Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL-TO-NOISE RATIO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Cross Correlating the Unresolved Gamma-Ray Background with Cosmic Large-Scale Structure from DESI: Implications for Astrophysics and Dark Matter

The unresolved gamma-ray background (UGRB) is a diffuse gamma-ray emission arising from numerous extragalactic sources below the detection threshold and is an important component of the gamma-ray sky. Studying the UGRB is crucial for understanding high-energy astrophysical processes in the universe and for probing fundamental physics, such as the nature of dark matter. In this work, we forecast the cross-correlation between the UGRB and galaxy catalogs from the Dark Energy Spectroscopic Instrument (DESI) survey. First, we study the expected astrophysical contributions to the UGRB and their cross-correlation with DESI spectroscopic galaxies. Our calculations show that the cross-correlation signal-to-noise ratio is expected to be significant, with the highest value predicted to be 20.6 for DESI luminous red galaxies due to a higher predicted overlap in the redshift distribution with the UGRB. We consider two science cases that the UGRB-spectroscopic galaxies cross-correlation can be applied to: 1) measuring the UGRB flux as a function of redshift, achieving a precision of 10% in some redshift bins, and 2) searching for annihilating dark matter potentially up to a mass of about 300~GeV, three times higher than the currently strongest constraints. This work underscores the importance of cross correlating the UGRB with cosmic large-scale structure tracers and highlights the multiwavelength approaches to advancing our understanding of high-energy astrophysical phenomena and fundamental physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Co-existence of Heterogeneous Wireless Networks in 2.4 GHz and 5 GHz Spectrum

To achieve automation across different applications, next-generation nuclear power plants are beginning to leverage advanced wireless technologies. The deployment of these wireless technologies is a salient need for modernizing the existing nuclear plants. A “one-size-fits-all” solution cannot be adopted since wireless technologies are selected according to specific application needs, quality of service, and economic restrictions. To balance the trade-off between technical and economic requirements, a multi-band heterogeneous wireless network architecture is needed. However, the co-existence of these multi-band wireless technologies poses numerous challenges. Due to factors including dissimilarity in channel access mechanisms, transmit power levels, distance between nodes, and interference among co-existing solutions, performance can be seriously degraded, leading to very low signal-to-noise ratio. This report builds on our previous study, "Experimental Evaluation of Interference in 2.4 GHz Wireless Network," which analyzed the performance of wireless communication technologies such as Wi-Fi, Zigbee, and Bluetooth co-existing within the 2.4 GHz band. We now extend this study by developing a new upper-layer approach that uses rate control to create temporary opportunities for signal transmission while using the shared band. Unlike existing work in the literature, our approach does not require modifications at the link or physical layers of the network. Further, we extend our work to explore the co-existence of Wi-Fi and fifth-generation (5G) in the 5 GHz unlicensed spectrum, using both experiments and simulations. This report provides a technical foundation for understanding the operational designs of Wi-Fi and 5G in the unlicensed band and evaluates their performance when these networks co-exist. Our findings show that the performance of 5G can be improved by controlling the Wi-Fi’s packet rate at the upper layer.

42 ENGINEERING↗

The Composite Spectrum of QSO Absorption Line Systems in DESI DR2

We present details regarding the construction of a composite spectrum of quasar (QSO) absorption line systems. In this composite spectrum we identify more than 70 absorption lines, and observe oxygen and hydrogen emission features at a higher signal-to-noise ratio than in any previous study. As the light from a distant quasar travels towards an observer, it may interact with the circumgalactic medium environment of an intervening galaxy, forming absorption lines. In order to maximize the signal of these absorption lines, we have selected a sample of 238,838 quasar spectra from the second data release of the Dark Energy Spectroscopic Instrument (DESI), each identified to have absorption lines resulting from such an interaction. By stacking these spectra in the restframe of the absorption, and calculating a median composite spectrum, we are able to isolate and enhance these absorption lines. We provide a full atlas of all detected absorption and emission lines as well as their fit centroids and equivalent width values. This atlas should aid in future studies investigating the compositions and physical conditions of these absorbers.

Napolitano, Lucas [Wyoming U.] (ORCID:000000025166↗

Detecting Process Equipment Failures Using Acoustic Data and Machine Learning

Nuclear power plant (NPP) process equipment such as fans, motors, valves, and pumps generate frequent or continuous noise, and deviations from the normal operational sounds made by this equipment can indicate potential issues. These deviations can be identified via automated acoustic anomaly detection, which involves using acoustic sensors (i.e., microphones) alongside detection algorithms to continuously monitor for changes in acoustic signatures. This task is made challenging by the substantial background noise that exists, such as operators opening and closing doors, manipulating valves, and conversing—in addition to typical plant noises. In collaboration with a nuclear power utility partner, this effort assessed the efficacy of acoustic anomaly detection when using a specific acoustic sensor that compresses data into a fixed set of features that are transferable over a standard Internet of Things communication protocol, thereby improving usability but potentially degrading detection performance. Two methods of performing automated acoustic anomaly detection were evaluated: one-class support vector machine (OC-SVM) and isolation forest (iForest). To enable the use of high-quality acoustic data encompassing both normal and anomalous conditions, the study utilized the publicly available Malfunctioning Industrial Machine Investigation and Inspection dataset, which includes real measured acoustic sensor data for a range of equipment types, model numbers, and signal-to-noise ratios (SNRs), along with a benchmark set of detection results. Using this dataset, the methods were tested and then compared against the benchmark results. The results indicated that although the specific acoustic sensor did not enable as rich a feature set extraction, the proposed methods with the limited feature set performed just as well. This provides solid justification for both the methods and the use of the proposed acoustic sensor.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Precision Kinematic Sunyaev--Zel'dovich Measurements Across Halo Mass and Redshift with DESI DR2 and ACT DR6: Part II. Bright Galaxy Survey and Emission-Line Galaxies

We present the first high-significance spectroscopic stacked kinetic Sunyaev-Zel'dovich (kSZ) measurements of circumgalactic gas profiles for both Bright Galaxy Survey (BGS) and Emission Line Galaxy (ELG) tracers, combining DESI Data Release 2 with ACT Data Release 6. Using reconstructed line-of-sight velocities from the DESI galaxies and high-resolution ACT temperature maps, we detect the kSZ signal at high significance, reaching signal-to-noise ratios of up to $\sim$9 for BGS and $\sim$7.5 for ELGs in optimal stellar-mass selections. Together with the LRG measurements presented in Paper I, these constitute the most significant kSZ detections from any spectroscopic survey to date. We perform the analysis in both real and harmonic space, obtaining consistent results. By splitting both tracers into stellar-mass bins, we study the scaling of the kSZ amplitude with galaxy properties. Combining the kSZ measurements with ACT Data Release 6 (DR6) CMB lensing maps enables a joint calibration of the galaxy-halo connection and the gas fractions of host halos. For the BGS galaxies, we observe low gas fractions around the virial radius relative to standard expectations, likely attributable to active galactic nuclei (AGN) activity. We find some evidence for higher-mass halos retaining a larger fraction of their baryons, consistent with more efficient feedback in lower-mass systems. For the ELG sample, dominated by blue, star-forming galaxies, we provide the first detection of the gas distribution in ELG host halos. The ELGs appear to exhibit relatively high gas fractions, which points to the possibility of weaker feedback (due to e.g. low AGN and supernova feedback activity) at their mass scale. Finally, we present generalized Navarro-Frenk-White (GNFW) fits to the harmonic-space measurements, providing a compact parametrization of gas profiles for forward modeling in large-scale structure analyses.

Hadzhiyska, B. [Cambridge U.; Cambridge U., Inst. ↗

Enhancing Unknown Waveform Detection by Learning Intra and Inter-domain Dependencies with Advanced Attention Fusion Mechanisms

Detection of unknown waveforms in mission-critical communications is a crucial area of interest for the Department of Energy (DoE). Traditional methods and recent deep learning-based approaches often assume that the training set includes all possible classes, which is impractical for detecting new waveforms. This limitation gives rise to the problem of open-set recognition (OSR), which involves correctly identifying known classes while detecting and rejecting unknown or unseen classes. To address this limitation, we propose a novel dual-domain complex-valued neural architecture that jointly processes time-domain and frequency-domain signal representations using transformer mechanisms. A transformer model is a deep learning architecture that uses self-attention mechanisms to process and learn relationships in sequential data. Our model employs a cosine similarity loss to extract domain-specific features and incorporates a transformer architecture in the latent space to weigh the importance of different features from the time and frequency domains. The transformer layer includes stacked self-attention and cross-attention modules to learn intra-domain and inter-domain dependencies, creating a more holistic signal representation. An attention-based fusion module intelligently combines the time and frequency-domain features using multi-head attention, enabling the network to learn the optimal feature for each domain in each input signal. Quantitative results demonstrate the impact of these architectural choices on overall performance, showing significant improvement after incorporating self and cross-attention modules and using complex attention fusion over simple weighted fusion. Our ongoing work will focus on addressing the limitations of threshold-based OSR methods by developing a novel generative framework that integrates a conditional diffusion probabilistic model (DPM). DPM is a generative framework that learns to synthesize complex data by reversing a gradual noising process using a neural network trained to denoise step-by-step. Our goal is to leverage the inherent strengths of DPMs for identifying unknown signals more robustly. One primary advantage of using a DPM is its ability to provide a more reliable anomaly score based on the model's reconstruction error, rather than relying solely on classifier confidence. Additionally, the iterative denoising process of DPMs makes this approach naturally resilient to low Signal-to-Noise Ratio (SNR) conditions, where traditional methods often fail. By implementing this generative framework, we aim to enhance the model's capability to accurately detect unknown waveforms and maintain performance in challenging environments.

99 - GENERAL AND MISCELLANEOUS↗

CMB Lensing Reconstruction Using Two Years of Temperature Data from the SPT-3G Summer Survey

We present the first reconstruction of the cosmic microwave background (CMB) lensing potential from the SPT-3G Summer survey using two years of temperature data. The Summer survey has a total area of approximately 2640 deg$^2$, split into three fields covering 1210, 570, and 860 deg$^2$, respectively. A joint analysis of the three Summer fields yields a lensing amplitude of $A^{\rm comb} = 1.015 \pm 0.053$ relative to a fiducial Planck 2018 $Λ$CDM cosmology for the multipole range $50 < L < 2000$. These early results from the SPT-3G Summer survey highlight the potential for increasing the signal-to-noise ratio when combining the Summer fields with the SPT-3G Main and Wide fields for a total SPT-3G survey area of $\sim$ 10,000 deg$^2$.

Levy, K. [Melbourne U.]↗

Data for Selected Ion Monitoring for Orbitrap-Based Metabolomics

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage.f

Mass Spectrometry↗

Utilization of the LS-APGD microplasma/orbitrap-FTMS booster system for detection and isotopic analysis of neodymium nanoparticles

Detection and isotopic analysis of particle populations has seen rapid growth across several application areas, including environmental analysis, nuclear forensics, and food safety. The ability to characterize the particles' unique elemental and isotopic fingerprints could provide information related to formation, processing history, and transport. Regarding nuclear forensics, isotopic analysis of particles derived from diverse materials is often used as a tool to trace the origin and processing history. Mass spectrometric-based techniques currently used for particle population analysis often suffer from limited mass resolution, particularly when dealing with real-world samples that are affected by isobaric and polyatomic interferences from the matrix. To address these analytical challenges, we propose a novel method utilizing the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an ultrahigh resolution Orbitrap mass spectrometer, further enhanced with the FTMS X2T Booster data acquisition and processing unit. The FTMS Booster enables acquisition of extended transient times of up to 3 s, significantly improving mass resolution, thereby reducing or even eliminating the need for prior separation of isobaric or polyatomic interferences. Additionally, the detection of low-abundance isotopes was improved by increasing the signal-to-noise (S/N) ratio. As proof of concept, this study demonstrates the feasibility of the LS-APGD/Orbitrap-FTMS X2T Booster platform for direct analysis using a suspension of well-characterized ∼120 nm neodymium particles. The quality of the isotope ratios values obtained from a few hundred particles were in good agreement with those obtained from homogeneous ionic solutions. These results highlight the potential of the LS-APGD/Orbitrap platform for rapid, accurate, and interference-resilient isotope ratio analysis of particle populations without the need for dissolution and subsequent chemical separations, offering significant advantages for nuclear forensics, safeguards, and environmental applications. The effort here also points to further paths forward, hopefully towards single particle (SP) analysis using microplasma ionization and the ultrahigh resolving power of the Orbitrap mass analyzer.

FTMS X2T booster↗

Evaluation of a generalized least squares algorithm for infrasound beamforming with coherent background noise

Infrasonic signals of interest can occur during periods with persistent, coherent, background noise, which may be natural or anthropogenic. For high signal-to-noise (SNR) ratio transient signals, an ‘overprinting’ of the coherent background may occur, and the signal may still be detected. However, this approach fails for low SNR signals of interest, which may be obscured by coherent noise. An infrasound beamforming method based on generalized least squares (GLS) is investigated for detecting transient signals of interest in the presence of coherent and incoherent background noise. This approach relies on an estimate of the noise covariance, captured in a covariance matrix, to effectively null contributions to the array response from noisy directions of arrival. Synthetic array data is used to investigate the performance of the GLS beamformer compared to the Bartlett beamformer when coherent and incoherent backgrounds are present. Additionally, the effects of array element number and relative strength of the interfering signal on the GLS estimates is investigated. GLS empirical area under the curve estimates suggest that the beamformer can recover coherent power for a signal of interest lower in amplitude than the coherent background, but this effectiveness degrades more quickly with SNR for a four element array compared to a six or eight element infrasound array. Finally, infrasound from the Forensic Surface Experiment, a bolide signal observed at IMS array I37NO, and a volcanic signal recorded at the Alaska Volcano Observatory array ADKI are used to evaluate GLS performance on recorded data. A ten minute window was used to capture the background noise, and the coherent background signal was nulled in all three examples.

58 GEOSCIENCES↗

Forecasting the Ly-𝛼 forest × CMB lensing bispectrum from ACT, SO, S4, and DESI

We forecast the sensitivity of future correlations between cosmic microwave background (CMB) lensing and the Lyman-𝛼 forest power spectrum. This squeezed-limit bispectrum probes the connection between the Lyman-𝛼 transmission and the underlying large-scale matter density field. We recover the measured signal-to-noise (SNR) ratio obtained with Planck × BOSS, and forecast a SNR of 10.3, 14.8 and 20.2 for DESI combined with ACT, SO, and CMB-S4, respectively. For DESI and SO/CMB-S4, the correlation should be detectable at SNR ≥ 5 in 5 redshift bins, useful for distinguishing our signal from several contaminants. Indeed, our forecast is affected by large theoretical uncertainties in the current modeling of the signal and its contaminants, such as continuum misestimation bias or damped-Lyman-𝛼 absorbers. Quantifying these more accurately will be crucial to enable a reliable cosmological interpretation of this observable in future measurements. We attempt to enumerate the features required in future Lyman-𝛼 forest simulations required to do so.

Cosmic microwave background↗

In-situ relative calibration of Bragg crystals with Monte Carlo line ratio analysis

X-ray line emission spectra can thoroughly characterize hot plasmas, especially when line shapes and ratios convey distinct aspects of plasma conditions. However, the high spectral resolution required for observing line shapes is often at odds with the large bandwidth required to observe many line ratios across a wide spectral range. One strategy to obtain high spectral resolution over a wide bandwidth is to use multiple crystals with calibrated reflectivity so that line intensities across different crystals can be compared. Here, we explore the use of a low-resolution, wide-bandwidth mica survey spectrometer to infer relative reflectivity of two high-resolution, narrow-bandwidth quartz crystals. Finally, a Monte Carlo error analysis determines comparable x-ray line ratios measured from both spectrometers, resulting in an in situ calibration factor and associated uncertainty for the relative reflectivity of the high-resolution crystals.

47 OTHER INSTRUMENTATION↗

Measurement of Thomson-scattering spectra with continuous angular resolution (invited)

Here, a novel Thomson-scattering diagnostic with continuous angular resolution over a span of 120° was developed for the characterization of plasmas produced at the Omega Laser Facility. Spectrally resolving light scattered from electron plasma wave features as a function of emission angle provides a means to efficiently probe a large range of plasma frequencies and k vectors. Together, these spectra contain critical constraints on the plasma-physics models used to interpret the data and enable experimental measurements of the electron-velocity distribution function over several orders of magnitude without assumptions about its mathematical form. Major components of the instrument include (1) a reflective collection objective that gathers light over a range of 120° × 12°; (2) a spatial-filter image relay for measurement localization; (3) cylindrical optics for producing a line image of the collection aperture; (4) a transmission grating spectrometer; and (5) a time-gated, image-intensified camera. Thomson-scattered light collected from an ~(50 – μM) 3 volume of plasma is recorded with 0.8-nm spectral and 1° angular resolution. Initial experiments examined the properties of the electron-velocity distribution in gas-jet-produced plasmas in the presence of heating via inverse bremsstrahlung absorption.

47 OTHER INSTRUMENTATION↗

Deep learning-driven super-resolution in Raman hyperspectral imaging: Efficient high-resolution reconstruction from low-resolution data

Deep learning (DL) has become an indispensable tool in hyperspectral data analysis, automatically extracting valuable features from complex, high-dimensional datasets. Super-resolution reconstruction, an essential aspect of hyperspectral data, involves enhancing spatial resolution, particularly relevant to low-resolution hyperspectral data. Yet, the pursuit of super-resolution in hyperspectral analysis is fraught with challenges, including acquiring ground truth high-resolution data for training, generalization, and scalability. The pressing issue of extended spectral acquisition times, notably for high-resolution scans, is a significant roadblock in hyperspectral imaging. Super-resolution methods offer a promising solution by providing higher spatial resolution data to expedite data collection and yield more efficient outcomes. This paper delves into a practical application of these concepts using Raman imaging, where spectral acquisition times can be prohibitively long. In this context, DL-based super-resolution models demonstrate their efficacy by predicting and reconstructing high-resolution Raman data from low-resolution input, eliminating the need for resource-intensive high-resolution scans. While previous work often relied on substantial high-resolution datasets, this study showcases the ability to achieve similar outcomes even with limited data, presenting a more practical and cost-effective approach. In conclusion, the results offer a glimpse into the transformative potential of this technology to streamline hyperspectral imaging applications by saving valuable time and resources through the successful generation of high-resolution data from low-resolution inputs.

42 ENGINEERING↗

A platform to measure isentropes from proton-heated warm dense matter on short pulse laser facilities

We describe the development of an experimental platform that measures the release isentrope of materials heated isochorically to temperatures of a few electron volts, using short-pulse laser-produced protons to heat the sample and long-pulse laser-produced x rays to perform streaked x-ray radiography. The density profiles derived from the radiography data are integrated to generate pressure–density isentropes, independent of prior knowledge of the equation of state of the sample material. In order to understand the sensitivities of isentrope extraction from radiography data, we analyze synthetic radiographs generated by a radiation hydrodynamics code. Noise reduction and high spatial resolution are critical for isentrope reconstruction, as demonstrated by the analysis of a proof-of-principle shot day on the OMEGA-EP facility. In conclusion, the data demonstrate the feasibility of the platform for characterizing isentropes, and we discuss the necessary improvements to enhance precision in differentiating between equation-of-state models.

Equations of state↗

Noise limits for dc SQUID readout of high- Q resonators below 300 MHz

We present the limits on noise for the readout of cryogenic high-Q resonators using dc Superconducting Quantum Interference Devices (SQUIDs) below 300 MHz. This analysis uses realized first-stage SQUIDs (previously published), whose performance is well described by Tesche–Clarke (TC) theory, coupled directly to the resonators. We also present data from a prototype second-stage dc SQUID array designed to couple to this first-stage SQUID as a follow-on amplifier with high system bandwidth. This analysis is the first full consideration of dc SQUID noise performance referred to a high-Q resonator over this frequency range and is presented relative to the standard quantum limit. We include imprecision, backaction, and backaction–imprecision noise correlations from TC theory, the noise contributed by the second-stage SQUIDs, wiring, and preamplifiers, and optimizations for both on-resonance measurements and off-resonance scan sensitivity. This architecture has modern relevance due to the increased interest in axion searches and the requirements of the DMRadio-m 3 axion search, which uses dc SQUIDs in this frequency range.

Bosons↗

Low spontaneous Brillouin scattering in anti-resonant hollow-core fibers in GHz frequency range

Brillouin light scattering (BLS) is a powerful experimental tool that can be used to gain insights into the fundamental and applied properties of matter, like dispersions of quasiparticles in a solid, as well as their spatiotemporal dynamics. Many applications of light scattering favor the use of optical fibers in place of free-space optics. In this study, we compare the performance of anti-resonant hollow core fibers to that of conventional solid core fused silica fibers for BLS experiments in the GHz frequency range. Conventional fibers are barely suitable for low-noise measurements because of the spontaneous scattering of photons on various phononic modes present in the core and cladding. In the case of the hollow-core fiber, we identify a range of discrete phononic modes and associate them with the various acoustic modes of the structure surrounding the hollow core using finite-element numerical simulations. The measured relative intensity of the spontaneous BLS signal from these modes is orders of magnitude smaller than that of a solid-core fiber, making anti-resonant hollow-core fibers one of the best solutions for the single-mode light guidance for BLS and potentially other low-noise photonic experiments.

36 MATERIALS SCIENCE↗

Denoising Seismograms in the Time Domain Using a Deep Learning Model

Deep learning has emerged as a transformative tool for enhancing the extraction of reliable information from seismograms, addressing the increasing demand for precise and efficient seismic data analysis. We introduce an innovative encoder–decoder deep learning model, named WaveDenoiser, designed for noise reduction in the time domain, thereby eliminating the need for spectrogram computations that have been used for existing deep learning tools and significantly improving processing speed. Utilizing the benchmark dataset that is Stanford Earthquake Dataset, we developed three models of varying sizes: base, medium, and large. Notably, the large (referred to as WaveDenoiser) model demonstrated superior performance, achieving a median signal‐to‐noise ratio improvement of 8.8 dB on in‐distribution unseen data (in the same geographic region) and 7.7 dB on out‐distribution unseen data (in a new geographic region), outpacing both the base and medium models. Further evaluation of the WaveDenoiser model revealed a reduction in median arrival‐time errors by 0.02 s for P waves and 0.01 s for S waves when processing waveforms prior to phase picking using PhaseNet on in‐distribution unseen data. When tested on out‐distribution unseen data, the model also effectively reduced the P‐wave median arrival‐time error by 0.02 and 0.01 s in median arrival‐time error for S waves. Importantly, the application of WaveDenoiser resulted in a significant reduction of phase picking outliers by 1.1% to 3.6% for both P and S waves. In addition, we achieved over five times acceleration in processing speed compared with the seisBench implementation of DeepDenoiser. Our findings underscore the potential of WaveDenoiser as a powerful tool for improving seismic data analysis and processing efficiency.

P-waves↗