Search NASA⌕ Search

SEARCH · Search NASA

Results for “SHIFT REGISTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Changes in the energy spectrum of anomalous oxygen during 1977-1985

Spatial and temporal variations of the interplanetary cosmic ray oxygen spectrum over the 11 yr solar and cosmic ray modulation cycle are discussed. The variations were monitored with instrumentation on the Voyager 1 and 2 and the Pioneer 10 spacecraft over the period 1977-85. The analysis concentrates on 4-30 MeV nuclei, where the anomalous component of cosmic rays dominates. The number of particles of anomalous oxygen increased with increasing distance from the sun. Furthermore, the particles exhibited, on the average, higher energies after the middle of 1980, when a solar magnetic field reversal occurred. The Voyager 1 spacecraft, 24 deg out of the ecliptic plane, did not register as high a shift in energy during the same period. It is concluded that cosmic ray drift effects are closely associated with solar magnetic field polarity reversals, a situation which may be examined more fully during the solar minimum beginning in 1985.

Cummings, A. C.↗

Design, development, fabrication and delivery of register and multiplexer units

Several approaches for implementing the register and multiplexer unit into two CMOS monolithic chip types were evaluated. The CMOS standard cell array technique was selected and implemented. Using this design automation technology, two LSI CMOS arrays were designed, fabricated, packaged, and tested for proper static, functional, and dynamic operation. One of the chip types, multiplexer register type 1, is fabricated on a 0.143 x 0.123 inch chip. It uses nine standard cell types for a total of 54 standard cells. This involves more than 350 transistors and has the functional equivalent of 111 gates. The second chip, multiplexer register type 2, is housed on a 0.12 x 0.12 inch die. It uses 13 standard cell types, for a total of 42 standard cells. It contains more than 300 transistors, the functional equivalent of 112 gates. All of the hermetically sealed units were initially screened for proper functional operation. The static leakage and the dynamic leakage were measured. Dynamic measurements were made and recorded. At 10 V, 14 megabit shifting rates were measured on multiplexer register type 1. At 5 V these units shifted data at a 6.6 MHz rate. The units were designed to operate over the 3 to 15 V operating range and over a temperature range of -55 to 125 C.

Feller, A.↗

Airborne Doppler-lidar and ground-based Doppler radar observations of a thunderstorm in Oklahoma

The results of airborne Doppler-lidar and ground-based Doppler radar observations of multicellular storms, marked by heavy rainfall, strong surface outflow, and a gust-front tornado, on June 30, 1981 are analyzed. The airborne lidar comprised a CO2-laser operating in the IR region, which was discharged once each second at 20 deg fore and aft, alternatively, of the normal to the aircraft's heading, and a quarter-wave plate for registering the returning frequency-shifted beams. Wind fields are plotted taking into account the advection effects. The lidar data set is noted for its self-consistency, though limited to a range of 5 km by the high moisture levels. Fair agreement was found between the lidar-derived and radar-derived average ground-based radial wind fields, with discrepancies on the order of 1.5 m/s.

Bluestein, H. B.↗

Efficacy of Compression Garments to Simulate Fluid Shifts during Lunar Bedrest

The effectiveness of JOBST(Registered TradeMark) compression stockings for fluid redistribution was examined in the lunar bed rest analog based on Digital Astronaut computer model predictions. NASA's future goals include missions to the moon which will require extended exposure to the lunar gravity environment. To prepare for these missions, physiological adaptations in various systems must be resolved. A bed rest at a 10 degree head-up tilt was used to simulate lunar gravity. Plasma volume (PV) loss may cause some of the cardiovascular adaptations which occur during space flight so PV is measured in the bed rest analog to evaluate fluid loss. PV varies from individual to individual so PV index (PVI) is used to determine the magnitude and time course of fluid shift and cardiovascular adaptation to 1/6 g. The Digital Astronaut, a computer simulation tool, predicts a 6% PV loss during an extended simulated lunar mission for a male with a body surface area of 1.95 m(exp 2). Simple geometry calculations suggest that 10 degree head-up tilt is most useful for simulated measurement of deconditioning in bone and muscle, however, 2 degree head-up tilt may best imitate cardiovascular fluid shifts. In order to reconcile these different models, compression stocking must be used in the 10 degree paradigm to better approximate expected cardiovascular changes.

Brinley, Alaina↗

The Effect of Acoustic Disturbances on the Operation of the Space Shuttle Main Engine Fuel Flowmeter

The Space Shuttle Main Engine (SSME) uses a turbine fuel flowmeter (FFM) in its Low Pressure Fuel Duct (LPFD) to measure liquid hydrogen flowrates during engine operation. The flowmeter is required to provide accurate and robust measurements of flow rates ranging from 10000 to 18000 GPM in an environment contaminated by duct vibration and duct internal acoustic disturbances. Errors exceeding 0.5% can have a significant impact on engine operation and mission completion. The accuracy of each sensor is monitored during hot-fire engine tests on the ground. Flow meters which do not meet requirements are not flown. Among other parameters, the device is screened for a specific behavior in which a small shift in the flow rate reading is registered during a period in which the actual fuel flow as measured by a facility meter does not change. Such behavior has been observed over the years for specific builds of the FFM and must be avoided or limited in magnitude in flight. Various analyses of the recorded data have been made prior to this report in an effort to understand the cause of the phenomenon; however, no conclusive cause for the shift in the instrument behavior has been found. The present report proposes an explanation of the phenomenon based on interactions between acoustic pressure disturbances in the duct and the wakes produced by the FFM flow straightener. Physical insight into the effects of acoustic plane wave disturbances was obtained using a simple analytical model. Based on that model, a series of three-dimensional unsteady viscous flow computational fluid dynamics (CFD) simulations were performed using the MSFC PHANTOM turbomachinery code. The code was customized to allow the FFM rotor speed to change at every time step according to the instantaneous fluid forces on the rotor, that, in turn, are affected by acoustic plane pressure waves propagating through the device. The results of the simulations show the variation in the rotation rate of the flowmeter due to the interaction of the flow straightener wakes and the upstream propagating acoustic waves. A detailed analysis of the acoustic disturbance effects is presented along with an assessment of the impact on measurement accuracy.

Marcu, Bogdan↗

Automatic oscillator frequency control system

A frequency control system makes an initial correction of the frequency of its own timing circuit after comparison against a frequency of known accuracy and then sequentially checks and corrects the frequencies of several voltage controlled local oscillator circuits. The timing circuit initiates the machine cycles of a central processing unit which applies a frequency index to an input register in a modulo-sum frequency divider stage and enables a multiplexer to clock an accumulator register in the divider stage with a cyclical signal derived from the oscillator circuit being checked. Upon expiration of the interval, the processing unit compares the remainder held as the contents of the accumulator against a stored zero error constant and applies an appropriate correction word to a correction stage to shift the frequency of the oscillator being checked. A signal from the accumulator register may be used to drive a phase plane ROM and, with periodic shifts in the applied frequency index, to provide frequency shift keying of the resultant output signal. Interposition of a phase adder between the accumulator register and phase plane ROM permits phase shift keying of the output signal by periodic variation in the value of a phase index applied to one input of the phase adder.

Smith, S. F.↗

A fast-reacting and versatile optokinetic stimulus pattern by computer graphics with application examples

A computer graphics method for the generation of horizontally moving vertical stripes which serve as stimuli for optokinetic nystagmus is presented. The pattern is generated by the successive addition of a constant in a digital register, leading to its periodic overflow. Digital to analog conversion of the register contents results in a staircase waveform, which is converted into a pattern of vertical lines on a CRT. The addition of any number to the reference buffer shifts all lines uniformly, so that the group velocity of the pattern is easily controlled. The computer controlled display allows an accurate realization of a commanded velocity profile with practically no time delay and facilitates study under conditions of variable feedback. The display software can be easily modified to limit stimulation to a selected area of the moving retina, and the method has been used to simulate central scotomata. It is pointed out that the technique, while more accurate, versatile and responsive than a rotating drum device, may be less useful in experiments requiring a wide field display.

Yasui, S.↗

Avoiding Stair-Step Artifacts in Image Registration for GOES-R Navigation and Registration Assessment

In developing software for independent verification and validation (IVV) of the Image Navigation and Registration (INR) capability for the Geostationary Operational Environmental Satellite R Series (GOES-R) Advanced Baseline Imager (ABI), we have encountered an image registration artifact which limits the accuracy of image offset estimation at the subpixel scale using image correlation. Where the two images to be registered have the same pixel size, subpixel image registration preferentially selects registration values where the image pixel boundaries are close to lined up. Because of the shape of a curve plotting input displacement to estimated offset, we call this a stair-step artifact. When one image is at a higher resolution than the other, the stair-step artifact is minimized by correlating at the higher resolution. For validating ABI image navigation, GOES-R images are correlated with Landsat-based ground truth maps. To create the ground truth map, the Landsat image is first transformed to the perspective seen from the GOES-R satellite, and then is scaled to an appropriate pixel size. Minimizing processing time motivates choosing the map pixels to be the same size as the GOES-R pixels. At this pixel size image processing of the shift estimate is efficient, but the stair-step artifact is present. If the map pixel is very small, stair-step is not a problem, but image correlation is computation-intensive. This paper describes simulation-based selection of the scale for truth maps for registering GOES-R ABI images.

stair-step artifact↗

Avoiding Stair-Step Artifacts in Image Registration for GOES-R Navigation and Registration Assessment

In developing software for independent verification and validation (IVV) of the Image Navigation and Registration (INR) capability for the Geostationary Operational Environmental Satellite R Series (GOES-R) Advanced Baseline Imager (ABI), we have encountered an image registration artifact which limits the accuracy of image offset estimation at the subpixel scale using image correlation. Where the two images to be registered have the same pixel size, subpixel image registration preferentially selects registration values where the image pixel boundaries are close to lined up. Because of the shape of a curve plotting input displacement to estimated offset, we call this a stair-step artifact. When one image is at a higher resolution than the other, the stair-step artifact is minimized by correlating at the higher resolution. For validating ABI image navigation, GOES-R images are correlated with Landsat-based ground truth maps. To create the ground truth map, the Landsat image is first transformed to the perspective seen from the GOES-R satellite, and then is scaled to an appropriate pixel size. Minimizing processing time motivates choosing the map pixels to be the same size as the GOES-R pixels. At this pixel size image processing of the shift estimate is efficient, but the stair-step artifact is present. If the map pixel is very small, stair-step is not a problem, but image correlation is computation-intensive. This paper describes simulation-based selection of the scale for truth maps for registering GOES-R ABI images.

image registration↗

Functional Data Analysis of Spaceflight-Induced Changes in Coordination and Phase in Head Pitch Acceleration During Treadmill Walking

Astronauts returning from spaceflight experience neurovestibular disturbances during head movements and attempt to mitigate them by limiting head motion. Analyses to date of the head movements made during walking have concentrated on amplitude and variability measures extracted from ensemble averages of individual gait cycles. Phase shifts within each gait cycle can be determined by functional data analysis through the computation of time-warping functions. Large, localized variations in the timing of peaks in head kinematics may indicate changes in coordination. The purpose of this study was to determine timing changes in head pitch acceleration of astronauts during treadmill walking before and after flight. Six astronauts (5M/1F; age = 43.5+/-6.4yr) participated in the study. Subjects walked at 1.8 m/sec (4 mph) on a motorized treadmill while reading optotypes displayed on a computer screen 4 m in front of their eyes. Three-dimensional motion of the subject s head was recorded with an Inertial Measurement Unit (IMU) device. Data were recorded twice before flight and four times after landing. The head pitch acceleration was calculated by taking the time derivative of the pitch velocity data from the IMU. Data for each session with each subject were time-normalized into gait cycles, then registered to align significant features and create a mean curve. The mean curves of each postflight session for each subject were re-registered based on their preflight mean curve to create time-warping functions. The root mean squares (RMS) of these warping functions were calculated to assess the deviation of head pitch acceleration mean curves in each postflight session from the preflight mean curve. After landing, most crewmembers exhibited localized shifts within their head pitch acceleration regimes, with the greatest deviations in RMS occurring on landing day or 1 day after landing. These results show that the alteration of head pitch coordination due to spaceflight may be assessed using an analysis of time-warping functions.

Miller, Christopher↗

MatchGUI: A Graphical MATLAB-Based Tool for Automatic Image Co-Registration

MatchGUI software, based on MATLAB, automatically matches two images and displays the match result by superimposing one image on the other. A slider bar allows focus to shift between the two images. There are tools for zoom, auto-crop to overlap region, and basic image markup. Given a pair of ortho-rectified images (focused primarily on Mars orbital imagery for now), this software automatically co-registers the imagery so that corresponding image pixels are aligned. MatchGUI requires minimal user input, and performs a registration over scale and inplane rotation fully automatically

Ansar, Adnan I.↗

Analysis by NASA's VESGEN Software of Retinal Blood Vessels in Human Subjects Undergoing Head-Down Tilt During 70-Day Bed Rest

Significant risks for visual impairment associated with increased intracranial pressure (VIIP) are incurred by microgravity spaceflight, especially long-duration missions [1]. We hypothesize that microgravity-induced fluid shifts result in pathological changes within blood vessels of the retina that precede development of visual and other ocular impairments. Potential contributions of retinal vascular remodeling to VIIP etiology are therefore being investigated for two studies in 30deg infrared (IR) Heidelberg Spectralis(Registered Trademark) images with NASA's innovative VESsel GENeration Analysis (VESGEN) software [2,3]. The retrospective studies include: (1) before, during and after (pre, mid and post) 6º head-down tilt (HDT) in human subjects during 70 days of bed rest, and (2) before and after missions to the International Space Station (ISS) by U.S. crew members. Results for both studies are almost complete. A preliminary example for HDT is described below.

Microgravity↗

Massively parallel processor computer

An apparatus for processing multidimensional data with strong spatial characteristics, such as raw image data, characterized by a large number of parallel data streams in an ordered array is described. It comprises a large number (e.g., 16,384 in a 128 x 128 array) of parallel processing elements operating simultaneously and independently on single bit slices of a corresponding array of incoming data streams under control of a single set of instructions. Each of the processing elements comprises a bidirectional data bus in communication with a register for storing single bit slices together with a random access memory unit and associated circuitry, including a binary counter/shift register device, for performing logical and arithmetical computations on the bit slices, and an I/O unit for interfacing the bidirectional data bus with the data stream source. The massively parallel processor architecture enables very high speed processing of large amounts of ordered parallel data, including spatial translation by shifting or sliding of bits vertically or horizontally to neighboring processing elements.

Fung, L. W.↗

Differential, integral, and momentum-transfer cross sections for elastic electron scattering by neon - 5 to 100 eV

Relative elastic-scattering differential cross sections were measured in the 5-100-eV impact energy and 10-145 deg angular ranges. Normalization of these cross sections was achieved by utilizing accurate total electron-scattering cross sections. A phase-shift analysis of the angular distributions in terms of real phase shifts has been carried out. From the differential cross sections, momentum-transfer cross sections were obtained and the values of the critical energy and angle were established (associated with the lowest value of the differential cross section) as 62.5 + or - 2.5 eV and 101.7 deg + or - 1.5 deg, respectively. The present phase shifts, the critical parameters, and differential, integral, and momentum-transfer cross sections are compared to previous experimental and theoretical results. The error associated with the present data is about 10 percent.

Register, D. F.↗

Absolute elastic differential electron scattering cross sections for He - A proposed calibration standard from 5 to 200 eV

Absolute differential, integral, and momentum-transfer cross sections for electrons elastically scattered from helium are reported for the impact energy range of 5 to 200 eV. Angular distributions for elastically scattered electrons are measured in a crossed-beam geometry using a collimated, differentially pumped atomic-beam source which requires no effective-path-length correction. Below the first inelastic threshold the angular distributions were placed on an absolute scale by use of a phase-shift analysis. Above this threshold, the angular distributions from 10 to 140 deg were fitted using the phase-shift technique, and the resulting integral cross sections were normalized to a semiempirically derived integral elastic cross section. Depending on the impact energy, the data are estimated to be accurate to within 5 to 9%.

Register, D. F.↗

Coupling functions for lead and lead-free neutron monitors from the latitudinal measurements performed in 1982 in the research station Academician Kurchatov

The latitudinal behavior of intensities and multiplicities was registered by the neutron monitor 2 NM and the lead-free neutron monitor 3 SND (slow-neuron detector) in the equator-Kaliningrad line in the Atlantic Ocean. Coupling coefficients for 3 SND show the sensitivity of this detector to primary particles of cosmic rays of energies on the average lower than for 2 NM. As multiplicities increase, the coupling coefficients shift towards higher energies.

Alekanyan, T. M.↗

Effects of High-Temperature Exposures on the Fatigue Life of Superalloy Udimet(Registered Trademark) 720

The purpose of this study was to examine the effects of extended exposures on the near-surface fatigue resistance of a disk superalloy. Powder metallurgy processed, supersolvus heat-treated Udimet 720 (U720) fatigue specimens were exposed in air at temperatures from 650 to 705 C for 100 hr to over 1000 hr. They were then tested using conventional fatigue tests at 650 C to determine the effects of exposure on fatigue resistance. The exposures reduced life by up to 70% and increased the scatter in life, compared to unexposed levels. Fractographic evaluations indicated the failure mode was shifted by the exposures from internal to surface crack initiations. The increased scatter in life was related to the competition between internal crack initiations at inclusions or large grains producing longer lives, and surface crack initiations at an environmentally affected surface layer producing shorter lives.

Gabb, Timothy P.↗

Discovery of 69 ms periodic X-ray pulsations in A0538-66

The detection of X ray pulsations with a period of 69.2126 ms from A0538-66 was done from the Einstein Observatory. A point source was located by the High Resolution Imager and a proportional counter registered a flux of 40 counts/sec over background. A column spectral density of 2 x 10 to the 23/sq cm identified the object as A0538-66. A persistent periodicity of 0.0692126 sec was observed throughout the event. The outbursts were not detected on three other observations of A0538-66, and a best fit to a change of rotation velocity indicated that the period observed was from a binary star with a Doppler shifted signal. The two stars are separated by less than 39 solar radii, with the larger star having a 40 solar radius. Consideration is given to the possibility that the X rays are due to accretion on a neutron star and that the two stars at times share a common envelope.

Skinner, G. K.↗