Search NASA⌕ Search

SEARCH · Search NASA

Results for “SINGLE PHOTON DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Patterned anodes with sub-millimeter spatial resolution for large-area MCP-based photodetector systems

Micro-channel-plate-based photo-detectors are unique in being capable of covering very large areas such as those required in elementary particle and nuclear physics, while providing sub-millimeter space resolution, time resolutions of less than 10 picoseconds for charged particles, and time resolutions of 30 psec–50 psec for single photons. In such systems the electronic channel count is a major cost driver. Incorporating a capacitively-coupled anode allows the use of external pickup electrodes with patterns of individual channels optimized for occupancy, rate, and time/space resolution. The signal pickup antenna can be economically implemented as a printed circuit card with a 2-dimensional array of pads for high-occupancy/high-rate applications such as in particle colliders and medical imaging, or a 1-dimensional array of strips for a lower channel count in low-occupancy/low-rate applications such as large neutrino detectors. In this paper we present pad patterns that enhance signal-sharing between pads to lower the channel count per unit area in large-area systems by factors up to 4, while maintaining spatial resolutions of approximately 100 to 200 μ m for charged particles and 400 to 1000 μ m for single photons. Patterns that use multiple signal layers in the signal-pickup board can lower the channel count even further, moving the scaling behavior in the number of pads versus total area from quadratic to linear.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of photosensors in a high-rate environment for gas Cherenkov detectors

We report the solenoidal large intensity device (SoLID) at Jefferson Lab will push the boundaries of luminosity for a large-acceptance detector, which necessitates the use of a light-gas threshold Cherenkov counter for online event selection. Due to the high luminosity, the single-photon background rate in this counter can exceed 160 kHz/cm 2 at the photosensors. Therefore, it is essential to validate the high-rate limits of the planned photosensors and readout electronics in order to mitigate the risk of failure. We report on the design and an early set of studies carried out using a small Cherenkov counter in a high-rate environment up to 60 kHz/cm 2 , in Hall C at Jefferson Lab. Commercially available multi-anode photomultipliers (MaPMT) and low-cost large-area picosecond photodetectors (LAPPD) were tested using the JLab FADC250 modules for readout. The test beam results show that the MaPMT array and the internal stripline LAPPD can detect and identify single-electron and pair-production events in high-rate environments. Due to its higher quantum efficiency, the MaPMT array provided a better separation between the single-electron and the pair-production events compared to the internal stripline LAPPD. A GEANT4 simulation confirms the beam test performance of our counter device.

47 OTHER INSTRUMENTATION↗

Characterization of the DUNE photodetectors and study of the event burst phenomenon

The Deep Underground Neutrino Experiment (DUNE) is an upcoming neutrino physics experiment that will answer some of the most compelling questions in particle physics and cosmology. The DUNE far detectors employ silicon photomultipliers (SiPMs) to detect light produced by charged particles interacting in a large liquid argon time projection chamber (LArTPC). The SiPMs are photosensors consisting of an array of single-photon avalanche diodes (SPAD) operating in Geiger mode. Their high sensitivity and dynamic range, as well as the possibility to fill large surfaces with high-granularity sensors, makes them an ideal choice for DUNE. An international consortium of research groups is currently engaged in a systematic comparison of the performances of the SiPM models that have been custom developed for DUNE by two manufacturers. Such detailed studies, which include gain measurements and a structure study of the dark count rate at 77 K, are meant to determine the best choice of the photodetection system for DUNE, as well as characterize the response of the chosen detectors for the DUNE simulation. Moreover, an investigation of a newly observed phenomenon, in which quick bursts of tens of events at close range are collected in individual SiPMs, is being carried out, which potentially impacts the design of future models and their implementation in particle physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancing strontium clock atom interferometry using quantum optimal control

Strontium clock atom interferometry is a promising new technology, with multiple experiments under development around the world to explore its potential for dark matter and gravitational wave detection. In these detectors, large momentum transfer using sequences of many laser pulses is necessary, and thus high-fidelity pulses are important since small errors become magnified. Quantum optimal control (QOC) is a framework for developing control pulse waveforms that achieve high fidelity and are robust against experimental imperfections. Resonant single-photon transitions using the narrow clock transition of strontium involve significantly different quantum dynamics than more established atom interferometry methods based on far-detuned two-photon Raman or Bragg transitions, which leads to new opportunities and challenges when applying QOC. Here, we study in simulation QOC pulses for strontium clock interferometry and demonstrate their advantage over basic square pulses (primitive pulses) and composite pulses in terms of robustness against multiple noise channels. In conclusion, this could improve the scale of large momentum transfer in Sr clock interferometers, paving the way to achieving these scientific goals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of the charge asymmetry in top-quark pair production in association with a photon with the ATLAS experiment

A measurement of the charge asymmetry in top-quark pair ($t\bar{t}$) production in association with a photon is presented. The measurement is performed in the single-lepton $t\bar{t}$ decay channel using proton–proton collision data collected with the ATLAS detector at the Large Hadron Collider at CERN at a centre-of-mass-energy of 13 TeV during the years 2015–2018, corresponding to an integrated luminosity of 139 fb –1 . The charge asymmetry is obtained from the distribution of the difference of the absolute rapidities of the top quark and antiquark using a profile likelihood unfolding approach. It is measured to be A C =–0.003 ± 0.029 in agreement with the Standard Model expectation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of a Small-Scale Prototype Detector With Wide Dynamic Range for Time-Resolved High-Energy X-Ray Applications

We present characterization measurements of a fast-framing, wide-dynamic-range x-ray area detector intended for high-energy applications (≥20 keV photons). The MM-PAD-2.1 combines an integrating pixel front-end with a charge-removal mechanism to extend the maximum measurable signal to > 107 20-keV ph/pixel/frame. The charge-removal mechanism is dead-time-less (i.e., incoming signal continues to be integrated by the front-end while charge removal is taking place) up to an incoming photon rate of > 109 20-keV ph/pix/s. A 16×16 pixel prototype was fabricated and characterized using both laboratory and synchrotron x-ray sources, allowing for measurements from single-photon to high-flux conditions. High-flux measurements show linear performance up to ~1010 ph/s in a spot spanning approximately 2×1.5 pixels (FWHM). The onset of temporary radiation damage in the detector was observed during these measurements, manifesting as failure of the digital readout from the detector. These effects were seen to reverse after annealing at 30° C for several hours.

47 OTHER INSTRUMENTATION↗

VeryFastCCD: a high frame rate soft X-ray detector

Direct X-ray detection in silicon has been transformative for scattering experiments in biology and materials science. While bump-bonded hybrid pixels have been attractive for hard X-ray detection, the challenge for single photon soft X-ray detection is sufficiently low noise. CCD structures on thick, high-resistivity silicon have been successfully used as sensors over the range of soft to hard X-rays at storage rings and FELs. The VeryFastCCD is a high frame rate, column-parallel CCD sensor with 48 μm pixels. Combined with 256-channel custom readout ASICs, frame rates of 5–10 kHz have been achieved with readout noise as low as 20 e and full-well capacity >4 × 10 5 e/pixel. Thin (10 nm and 100 nm) entrance window contact processes have also been developed which provide >85% quantum efficiency for 285 eV X-rays. Systems are currently being developed for several beamlines at the upgraded Advanced Light Source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SCGSR Final Report

Dual phase noble liquid time projection chambers (TPCs) have an unprecedented sensitivity towards dark matter searches and neutrinos, owing to their ability to detect single electrons. When a particle deposits energy into one of these detectors, electrons are released and drifted into a gaseous region of high electric field. In the gas, the electrons are accelerated to produce extra light into what is called an S2 pulse. This light is far easier to detect than the current induced from a single electron. The two widely used elements for noble liquid detectors are Xe and Ar. Xe has a larger chance of being hit by neutrinos or dark matter, but ends with a lower (i.e. harder to detect) energy when struck. However, Ar light is hard to reflect and detect due to its short wavelength which is absorbed by most materials. While one may use TPB to re-emit this light at a longer wavelength, spatial variations of TPB thickness can smear the amount of re-emitted light, and thus cause a poor S2 energy resolution and spatial resolution. Furthermore, a single electron pulse in Ar is spread over a much longer time than one in Xe, which makes it harder to identify single electrons in Ar. The goal of Xe doping is to combine the best aspects of Ar with the best aspects of Xe. More specifically, this means a detector with a larger yield of photons and electrons produced per energy deposition, an ability to collect more of the light given by those signals, and a narrower pulse from the electron signal. During this project, we developed and operated a detector that can overcome the thermodynamic challenges of Xe doping – namely, preventing Xe from freezing. In the first experimental run during this award period, we found that we can achieve at least 5% of Xe in LAr, and measure the Xe concentration in the gas. In the second run, we installed our detector and saw the first S2 pulses in a dual phase Xe doped LAr TPC. With the data we took, we quantified the effect of Xe doping on the detectability of wavelength-shifted light produced in a Xe doped Ar mixture, as well as the single electron pulse shape. While the Ar light has successfully been wavelength shifted, we learned that much to our surprise, Xe doping actually makes the S2 pulse wider before it makes it narrower.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance and Commissioning of the BigBite Timing Hodoscope for Nucleon Form Factor Measurements at Jefferson Lab

The BigBite Timing Hodoscope detector is the primary subject of this thesis. The Super BigBite Spectrometer is a Jefferson Lab Hall A Collaboration project that has and will continue to measure nucleon electromagnetic form factors. This spectrometer includes the Timing Hodoscope which provides high resolution particle timing data for scattered electrons in the electron arm of BigBite. The Timing Hodoscope utilizes 90, 25 × 25 × 600 mm3 scintillator bars stacked on top of each other to form a single detector plane, and these bars are connected to 180 photo-multiplier tubes via light guides. Particles collide with the scintillating material creating a shower of optical photons and these particle events in the bars are collected to generate signals that are readout by the data acquisition (DAQ) electronics. NINO ASIC amplifier-discriminator cards output signals from the photo-multiplier tubes into analogue and logic signals, which are sent to analogue-to-digital (ADC) and time-to-digital (TDC) converter data acquisition readout modules. This data is then used for analysis of the detector. The focus of this thesis is the construction, commissioning, calibration, and performance of the BigBite Timing Hodoscope before and during the first of five nucleon electromagnetic form factor experiments at Jefferson Lab Hall A. Before the neutron magnetic form factor, G n M, experiment, cosmic ray data was collected during commissioning to confirm proper operation of the Timing Hodoscope electronics by observing the ADC and TDC data. Commissioning studies for charge normalization, gain matching, and other ADC and TDC detector data variables were performed before moving the detector into Hall A. Following installation in Hall A, several calibration studies were implemented to fine-tune the detector in preparation for use in the experiment. The calibration studies included analysis of timing cuts, TDC alignment, the time-walk effect, time difference offsets, and scintillator velocity corrections. Once the Timing Hodoscope was well-calibrated, data-taking during the experiment commenced and the beam-on-target data was used to characterize the Timing Hodoscope performance during the G n M experiment run-time. The performance analysis included studies observing energy deposit, cluster size, rates, accidentals, pile-up, tracking efficiency, position resolution, and time resolution. After application of physics cuts to ensure a data set comprised of particle tracks corresponding to elastic electrons, which is the main data of interest for measurement of G n M, the Timing Hodoscope is shown on average across all kinematic settings to have a >98% tracking efficiency, a position resolution of 4-6 cm in the non-dispersive plane and 1.5-2 cm in the dispersive plane, and a time resolution of 500-750 ps. These performance results are compared to a GEANT4 based performance simulation of the BigBite Timing Hodoscope for reference, showing to what degree the measured performance values match those taken from the simulation.

Marinaro, Ralph↗

In situ cryogenic characterization of proton damage in thick p-channel skipper CCDs

Skipper charge-coupled devices (CCDs) are an offshoot of standard silicon pixel detectors and are capable of performing repeated non-destructive charge measurements, enabling deeply sub-electron readout noise. This capability has opened the door to single-photon counting from the near-infrared ($\sim$1.1 $μ$m) to the soft X-ray (several keV), making these devices strong candidates for future astronomical instruments operating in the photon-starved limit. Furthermore, the p-channel architecture used to fabricate Skipper CCDs on n-type silicon has been demonstrated to have an increased hardness to the intense radiation environment of space. Building upon previous irradiation campaigns on room-temperature sensors, here we describe the first radiation-hardness tests of p-channel skipper CCDs at their cryogenic operating temperatures. We assess the performance of the floating-gate output stage and global CCD parameters (charge transfer inefficiency, dark current, hot pixels, and charge traps). We find that these devices maintain excellent performance after displacement damage doses equivalent to ${\sim}$10 years at the Earth/Sun L2 Lagrange point, demonstrating for the first time that these sensors remain radiation-hard in realistic deep-space thermal and radiation environments.

Roach, Brandon M. [Chicago U., KICP] (ORCID:000000↗

Pulse-shape discrimination against low-energy Ar-39 beta decays in liquid argon with 4.5 tonne-years of DEAP-3600 data

The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from 39 Ar beta decays and is suppressed using pulse-shape discrimination (PSD). We use two types of PSD estimator: the prompt-fraction, which considers the fraction of the scintillation signal in a narrow and a wide time window around the event peak, and the log-likelihood-ratio, which compares the observed photon arrival times to a signal and a background model. We furthermore use two algorithms to determine the number of photons detected at a given time: (1) simply dividing the charge of each PMT pulse by the mean single-photoelectron charge, and (2) a likelihood analysis that considers the probability to detect a certain number of photons at a given time, based on a model for the scintillation pulse shape and for afterpulsing in the light detectors. The prompt-fraction performs approximately as well as the log-likelihood-ratio PSD algorithm if the photon detection times are not biased by detector effects. We explain this result using a model for the information carried by scintillation photons as a function of the time when they are detected.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hardware, methodology and applications of 2 + D backscatter Mössbauer spectroscopy with simultaneous x-ray and γ-ray detection

Abstract A unique method is presented for the acquisition and analysis of 57 Fe backscatter Mössbauer spectra with simultaneous detection of the resonant 14.4 keV γ -rays and the characteristic 6.4 keV x-rays, using a custom-built multi-parameter analyser constructed on the basis of commercial analogue to digital converters and high-speed digital latches. The system allows for the simultaneous registration of Doppler-modulation velocities and photon energies, with up to 4096 and 8192 digital channels respectively. This arrangement is in contrast to most related systems, which detect at a single narrow energy window per detector. Samples of arbitrary atomic structure, morphology and surface topography can be studied without altering the setup or the analysis procedure, provided that the samples are at least micrometre sized. The hardware and software that are used to acquire data with minimal dead time are described and the custom and self-contained methods for post-measurement energy discrimination, background correction and velocity-axis folding are discussed. The data are fit using a general Hamiltonian model for the nuclear energy levels of 57 Fe and a quantum mechanical description of the angular momentum coupling is utilised, with consideration of the crystalline and chemical disorder of the sample under examination. Three examples of distinct magnetic systems, with thicknesses ranging from 5 μ m to 6 mm, that were studied using this method are presented, these are: an amorphous CoFeB-based ribbon with ultra-soft coercivity for high-frequency applications, magnetically hard Nd-Fe-B thick films on Si substrates, examined in both as-deposited and annealed states, and a sample from the nickel-rich iron meteorite NWA 6259 that contains the atomically ordered, elevated coercivity, L 1 0 phase of FeNi, tetrataenite. The wide applicability and usefulness of this method is thus demonstrated on three distinct sample morphologies that required little to no surface preparation prior to examination.

Engineering↗

Front-End Design for SiPM-Based Monolithic Neutron Double Scatter Imagers

Neutron double scatter imaging exploits the kinematics of neutron elastic scattering to enable emission imaging of neutron sources. Due to the relatively low coincidence detection efficiency of fast neutrons in organic scintillator arrays, imaging efficiency for double scatter cameras can also be low. One method to realize significant gains in neutron coincidence detection efficiency is to develop neutron double scatter detectors which employ monolithic blocks of organic scintillator, instrumented with photosensor arrays on multiple faces to enable 3D position and multi-interaction time pickoff. Silicon photomultipliers (SiPMs) have several advantageous characteristics for this approach, including high photon detection efficiency (PDE), good single photon time resolution (SPTR), high gain that translates to single photon counting capabilities, and ability to be tiled into large arrays with high packing fraction and photosensitive area fill factor. However, they also have a tradeoff in high uncorrelated and correlated noise rates (dark counts from thermionic emissions and optical photon crosstalk generated during avalanche) which may complicate event positioning algorithms. We have evaluated the noise characteristics and SPTR of Hamamatsu S13360-6075 SiPMs with low noise, fast electronic readout for integration into a monolithic neutron scatter camera prototype. The sensors and electronic readout were implemented in a small-scale prototype detector in order to estimate expected noise performance for a monolithic neutron scatter camera and perform proof-of-concept measurements for scintillation photon counting and three-dimensional event positioning.

47 OTHER INSTRUMENTATION↗

Characterization of an architecture for front-end pixel binning in an integrating pixel array detector

Optimization of an area detector involves compromises between various parameters like frame rate, read noise, dynamic range and pixel size. We have implemented and tested a novel front-end binning design in a photon-integrating hybrid pixel array detector using the MM-PAD- 2.0 pixel architecture. In this architecture, the pixels can be optionally binned in a 2 x 2 pixel configuration using a network of switches to selectively direct the output of 4 sensor pixels to a single amplifier input. Doing this allows a trade-off between frame rate and spatial resolution. Tests show that the binned pixels perform well, but with some degradation on performance as compared to an un-binned pixel. The increased parasitic input capacitance does reduce the signal collected per x-ray as well as increases the noise of the pixel. Here, the increase in noise is, however, less than the factor of 2 increase one would observe for binning in post-processing. Spatial scans across the binned pixels show that no measured signal intensity is lost at the inner binning unit boundaries. In the high flux regime, at a 2 x 2 pixel wide beam spot (FWHM) size, binned mode responds linearly up to a photon flux of 10 7 x-rays/s, and performs comparably with un-binned mode up to a photon flux of 10 8 x-rays/s. While this study demonstrates a proof of concept for front-end binning in integrating detectors, we also identify changes to this early-stage prototype which can further improve the performance of binning pixel structures.

47 OTHER INSTRUMENTATION↗

DUAL-PARTICLE DOSEMETER BASED ON ORGANIC SCINTILLATOR

Abstract Traditionally available handheld dosemeters are generally sensitive to only one type of radiation: neutrons or photons. Some dosemeters also rely on very specific attenuation correlations between response and dose, are not scalable in size and multiple dosemeters are required to characterise mixed-particle fields. The research presented here serves as a proof-of-concept for a method to simultaneously measure dose rates from neutrons and photons using a particle discriminating organic scintillation detector without the need for spectral deconvolution. The method was compared with traditional instruments and to simulation. Isotopic photon dose rates measured with this method were within 4% of simulated truth, whereas fission spectrum neutron dose rates were measured within 21%. Measurements of dose rates from both particles agree with simulated truth better than traditional instruments. This new method allows for measurement of dose equivalent from both neutrons and photons with a single instrument and no reliance on spectral deconvolution.

Miller, C. A.↗

The DUNE Vertical Drift Photon Detection System

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino experiment designed to mainly investigate oscillation parameters, supernova physics and proton decay. Its far detector will be composed of four liquid argon time projection chamber (LArTPC) underground modules, in South Dakota-USA, which will detect a neutrino beam produced at Fermilab, 1300 km away, where a near detector will be in place. The second DUNE far detector module, Vertical Drift, will be a single phase LArTPC with electron drift along the vertical axis with two volumes of 13.5 m x 6.5 m x 60 m dimensions separated by a cathode plane. The charge collection will be performed by two anode planes placed at the top and bottom of the module, each composed by stacked layers of a perforated PCB technology with electrode strips. The photon detection system (PDS) will make use of large size X-Arapuca tiles distributed over three detection planes. One plane will consist of a horizontal arrangement of double sided tiles installed on the high voltage cathode plane and two vertical planes, each placed on the longest cryostat membrane walls. A light active coverage of 14.8% over the cathode and 7.4% over the laterals should allow improvements in the low energy physics range that can be probed in DUNE, especially regarding supernova neutrinos (~10 MeV). We present the initial characterization of the Vertical Drift PDS using a Monte Carlo simulation and preliminary studies on its reconstruction capabilities at the MeV scale. The information obtained with the PDS alone should allow determination of a neutrino interaction region with a precision of at least 65 cm for events with deposited energy above 5 MeV and the deposited energy can be reconstructed with precision better than 10%, both at the center of the volume.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First results on ProtoDUNE-SP liquid argon time projection chamber performance from a beam test at the CERN Neutrino Platform

The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber with an active volume of 7.2× 6.1× 7.0 m3. It is installed at the CERN Neutrino Platform in a specially-constructed beam that delivers charged pions, kaons, protons, muons and electrons with momenta in the range 0.3 GeV/c to 7 GeV/c. Beam line instrumentation provides accurate momentum measurements and particle identification. The ProtoDUNE-SP detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment, and it incorporates full-size components as designed for that module. This paper describes the beam line, the time projection chamber, the photon detectors, the cosmic-ray tagger, the signal processing and particle reconstruction. It presents the first results on ProtoDUNE-SP's performance, including noise and gain measurements, dE/dx calibration for muons, protons, pions and electrons, drift electron lifetime measurements, and photon detector noise, signal sensitivity and time resolution measurements. The measured values meet or exceed the specifications for the DUNE far detector, in several cases by large margins. ProtoDUNE-SP's successful operation starting in 2018 and its production of large samples of high-quality data demonstrate the effectiveness of the single-phase far detector design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A search for new physics in low-energy electron recoils from the first LZ exposure

Searches for new physics signatures in low-energy electron recoils using a fiducial LXe mass of 5.5±0.2 t tonnes over a period of 60±1 live days. The following evidences of recoiling electrons from interactions with; - Solar axions - Axion-like particles - Hidden photons - Solar neutrino magnetic moment - Solar neutrino millicharge are investigated in the study. Data reported here are from Science Run 1, which ran from 23 Dec 2021 to 11 May 2022 under stable detector conditions. Single-scatter (SS) reconstruction and analysis cuts are applied to data, and the region of interest (ROI) is defined as follows; - in the range of 3–80 phd for S1c. - in the range of uncorrected S2 greater than 600 phd and S2c less than 10^{5} phd for S2c.

Source record↗