adjust the clocking angle between the stator vane pack and the strut assembly. All configurations were with a hard wall duct (no acoustic treatment). The NASA Glenn Research Center’s Rotating Rake Mode Measurement System was utilized to obtain a complete map of the acoustic duct modes present in the ducted fan. The system is a radial rake emersed into the duct that continuously rotates about the duct centerline. For the two stator configurations, data were acquired at several different fan speeds which included nominal, approach, cutback, and takeoff conditions. Analysis of the mode power level results at the fan fundamentals showed the improved designed set resulted in lower rotor-stator and rotor-strut interaction acoustic levels for the interaction modes. Varying the angle between the stators and struts was shown to be a viable method to achieve a minimum in rotor-strut interaction mode power level. Multiple-pure-tones generated by the Quiet High Speed Fan II in the inlet were also measured.

Turbofan, Duct Modes↗

Source Diagnostic Fan II (22-Inch) Duct Mode Characteristics as Measured by the Rotating Rake Mode Measurement System while Operated in the NASA Glenn 9x15 Low Speed Wind Tunnel

A 22-inch scale model of the Honeywell Quiet High Speed Fan II was tested in the NASA Glenn 9- by 15-foot Low Speed Wind Tunnel at a tunnel Mach number of 0.10. This was an entry to investigate the effect of “stator clocking” on noise. The fan consisted of a moderately aft swept rotor, and an aft swept set of stator vanes. The fan stage consisted of 22 rotor blades, 50 stator vanes, and 10 downstream support struts. A set of stator vanes designed for lower noise was tested as well as a baseline stator vane set. The stator assembly could be rotated several degrees to adjust the clocking angle between the stator vane pack and the strut assembly. All configurations were with a hard wall duct (no acoustic treatment). The NASA Glenn Research Center’s Rotating Rake Mode Measurement System was utilized to obtain a complete map of the acoustic duct modes present in the ducted fan. The system is a radial rake emersed into the duct that continuously rotates about the duct centerline. For the two stator configurations, data were acquired at several different fan speeds which included nominal, approach, cutback, and takeoff conditions. Analysis of the mode power level results at the fan fundamentals showed the improved designed set resulted in lower rotor-stator and rotor-strut interaction acoustic levels for the interaction modes. Varying the angle between the stators and struts was shown to be a viable method to achieve a minimum in rotor-strut interaction mode power level. Multiple-pure-tones generated by the Quiet High Speed Fan II in the inlet were also measured.

Fan Noise↗

Source Diagnostic Fan II (22-inch) Duct Mode Characteristics as Measured by the Rotating Rake Mode Measurement System while Operated in the NASA Glenn 9x15 Low Speed Wind Tunnel

The second entry of the Source Diagnostic Test (SDT2) was a continuation of the first SDT entry with additional parameters tested. The rotor, stators, and general flow path hardware used in SDT2 were the same as those for SDT1. This included a radial baseline set of stator vanes, which had a vane count such that the rotor-stator interaction at the fan blade passing fundamental was cut-off, as is typical for modern turbofans. Two sets of stator vanes were designed and tested with a count generating a cut-on rotor-stator interaction at the fan blade passing fundamental. One of the sets maintained the no aerodynamic sweep as the radial baseline, the other was designed with leading edge sweep with the intent to generate lower noise. The NASA Glenn Research Center’s Rotating Rake Mode Measurement System was utilized to obtain a complete map of the acoustic duct modes present. The system is a radial rake immersed into the duct that continuously rotates about the duct centerline. For each of the three stator vane configurations, data were acquired at several different fan speeds which included nominal, approach, cutback, and takeoff conditions. Analysis of the mode power level results at the fan fundamentals showed the improved designed set resulted in lower rotor-stator interaction mode acoustic levels. Multiple-pure tones generated by the M5 rotor in the inlet were also measured.

Turbofan, Duct Modes↗

Source Diagnostic Fan II (22-inch) Duct Mode Characteristics as Measured by the Rotating Rake Mode Measurement System while Operated in the NASA Glenn 9x15 Low Speed Wind Tunnel

The second entry of the Source Diagnostic Test (SDT2) was a continuation of the first SDT entry with additional parameters tested. The rotor, stators, and general flow path hardware used in SDT2 were the same as those for SDT1. This included a radial baseline set of stator vanes, which had a vane count such that the rotor-stator interaction at the fan blade passing fundamental was cut-off, as is typical for modern turbofans. Two sets of stator vanes were designed and tested with a count generating a cut-on rotor-stator interaction at the fan blade passing fundamental. One of the sets maintained the no aerodynamic sweep as the radial baseline, the other was designed with leading edge sweep with the intent to generate lower noise. The NASA Glenn Research Center’s Rotating Rake Mode Measurement System was utilized to obtain a complete map of the acoustic duct modes present. The system is a radial rake emersed into the duct that continuously rotates about the duct centerline. For each of the three stator vane configurations, data were acquired at several different fan speeds which included nominal, approach, cutback, and takeoff conditions. Analysis of the mode power level results at the fan fundamentals showed the improved designed set resulted in lower rotor-stator interaction mode acoustic levels. Multiple-pure tones generated by the M5 rotor in the inlet were also measured.

Turbofan↗

The fluid dynamic and shear environment in the NASA/JSC rotating-wall perfused-vessel bioreactor

The rotating-wall perfused-vessel (RWPV) bioreactor, used for both microgravity and Earth-based cell science experiments, is characterized in terms of the fluid dynamic and fluid shear stress environment. A numerical model of the flow field is developed and verified with laser Doppler velocimeter measurements. The effects of changes in operating conditions, including rotation rates and fluid perfusion rates, are investigated with the numerical model. The operating conditions typically used for ground-based experiments (equal rotation of the inner and outer cylinders) leads to flow patterns with relatively poor mass distribution characteristics. Approximately 50% of the inlet-perfused fluid bypasses the bulk of the fluid volume and flows to the perfusion exit. For operating conditions typical in microgravity, small differential rotation rates between the inner and outer cylinders lead to greatly improved flow distribution patterns and very low fluid shear stress levels over a large percentage of the fluid volume. Differences in flow patterns for the different operating conditions are explored. Large differences in the hydrodynamic environments for operating conditions typical of true microgravity and ground-based "microgravity simulations" are demonstrated.

Bioreactors↗

Variable force, eddy-current or magnetic damper

An object of the invention is to provide variable damping for resonant vibrations which may occur at different rotational speeds in the range of rpms in which a rotating machine is operated. A variable force damper in accordance with the invention includes a rotating mass carried on a shaft which is supported by a bearing in a resilient cage. The cage is attached to a support plate whose rim extends into an annular groove in a housing. Variable damping is effected by tabs of electrically conducting nonmagnetic material which extend radially from the cage. The tabs at an index position lie between the pole face of respective C shaped magnets. The magnets are attached by cantilever spring members to the housing.

Cunningham, R. E.↗

A Mobile Automated Tomographic Gamma Scanning System - 13231

Canberra Industries have recently designed and built a new automated Tomographic Gamma Scanning (TGS) system for mobile deployment. The TGS technique combines high-resolution gamma spectroscopy with low spatial resolution 3-dimensional image reconstruction to provide increased accuracy over traditional approaches for the assay of non-uniform source distributions in low-to medium-density, non-heterogeneous matrices. Originally pioneered by R. Estep at Los Alamos National Laboratory (LANL), the TGS method has been further developed and commercialized by Canberra Industries in recent years. The present system advances the state of the art on several fronts: it is designed to be housed in a standard cargo transport container for ease of transport, allowing waste characterization at multiple facilities under the purview of a single operator. Conveyor feed, drum rotator, and detector and collimator positioning mechanisms operated by programmable logic control (PLC) allow automated batch mode operation. The variable geometry settings can accommodate a wide range of waste packaging, including but not limited to standard 220 liter drums, 380 liter overpack drums, and smaller 20 liter cans. A 20 mCi Eu-152 transmission source provides attenuation corrections for drum matrices up to 1 g/cm{sup 3} in TGS mode; the system can be operated in Segmented Gamma Scanning (SGS) mode to measure higher density drums. To support TGS assays at higher densities, the source shield is sufficient to house an alternate Co-60 transmission source of higher activity, up to 250 mCi. An automated shutter and attenuator assembly is provided for operating the system with a dual intensity transmission source. The system's 1500 kg capacity rotator turntable can handle heavy containers such as concrete lined 380 liter overpack drums. Finally, data acquisition utilizes Canberra's Broad Energy Germanium (BEGE) detector and Lynx MCA, with 32 k channels, providing better than 0.1 keV/channel resolution to support both isotopic analysis with the MGA/MGAU software and a wide 3 MeV dynamic range. The calibration and verification of the system is discussed, and quantitative results are presented for a variety of drum types and matrices. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pseudo-merohedral twinning and noncrystallographic symmetry in orthorhombic crystals of SIVmac239 Nef core domain bound to different-length TCRζ fragments

P2{sub 1}2{sub 1}2{sub 1} crystals of SIV Nef core domain bound to a peptide fragment of the T-cell receptor ζ subunit exhibited noncrystallographic symmetry and nearly perfect pseudo-merohedral twinning simulating tetragonal symmetry. For a different peptide fragment, nontwinned tetragonal crystals were observed but diffracted to lower resolution. The structure was determined after assignment of the top molecular-replacement solutions to various twin or NCS domains followed by refinement under the appropriate twin law. HIV/SIV Nef mediates many cellular processes through interactions with various cytoplasmic and membrane-associated host proteins, including the signalling ζ subunit of the T-cell receptor (TCRζ). Here, the crystallization strategy, methods and refinement procedures used to solve the structures of the core domain of the SIVmac239 isolate of Nef (Nef{sub core}) in complex with two different TCRζ fragments are described. The structure of SIVmac239 Nef{sub core} bound to the longer TCRζ polypeptide (Leu51–Asp93) was determined to 3.7 Å resolution (R{sub work} = 28.7%) in the tetragonal space group P4{sub 3}2{sub 1}2. The structure of SIVmac239 Nef{sub core} in complex with the shorter TCRζ polypeptide (Ala63–Arg80) was determined to 2.05 Å resolution (R{sub work} = 17.0%), but only after the detection of nearly perfect pseudo-merohedral crystal twinning and proper assignment of the orthorhombic space group P2{sub 1}2{sub 1}2{sub 1}. The reduction in crystal space-group symmetry induced by the truncated TCRζ polypeptide appears to be caused by the rearrangement of crystal-contact hydrogen-bonding networks and the substitution of crystallographic symmetry operations by similar noncrystallographic symmetry (NCS) operations. The combination of NCS rotations that were nearly parallel to the twin operation (k, h, −l) and a and b unit-cell parameters that were nearly identical predisposed the P2{sub 1}2{sub 1}2{sub 1} crystal form to pseudo-merohedral twinning.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Flight tests of a rotating cylinder flap on a North American Rockwell YOV-10 aircraft

Flight tests were conducted of a twin engine airplane modified to a STOL configuration with rotating cylinder flaps and interconnected propellers. The flight tests included verification of the functional operation of the rotating cylinder flap system and the determination of the low speed flying qualities and performance characteristics with emphasis on approach and landing.

Cichy, D. R.↗