Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Explainability and human intervention in autonomous scanning probe microscopy

The broad adoption of machine learning (ML)-based autonomous experiments (AEs) in material characterization and synthesis requires strategies development for understanding and intervention in the experimental workflow. Here, we introduce and realize a post-experimental analysis strategy for deep kernel learning-based autonomous scanning probe microscopy. This approach yields real-time and post-experimental indicators for the progression of an active learning process interacting with an experimental system. We further illustrate how this approach can be applied to human-in-the-loop AEs, where human operators make high-level decisions at high latencies setting the policies for AEs, and the ML algorithm performs low-level, fast decisions. The proposed approach is universal and can be extended to other techniques and applications such as combinatorial library analysis.

47 OTHER INSTRUMENTATION↗

Cooling rate dependence of charge density wave phases in 1 T -TaS 2 studied by scanning tunneling microscopy and x-ray diffraction

The role of dynamics in the charge density wave (CDW) phases of 1T-TaS 2 , especially in accessing metastable phases, is still under scrutiny. We investigated cooling rate dependence on low-temperature CDW phases in this material by scanning tunneling microscopy and x-ray diffraction. In the majority of cases, we found the typical low temperature commensurate CDW and identified no other differences between samples that were fast cooled vs slow cooled from room temperature. In rare cases (1/18 STM experiments and 1/30 XRD experiments), we found a multi-domain structure in the low temperature CDW. The domain structure and metallic behavior revealed by STM and STS measurements of this phase are in excellent agreement with the previously reported metallic mosaic CDW phase.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of defect growth structure in ion plated films by scanning electron microscopy

Copper and gold films (0.2 to 2 microns) were ion plated onto polished 304-stainless-steel surfaces. These coatings were examined by scanning electron microscopy for coating growth defects. Three types of defects were distinguished: nodular growth, abnormal or runaway growth, and spits. The cause and origin for each type of defect was traced. Nodular growth is primarily due to inherent substrate microdefects, abnormal or runaway growth is due to external surface inclusions, and spits are due to nonuniform evaporation. All these defects have adverse effects on the coatings. They induce stresses and produce porosity in the coatings and thus weaken their mechanical properties. Friction and wear characteristics are affected by coating defects, since the large nodules are pulled out and additional wear debris is generated.

Spalvins, T.↗

Nanoscale properties of lead halide perovskites by scanning tunneling microscopy

Since the introduction of lead halide perovskites, tremendous progress has been made regarding their stability, reproducibility and durability. However, one of the issues that remains is related to the interfacial atomic structure arrangement and structure-property relationship under optical and electrical stimuli. In this critical review, we highlight the recent progress using scanning tunneling microscopy (STM) to understand the nanoscale properties and dynamic processes occurring in these halide perovskite materials. STM is known to be a very challenging technique, which is reflected by the low number of relevant publications in the last years. These initial reports mirror the unique potential of STM to give Ångstrom-scale insight into the (opto)-electronic properties, morphology and underlying electronic structure and provide a path toward harnessing the full potential of these materials. However, care must be taken to understand the effects of the perturbations caused by STM and tailor the measurement conditions accordingly.

36 MATERIALS SCIENCE↗

Process dependent morphology of the Si/SiO2 interface measured with scanning tunneling microscopy

A new experimental technique to determine Si/SiO2 interface morphology is described. Thermal oxides of silicon are chemically removed, and the resulting surface topography is measured with scanning tunneling microscopy. Interfaces prepared by oxidation of Si (100) and (111) surfaces, followed by postoxidation anneal (POA) at different temperatures, have been characterized. Correlations between interface structure, chemistry, and electrical characteristics are described.

Hecht, Michael H.↗

"Un-annealed and Annealed Pd Ultra-Thin Film on SiC Characterized by Scanning Probe Microscopy and X-ray Photoelectron Spectroscopy"

Pd/SiC has been used as a hydrogen and a hydrocarbon gas sensor operated at high temperature. UHV (Ultra High Vacuum)-Scanning Tunneling Microscopy (STM), Atomic Force Microscopy (AFM) and X-ray Photoelectron Spectroscopy (XPS) techniques were applied to study the relationship between the morphology and chemical compositions for Pd ultra-thin films on SiC (less than 30 angstroms) at different annealing temperatures. Pd ultra-thin film on 6H-SiC was prepared by the RF sputtering method. The morphology from UHV-STM and AFM shows that the Pd thin film was well deposited on SiC substrate, and the Pd was partially aggregated to round shaped participates at an annealing temperature of 300 C. At 400 C, the amount of surface participates decreases, and some strap shape participates appear. From XPS, Pd2Si was formed on the surface after annealing at 300 C, and all Pd reacted with SiC to form Pd2Si after annealing at 400 C. The intensity of the XPS Pd peak decreases enormously at 400 C. The Pd film diffused into SiC, and the Schottky barrier height has almost no changes. The work shows the Pd sicilides/SiC have the same electronic properties with Pd/SiC, and explains why the Pd/SiC sensor still responds to hydrogen at high operating temperatures.

Lu, W. J.↗

Unraveling the impact of initial choices and in-loop interventions on learning dynamics in autonomous scanning probe microscopy

The current focus in Autonomous Experimentation (AE) is on developing robust workflows to conduct the AE effectively. This entails the need for well-defined approaches to guide the AE process, including strategies for hyperparameter tuning and high-level human interventions within the workflow loop. This paper presents a comprehensive analysis of the influence of initial experimental conditions and in-loop interventions on the learning dynamics of Deep Kernel Learning (DKL) within the realm of AE in scanning probe microscopy. We explore the concept of the “seed effect,” where the initial experiment setup has a substantial impact on the subsequent learning trajectory. Additionally, we introduce an approach of the seed point interventions in AE allowing the operator to influence the exploration process. Using a dataset from Piezoresponse Force Microscopy on PbTiO 3 thin films, we illustrate the impact of the “seed effect” and in-loop seed interventions on the effectiveness of DKL in predicting material properties. The study highlights the importance of initial choices and adaptive interventions in optimizing learning rates and enhancing the efficiency of automated material characterization. This work offers valuable insights into designing more robust and effective AE workflows in microscopy with potential applications across various characterization techniques.

47 OTHER INSTRUMENTATION↗

A variable X-ray chopper system for phase-sensitive detection in synchrotron X-ray scanning tunneling microscopy

An ultra-high-vacuum compatible X-ray chopper system has been designed, constructed and integrated into the XTIP beamline at the Advanced Photon Source at Argonne National Laboratory. The XTIP beamline can operate at soft X-ray energies from 400 eV to 1900 eV while providing a focused beam down to about 10 µm × 10 µm into the synchrotron X-ray scanning tunneling microscopy (SX-STM) endstation instrument. The X-ray chopper is a critical component for separating topographic information from chemical information in SX-STM through phase-sensitive current detection. Depending on the experimental needs, the modulation frequency can be controlled from 100 Hz to 10 kHz. In addition, the chopper system is fully bakeable and can achieve a base pressure of 10 -10 mbar. Facilities for active water cooling have been designed, but passive cooling through copper braids has been shown to be sufficient at standard chopping frequencies. Using an Fe/Al 2 O 3 /CoAl(111) sample, the separation of the SX-STM current into a chemical component and a stable feedback signal is demonstrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Self-Assembly of Metallo-Supramolecules with Dissymmetrical Ligands and Characterization by Scanning Tunneling Microscopy

Asymmetrical and dissymmetrical structures are widespread and play a critical role in nature and life systems. In the field of metallo-supramolecular assemblies, it is still in its infancy for constructing artificial architectures using dissymmetrical building blocks. Herein, we report the self-assembly of supramolecular systems based on two dissymmetrical double-layered ligands. With the aid of ultra-high-vacuum, low-temperature scanning tunneling microscopy (UHV-LT-STM), we were able to investigate four isomeric structures corresponding to four types of binding modes of ligand LA with two major conformations complexes A. The distribution of isomers measured by STM and total binding energy of each isomer obtained by density functional theory (DFT) calculations suggested that the most abundant isomer could be the most stable one with highest total binding energy. Lastly, through shortening the linker between inner and outer layers and the length of arms, the arrangement of dissymmetrical ligand LB could be controlled within one binding mode corresponding to the single conformation for complexes B.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging graphite in air by scanning tunneling microscopy - Role of the tip

Atomically resolved images of highly oriented pyrolytic graphite (HOPG) in air at point contact have been obtained. Direct contact between tip and sample or contact through a contamination layer provides a conduction mechanism in addition to the exponential tunneling mechanism responsible for scanning tunneling microscopy (STM) imaging. Current-voltage (I-V) spectra were obtained while scanning in the current imaging mode with the feedback circuit interrupted in order to study the graphite imaging mechanism. Multiple tunneling tips are probably responsible for images without the expected hexagonal or trigonal symmetry. The observations indicate that the use of HOPG for testing and calibration of STM instrumentation may be misleading.

Colton, R. J.↗

Chemical Silver Coating of Fiber Tips in Near-Field Scanning Optical Microscopy

We report what is believed to be the first experimental demonstration of silver coating by a wet chemical process on tapered fiber tips used in near-field scanning optical microscopy. The process is at room temperature and pressure and takes only a few minutes to complete. Many tips can be simultaneously coated.

Vikram, Chandra S.↗

Correlative X-ray micro-nanotomography with scanning electron microscopy at the Advanced Light Source

Geological samples are inherently multi-scale. Understanding their bulk physical and chemical properties requires characterization down to the nano-scale. A powerful technique to study the three-dimensional microstructure is X-ray tomography, but it lacks information about the chemistry of samples. To develop a methodology for measuring the multi-scale 3D microstructure of geological samples, correlative X-ray micro- and nanotomography were performed on two rocks followed by scanning electron microscopy with energy-dispersive spectroscopy (SEM-EDS) analysis. The study was performed in five steps: (i) micro X-ray tomography was performed on rock sample cores, (ii) samples for nanotomography were prepared using laser milling, (iii) nanotomography was performed on the milled sub-samples, (iv) samples were mounted and polished for SEM analysis and (v) SEM imaging and compositional mapping was performed on micro and nanotomography samples for complimentary information. Correlative study performed on samples of serpentine and basalt revealed multiscale 3D structures involving both solid mineral phases and pore networks. Significant differences in the volume fraction of pores and mineral phases were also observed dependent on the imaging spatial resolution employed. This highlights the necessity for the application of such a multiscale approach for the characterization of complex aggregates such as rocks. Information acquired from the chemical mapping of different phases was also helpful in segmentation of phases that did not exhibit significant contrast in X-ray imaging. Adoption of the protocol used in this study can be broadly applied to 3D imaging studies being performed at the Advanced Light Source and other user facilities.

58 GEOSCIENCES↗

Two-Photon Fluorescence Microscopy Developed for Microgravity Fluid Physics

Recent research efforts within the Microgravity Fluid Physics Branch of the NASA Glenn Research Center have necessitated the development of a microscope capable of high-resolution, three-dimensional imaging of intracellular structure and tissue morphology. Standard optical microscopy works well for thin samples, but it does not allow the imaging of thick samples because of severe degradation caused by out-of-focus object structure. Confocal microscopy, which is a laser-based scanning microscopy, provides improved three-dimensional imaging and true optical sectioning by excluding the out-of-focus light. However, in confocal microscopy, out-of-focus object structure is still illuminated by the incoming beam, which can lead to substantial photo-bleaching. In addition, confocal microscopy is plagued by limited penetration depth, signal loss due to the presence of a confocal pinhole, and the possibility of live-cell damage. Two-photon microscopy is a novel form of laser-based scanning microscopy that allows three-dimensional imaging without many of the problems inherent in confocal microscopy. Unlike one-photon microscopy, it utilizes the nonlinear absorption of two near-infrared photons. However, the efficiency of two-photon absorption is much lower than that of one-photon absorption because of the nonlinear (i.e., quadratic) electric field dependence, so an ultrafast pulsed laser source must typically be employed. On the other hand, this stringent energy density requirement effectively localizes fluorophore excitation to the focal volume. Consequently, two-photon microscopy provides optical sectioning and confocal performance without the need for a signal-limiting pinhole. In addition, there is a reduction in photo-damage because of the longer excitation wavelength, a reduction in background fluorescence, and a 4 increase in penetration depth over confocal methods because of the reduction in Rayleigh scattering.

Fischer, David G.↗

Scanning-electron-microscopy observations and mechanical characteristics of ion-beam-sputtered surgical implant alloys

An electron bombardment ion thruster was used as an ion source to sputter the surfaces of orthopedic prosthetic metals. Scanning electron microscopy photomicrographs were made of each ion beam textured surface. The effect of ion texturing an implant surface on its bond to bone cement was investigated. A Co-Cr-W alloy and surgical stainless steel were used as representative hard tissue implant materials to determine effects of ion texturing on bulk mechanical properties. Work was done to determine the effect of substrate temperature on the development of an ion textured surface microstructure. Results indicate that the ultimate strength of the bulk materials is unchanged by ion texturing and that the microstructure will develop more rapidly if the substrate is heated prior to ion texturing.

Weigand, A. J.↗

Nanoscale Surface Structure of Nanometer-Thick Ferroelectric BaTiO 3 Films Revealed by Synchrotron X-ray Scanning Tunneling Microscopy: Implications for Catalytic Adsorption Reactions

Ferroelectric nanomaterials are of interest in catalysis, non-volatile memory, and neuromorphic computing among other applications because of their switchable structure that can alter electronic and interface properties of a single material. The investigation of the role of polarization on the surface structure and chemistry of ferroelectric nanomaterials is a longstanding challenge, as it ideally requires a combination of both nanoscale imaging and chemical spectroscopy. In this work we study a model ferroelectric BaTiO 3 thin film by synchrotron X-ray scanning tunneling microscopy (SX-STM), a unique method which integrates nanoscale surface imaging and chemically sensitive spectroscopy. We find that polarization switching from downward to upward in (001)single crystalline BaTiO 3 thin films increases the intensity of X-ray absorption across Ba M, Ti L and O K edges. Chemical mapping of nanometer sized domains further demonstrates the modulation of surface structures upon polarization switching, as well as confirming the trends observed in single point experiments across the surface. Here, we complement these measurements with ab-initio computational absorption spectroscopy to elucidate the effect of polarization switching on the core-hole excitations using the Bethe-Salpeter equation approach. Our experimental and theoretical results thus confirm a stronger binding strength for the upward polarized surface with molecular O 2 as a model reactant, offering mechanistic evidence that supports previous reports. This work advances the understanding of the surface chemistry and electronic structure of ferroelectrics, which can ultimately aid strategies to design interfaces with tailored properties.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Quantifying magnetic field driven lattice distortions in kagome metals at the femto-scale using scanning tunneling microscopy

A wide array of unusual phenomena has recently been uncovered in kagome solids. The charge density wave (CDW) state in the kagome superconductor AV 3 Sb 5 , in particular, intrigued the community; the CDW phase appears to break the time-reversal symmetry despite the absence of spin magnetism, which has been tied to exotic orbital loop currents possibly intertwined with magnetic field tunable crystal distortions. To test this connection, precise determination of the lattice response to an applied magnetic field is crucial but can be challenging at the atomic scale. We establish a scanning tunneling microscopy (STM) based method to study the evolution of the AV 3 Sb 5 atomic structure as a function of magnetic field. The method substantially reduces the errors of typical STM measurements, which are at the order of 1% when measuring an in-plane lattice constant change. Here, we find that the out-of-plane lattice constant of AV 3 Sb 5 remains unchanged (within 10 —6 ) by the application of both in-plane and out-of-plane magnetic fields. We also reveal that the in-plane lattice response to magnetic field is at most at the order of 0.05%. Our experiments provide further constraints on time-reversal symmetry breaking in kagome metals and establish a tool for higher-resolution extraction of the field-lattice coupling at the nanoscale applicable to other quantum materials.