At least 181 records · Page 10

Modeling of Radiative Heating in Base Region of Jovian Entry Probe

A theoretical model is derived to determine the average thermodynamic properties in the expanding region, recirculating region, recompression region, and neck region through application of one-dimensional conservation equations. Radiative transfer is calculated using spectrally detailed computer codes accounting for nonequilibrium. The results show that the most severe heating occurs immediately behind the frustum, and that the recompression and neck regions are the major sources of radiation that heats the base stagnation point, The radiation flux to the base point is slightly stronger with ablation than without. Its value is 0.11(43 P(sub b)/P(sub s))(sup 2) times that to the front stagnation point where the base pressure P(sub b) is defined as the average pressure in the recirculating region and P(sub s) is the front stagnation-point pressure. The time-integrated heat load to the base point is 18(43 P(sub b)/P(sub s))(sup 2) kJ/sq cm.

Park, Chul↗

Electron Distribution Functions in the Diffusion Region of Asymmetric Magnetic Reconnection

We study electron distribution functions in a diffusion region of antiparallel asymmetric reconnection by means of particle-in-cell simulations and analytical theory. At the electron stagnation point, the electron distribution comprises a crescent-shaped population and a core component. The crescent-shaped distribution is due to electrons coming from the magnetosheath toward the stagnation point and accelerated mainly by electric field normal to the current sheet. Only a part of magnetosheath electrons can reach the stagnation point and form the crescent-shaped distribution that has a boundary of a parabolic curve. The penetration length of magnetosheath electrons into the magnetosphere is derived. We expect that satellite observations can detect crescent-shaped electron distributions during magnetopause reconnection.

Electron↗

Arc Jet Facility Test Condition Predictions Using the ADSI Code

The Aerothermal Design Space Interpolation (ADSI) tool is used to interpolate databases of previously computed computational fluid dynamic solutions for test articles in a NASA Ames arc jet facility. The arc jet databases are generated using an Navier-Stokes flow solver using previously determined best practices. The arc jet mass flow rates and arc currents used to discretize the database are chosen to span the operating conditions possible in the arc jet, and are based on previous arc jet experimental conditions where possible. The ADSI code is a database interpolation, manipulation, and examination tool that can be used to estimate the stagnation point pressure and heating rate for user-specified values of arc jet mass flow rate and arc current. The interpolation is performed in the other direction (predicting mass flow and current to achieve a desired stagnation point pressure and heating rate). ADSI is also used to generate 2-D response surfaces of stagnation point pressure and heating rate as a function of mass flow rate and arc current (or vice versa). Arc jet test data is used to assess the predictive capability of the ADSI code.

fluid dynamics↗

The heating environment during Martian atmospheric descent

It has been shown that a vehicle with a lift/drag ratio of 2.3 entering the Martian atmosphere at parabolic speed of 5 km/sec, or from a low orbit at 3.5 km/sec, has a very large landing footprint. At the 5-km/sec entry speed, the trajectory exhibits large skipping motions; however, a lateral range of up to 3300 km is attainable. The entries from low satellite orbit yield a gliding lateral range of 2500 km. The distances correspond to latitude changes of 57 and 42 deg, respectively. The high-speed, skipping entries were accompanied by the most intense heating. The peak stagnation point convective rates varied from 59 W/sq cm to 88 W/sq cm for partially and fully catalytic walls, respectively; the corresponding equilibrium wall temperatures were 1900 K and 2100 K. The peak heating at a wing leading-edge point reached 50 W/sq cm because of the presence of a transitional boundary layer. The lower-speed, gliding entries experienced much milder heating with a peak stagnation point rate of about 14 W/sq cm, resulting in a wall temperature near 1300 K. However, the longer duration of the gliding entries resulted in comparable heat loads for both entry speeds. The highest heat loads approached values experienced by the Shuttle orbiter stagnation point during a typical entry.

Tauber, Michael E.↗

Influence of thermal boundary conditions on heat transfer from a cylinder in cross flow

Local heat transfer data over the leading surface of a cylinder in crossflow were obtained for a Reynolds number range of 50,000. The cylinder was operated at both uniform-wall-temperature and uniform-heat-flux thermal ance of 80 deg from the front stagnation point, the uniform-wall-temperature heat transfer coefficients were as much as 66 percent lower than the uniform-heat-flux data. Between the stagnation point and 60 deg around the cylinder, there were no significant differences in the data. This region of the cylinder is within the cylindrical curvature region of the front end of a real turbine so it was concluded that either thermal boundary condition could be used to model turbine flow over that region of the blade. Results of evaluating the exponent x in the fundamental relationship Nu=f(Re) sup x, which is used in data correlation show the exponent varies as a function of local position on the cylinder even in the laminar flow region. The value of x increases linearly from 0.50 at the stagnation point to 0.59 at 60 deg around the cylinder. This linear trend continued into the separation region at 80 deg for the uniform-wall-temperature data, but x increased markedly in the separation region for the uniform-heat-flux data.

Papell, S. S.↗

Subsonic magnetosheath observations from Explorer 33

Data are presented from one orbit of Explorer 33 which entered the magnetosphere near the stagnation point. Magnetic activity as measured at the earth was relatively quiet during the orbit, although minor substorm activity began 2 hours prior to the boundary crossing. Well before entry, the magnetosheath observations show flow patterns consistent with hydrodynamic models. Near the stagnation point close to the boundary the observations show rapid variations between virtually isotropic flux (stagnated flow) and flows tangent to the boundary in alternately opposite directions. Movement of the stagnation point of the order of 1 earth radius is inferred from these observations. Multiple boundary crossings are observed in the magnetic field covering a thickness of about 500 km. Prior to the magnetic crossings, the higher-energy proton fluxes begin to disappear. The bulk of the protron flux in the lower energy ranges and also the electron flux decrease rapidly at the last magnetic crossing. No boundary is apparent in the highest energy range measured by the detector.

Crooker, N. U.↗

Aerothermal Analysis of the Rocket Lab Venus Probe Heatshield

This document provides an overview of the aerothermodynamic analyses performed by the Aerothermodynamics Branch at NASA Langley Research Center for the Rocket Lab Venus Probe (RLVP). In addition to defining the baseline heating environment to the heatshield, this document pursues the experimental validation of key physical models at RLVP-relevant conditions. This experimental validation analysis, which captures the model form uncertainty, is used as one of two primary components of the margin assessment, where the other component is the parametric uncertainty. These model form (experimental) and parametric uncertainty components are used to construct a spatial and time varying margin for the heating to the RLVP heatshield. The margin is evaluated as the sum of the parametric and model form uncertainty components. The model form uncertainty is defined as the difference between the RLVP-relevant measurements and their simulations, using the upper limit uncertainty bounds for both the measurements and simulations in the comparisons. The differences in the dominant physics in the stagnation region and flank lead to the separate RLVP-relevant measurements for assessing the model form uncertainty in these two regions. These regions are addressed as follows: Stagnation Region Heating Environment: For the high-temperature stagnation-region, both the radiative heating and impact of blowing on convective heating are significant, while the impacts of turbulence and roughness are negligible. Coupled radiation and ablation LAURA/HARA solutions with ray-tracing provide the radiative heating over the entire vehicle, including the contributions from the Venus atmosphere and ablation species. Non-ablating LAURA simulations provide the convective heating. During the material-response computation typically used for TPS sizing, this non-ablating convective heating is corrected for the impact of ablation using the blowing correction. Coupled ablation LAURA simulations that capture finite-rate sur-face processes show that this blowing correction may be non-conservative over most of the heatshield. This non-conservatism is due to hydrogen recombination in the finite-rate surface model, which tends to increase the coupled ablation convective heating to near the non-ablating values, therefore making any reduction in the non-ablating value through the blowing correction non-conservative. This non-conservatism due to H catalysis is captured in the parametric component of the margin. The best available ground-test measurements that capture the impact of blowing on stagnation region convective heating, at RLVP-relevant conditions, indicate that the current blowing reduction model is non-conservative by up to 20% at RLVP-relevant blowing rates (the coupled blowing simulations were also non-conservative). Because of the relatively low velocity of the ground tests and the non-Venus atmospheric chemistry, these measurements do not capture the chemistry and therefore do not inform the uncertainty due to H catalysis. However, they do capture the fluid mechanics of blowing. The non-conservatism of the blowing correction implied by these measurements is covered by the model form component of the margin, which leads to total margin values over 50%. For the radiative heating, the shock-tube informed bias approach suggests a model form uncertainty of roughly 20%, while the parametric uncertainty analysis suggests values over 100%. The combined stagnation-point radiation margin of over 100% leads to peak margined radiative heating values of over300 W/cm2, which remains small relative to the peak margined convective heating of nearly 2000 W/cm2. Based on this analysis, at the stagnation point, the peak margined heat rate is 2203 W/cm2 and the margined total heat load is 31.5 kJ/cm2 for the current nominal trajectory. Flank Heating Environment: The forebody flank (and near-shoulder) heating environment is dominated by the impact of turbulence, roughness augmentation, and ablation on the convective heating. An extensive collection of ground test measurements with RLVP-relevant turbulence and roughness is studied to show that the maximum difference between the simulated and measured convective heating is 5%. However, with the exception of the Holden measurements from the 1980s, these measurements do not include roughness elements extending into the supersonic region of the boundary layer, which is likely to occur for RLVP (due to the 45 degree sphere-cone geometry). The interaction between the supersonic flow and roughness could cause convective heating augmentation fundamentally different than for locally subsonic flow. Although these Holden measurements are consistent with the other measurements considered, another path was pursued to assure that the rough-ness height extending into supersonic flow does not fundamentally change the roughness augmentation. This additional path was a computational effort to resolve the roughness elements in the CFD grid, so that the interaction be-tween the roughness elements and locally supersonic flow may be simulated in detail. This roughness-resolved CFD simulation is feasible because of the RLVP forebody TPS’s patterned roughness, which may be approximated analytically, and because of the axisymmetric nominal flow field, which allows a narrow surface region to be simulated and therefore make the computational expense feasible. These grid-resolved roughness simulations, which are performed at actual RLVP flight conditions, result in heating augmentation values that are below the design approach for roughness augmentation. This provides evidence that the design approach for RLVP roughness augmentation is sufficient. Based on this analysis, at this flank or near-shoulder location, the peak margined total heat rate is 2088 W/cm2and the margined total heat load is 26.0 kJ/cm2for the current nominal trajectory. Heat flux, shear, pressure and heat transfer coefficient at the RLVP stagnation point and near shoulder location are evaluated for the entire trajectory, and curved fit to a functional form of F=AρB∞UC∞. These simplified relationships for the nominal and margined aerothermal environments are referred to as aerothermal indicators, and presented at the end of this document.

Christopher O Johnston↗

Experimental studies of radiative base heating of a Jovian entry model

A scale model of the Jovian entry vehicle of 6.4 cm diameter is tested in an electric-arc-driven shock tube while a sphere model of 5 cm diameter is tested in a combustion-driven shock tube and an electric-arc-driven shock tunnel. The radiative heat-transfer rate and pressure on the front and the base regions are measured in the absence of ablation with sensors imbedded in the models in a stream consisting of 10% hydrogen in a bath of either neon or argon. The measured radiative heat-transfer rates and pressures are up to about 22 kW/sq cm and 12 atm, respectively, at the front stagnation point. The ratio of the base-to-stagnation-point radiative heat-transfer rates is found to be about 1/4 for the sphere at Mach 1.8, about 1/30 for the sphere at Mach 4.8, and about 1/6 for the scale model at Mach 1.7. When the effects of model geometry and Mach number are accounted for, the present experimental results agree well with the theoretical prediction of Park.

Shirai, H.↗

Ames Research Center Mars/Pathfinder Heat Shield Design Verification ARC-JET Test

Design verification tests were performed on samples representing the aerobrake of the Mars/Pathfinder vehicle. The test specimens consisted of the SLA-561V ablator bonded to the honeycomb structure. The primary objective was to evaluate the ablation materials performance and to measure temperatures within the ablator, at the structural bondline and at the back sheet of the honeycomb structure. Other objectives were to evaluate the effect of ablative repair plug material treatment and voids in the heat shield. A total of 29 models were provided for testing in the Ames 60MW arc-jet facility. Of these, 23 models were flat-faced and six remaining models were curved edge ones, intended to simulate the conditions on the curved rim of the forebody where the maximum shear occurred. Eight sets of test conditions were used. The stagnation point heating rates varied from 47 to 240 W/cm2 and the stagnation pressures from 0.15 to 0.27 atm. (The maximum flight values are 132 W/cm2 and 0.25 atm) The majority of these runs were made at a nominal stagnation pressure of 0.25 atm. Two higher pressure runs were made to check the current (denser) ablation material for spallation, or other forms of thermal stress failure. Over 60% of the flatfaced models yielded good thermocouple data and all produced useful surface recession information. Of the five curved-edge models that were tested, only one gave good data; the remaining ones experienced model-holder failure. The test results can be summarized by noting that no failure of the ablative material was observed on any model. Also, the bondline temperature design limit of 250 C was never reached within an equivalent flight time despite a stagnation point heat load that exceeded the maximum flight value by up to 130%. At heating rates of over 200W/cm2 and stagnation pressures of 0.25 atm, or greater, the average surface recessions exceeded 0.5 cm on some models. The surface roughness increased dramatically at pressures above 0.25 atm and was four times greater at 0.27 atm than at 0.25 atm. Procured repair plug material performed much better than room-temperature cured plugs, as observed in the previous tests. Voids in the ablator did not increase local temperatures and gaps did not grow during testing.

Tran, Huy K.↗

Trajectory characteristics and heating of hypervelocity projectiles having large ballistic coefficients

A simple, approximate equation describing the velocity-density relationship (or velocity-altitude) has been derived from the flight of large ballistic coefficient projectiles launched at high speeds. The calculations obtained by using the approximate equation compared well with results for numerical integrations of the exact equations of motion. The flightpath equation was used to parametrically calculate maximum body decelerations and stagnation pressures for initial velocities from 2 to 6 km/s. Expressions were derived for the stagnation-point convective heating rates and total heat loads. The stagnation-point heating was parametrically calculated for a nonablating wall and an ablating carbon surface. Although the heating rates were very high, the pulse decayed quickly. The total nose-region heat shield weight was conservatively estimated to be only about 1 percent of the body mass.

Tauber, Michael E.↗

Measurements of Heat Transfer and Boundary-Layer Transition on an 8-Inch-Diameter Hemisphere-Cylinder in Free Flight for a Mach Number Range of 2.00 to 3.88

Measurements of aerodynamic heat transfer have been made along the hemisphere and cylinder of a hemisphere-cylinder rocket-propelled model in free flight up to a Mach number of 3.88. The test Reynolds number based on free-stream condition and diameter of model covered a range from 2.69 x l0(exp 6) to 11.70 x 10(exp 6). Laminar, transitional, and turbulent heat-transfer coefficients were obtained. The laminar data along the body agreed with laminar theory for blunt bodies whereas the turbulent data along the cylinder were consistently lower than that predicted by the turbulent theory for a flat plate. Measurements of heat transfer at the stagnation point were, in general, lower than the theory for stagnation-point heat transfer. When the Reynolds number to the junction of the hemisphere-cylinder was greater than 6 x l0(exp 6), the transitional Reynolds number varied from 0.8 x l0(exp 6) to 3.0 x 10(exp 6); however, than 6 x l(exp 6) when the Reynolds number to the junction was less, than the transitional Reynolds number varied from 7.0 x l0(exp 6) to 24.7 x 10(exp 6).

Garland, Benjamine J.↗

Measurements of Local Heat Transfer and Pressure on Six 2-Inch-Diameter Blunt Bodies at a Mach Number of 4.95 and at Reynolds Numbers Per Foot up to 81 x 10(exp 6)

Measurements of the local heat transfer and pressure distribution have been made on six 2-inch-diameter, blunt, axially symmetric bodies in the Langley gas dynamics laboratory at a Mach number of 4.95 and at Reynolds numbers per foot up to 81 x 10(exp 6). During the investigation laminar flow was observed over a hemispherical-nosed body having a surface finish from 10 to 20 microinches at the highest test Reynolds number per foot (for this configuration) of 77.4 x 10(exp 6). Though it was repeatedly possible to measure completely laminar flow at this Reynolds number for the hemisphere, it was not possible to observe completely laminar flow on the flat-nosed body for similar conditions. The significance of this phenomenon is obscured by the observation that the effects of particle impacts on the surface in causing roughness were more pronounced on the flat-nosed body. For engineering purposes, a method developed by M. Richard Dennison while employed by Lockheed Aircraft Corporation appears to be a reasonable procedure for estimating turbulent heat transfer provided transition occurs at a forward location on the body. For rearward-transition locations, the method is much poorer for the hemispherical nose than for the flat nose. The pressures measured on the hemisphere agreed very well with those of the modified Newtonian theory, whereas the pressures on all other bodies, except on the flat-nosed body, were bracketed by modified Newtonian theory both with and without centrifugal forces. For the hemisphere, the stagnation-point velocity gradient agreed very well with Newtonian theory. The stagnation-point velocity gradient for the flat- nosed model was 0.31 of the value for the hemispherical-nosed model. If a Newtonian type of flow is assumed, the ratio 0.31 will be independent of Much number and real-gas effects.

Cooper, Morton↗

Streamline-based microfluidic device

The present invention provides a streamline-based device and a method for using the device for continuous separation of particles including cells in biological fluids. The device includes a main microchannel and an array of side microchannels disposed on a substrate. The main microchannel has a plurality of stagnation points with a predetermined geometric design, for example, each of the stagnation points has a predetermined distance from the upstream edge of each of the side microchannels. The particles are separated and collected in the side microchannels.

Tai, Yu-Chong↗

Measurement of Attachment-Line Location in a Wind-Tunnel and in Supersonic Flight

As a part of the supersonic laminar flow control research program, experiments are being conducted to measure the attachment-line flow characteristics and its location on a highly swept aircraft wing. Initially, subsonic wind tunnel tests were performed on two-dimensional models to develop sensors and techniques for the flight application. The wind tunnel test results suggest that, under certain conditions at the leading edge there are low frequency streamwise velocity fluctuations present in the laminar boundary layer which undergo a phase change at the stagnation point Therefore, if present in flight, this distinct change in phase, i.e., time shift of signals from either side of the stagnation point, can be used to determine the stagnation-line or attachment-line location. The phase-reversal phenomenon was examined to determine the attachment-line location on a highly swept wing. Test results indicate that the phase-reversal phenomenon may not be applicable in flight. Additional data analyses is continuing to account for phase differences introduced by the recording system. A final determination on the existence of phase-reversal in flight will require the results of further analysis and possibly additional flight testing. Some representative attachment-line data are presented and discussed as well as the results from the wind tunnel investigation.

Flight Testing↗

Blockage effects in the chemotaxis of diffusiophoretic particles

Transport mechanisms at the micro- and nano-scale play an essential role in regulating intracellular organization. Recent work indicates that directed motion of constituents inside cells can emerge through diffusiophoretic transport, in which colloidal particles move under the influence of chemical gradients. Here, we examine how blockers—passive or actively consuming—reshape those gradients and thereby influence the motion of diffusiophoretic particles. By combining analytical solutions with finite element simulations, we first show that a single blocker can distort a background gradient enough to create or eliminate stagnation points, significantly modifying particle transport. We then introduce a second, explicitly sized blocker at one of these stagnation points and measure how its finite radius alters the diffusiophoretic velocity field for a test particle. Even moderate changes in the second blockers size can cause noticeable shifts in the substrate distribution, highlighting the importance of accounting for explicit particle radii under crowded or consumption-driven conditions. Our findings underscore that subtle geometric variations—such as the radii and positions of two or more blockers—can profoundly affect diffusiophoretic motion, providing a more complete picture of how blocking and crowding phenomena shape intracellular transport.

Song, Zehao [Northwestern Univ., Evanston, IL (Uni↗

Stagnation Temperature Recording

The present report deals with the development of a thermometer for recording stagnation temperature in compressible mediums in turbulent flow within 1 to 2 percent error of the adiabatic temperature in the stagnation point, depending upon the speed. This was achieved by placing the junction of a thermocouple near the stagnation point of an aerodynamically beneficial body, special care being taken to assure an uninterrupted supply of fresh compressed air on the junction together with the use of metals of low thermal conductivity, thus keeping heat-transfer and heat-dissipation losses to a minimum. In other experiments the use of the plate thermometer was proved unsuitable for practical measurements by reason of its profound influence in the reading by the Reynolds number and by the direction of flow.

Wimmer, W↗

Recent improvements in the nonequilibrium VSL scheme for hypersonic blunt-body flows

The nonequilibrium viscous shock-layer (VSL) solution scheme is revisited to improve its solution accuracy in the stagnation point region and also to minimize and control the errors in the conservation of elemental mass. The stagnation-point solution is improved by using a second-order expansion for the normal velocity and the elemental mass conservation is improved by directly imposing the element conservation equations as solution constraints. These modifications are such that the general structure and computational efficiency of the nonequilibrium VSL scheme is not affected. This revised nonequilibrium VSL scheme is used to study the Mach 20 flow over a 7-deg sphere-cone vehicle under zero and 20-deg angle-of-attack conditons. Comparisons are made with the corresponding predictions of Navier-Stokes and Parabolized Navier-Stokes solution schemes. The results of these tests show that the nonequilibrium blunt-body VSL scheme is indeed an accurate, fast and extremely efficient means for generating the blunt-body flowfield over spherical nosetips at small-to-large angles of attack.

Bhutta, Bilal A.↗

The stability of laminar flow past a sphere

As a contribution to the problem of turbulence on a surface of rotation, the method of small oscillation is applied to the flow past a sphere. It was found that the method developed for two-dimensional flow is applicable without modifications. The frictional layer in the vicinity of the stagnation point of a surface of rotation is less stable against small two-dimensional disturbances than in the stagnation point itself, as proved from an analysis of the velocity distribution made by Homann.

Pretsch, J↗