Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Star Confusion Effect on SIM PlanetQuest Astrometric Performance

SIM PlanetQuest will measure star positions to an accuracy of a few microarcseconds using precise white light fringe measurements. One challenge for SIM observation scenario is "star confusion," where multiple stars are present in the instrument field of view. This is especially relevant for observing dim science targets because the density of number of stars increases rapidly with star magnitude. We study the effect of star confusion on the SIM astrometric performance due to systematic fringe errors caused by the extra photons from the confusion star(s}. Since star confusion from multiple stars may be analyzed as a linear superposition of the effect from single star confusion, we quantify the astrometric errors due to single star confusion surveying over many spectral types, including AOV, FOV, K5III, and MOV, and for various visual magnitude differences. To the leading order, the star confusion effect is characterized by the magnitude difference, spectral difference, and the angular separation between the target and confusion stars.Strategies for dealing with star confusion are presented. For example, since the presence of additional sources in the field of view leads to inconsistent delay estimates from different channels, with sufficient signal to noise ratio, the star confusion can be detected using chi-square statistics of fringe measurements from multiple spectral channels. An interesting result is that the star confusion can be detected even though the interferometer cannot resolve the separation between the target and confusion stars when their spectra are sufficiently different. Other strategies for mitigating the star confusion effect are also discussed.

crowded field↗

Testing of a Methane Cryogenic Heat Pipe with a Liquid Trap Turn-Off Feature for use on Space Interferometer Mission (SIM)

Camera cooling for SIM presents three thermal control challenges; stable operation at 163K (110 C), decontamination heating to +20 C, and a long span from the cameras to the radiator. A novel cryogenic cooling system based on a methane heat pipe meets these challenges. The SIM thermal team, with the help of heat pipe vendor ATK, designed and tested a complete, low temperature, cooling system. The system accommodates the two SIM cameras with a double-ended conduction bar, a single methane heat pipe, independent turn-off devices, and a flight-like radiator. The turn ]off devices consist of a liquid trap, for removing the methane from the pipe, and an electrical heater to raise the methane temperature above the critical point thus preventing two-phase operation. This is the first time a cryogenic heat pipe has been tested at JPL and is also the first heat pipe to incorporate the turn-off features. Operation at 163K with a methane heat pipe is an important new thermal control capability for the lab. In addition, the two turn-off technologies enhance the "bag of tricks" available to the JPL thermal community. The successful test program brings this heat pipe to a high level of technology readiness.

cyrogenic heat pipe↗

SIM-Lite Mission Spectral Calibration Sensitivities and Refinements

SIM-Lite missions will perform astrometry at microarcsecond accuracy using star light interferometry. For typical baselines that are shorter than 10 meters, this requires to measure optical path difference (OPD) accurate to tens of picometers calling for highly accurate calibration. A major challenge is to calibrate the star spectral dependency in fringe measurements -- the spectral calibration. Previously, we have developed a spectral calibration and estimation scheme achieving picometer level accuracy. In this paper, we present the improvements regarding the application of this scheme from sensitivity studies. Data from the SIM Spectral Calibration Development Unit (SCDU) test facility shows that the fringe OPD is very sensitive to pointings of both beams from the two arms of the interferometer. This sensitivity coupled with a systematic pointing error provides a mechanism to explain the bias changes in 2007. Improving system alignment can effectively reduce this sensitivity and thus errors due to pointing errors. Modeling this sensitivity can lead to further improvement in data processing. We then investigate the sensitivity to a model parameter, the bandwidth used in the fringe model, which presents an interesting trade between systematic and random errors. Finally we show the mitigation of calibration errors due to system drifts by interpolating instrument calibrations. These improvements enable us to use SCDU data to demonstrate that SIM-Lite missions can meet the 1pm noise floor requirement for detecting earth-like exoplanets.

wave front aberration↗

SIM testbed 3 real-time control software

SIM System Testbed 3 (STB3) features three optical interferometers sharing a common baseline, as a dynamic representation of the SIM instrument. An artificial star feeding the interferometers is installed on a separate optics bench. All three interferometers use photons captured by avalanche photo diodes (APDs) to measure the position and quality of fringes, and additional pointing precision is achieved by fast steering mirrors (FSMs) that keep the star images centered on the beam combining optics using a CCD camera. Each interferometer uses internal metrology to measure changes in its optical pathlength. External metrology beams measure changes in the baseline vector. This system acquires and tracks white light fringes with one interferometer, while the other two acquire and track laser light fringes representing the bright guide stars that will be used by SIM. The white light source represents a dim star that cannot supply enough photons for the Science interferometer to lock onto fringes in closed-loop mode; instead it operates open-loop, using pathlength corrections fed to it from the two guide interferometers and the external metrology subsystem to reject disturbances and maintain the fringes. This tracking mode is known as Pathlength Feed Forward (PFF). The precise real-time behavior required to achieve this result is implemented by a complex set of interacting software control loops. This paper describes how these loops take advantage of the benefits of the RTC Core architecture, and how they work together to accomplish STB3's objectives.

interferometry↗

Model validation of SIM external metrology at the sub-nanometer level

In order to achieve micro-arcsecond astrometry, SIM must make measurements of various optical path lengths at the picometer level. In this regime of precision, nearly every simplifying assumption in optics must be reexamined as a potential source of systematic error. SIM makes extensive use of physics-based models to predict the form and level of systematic errors affecting instrument performance. Since many of the modeling areas represent new frontiers in optical modeling, the validation of these physical models is a significant challenge that SIM must meet. In the case of the external metrology truss, the model must account for the imperfections in the corner cubes as well as the distance measuring interferometers ("beam launchers"). This model is being validated using the Kite testbed, a 2-D metrology truss with picometer-level accuracy in displacement measurements. We present the model and the results of the model validation tests on the Kite testbed.

Kuan, Gary M.↗

Probing the Orientation of Surface-Immobilized Protein G B1 Using ToF-SIMS Sum Frequency Generation and NEXAFS Spectroscopy

The ability to orient active proteins on surfaces is a critical aspect of many medical technologies. An important related challenge is characterizing protein orientation in these surface films. This study uses a combination of time-of-flight secondary ion mass spectrometry (ToF-SIMS), sum frequency generation (SFG) vibrational spectroscopy, and near-edge X-ray absorption fine structure (NEXAFS) spectroscopy to characterize the orientation of surface-immobilized Protein G B1, a rigid 6 kDa domain that binds the Fc fragment of IgG. Two Protein G B1 variants with a single cysteine introduced at either end were immobilized via the cysteine thiol onto maleimide-oligo(ethylene glycol)-functionalized gold and bare gold substrates. X-ray photoelectron spectroscopy was used to measure the amount of immobilized protein, and ToF-SIMS was used to measure the amino acid composition of the exposed surface of the protein films and to confirm covalent attachment of protein thiol to the substrate maleimide groups. SFG and NEXAFS were used to characterize the ordering and orientation of peptide or side chain bonds. On both substrates and for both cysteine positions, ToF-SIMS data showed enrichment of mass peaks from amino acids located at the end of the protein opposite to the cysteine surface position as compared with nonspecifically immobilized protein, indicating end-on protein orientations. Orientation on the maleimide substrate was enhanced by increasing pH (7.0-9.5) and salt concentration (0-1.5 M NaCl). SFG spectral peaks characteristic of ordered {alpha}-helix and {beta}-sheet elements were observed for both variants but not for cysteine-free wild type protein on the maleimide surface. The phase of the {alpha}-helix and {beta}-sheet peaks indicated a predominantly upright orientation for both variants, consistent with an end-on protein binding configuration. Polarization dependence of the NEXAFS signal from the N 1s to {pi}* transition of {beta}-sheet peptide bonds also indicated protein ordering, with an estimated tilt angle of inner {beta}-strands of 40-50{sup o} for both variants (one variant more tilted than the other), consistent with SFG results. The combined results demonstrate the power of using complementary techniques to probe protein orientation on surfaces.

59 BASIC BIOLOGICAL SCIENCES↗

Development of SIMS Standards for Measurement of H, C, O, N in Nb

Performance of SRF cavities is strongly dependent on the interior surface due to its shallow RF penetration depth. Therefore it is important to study Nb surface characteristics and identify elemental contamination which could affect the performance of the SRF Nb cavity. C, N, and O are of particular interest as interstitial contaminants and earlier work suggested very high H concentration [1]. Secondary Ion Mass Spectrometry (SIMS) has the depth resolution and sensitivity to quantitatively measure these species in the region of interest. However, standards for quantitative SIMS analysis of these elements in Nb did not exist. Initial attempts to develop an ion implanted standard were unsuccessful because of the roughness of the Nb surface and the inability to polish the soft metal Nb surface with traditional methods. In this study, Nb samples were specially chemical mechanical polished and then subsequently treated with a light buffered chemical polish (BCP). The result is a surface finish suitable for SIMS analysis and implantation standards. Ion implants of C, N, O, and deuterium (D) were obtained in Nb (and simultaneously in Si for dose verification). D was implanted to characterize H, and to avoid the high H background. The results show that D is apparently very mobile in Nb, and another approach will be required to quantify this element. This multi-element standard has already been of great benefit in characterization of C, O, and N in polycrystalline and large grain Nb [2]. [1] A. D. Batchelor, D. N. Leonard, P. E. Russell, F. A. Stevie, D. P. Griffis, G. R. Myneni, Proceedings of Single Crystal Niobium Technology Workshop, Brazil, AIP Conference Proceedings, Melville, NY (2007) 72-83. [2] P. Maheshwari, H. Tian, C. E. Reece, M. J. Kelley, D. P. Griffis, G. R. Myneni, F. A. Stevie, J. M. Rigsbee, A. D. Bachelor, Surface and Interface Analysis (in press) This work was authored by Jefferson Science Associates, LLC under U.S. DOE Contract No. DE-AC05-06OR23177

43 PARTICLE ACCELERATORS↗

Chemometric and Statistical Analyses of ToF-SIMS Spectra of Increasingly Complex Biological Samples

Characterizing and classifying molecular variation within biological samples is critical for determining fundamental mechanisms of biological processes that will lead to new insights including improved disease understanding. Towards these ends, time-of-flight secondary ion mass spectrometry (ToF-SIMS) was used to examine increasingly complex samples of biological relevance, including monosaccharide isomers, pure proteins, complex protein mixtures, and mouse embryo tissues. The complex mass spectral data sets produced were analyzed using five common statistical and chemometric multivariate analysis techniques: principal component analysis (PCA), linear discriminant analysis (LDA), partial least squares discriminant analysis (PLSDA), soft independent modeling of class analogy (SIMCA), and decision tree analysis by recursive partitioning. PCA was found to be a valuable first step in multivariate analysis, providing insight both into the relative groupings of samples and into the molecular basis for those groupings. For the monosaccharides, pure proteins and protein mixture samples, all of LDA, PLSDA, and SIMCA were found to produce excellent classification given a sufficient number of compound variables calculated. For the mouse embryo tissues, however, SIMCA did not produce as accurate a classification. The decision tree analysis was found to be the least successful for all the data sets, providing neither as accurate a classification nor chemical insight for any of the tested samples. Based on these results we conclude that as the complexity of the sample increases, so must the sophistication of the multivariate technique used to classify the samples. PCA is a preferred first step for understanding ToF-SIMS data that can be followed by either LDA or PLSDA for effective classification analysis. This study demonstrates the strength of ToF-SIMS combined with multivariate statistical and chemometric techniques to classify increasingly complex biological samples. Applying these techniques to information-rich mass spectral data sets opens the possibilities for new applications including classification of subtly different biological samples that may provide insights into cellular processes, disease progress, and disease diagnosis.

59 BASIC BIOLOGICAL SCIENCES↗

Combining ToF‐SIMS and Multivariate Analysis to Resolve Active Sites on Ni‐Based HER Catalysts

Unambiguous identification of active sites in heterogeneous catalysis remains a major challenge, particularly for materials with ultrathin, chemically mixed surface layers. Here, we demonstrate a generalizable approach that combines time-of-flight secondary ion mass spectrometry (ToF-SIMS) with multivariate statistical analysis (principal component analysis [PCA] and multivariate curve resolution [MCR]) to resolve catalytically relevant motifs at the nanoscale. Using Ni electrodes as a model system, PCA distinguished hydroxide-enriched domains from oxide- and metal-rich regions, while MCR decomposed depth profiles and 3D images into hydroxide, oxide, and metallic layers with nanometer resolution. A unique secondary-ion fragment, NiO 3 H 3 − (m/z 108.94), emerged as a marker of hydroxide-rich environments and correlated with hydrogen evolution reaction (HER) activity across a series of Ni electrodes. Complementary density functional theory (DFT) calculations revealed that Ni(OH) 2 clusters adjacent to metallic Ni offer the most favorable water dissociation energetics, establishing the structural origin of the marker. While illustrated here for Ni-based HER, this workflow provides a broadly applicable framework to isolate and rank near-surface patterns that govern catalytic activity, thereby extending ToF-SIMS from a qualitative probe to a predictive tool for active site identification.

HER active sites↗

An Investigation of Hydrogen Depth Profiling Using ToF-SIMS

Hydrogen depth distributions in silicon, zinc oxide and glass are of great interest in material research and industry. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) has been used for hydrogen depth profiling for many years. However, some critical information, such as optimal instrumental settings and detection limits, is not easily available from previous publications. In this work, optimal instrumental settings and detection limits of hydrogen in silicon, zinc oxide and common glass were investigated. The recommended experimental settings for hydrogen depth profiling using ToF-SIMS are: (1) keeping pressure in the analysis chamber as low as possible, (2) using a cesium beam for sputtering and monitoring the H{sup -} signal, (3) employing monatomic ion analysis beams with the highest currents, and (4) using interlace mode. In addition, monatomic secondary ions from a matrix are recommended as references to normalize the H{sup -} signal. Detection limits of hydrogen are limited by pressure of residual gases in the analysis chamber. The base pressure of the analysis chamber (with samples) is about 7 x 10{sup -10} mbar in this study, and the corresponding detection limits of hydrogen in silicon, zinc oxide, and common glass are 1.3 x 10{sup 18} atoms/cm{sup 3}, 1.8 x 10{sup 18} atoms/cm{sup 3}, and 5.6 x 10{sup 18} atoms/cm{sup 3}, respectively.

08 HYDROGEN↗

In situ SEM and ToF-SIMS analysis of IgG conjugated gold nanoparticles at aqueous surfaces

In this study, we report new results of in situ study of 5 nm goat anti-mouse IgG gold nanoparticles in a novel portable vacuum compatible microfluidic device using scanning electron microscope (SEM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The unique feature of the liquid flow cell is that the detection window is open to the vacuum allowing direct probing of the liquid surface. The flow cell is composed of a silicon nitride (SiN) membrane and polydimethylsiloxane (PDMS), and it is fully compatible with vacuum operations for surface analysis. The aperture can be drilled through the 100 nm SiN membrane using a focused ion beam. Characteristic signals of the conjugated gold nanoparticles were successfully observed through the aperture by both energy-dispersive X-ray spectroscopy (EDX) in SEM and ToF-SIMS. Comparison was also made among wet samples, dry samples, and liquid sample in the flow cell using SEM/EDX. Stronger gold signal can be observed in our novel portable device by SEM/EDX compared with the wet or dry samples, respectively. Our results indicate that analyses of the nanoparticle components are better made in their native liquid environment. This is made possible using our unique microfluidic flow cell.

aqueous surface↗

ToF-SIMS in material research: A view from nanoscale hydrogen detection

Hydrogen in materials has attracted tremendous interest as its incorporation leads to significant alterations in nanoscale structure, composition, and chemistry, impacting functional properties. It has also been integral to nuclear fusion reactors and is considered a future clean energy source. However, nanoscale characterization and manipulation of hydrogen in materials are challenging as only a selected few analytical techniques can readily detect hydrogen, among which time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a unique and powerful one due to its excellent detection limit along with decent depth and lateral resolutions. Here, in this review, we discuss, using selected examples, how to detect and quantify hydrogen in materials by ToF-SIMS and its impact on revealing the hydrogenation/protonation-induced novel functional states in different classes of materials. In addition, we present our protocols on sample preparation and experimental conditions optimization, allowing us to achieve the best possible results. Finally, we highlight future research directions that can lead to the discovery of novel functional states and ultimately provide a deeper understanding of scientific questions in materials science.

36 MATERIALS SCIENCE↗

Study of cluster ions produced from ToF-SIMS analysis of a U-6%Nb target

Cluster ions have been previously observed during time-of-flight secondary ion mass spectrometry (ToF-SIMS) analysis of metals and metal oxides. Furthermore, we have used ToF-SIMS to investigate cluster ions formed from the hydrocarbon-containing overlayer, the mixed U and Nb surface oxide, and underlying metal of a U-6 %Nb (U6Nb) target. In the overlayer, we observe U x O y + oxides and U-species likely containing hydrocarbons. In the surface oxide, we observe UO 2 +, U 2 O 2 +, U 3 O 5 +, and U 4 O 6 + as the most intense ions for each family of oxide ions containing x U atoms. Nb oxides for NbO 1-2 - were only observed in negative polarity. In contrast to the oxide, analysis of the underlying U6Nb alloy resulted in repeating units of U n +, U n (Nb)+, and U n (Nb 2 ) + ions for n = 3–11 as the highest intensity ions for each family of ions containing n U atoms. Nb n + clusters were not observed. U n +, U n (Nb)+, and U n (Nb 2 )+ clusters containing C- and O-species were observed and were likely produced from soluble C or O species or precipitates known to be present in U6Nb.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular Determination of Organic Adsorption Sites on Smectite during Fe Redox Processes Using ToF-SIMS Analysis

Turnover of soil organic carbon (SOC) is strongly affected by a balance between mineral protection and microbial degradation. However, the mechanisms controlling the heterogeneous and preferential adsorption of different types of SOC remain elusive, especially for humic substrates (HSs) and microbial carbon (MC), two hotly-debated forms of SOC prevalent in soils. In this work, the heterogeneous adsorption of HSs and MC on a clay mineral (nontronite NAu-2) during microbial-mediated Fe redox cycling was determined with the use of time-of-flight secondary ion mass spectrometry (ToF-SIMS). The results revealed that HSs pre-adsorbed on NAu-2 would partially inhibit the microbial Fe(III) reduction and structural modification of NAu-2, thus retarding the subsequent adsorption of MC. In contrast, NAu-2 without pre-coated HSs was adsorbed by a significant amount of MC from microbial polysaccharides as a result of Fe(III) reduction. This was attributed to the deposition of a thin Al-rich layer on clay surface, which provided active sites for MC adsorption. This study provides direct and detailed molecular evidence for the first time to explain the preferential adsorption of MC over HSs on the surface of clay minerals in the iron redox processes, which could be critical for the preservation of MC in soil. The results also indicate that ToF-SIMS is a unique tool for understanding complex organic-mineral-microbe interactions.

54 ENVIRONMENTAL SCIENCES↗

Liquid ToF-SIMS revealing the oil, water, and surfactant interface evolution

Bilge water from ships is regarded as a major pollutant in the marine environment. Bilge water exists in a stable oil-in-water (O/W) emulsion form. However, little is known about the O/W liquid–liquid (l–l) interface. Traditional bulk characterization approaches are not capable of capturing the chemical changes at the O/W l–l interface. Although surfactants are deemed essential in droplet formation, their roles in bilge water stabilization have not been fully revealed. We have utilized novel in situ chemical imaging tools including in situ scanning electron microscopy (SEM) and in situ time-of-flight secondary ion mass spectrometry (ToF-SIMS) to study the evolving O/W interface using a NAVY bilge model for the first time. The droplet size distribution (DSD) does not change significantly without the addition of X-100 surfactants under static or rocking conditions. Both the oil components and the water clusters are shown to evolve over time at the O/W droplet interface by in situ liquid SIMS imaging. Of particular interest to droplet stabilization, the contribution of surfactants to the aged bilge droplets becomes more significant as the droplet size increases. The higher mass surfactant component does not appear on the droplet surface immediately while many lower mass surfactants are solvated inside the droplet. We have provided the first three-dimensional images of the evolving O/W interface and demonstrated that in situ surface chemical mapping is powerful enough to reveal the complex and dynamic l–l interface in the liquid state. Our observational insights suggest that surfactants are important in mediating droplet growth and facilitating effective separation of bilge water emulsion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Novel Method to Investigate Stoichiometry and Performance of Buried Passivated Contacts Utilizing Time-of-Flight SIMS

We report on methods using time-of-flight secondary-ion mass spectrometry (TOF-SIMS) to elucidate critical information about the buried interfaces in interdigitated back-contact silicon solar cells. We examined the stoichiometry of the tunneling oxide with TOF-SIMS and X-ray photoelectron spectroscopy (XPS). Interestingly, the data indicates that the stoichiometry of the tunneling oxide moves away from SiO 2 towards lower stoichiometry (SiO x ) upon the crystallization annealing treatment, and towards SiO 2 again upon Al 2 O 3 deposition and a subsequent forming gas anneal. We also report on an important artifact for samples with an Al 2 O 3 passivation layer related to the oxygen content of the matrix.

14 SOLAR ENERGY↗

Understanding Chemical Inhomogeneities and Cation Gradients in Perovskite Photovoltaics with TOF-SIMS

Time-of-flight secondary-ion mass spectrometry (TOF-SIMS) is one of the few techniques that can obtain chemical information from all components of hybrid organic-inorganic perovskite photovoltaics in up to three dimensions. This can yield critical insight into the uniformity of the cations through the thickness of the film (with sub-nm resolution), as well as laterally (with 100nm resolution) We have been using a TOF-SIMS to analyze perovskite photovoltaics at NREL for more than four years and have found many tricks and best practices, summarized here, to get around known artifacts when depth profiling and imaging.

14 SOLAR ENERGY↗

Insights into Na + Diffusion in Silicon Modules under Operating Conditions: Measuring Low Concentrations by D-SIMS

Sodium induced shunting under an electric field is a challenging reliability issue in crystalline Si solar modules. The source of this Potential-Induced Degradation of the Shunting type (PID-s) is well understood and its influence on power loss has been intensively studied based on phenomenological models on cell or module level relating the experimental power-loss to stressing parameters (time, temperature, voltage). However, little is known about the Na ion migration kinetics, responsible for PID on a microscopic level, and its quantitative relation to the efficiency degradation. In this paper we present our investigations of sodium ion migration in Ethylene-Vinyl Acetate (EVA) and silicon through Dynamic Secondary Ion Mass Spectroscopy (D-SIMS). Each sample was annealed at field relevant temperatures from 60-90 °C to address typical migration mechanisms of common PV installations. Analysis of the SIMS migration profiles revealed a diffusivity constant D 0,EVA = 0.09 ± 0.14 cm 2 /s and an activation energy E A,EVA = 0.85 ± .04 eV for Na in EVA and diffusivities higher than extrapolated literature values in silicon (D 0,Si = (3.03 ± 2.42)x10 -5 cm 2 /s, and E A,Si = 0.98 ± 0.02 eV). The new insight will be included in a drift-diffusion based degradation model accounting for the partition coefficient across all relevant interfaces. This model can assist in predicting PID-failure in the field based on the given model stack and the diffusion of Na + through each material. Furthermore, this tool can be used for process optimization as well as material selection significantly reducing the cost and time to validate a technology.

14 SOLAR ENERGY↗