Search NASA⌕ Search

SEARCH · Search NASA

Results for “STABLE OSCILLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Sub mm laser local oscillators: Design criteria and results

Diagnostic results are given of the spectral features and the power conversion efficiency of submillimeter (SMM) laser local oscillators. Several criteria are obtained for the design of frequency stable and efficient smm lasers for local oscillator applications. Finally, a design is described and results on the power output and power and frequency stability are given. The mode pattern is very close to a Gaussian profile so that efficient coupling to a quasioptical mixer is possible. The laser provides sufficient output power at a large number of lines to drive the mixer into the low conversion loss regime. Radiometric integration times of several minutes with a spectral resolution of 1 MHz will be possible. With present state-of-the-art Schottky mixers and low noise preamplifiers a radiometric temperature resolution of a few K can be expected over a spectral range from 500to 900 GHz.

Koepf, G. A.↗

Attitude stability of LDEF: Refinement of results from the silver pinhole camera

A measurement was previously described of the angular offset and attitude stability of the LDEF spacecraft using a simple pinhole camera device in the UAH experiment A0114. This device uses a silver surface to record the impact zone of atmospheric atomic oxygen passing through a small pinhole on the front surface of the satellite. The shape and size of this zone are well defined if the satellite velocity and gas temperature are known. The circular symmetry of the zone would be distorted by oscillation of the LDEF about its stable attitude, or by the effect of the co-rotation of the Earth's atmosphere for cases of satellites in nonequatorial orbits. The observed ellipticity of 1.05 with the major axis in the yaw direction is equivalent to an oscillation of + or - 0.2 deg about the stable attitude. The uncertainty in that measurement was estimated at about 0.1 deg. A refined analysis based on summing distributions of flux versus incidence angle for a large number of orbital positions, and including a co-rotating atmosphere, indicates that the combined distributions produce a result consistent with the measured exposed spot. It is suggested that, within the precision of the measurements, no actual oscillation of the LDEF is required to produce the results. Thus, the LDEF may have maintained a stable attitude to better than 0.1 deg, even under conditions of maximum aerodynamic perturbation when the silver oxygen record was made. This error is some two orders of magnitude lower than the predicted uncertainty in yaw oscillation and may indicate that the predict methodologies are too conservative.

Peters, P. N.↗

Population inversion X-ray laser oscillator

Oscillators are at the heart of optical lasers, providing stable, transform-limited pulses. Until now, laser oscillators have been available only in the infrared to visible and near-ultraviolet (UV) spectral region. In this paper, we present a study of an oscillator operating in the 5- to 12-keV photon-energy range. We show that, using the Kα 1 line of transition metal compounds as the gain medium, an X-ray free-electron laser as a periodic pump, and a Bragg crystal optical cavity, it is possible to build X-ray oscillators producing intense, fully coherent, transform-limited pulses. As an example, we consider the case of a copper nitrate gain medium generating ~ 5 × 10 10 photons per pulse with 37-fs pulse length and 48-meV spectral resolution at 8-keV photon energy. Our theoretical study and simulation of this system show that, because of the very large gain per pass, the oscillator saturates and reaches full coherence in four to six optical-cavity transits. We discuss the feasibility and design of the X-ray optical cavity and other parts of the oscillator needed for its realization, opening the way to extend X-ray–based research beyond current capabilities.

47 OTHER INSTRUMENTATION↗

Wein bridge oscillator circuit

Circuit with minimum number of components provides stable outputs of 2 to 8 volts at frequencies of .001 to 100 kHz. Oscillator exhibits low power consumption, portability, simplicity, and drive capability, it has application as loudspeaker tester and audible alarm, as well as in laboratory and test generators.

Lipoma, P. C.↗

Light Induced Microwave Oscillator

A novel oscillator that converts continuous light energy into stable and spectrally pure microwave signals is described. This Light Induced Microwave Oscillator (LIMO) consists of a pump laser and a feedback circuit including an intensity modulator, an optical fiber delay line, photodetector, amplifier, and a filter. A Quasi-linear theory is developed. Resulting expressions of parameters are given.

Microwave↗

Injection Locking of Gigahertz‐Frequency Surface Acoustic Wave Phononic Crystal Oscillator

Low-noise gigahertz (GHz) frequency sources are essential for applications in signal processing, sensing, and telecommunications. Surface acoustic wave (SAW) resonator-based oscillators offer compact form factors and low-phase noise due to their short mechanical wavelengths and high-quality (Q) factors. However, their small footprint makes them vulnerable to environmental variation, resulting in their poor long-term frequency stability. Injection locking is widely used to suppress frequency drift of lasers and oscillators by synchronizing to an ultra-stable reference. Here, injection locking of a 1-GHz SAW phononic-crystal oscillator is demonstrated, achieving 40-dB phase noise reduction at low offset frequencies and unperturbed low noise at large offset frequencies. Compared to a free-running SAW oscillator, which typically exhibits frequency drifts of several hundred hertz over minutes, the injection-locked oscillator reduces the frequency deviation to below 0.35 Hz. The locking range and oscillator dynamics is also investigated in the injection pulling region. The demonstrated injection-locked SAW oscillator could find applications in high-performance portable telecommunications and sensing systems.

injection locking↗

Thermal design and test results for SUNLITE ultra-stable reference cavity

SUNLITE (Stanford University-NASA Laser In-Space Technology Experiment) is a space-based experiment which uses a reference cavity to provide a stable frequency reference for a terahertz laser oscillator. Thermal stability of the cavity is a key factor in attaining a stable narrow-linewidth laser beam. The mount which is used to support and align the cavity will provide thermal isolation from the environment. The baseline requirement for thermal stability of the cavity is 0.025 C/min, but the design is directed toward achieving stability well beyond this requirement to improve the science data gained. A prototype of the cavity mount was fabricated and tested to characterize the thermal performance. The thermal vacuum test involved stable high-resolution temperature measurements and stable baseplate temperature control over long durations. Based on test data, the cavity mount design satisfies the severe requirement for the cavity thermal stability.

Amundsen, Ruth M.↗

Thermal analysis and test of SUNLITE reference cavity for laser frequency stabilization

SUNLITE is a space-based experiment which uses a reference cavity to provide a stable frequency reference for a terahertz laser oscillator. Thermal stability of the cavity is a key factor in attaining a stable narrow-linewidth laser beam. This paper describes the thermal stability requirements on the cavity design and detailed thermal analysis performed, as well as thermal testing that was performed on a prototype. Analytical thermal models were correlated to the test data and additional modeling of the current design is presented. Suggestions for improving similar high-precision thermal tests are given.

Amundsen, R. M.↗

Program Predicts Performance of Optical Parametric Oscillators

A computer program predicts the performances of solid-state lasers that operate at wavelengths from ultraviolet through mid-infrared and that comprise various combinations of stable and unstable resonators, optical parametric oscillators (OPOs), and sum-frequency generators (SFGs), including second-harmonic generators (SHGs). The input to the program describes the signal, idler, and pump beams; the SFG and OPO crystals; and the laser geometry. The program calculates the electric fields of the idler, pump, and output beams at three locations (inside the laser resonator, just outside the input mirror, and just outside the output mirror) as functions of time for the duration of the pump beam. For each beam, the electric field is used to calculate the fluence at the output mirror, plus summary parameters that include the centroid location, the radius of curvature of the wavefront leaving through the output mirror, the location and size of the beam waist, and a quantity known, variously, as a propagation constant or beam-quality factor. The program provides a typical Windows interface for entering data and selecting files. The program can include as many as six plot windows, each containing four graphs.

Cross, Patricia L.↗

Entanglement and correlations in fast collective neutrino flavor oscillations

Collective neutrino oscillations play a crucial role in transporting lepton flavor in astrophysical settings like supernovae and neutron star binary merger remnants, which are characterized by large neutrino densities. In these settings, simulations in the mean-field approximation show that neutrino-neutrino interactions can overtake vacuum oscillations and give rise to fast collective flavor evolution on time-scales t ∝ μ –1 , with μ proportional to the local neutrino density. In this work, we study the full out-of-equilibrium flavor dynamics in simple multi-angle geometries displaying fast oscillations in the mean field linear stability analysis. Focusing on simple initial conditions, we analyze the production of pair correlations and entanglement in the complete many-body-dynamics as a function of the number N of neutrinos in the system, for up to thousands of neutrinos. Similarly to simpler geometries with only two neutrino beams, we identify three regimes: stable configurations with vanishing flavor oscillations, marginally unstable configurations with evolution occurring on long time scales τ ≈ µ –1 $\sqrt{N}$, and unstable configurations showing flavor evolution on short time scales τ ≈ μ –1 log(N). Here, we present evidence that these fast collective modes are generated by the same dynamical phase transition which leads to the slow bipolar oscillations, establishing a connection between these two phenomena and explaining the difference in their time scales. We conclude by discussing a semi-classical approximation which reproduces the entanglement entropy at short to medium time scales and can be potentially useful in situations with more complicated geometries where classical simulation methods starts to become inefficient.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Oscillation Amplitude Growth for a Decelerating Object with Constant Pitch Damping

The equations governing the deceleration and oscillation of a blunt body moving along a planar trajectory are re-expressed in the form of the Euler-Cauchy equation. An analytic solution of this equation describes the oscillation amplitude growth and frequency dilation with time for a statically stable decelerating body with constant pitch damping. The oscillation histories for several constant pitch damping values, predicted by the solution of the Euler-Cauchy equation are compared to POST six degree-of-freedom (6-DoF) trajectory simulations. The simulations use simplified aerodynamic coefficients matching the Euler-Cauchy approximations. Agreement between the model predictions and simulation results are excellent. Euler-Cauchy curves are also fit through nonlinear 6-DoF simulations and ballistic range data to identify static stability and pitch damping coefficients. The model os shown to closely fit through the data points and capture the behavior of the blunt body observed in simulation and experiment. The extracted coefficients are in reasonable agreement with higher fidelity, nonlinear parameter identification results. Finally, a nondimensional version of the Euler-Cauchy equation is presented and shown to be a simple and effective tool for designing dynamically scaled experiments for decelerating blunt capsule flight.

Schoenenberger, Mark↗

LC-oscillator with automatic stabilized amplitude via bias current control

A stable excitation supply for measurement transducers is described. It consists of a single-transistor oscillator with a coil connected to the collector and a capacitor connected from the collector to the emitter. The output of the oscillator is rectified and the rectified signal acts as one input to a differential amplifier; the other input being a reference potential. The output of the amplifier is connected at a point between the emitter of the transistor and ground. When the rectified signal is greater than the reference signal, the differential amplifier produces a signal of polarity to reduce bias current and, consequently, amplification.

Hamlet, J. F.↗

Simple JFET oscillator

Device used in mixers, modulators, and function generators provides stable sine-wave signal compatible with both integrated circuits and discrete-component assemblies. Oscillator's frequency is tunable over narrow band about design value. Frequency range, stability, linearity, and low power drain of device are suited to communications receivers and transmitters and digital microprocessors, computers, and displays. Circuit simplicity allows for easy monolithic construction.

Kleinberg, L. L.↗

Nonlinear Dynamic Models in Advanced Life Support

To facilitate analysis, ALS systems are often assumed to be linear and time invariant, but they usually have important nonlinear and dynamic aspects. Nonlinear dynamic behavior can be caused by time varying inputs, changes in system parameters, nonlinear system functions, closed loop feedback delays, and limits on buffer storage or processing rates. Dynamic models are usually cataloged according to the number of state variables. The simplest dynamic models are linear, using only integration, multiplication, addition, and subtraction of the state variables. A general linear model with only two state variables can produce all the possible dynamic behavior of linear systems with many state variables, including stability, oscillation, or exponential growth and decay. Linear systems can be described using mathematical analysis. Nonlinear dynamics can be fully explored only by computer simulations of models. Unexpected behavior is produced by simple models having only two or three state variables with simple mathematical relations between them. Closed loop feedback delays are a major source of system instability. Exceeding limits on buffer storage or processing rates forces systems to change operating mode. Different equilibrium points may be reached from different initial conditions. Instead of one stable equilibrium point, the system may have several equilibrium points, oscillate at different frequencies, or even behave chaotically, depending on the system inputs and initial conditions. The frequency spectrum of an output oscillation may contain harmonics and the sums and differences of input frequencies, but it may also contain a stable limit cycle oscillation not related to input frequencies. We must investigate the nonlinear dynamic aspects of advanced life support systems to understand and counter undesirable behavior.

Jones, Harry↗

Integrating Data Centers and Grid Technologies at Scale

This presentation focuses on the challenge of integrating AI-driven data centers with the power grid at scale. It examines the AI data center capacity challenge and the role of new Medium Voltage Direct Current (MVDC) and other grid-enhancing technologies in enabling efficient and reliable power delivery. The session will highlight the National Laboratory of the Rockies' ARIES capabilities and planning tools, along with collaborative examples involving Verrus, Compass, and Schneider through the Agora test bed for grid-friendly data center evaluations, and ON. Energy for UPS evaluation. It will showcase the NLR Stable Grid Platform for studying oscillations caused by large-scale data centers, along with planning tools to assess grid security and reliability. Additionally, the presentation covers reconductoring strategies to increase grid capacity and explores innovative data center architectures, including the Advanced DC Architectures with Power-electronic Transformers (ADAPT) platform, which enables testing of complete DC architectures for data centers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fundamental mode oscillation of a buried ridge waveguide laser array

An eight-element phase-locked array of index-guided separate confinement ridge AlGaAs diode lasers is fabricated. In this array the absorption of light in the region between lasers is negligible and the gain profile across the array is nearly uniform. Unlike most other arrays, this array oscillates in its fundamental mode. Stable radiation patterns of near diffraction-limited single narrow beam with 1.6 deg width are obtained. The beam width approaches the theoretical limit for the present array structure.

Mukai, S.↗

Geologic periodicities and the Galaxy

New geologic and astronomical developments are reviewed that have recently led to the proposal of various Galactic theories to explain the temporal pattern of impact craters on earth. Linear and harmonic time series analyses have revealed that two dominant periodicities about equal to 33 + or - 3 Myr and 260 + or - 25 Myr underlie the geologic record of terrestrial impact cratering and global tectonic phenomena. It is argued that purely terrestrial mechanisms cannot account for the cratering cycles as being preservational artifacts; cratering rather appears to influence tectonism, possibly through perturbations of mantle convection. Galactic models proposed to explain the two long-term periodicities are reviewed critically. The most likely explanation for the 33 Myr cycle involves the comparatively stable half period of vertical oscillation of the solar system about the Galactic plane. The 260 Myr cycle may be related to rare encounters with Galactic spiral arms during the revolution of the solar system around the Galactic center.

Rampino, Michael R.↗

The role of time and speed in NASA's SUNLITE program

The SUNLITE program of NASA's LaRC aims to demonstrate lower noise and better frequency stability for continuous-wave (CW) solid-state lasers in the microgravity environment of space. The program will utilize laser-diode-pumped nonplanar-ring oscillators regulated by ultra-stable high-finesse Fabry-Perot Spectrometers to produce light beams with phase rate or frequency variations as low as 3 Hz. SUNLITE will use the period-method (P-method) to measure the phase rate and frequency stability of the lasers. The P-method was chosen because it requires less memory space for the raw data, because frequencies can be analyzed on-line in real-time simply by reciprocating the periods (fi = 1/pi), and because the mean and variance of the frequencies can be calculated as fast or faster than they can be with the fastest fast Fourier transformations. Furthermore, for a given signal-to-noise power ratio, the P-method requires less data and less computer time to extract the noise components. Although the P-method does require fast Time Interval Counters, the Fourier transformation method requires comparably fast Sampling Volt meters. For either method, however, time and computer speed play a critical role.

Hafele, Joseph C.↗