Search NASA⌕ Search

SEARCH · Search NASA

Results for “Safety Performance Indicators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Effect of the neutral beam injector operational regime on the Alfven eigenmode saturation phase in DIII-D plasma

The aim of this study is to analyze the effect of the neutral beam injector (NBI) operation regime on the saturation phase of the Alfven Eigenmodes (AEs) in DIII-D plasma. Here, the analysis is done using the linear and nonlinear versions of the gyro-fluid code FAR3d. A set of parametric analyses are performed modifying the nonlinear simulation EP $β$ (NBI injection power), EP energy (NBI voltage) and the radial location of the EP density profile gradient (NBI radial deposition). The analysis indicates a transition from the soft (local plasma relaxation) to the hard MHD (global plasma relaxation) limit if the simulation EP $β$ $\unicode{x2A7E}$ $0.02$, leading to bursting MHD activity caused by radial AEs overlapping. MHD bursts cause an enhancement of the EP transport showing ballistic-like features as avalanche-like events. Simulations in the soft MHD limit show an increment of the EP density gradient as the EP $β$ increases. On the other hand, there is a gradient upper limit in the hard MHD limit, consistent with the critical-gradient behavior. AEs induce shear flows and zonal current leading to the deformation of the flux surfaces and the safety factor profile, respectively, particularly strong for the simulation in the hard MHD limit. Simulations in the hard MHD regime show a decrease of the AE frequency in the saturation phase; this is caused by the destabilization of a transitional mode between a $9/3-10/3$ TAE and a $9/3$ RSAE that may explain the AE frequency down-sweeping observed in some DIII-D discharges. Reducing the EP energy in the nonlinear simulations leads to a weakening of the plasma perturbation. On the other hand, increasing the EP energy causes the opposite effect. Nonlinear simulations of off-axis NBI profiles indicate a lower plasma perturbation as the EP density gradient is located further away from the magnetic axis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrating Electromagnetic Acoustic Transducers in a Modular Robotic Gripper for Inspecting Tubular Components

Tubular structures are critical components in infrastructure such as power plants. Throughout their life, they are subjected to extreme conditions or suffer from defects such as corrosion and cracks. Although regular inspection of these components is necessary, such inspection is limited by safety-related risks and limited access for human inspection. Robots can provide a solution for automatic inspection. The main challenge, however, lies in integrating sensors for nondestructive evaluation with robotic platforms. As part of developing a versatile lizard-inspired tube inspector robot, in this study the authors propose to integrate electromagnetic acoustic transducers into a modular robotic gripper for use in automated ultrasonic inspection. In particular, spiral coils with cylindrical magnets are integrated into a novel friction-based gripper to excite Lamb waves in thin cylindrical structures. To evaluate the performance of the integrated sensors, the gripper was attached to a robotic arm manipulator and tested on pipes of different outer diameters. Two sets of tests were carried out on both defect-free pipes and pipes with simulated defects, including surface partial cracking and corrosion. The inspection results indicated that transmitted and received signals could be acquired with an acceptable signal-to-noise ratio in the time domain. Moreover, the simulated defects could be successfully detected using the integrated robotic sensing system.

Materials Science↗

Simulation Results of a Thermal Power Dispatch System from a Generic Pressurized Water Reactor in Normal and Abnormal Operating Conditions

Amid economic pressures in the U.S. electricity market, nuclear utilities are exploring new revenue streams, including hydrogen production. A generic pressurized water reactor simulator was modified to incorporate a novel design for a TPD system coupled to a hydrogen production plant. Standard malfunctions were included in the simulation design, including steam line breaks at various system locations and flow interruptions in the hydrogen plant due to multiple faults, reflecting anticipated operational challenges. It is imperative that the TPD system operation has a minimal effect on the reactor power, primary coolant system, and turbine system operation and performance. Due to the specific design and application of this TPD system, with the proposed turbine control system changes, the overall impact on the existing plant systems is low. Normal TPD operating scenarios resulted in minor effects on the existing plant systems: reactor power changes by at most 0.2%, and gross generator output changes by 20.5 MWe from 100 MWt of TPD. The most severe malfunction analyzed in this work is a full TPD steam line break downstream of the extraction location, which results in an increase in reactor power of about 0.5%. The gross generator output decreases by 36 MWe, a total decrease of 60 MWe from the full power steady state (FPSS) condition. These results indicate that an industrial hydrogen production plant could be coupled thermally to a nuclear power plant with limited effects on the existing system operation and safety.

08 HYDROGEN↗

Safe Operations at Roadway Junctions: Intelligent Roadway Infrastructure as Functional Interlocking

Automated vehicle (AV) technology is quickly maturing, and the corresponding infrastructure systems that evaluate traffic and communicate to vehicles requires sophisticated sensing and perception technologies, referred to as intelligent roadway infrastructure (IRI), to complement emerging AV capabilities. IRI provides signals to vehicles, indicating right-of-way for vehicles and communicating to approaching AVs that no other vehicle is failing to yield. This capability, denoted as safety-affirmative signaling, provides a green light or a green arrow as appropriate and affirms through communication links to connected vehicles when it is safe to proceed. About 36% of collisions occur at intersections, with most occurring upon left turns (22.2%) or crossing over (12.6%), and only a small percentage (1.2%) while turning right at an intersection. Of all intersection crashes about half (52.5%) of those vehicles were traveling through a signalized intersection 2. Safety-affirmative signaling would guarantee safety of AV fleet vehicles, by providing the interlocking principle, a term from automated train control that only allows progression through a railway intersection after affirming no opportunity for a crash exists. IRI through safety-affirmative signaling would bring performance and safety to complex roadway intersections where AV transit fleet service is most needed, as well as safety benefits to traditional, non-automated vehicles and vulnerable road users. The implementation of IRI has functional, programmatic, and technical challenges. Research work performed at the National Renewable Energy Laboratory (NREL) in an integrative approach encapsulating these themes, and termed infrastructure perception and control (IPC) is motivated by improved performance (travel time), improved safety (reduced collisions), and improved energy efficiency (less fuel burned and minimized production of greenhouse gases). IPC is intended not only for roadway and intersection applications but also in extension to inform complementary buildings and grid systems to enable better co-management, as vehicles and their charging needs become increasingly integrated into the built environment. The NREL IPC project presents an open-source framework, architecture, and supporting technology to implement IRI, addressing critical issues such as fusion of data, reliability, standardization of data interfaces, and confidence of detection. The framework is informed by previous experience in U.S. Department of Defense research technology, specifically in the use of radar to detect, identify, and track aerial threats. These principles combined with multi-sensor fusion provides for a complete digital twin with known and measurable confidence and accuracy from which safety-affirmative signaling can be developed and deployed.

ADVANCED PROPULSION SYSTEMS,MATHEMATICS AND COMPUT↗

Deuterium transport and retention properties of representative fusion blanket structural materials

Reduced activation ferritic-martensitic (RAFM) steels have been developed for decades for use as fusion blanket structural materials, and have advantages in both mechanical properties and irradiation resistance following careful engineering of the microstructure. However, the hydrogen isotope behavior in these proposed fusion structural materials is not well understood, but is important to assess since it impacts the fusion reactor safety and self-sufficient tritium fuel cycle. Here, we investigated deuterium transport and retention in representative advanced RAFM steels, including castable nanostructured alloys (CNAs), and oxide-dispersion-strengthened (ODS) steels. A gas-driven permeation (GDP) system was used to measure the permeability, diffusivity and solubility of the studied materials, covering the temperature range from 623 K to 873 K, and the loading pressures from 1.8 x 10 4 to 1.0 x 10 5 Pa. The results indicated that the deuterium permeability has little material dependence. In contrast, the deuterium diffusivity of the studied materials showed significant variation. The deuterium diffusivity in ODS steels is one order of magnitude lower than that in RAFM steels and CNAs, and correspondingly, have an effective solubility that is 2–10 times larger than RAFM steels and CNAs. In addition, thermal desorption spectroscopy (TDS) measurements were performed to assess the deuterium retention and desorption of these materials following a static thermal deuterium charging at 723 Kfor 1 hour under the deuterium pressure of 1.0 x 10 5 Pa. It was found that ODS steels exhibit the highest deuterium retention and have broader desorption peaks. Microstructural features contributing to deuterium retention and impacting deuterium transport are discussed to rationalize the observed deuterium behavior in the studied RAFM steels.

36 MATERIALS SCIENCE↗

Probabilistic Risk Assessment of a Light Water Reactor Coupled with a High Temperature Electrolysis Hydrogen Production Plant

Two generic probabilistic risk assessments (PRA) for the addition of a heat extraction system (HES) addition to a light water reactor (LWR) are performed, one for a pressurized water reactor (PWR) and one for a boiling water reactor (BWR). The results investigate the applicability of the potential licensing approaches which do not require a full U.S. Nuclear Regulatory Commission (NRC) licensing review. The PRAs are generic, and some assumptions are made. Many conservative assumptions from a the preliminary PWR PRA report were eliminated using design data for both the HES and the high temperature electrolysis facility (HTEF). The results of the PRA indicate that the 10 CFR 50.59 licensing approach is justified due to the minimal increase in initiating event frequencies for all DBAs, none exceeding 5.6%. The PRA results for CDF and LERF support the use of RG 1.174 as further risk information that supports a change without a full LAR. Further insights provided through hazard analysis and sensitivity studies confirm with high confidence that the safety case for licensing an HES addition and a HTEF sited at 1.0 km from the NPP is strong and that the placement of a HTEF at 0.5 km is a viable case. Site specific information can alter these conclusions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Statistical and Machine Learning Approaches to Analyzing Pipeline Incidents in the United States (2010–2024)

This study applies machine learning methods to analyze natural gas pipeline incidents in the United States using the Pipeline and Hazardous Materials Safety Administration (PHMSA) Gas Distribution Incident Dataset (2010–2024). The dataset includes over 600 variables describing incident characteristics, infrastructure attributes, and contributing factors associated with unintentional gas releases. The objective is to assess whether these features can reliably predict the underlying cause of pipeline failures. Multinomial logistic regression and Random Forest models were developed to classify incident causes, including excavation damage, corrosion, equipment failure, and natural forces. Results show that excavation damage is both the most frequent and most predictable cause, with models achieving strong performance for this category. However, when excavation damage is excluded, model accuracy declines significantly, with some models performing near random levels. Across all approaches, severe class imbalance and limited variability in key predictors constrain predictive performance. Pipeline age and diameter emerge as the most influential variables, but they provide insufficient discriminatory power to distinguish among less frequent failure types. These findings indicate that non-excavation-related incidents are rare, heterogeneous, and weakly represented in the dataset, limiting the effectiveness of machine learning classification. Overall, this study highlights the structural limitations of the PHMSA dataset for predictive modeling and underscores the need for improved data balance and feature enrichment. The results reinforce excavation damage prevention as the most impactful strategy for reducing pipeline incidents.

03 NATURAL GAS↗

Unveiling the High‐Voltage Reactivity and Gas Evolution With Aluminum‐Based Chloride and Oxychloride Catholytes in Solid‐State Sodium Batteries

All-solid-state sodium batteries (ASSBs) employing halide solid electrolytes (SEs) offer a cost-effective and energy-dense alternative to conventional liquid electrolyte systems. However, their high voltage (>4 V vs. Na/Na + ) performance remains limited by interfacial instability between the cathode active material (CAM) and the SE. We present here the electrochemical and interfacial behaviors of crystalline NaAlCl 4 and amorphous sodium–aluminum–oxychloride (NACO) SEs when combined with NaNi 0.5 Mn 0.5 O 2 cathode. While oxygen incorporation in NACO enhances ionic conductivity by nearly three orders of magnitude relative to NaAlCl 4 , it does not improve high-voltage cycling stability. Cells employing NACO exhibit accelerated capacity fade, increased cell impedance growth, and intrinsic oxygen evolution above 4.5 V vs. Na 3 Sn, as revealed by operando electrochemical mass spectrometry. In contrast, the NaAlCl 4 -based cells show no detectable gas release, underscoring their superior high-voltage stability and safety. Time-of-flight secondary-ion mass spectrometry confirms the formation of Al─O and Ni/Mn─Cl species, respectively, in the SE and CAM, indicating redox-driven anion exchange that contributes to kinetic hindrance of high-voltage phase transitions. The findings establish that while oxygen incorporation enhances ionic transport, it can compromise interfacial stability, suggesting pure chloride SEs may offer a more robust and intrinsically safer pathway for developing high-energy ASSBs.

25 ENERGY STORAGE↗

Safety Testing of AGR-5/6/7 Compacts 2-2-2 and 2-2-4

Compacts 2-2-2 and 2-2-4 from the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program’s final irradiation campaign (AGR-5/6/7) were each separately subjected to a thermal soak at 1600°C for 300 h under flowing helium to simulated conditions experienced during a postulated high-temperature gas-cooled reactor (HTGR) depressurization conduction cooldown event. The safety testing of the fuel compacts’ performance under accident conditions was conducted in the Oak Ridge National Laboratory (ORNL) Core Conduction Cooldown Test Facility (CCCTF), which utilizes a stand-alone hot cell at the Irradiated Fuels Examination Laboratory (IFEL). The CCCTF heats fuel to temperatures up to 1900°C in a non-oxidizing environment while continuously monitoring the sweep gas for radioactive 85 Kr to detect release levels associated with hermetic failure of the tristructural-isotropic (TRISO) coating surrounding each fuel kernel. In addition, certain metallic radionuclides that escape the fuel compact are collected on deposition cups that are periodically exchanged with a new cup to obtain information on the overall retention behavior of the TRISO coating layers. Because cesium can diffuse through intact pyrocarbon layers, abnormal degradation of the silicon carbide (SiC) layer in the absence of holistic TRISO coating failure is indicated by release of 134 Cs at levels equivalent to an individual particle inventory in the absence of significant 85 Kr release (Hunn et al. 2014). Additional description of the CCCTF system is provided in Appendix A.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Impact of fission yield covariance matrices on decay heat uncertainty quantification with the DARWIN2 package

Although fission yields are strongly correlated, correlations between them are usually not taken into account when performing decay heat uncertainty calculations with the CEA DARWIN2 package due to the lack of reference covariance matrices associated to the JEFF-3.1.1 evaluation. However, covariance matrices for {sup 235}U and {sup 239}Pu thermal fission yields have been produced recently by the subgroup 37 of OECD/NEA Working Party on International Nuclear Data Evaluation Cooperation (WPEC). The study presented in this paper evaluates the effect of those covariances on the decay heat uncertainty calculation, both on fission burst experiments and on integral decay heat measurements that are part of the DARWIN2 experimental validation database. Although some differences are observed, partly due to the variety of models used to produce the matrices, the propagation of fission yield covariances always leads to a reduction of the decay heat uncertainty for cooling time above 10 seconds, indicating that not taking them into account is a conservative hypothesis from a safety point of view. Nevertheless, the strong impact of those covariances on the decay heat uncertainty also highlights the need of documented and consistent fission yield uncertainties and correlation data. On top of that, all the covariance matrices used for this study represent the correlation between the physical model parameters, but none of them includes the experimental correlations. An evaluation of the experimental correlations would also be of strong interest for decay heat uncertainty calculations. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparative Analysis of Hotspot Stress Endurance in Pristine and Thermal Cycled Prestressed Glass–Glass Photovoltaic Modules

Hotspots pose a significant long-term reliability challenge in photovoltaic (PV) modules that can have a detrimental impact on the efficiency, safety, and financial viability of a PV system. This paper aims to evaluate the endurance of hotspot stress in pristine and prestressed glass–glass (GG) modules. The accelerated prestressing was conducted for 600 thermal cycles (TC600) to represent decades of field exposure. GG modules are quickly becoming an alternative to the traditional glass–backsheet (GB) modules that have been the industry standard. Unlike other conventional studies that subject only pristine modules to hotspot stress, this paper evaluates the performance of an accelerated/simulated field-aged GG module (using TC600) and a pristine GG module. Pre- and post-characterizations were performed before and after each test to determine changes in electrical performance and observe any defects in GG modules. During the hotspot test, an approximately 200 °C maximum cell temperature was observed with a cell shading of 25% (the worst-case shading ratio). After the hotspot test, electroluminescence imaging indicated that most cells in the prestressed GG module exhibited severe damage whereas no significant defects were evident in the pristine GG module where the prestressed GG module degraded 8.2% and the pristine GG module degraded 1.5% in maximum power. These findings are critical for the industry, considering that GG bifacial modules will dominate the market.

14 SOLAR ENERGY↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report (DOE 2023) provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

42 ENGINEERING↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LAMP Technical Readiness Evaluation Report

An internal preliminary evaluation of Critical Technology Elements (CTEs) for the LANSCE Modernization Project (LAMP) was completed in 2023. This included determining corresponding Technical Readiness Levels (TRLs) for all subsystems using the criteria of DOE G 413.3-4A, Technical Readiness Assessment Guide. This revised report includes a summary of the recent design modifications required to meet the project Key Performance Requirements (KPPs), some of which may reduce technical risk to the project. These recent design modifications include: • Further optimization of the low-energy and medium-energy beam transport regions (LEBT and MEBT, respectively), including relocation of various functional elements (ie choppers, kickers, and bunchers). • An additional H - ion source to separate ion-source function based on beam delivery requirements. • A high-repetition-rate pulsed kicker magnet to select/merge the two H ion beams into a common low-energy beam transport. • Modification and further optimization to a more conventional RFQ design. Performance of the RFQ has been optimized to deliver the required three types of beams while meeting the project KPPs. • The addition of a second chopper in the medium-energy beam transport (MEBT) line to reduce the required pulser voltages. The scope of the evaluation was limited to the project Work Breakdown Structure (WBS) elements as defined for the RFQ Injector and Drift Tube Linac (DTL) systems only. Integration of Instrumentation and Controls (I&C) and Safety Systems was not considered, although specific technologies as related to the RFQ and DTL systems were included. Other elements of the project such as Shielding, System Design, Technical Management, and additional facility integration needed to enable off-line testing and pre-installation commissioning were also not evaluated. Each technical subsystem element was evaluated for technical readiness, however, not all were found to meet the criteria for a CTE. Three subsystem elements were determined to meet the CTE criteria. Their associated TRLs are summarized in the table below. These subsystem elements of the project have the lowest technical readiness due to either being new, novel or modified, requiring additional R&D before being capable of meeting the project Key Performance Parameters (KPPs) and subsystem requirements, or present technology exists but has not yet been demonstrated in a relevant environment. All other subsystems were determined to have a TRL of 8, indicating that actual operating systems exist having similar performance requirements as needed for LAMP. Details of the technical readiness evaluation for each subsystem is given in the following sections of this report.

43 PARTICLE ACCELERATORS↗

LAMP Technical Readiness Evaluation Report (Rev. 1)

An internal preliminary evaluation of Critical Technology Elements (CTEs) for the LANSCE Modernization Project (LAMP) was completed. Corresponding Technical Readiness Levels (TRLs) were also determined for all subsystems using the criteria of DOE G 413.3-4A, Technical Readiness Assessment Guide. The scope of the evaluation was limited to the project Work Breakdown Structure (WBS) elements as defined for the RFQ Injector and Drift Tube Linac (DTL) systems only. Integration of Instrumentation and Controls (I&C) and Safety Systems was not considered, although specific technologies as related to the RFQ and DTL systems were included. Other elements of the project such as Shielding, System Design, Technical Management, and additional facility integration needed to enable off-line testing and pre-installation commissioning were also not evaluated. Each technical subsystem element was evaluated for technical readiness, however, not all were found to meet the criteria for a CTE. Only two subsystem elements were determined to meet the CTE criteria. Their associated TRLs are summarized in the table below. These subsystem elements of the project have the lowest technical readiness due to either being new, novel or modified, requiring additional R&D before being capable of meeting the project Key Performance Parameters (KPPs) and subsystem requirements, or present technology exists but has not yet been demonstrated in a relevant environment. All other subsystems were determined to have a TRL of 8, indicating that actual operating systems exist having similar performance requirements as needed for LAMP. Details of the technical readiness evaluation for each subsystem is given in the following sections of this report.

43 PARTICLE ACCELERATORS↗

Capability Building Progression of an Insider Threat Mitigation Program at an International Research Reactor

The nuclear industry recognizes the difficulties involved in developing effective managerial and leadership skills in a highly technical and proficient workforce such as that found in nuclear facilities. Implementing an insider threat mitigation program (ITMP) within the nuclear industry is a complex and ongoing process that demands a comprehensive understanding of human behavior, an organization’s security culture, and rigorous regulatory requirements yet also accounts for facility characteristics, physical security, material flow, and activities involving nuclear material. Given the high-consequence nature of research reactor operations, even minor lapses can lead to safety, security, and reputational risks. An effective ITMP requires a defense-in-depth approach that incorporates behavioral analysis, robust vetting procedures, continuous monitoring, and cross-disciplinary coordination. It must also promote a culture of vigilance and accountability at all levels up to and including executive leadership but be flexible enough to adapt to evolving global threats and technological advances. Insider threat mitigation is not a one-time effort but rather a sustained commitment to excellence in safety and security. Establishing a culture in which personnel proactively report incidents and issues that could affect nuclear safety and security is vital to maintaining a safe and secure operational environment. This document was developed to guide senior management and research reactor organizations in creating comprehensive programs to effectively manage and mitigate insider threat behaviors and actions. It focuses on the key pillars of an effective ITMP, including the national legal framework, security culture, preventive and protective measures, cyber security, and performance evaluation. By using a systematic approach during implementation, facilities can foster environments conducive to insider threat detection and support long-term program sustainability. The document also provides strategies for improving communication across all levels of an organization, helping to eliminate barriers that hinder the development of robust ITMPs and enhance overall security culture. In today’s organizations, the concept of leveraging safety and security culture lessons to facilitate knowledge transfer is rapidly evolving to expedite insider threat management and security culture improvements. This document outlines the rationale for evaluating an ITMP based on national customs, culture, and stakeholders. The elements are all germane to reliability and trustworthiness and relate to security concerns that states may encounter. The document focuses not only on individual perceptions regarding security issues and capability building but also on team building and how to resolve concerns. The implementers of a facility’s ITMP may zero in on indicators of insider threats within their enterprise. This material will benefit organizations when it is applied using a systematic and structured approach as demonstrated throughout the document.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗