Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensible heat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A High Temperature Gas Reactor Integrated Energy System Using Energy Storage as a Buffer for Hydrogen Production

Analysis of an integrated energy system producing hydrogen in a high temperature steam electrolysis system via steam provided by a sensible heat thermal energy storage system charged by a high temperature gas reactor. Preliminary results over a continuous discharge cycle and single charging cycle shows minimal reactor impact despite 25% electrical power load change. Hydrogen production is held constant with steam provided by the thermal energy storage system.

08 HYDROGEN↗

Risks and Benefits of Pressurized Water Reactor Coupling to Energy Storage and Water Desalination

This research explored potential options to improve nuclear pressurized water reactors’ (PWRs) operational flexibility through integration with thermal energy storage (TES) and water desalination technologies. Benefits and challenges of TES technologies were reviewed, which includes sensible heat storage systems, latent heat storage systems, and thermochemical storage systems. Water desalination technologies were reviewed and compared, which includes multi-stage flash, reverse osmosis, and multi-effect distillation. The multi-effect distillation technology was selected to be coupled with a generic PWR. Risk of this cogeneration was quantified using the probabilistic risk assessment (PRA) methodology. Results suggest that nuclear-desalination cogeneration can be done safely because the additional risk to the PWR is trivial, and even in certain cases the PWR risk is decreased. This cogeneration operation is expected to improve efficiency of thermal utilization and the nuclear plant’s revenues. In summary, this study supports the potential of nuclear-desalination cogeneration systems to address water scarcity while optimizing nuclear energy use and managing safety.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Intercomparison of sensible and latent heat flux measurements from combined eddy covariance, energy balance, and Bowen ratio methods above a grassland prairie

We present a comparison of four different methods of measuring sensible (H) and latent (LE) heat fluxes for a year over a mixed grass prairie ecosystem in the Nebraska SandHills [eddy covariance (EC), energy balance/Bowen ratio (EBBR), residual energy (RES), modified Bowen ratio (MBR) methods]. Additionally, we developed a set of quality control criteria for each method and present a simplification to the traditional EBBR setup. Using EC as reference, all methods yielded similar estimates of yearly H (regression slopes (m) ~ 2% from unity; H EC > H EBBR , H RES , and H MBR ). For yearly LE, EBBR and RES yielded similar estimates with EC (m ~ 2% from unity; LE EC < LE EBBR and LE RES ), while a larger bias was found from MBR (m ~ 8% from unity; LE EC > LE MBR ). At shorter time scales (~ hourly), moderate scatter was found about linear regression fits for H between EBBR and EC (R 2 = 0.81), with smaller scatter between RES and MBR, and EC (R 2 = 0.91). For LE, smaller scatter was also measured between EC, and EBBR and RES (R 2 = 0.89 and 0.87, respectively), with the larger scatter between EC and MBR (R 2 = 0.65). This suggests methods other than EC may be well suited to longer-term applications (≥ yearly), but have larger uncertainty on individual measurements.

54 ENVIRONMENTAL SCIENCES↗

An advanced membrane-based HMX model and its application in utilizing sensible and latent heat removed in space cooling

This paper presents a comprehensive simulation model for advanced membrane-based heat and mass exchanger (HMX) components which account for three separate fluid streams with complex flow patterns. The model was implemented with various liquid desiccants and their properties (including LiCl, CaCl and ionic liquid (IL)). Preliminary model validation is presented using data from a laboratory prototype absorber. The paper also presents implementation of the model into a sorption system modeling platform and analyzes potential benefit analysis of the HMX component in utilizing the sensible and latent heat removed in space cooling to heat water. The developed model and codes are expected to enable detailed optimization studies and identify novel configurations for the three-fluid HMX maximum performance and cost effectiveness.

Gao, Zhiming↗

Numerical Investigation of High Delta T Sensible Storage Integrated CO2 Heat Pump: Preprint

To assist building heating electrification, this paper numerically investigates a load flexible heat pump system for commercial buildings. The system consists of a CO2 vapor compression cycle, a sensible thermal storage tank, and an air handling unit. The thermal storage medium is inexpensive, non-toxic and stable anti-freeze solution (30% potassium acetate). The air handing unit has an indoor coil and a ventilation coil. The system can be used to manage building electric load. During peak hours, the heat pump is off and the hot solution water is discharged from the tank to heat up the indoor air and ventilation air. During the hour of charge, the heat pump delivers hot solution water to the tank and to the air. The tank can also stand by while the heat pump provides space heating directly. We selected a medium sized office building located in Minnesota as the representative building and used EnergyPlus to obtain its 24 hour load data. We designed three storage tank volumes assuming 50 degrees C, 65 degrees C and 80 degrees C tank temperatures to independently provide the building load for 4 hours in the morning. The higher the tank temperature, the smaller the required volume, and thus higher energy density. The effective energy density is 78 with an 80 degrees C tank, and 40 kWhth/m3 with 50 degrees C. We simulated the tank integrated heat pump performance subjected to the 24-hour building load profile and ambient data. The baseline is the same system without storage tank. There was a trade-off between the storage energy density and the charging COP. The charge hour COP was 2.77 to charge the tank to 80 degrees C, and 3.01 to 50 degrees C. The proposed system could shift building load from the peak hours (8:00 - 12:00) to off-business hour (23:00 - 7:00+1). It eliminated 100% compressor electricity use during the peak hours, and avoided a peak electric power of 34 kW. The 65 degrees C tank saved 9.5 kWhe (4%) considering all day operation, which was the best balance between energy density and the system operation efficiency among the three options.

CO2 heat pump↗

Daytime convective development over land: the role of surface forcing

Water availability at the Earth surface determines the portioning of the surface heat flux into its sensible and latent components, that is, the surface heat flux Bowen ratio. The two components affect differently the surface buoyancy flux and thus the development and growth of the convective boundary layer. As a result, the Bowen ratio has a strong impact on the daytime dry and moist convection development over land. Here, we use two canonical modeling test cases, one for the shallow convection and one for the shallow-to-deep convection transition, to document the impact of the surface Bowen ratio on daytime convection development. A simple approach is used where results from simulations featuring the original setup are contrasted with simulations where surface sensible heat flux takes on values of the latent heat flux and vice versa. Such a change illustrates the key impact of the surface water availability without changing the total surface heat flux. Because of the larger surface buoyancy flux, simulations with the reversed surface heat fluxes feature faster deepening of the convective boundary layer and wider clouds once moist convection develops. Mean cloud base width of cumulus clouds increases with the boundary layer depth. For shallow-to-deep convection transition, comparison of simulations with the observed large-scale flow that feature substantial lower-tropospheric shear with simulations with no mean horizontal flow suggests that the organization of convective circulations within the boundary layer strongly affects initial size and organization of shallow convection, as well as the subsequent width increase once convection deepens and eventually transitions to deep precipitating convection. A simple explanation is provided of why deeper well-mixed convective subcloud layer results in wider clouds. The key is the larger width of boundary layer coherent updraft structures when the mixed layer is deeper.

54 ENVIRONMENTAL SCIENCES↗

CROCUS Urban Fluxes of CO₂, H₂O, and Turbulence at University of Illinois Chicago

As of May 12, 2026 this dataset is currently being versioned to include data up to April 2026. Once the versioning process is complete, new data files will be available for access. The dataset metadata will also be updated to reflect the data availability of the new data being versioned. This dataset was collected at the UIC Plant Research Laboratory in Chicago, Illinois, as part of the Community Research on Climate and Urban Science (CROCUS) Urban Integrated Field Laboratory (UIFL) project, led by Argonne National Laboratory. The site provides continuous atmospheric flux measurements, focusing on CO₂, H₂O, and heat and momentum transport in an urban setting. The data is processed at 30 minutes interval using the Eddy Covariance method and includes quality control and diagnostic data generated by EddyPro software. The data is stored in the netCDF files following CF conventions. The UIC Plant Research Laboratory is located near major highways and urban infrastructure, including buildings and parking areas. The surrounding landscape consists of a mix of turf, plants, trees, and impervious surfaces such as concrete and asphalt, making it ideal for studying urban at for studies on urban sustainability, air quality, and the effects of urbanization on atmospheric processes on urban climate dynamics, air quality, and surface-atmosphere exchanges within the city of Chicago. This dataset is funded by the U.S. Department of Energy’s Office of Science, Biological and Environmental Research (BER) program.

54 ENVIRONMENTAL SCIENCES↗

Influence of Vegetation Canopy Architecture on Dynamics of Spatiotemporal Light Distribution and its Effect on Land-Biosphere-Atmosphere Fluxes of Energy, Carbon, and Water

The dynamic spatiotemporal distribution of light and micro climatic variables (wind speed, atmospheric CO 2 concentration, humidity, pressure, and air temperature) within the plant canopy as determined by the canopy architecture play a critical role in land-biosphere-atmosphere (LBA) photosynthetic carbon uptake, transpiratory water loss and energy partitioning. Vegetation models that include effects of sun and shade flecks, leaf temperature and energy balance partitioning between sensible and latent heat fluxes, and reduced turbulent mixing in dense vegetation canopies can accurately predict canopy performance, particularly its shaded leaves, which can constitute 80% of leaf area and contribute up to 50% of carbon update and 65% of water loss. However, current vegetation models with their bulk characterization of shaded leaves poorly represent the complex three dimensional (3D) canopy architecture are insufficient to capture the spatiotemporal dynamics of shaded leaves. Here, we propose to employ an x-ray computed tomography (XCT) imaging technique in combination with an automated, high throughput, image processing pipeline (3DArch, to be developed) to obtain an explicit 3D triangulated surface mesh of a plant canopy (Fig 1). 3DArch would provide a much needed technological jump in 3D LBA modeling where computer generated artificial 3D models suffer from lack of high resolution detailed canopy architecture parameters. The 3D canopy surface mesh output from 3DArch is coupled with an explicit 3D forward ray tracing model (fastTracer) to obtain a high resolution representation of the dynamic spatiotemporal light environment within the canopy over the course of a day (Fig 1). The results from the light attenuation model are then coupled with a process based multi-scale bio-physical canopy and leaf model of photosynthesis (PlantGro) to get fluxes of carbon, water and energy at the leaf and canopy scale, in addition to estimating whole plant carbon uptake, and water loss. Our proposed model framework would be the first of its kind to provide a breakthrough capability in the field of process-based plant modeling that bridges the key technological gap in shaded leaf modeling through explicit representation of 3D canopy architecture. Computer generated artificial 3D model canopy simulations on grasses show that the canopy light distribution does not follow an exponential behavior as assumed in most 1D vegetation models, but rather exhibits a heterogeneous behavior, with a small but significant portion of interior canopy leaves experiencing peak light levels due to sun flecks while the rest of the canopy receives substantially lower light levels. These results indicate a bias in traditional models that overestimates shaded leaf contribution towards whole canopy photosynthesis by up to 15% and underestimate transpiration by up to 12% with an associated increase in sensible heat fluxes since photosynthesis, transpiration and energy partitioning are tightly coupled processes. However, these test results need to be validated using the 3D architecture obtained from a real plant imaged in 3D using 3DArch, rather than an artificial model plant. Our proposed model framework would allow us to identify inefficiencies in canopy light distribution and prescribe optimal canopy architectures (leaf optical properties, leaf area, leaf angles, row spacing, planting density, etc.) to traditional and genetic engineering based crop breeders, for maximizing target functions such as light use efficiency, water use efficiency, drought tolerance, crop yield, crop resilience etc., with important applications in biofuel crops such as sorghum, and switchgrass. Our model can also be applied for designing optimal canopy architecture that increase surface albedo as a mitigation strategy for global warming and projections of crop yield for future food and water security under climate change.

59 BASIC BIOLOGICAL SCIENCES↗

Optimal design of multi-stage vacuum membrane distillation and integration with supercritical water desalination for improved zero liquid discharge desalination

Herein this paper proposes a novel concept for the optimal design of multi-stage vacuum membrane distillation (VMD). Generally, a multi-stage VMD is designed with an equal temperature difference between each stage. However, such a design is energy inefficient and increases VMD area. An analytical methodology for calculating the optimal stage temperature is proposed. By selecting the optimal stage temperature, the energy efficiency and required membrane area can be potentially improved by 16% and 30%, respectively. The proposed concept applies to all heat sources, including latent, sensible, and waste heat. To illustrate the method, multi-stage VMD is integrated with the waste heat from a supercritical water desalination (SCWD) system to achieve zero liquid discharge. SCWD is an energy-intensive process, requires high-quality thermal heat (>450 °C), and exhibits high waste heat rejection. The integrated VMD-SCWD approach is approximately 50% more energy-efficient and 35% more cost-efficient than the standalone SCWD system. Compared to the commercially used brine concentrator and crystallizer, the multi-stage VMD-SCWD system is more energy efficient for feed concentrations >5%. VMD-SCWD system is 30% cheaper, due to less expensive membrane distillation modules compared to a brine concentrator. The proposed design concept can replace the brine concentrator and crystallizer as an improved alternative for a zero-liquid discharge desalination system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computational fluid dynamic analysis of a novel particle-to-air fluidized-bed heat exchanger for particle-based thermal energy storage applications

Long-duration energy storage technologies are being targeted to enable cost-effective, decarbonized energy systems. Particle-based thermal energy storage systems are one promising technology by storing excess electricity or heat as sensible thermal energy in inexpensive, solid, inert particles. These systems are only possible if an effective and economical particle-to-working fluid heat exchanger exists. This study predicts the performance of a proposed, direct-contact, particle-to-air, pressurized fluidized-bed heat exchanger using computational fluid dynamics. The common Eulerian-Eulerian framework for modeling fluidized beds is first benchmarked to experimental results at a previously untested operating condition and application. Then, the benchmarked model evaluates the performance of a proposed design for a commercial-scale version of the novel particle-to-air heat exchanger. The results show pressure drop and gas-phase approach temperatures are advantageous compared to other proposed designs for particle-to-air heat exchangers in the literature; approach temperatures were less than 5 °C and gas-phase pressure drop across the fluidized bed was 32 kPa. The model also highlights the importance of gas distributor design and representation in the Eulerian-Eulerian framework to control fluidization behavior. In conclusion, the model built and benchmarked in this study can be leveraged to advance the design and analysis of these heat exchangers critical to the deployment of a promising long-duration energy storage technology.

25 ENERGY STORAGE↗

Meteorological Variables and Energy Fluxes at the Pumphouse Site, Crested Butte, CO 2017-2019

This data contains output from the pumphouse eddy covariance tower that includes shortwave radiation, longwave radiation, net radiation, air temperature, relative humidity, as well as sensible, latent, and ground heat fluxes. Also included is calculated evapotranspiration from the latent heat flux and the latent heat of vaporization. All data are on a daily timestep and displayed in Mountain Time. The data has been processed, and Quality Assurance / Quality Control (QA/QC) was done, but any daily gaps in the data have not been filled in. This research was funded by the Department of Energy and performed as part of the Watershed Function Scientific Focus Area. This research aimed to constrain evapotranspiration in a high-elevation catchment.The dataset includes one comma-separated values (CSV) data file (EddyCovariance_MeteorlogicalVariables_CrestedButtePumphouse.csv). Additionally, three metadata CSV files are included: (1) location metadata file (locations.csv), which contains location metadata and coordinates; (2) a file-level metadata (flmd.csv) file that lists each file contained in the dataset with associated metadata; and (3) a data dictionary (dd.csv) file that contains column/row headers used throughout the files along with a definition, units, and data type.This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

54 ENVIRONMENTAL SCIENCES↗

Eddy Flux and Meteorology over Deciduous Forest, Prairie, and Soybean Ecosystems in Missouri, USA, during the Total Solar Eclipse of 2017

Eddy fluxes and meteorology data are reported at high temporal resolution for three flux tower sites in Mid-Missouri before, during, and after the Total Solar Eclipse of August 21, 2017. Mid-Missouri experienced up to 2 minutes and 40 seconds of totality at around solar noon during the eclipse (Fig. 1). The sites are located in deciduous oak-hickory forest, native prairie, and soybean ecosystems (Table 1 and Fig. 3). Eddy fluxes were computed using a wavelet-based approach that permitted the calculation of two-minute mean fluxes without losing low frequency flux contributions (Fig. 2). During the eclipse, standard meteorological variables were sampled and recorded at 5 second intervals. The two-minute means of fluxes and meteorology are reported. This data product includes three data files in NetCDF (*.nc) format, three data dictionary files and a file-level metadata file in comma separate (*.csv) format, and a user guide in PDF (*.pdf) format.

54 ENVIRONMENTAL SCIENCES↗

Characterizing Seasonal Variation of the Atmospheric Mixing Layer Height Using Machine Learning Approaches

As machine learning becomes more integrated into atmospheric science, XGBoost has gained popularity for its ability to assess the relative contributions of influencing factors in the atmospheric boundary layer height. To examine how these factors vary across seasons, a seasonal analysis is necessary. However, dividing data by season reduces the sample size, which can affect result reliability and complicate factor comparisons. To address these challenges, this study replaces default parameters with grid search optimization and incorporates cross-validation to mitigate dataset limitations. Using XGBoost with four years of data from the atmospheric radiation measurement (ARM) (Southern Great Plains (SGP) C1 site, cross-validation stabilizes correlation coefficient fluctuations from 0.3 to within 0.1. With optimized parameters, the R value can reach 0.81. Analysis of the C1 site reveals that the relative importance of different factors changes across seasons. Lower tropospheric stability (LTS, ~0.53) is the dominant factor at C1 throughout the year. However, during DJF, latent heat flux (LHF, 0.44) surpasses LTS (0.22). In SON, LTS (0.58) becomes more influential than LHF (0.18). Further comparisons among the four long-term SGP sites (C1, E32, E37, and E39) show seasonal variations in relative importance. Notably, during JJA, the differences in the relative importance of the three factors across all sites are lower than in other seasons. This suggests that boundary layer development in the summer is not dominated by a single factor, reflecting a more intricate process likely influenced by seasonal conditions such as enhanced convective activity, higher temperatures, and humidity, which collectively contribute to a balanced distribution of parameter impacts. Furthermore, the relative importance of LTS gradually increases from morning to noon, indicating that LTS becomes more significant as the boundary layer approaches its maximum height. Consequently, the LTS in the early morning in autumn exhibits greater relative importance compared to other seasons. This reflects a faster development of the mixing layer height (MLH) in autumn, suggesting that it is easier to retrieve the MLH from the previous day during this period. The findings enhance understanding of boundary layer evolution and contribute to improved boundary layer parameterization.

54 ENVIRONMENTAL SCIENCES↗

NGEE Arctic CO2, CH4 and Energy Eddy-Covariance (EC) Flux Tower Auxiliary Measurements, Utqiagvik (Barrow), Alaska, 2012 - 2019

Measurements began in September 2012 and are generally made throughout the snow-free growing season starting from April (pre-thawing) until November (freeze-up) when the instrumentation is taken down for maintenance and instrument calibration. CO2, CH4 and energy fluxes using the Eddy Covariance (EC) technique (Baldocchi 2003) and meteorological measurements are reported as 30-minute averages. The tower site is registered with AmeriFlux as US-NGB. See http://ameriflux.lbl.gov/sites/siteinfo/US-NGB for more information. Reported data include: (1) additional/extra meteorological and eddy covariance CO2, CH4 and energy flux data, (2) binned spectra for the three wind components, the sonic temperature and gas densities together with the binned cospectra for covariances of w (vertical wind component) and gas densities, (3) binned ogives (cumulative (co)spectra) for the three wind components, the sonic temperature and gas densities, and (4) tower site footprint matrices. Meteorological and eddy covariance CO2, CH4 and energy flux data (AmeriFlux BASE data product) are available from AmeriFlux https://doi.org/10.17190/AMF/1436326. The tower site is adjacent to the NGEE Arctic Tram system with several complementary time-series measurements https://doi.org/10.5440/1558782.This dataset supersedes the previously released dataset "Eddy-Covariance and auxiliary measurements, NGEE-Barrow, 2012-2013" DOI:10.5440/1124200 as this new product includes data for the longer time period processed using consistent methods for the entire record. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) near Utqiagvik (Barrow), Alaska and 2) multiple areas in the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Evaluation of the Near-Surface Variables in the HRRR Weather Model Using Observations from the ARM SGP Site

Abstract The performance of version 4 of the NOAA High-Resolution Rapid Refresh (HRRR) numerical weather prediction model for near-surface variables, including wind, humidity, temperature, surface latent and sensible fluxes, and longwave and shortwave radiative fluxes, is examined over the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) region. The study evaluated the model’s bias and bias-corrected mean absolute error relative to the observations on different time scales. Forecasts of near-surface geophysical variables at five SGP sites (HRRR at 3-km scale) were found to agree well with observations, but some consistent observation–forecast differences also occurred. Sensible and latent heat fluxes are the most challenging variables to be reproduced. The diurnal cycle is the main temporal scale affecting observation–forecast differences of the near-surface variables, and almost all of the variables showed different biases throughout the diurnal cycle. Results show that the overestimation of downward shortwave and the underestimation of downward longwave radiative flux are the two major biases found in this study. The timing and magnitude of downward longwave flux, wind speed, and sensible and latent heat fluxes are also different with contributions from model representations, data assimilation limitations, and differences in scales between HRRR and SGP sites. The positive bias in downward shortwave and negative bias in longwave radiation suggests that the model is underestimating cloud fraction in the study domain. The study concludes by showing a brief comparison with version 3 of the HRRR and shows that version 4 has better performance in almost all near-surface variables. Significance Statement A correct representation of the near-surface variables is important for numerical weather prediction models. This study investigates the capability of the latest NOAA High-Resolution Rapid Refresh (HRRRv4) model in simulating the near-surface variables by comparing against the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) in situ observations. Among others, we find that the surface heat fluxes, such as sensible and latent heat fluxes, are the most difficult variables to be reproduced. This study also shows that the diurnal cycle has the dominant impact on the model’s performance, which means the majority of the outputted near-surface variables have the strong diurnal cycle in their bias errors.

54 ENVIRONMENTAL SCIENCES↗