Search NASA⌕ Search

SEARCH · Search NASA

Results for “Separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

FY12 Final Report for PL10-Mod Separations-PD12: Electrochemically Modulated Separation of Plutonium from Dilute and Concentrated Dissolver Solutions for Analysis by Gamma Spectroscopy

Accurate and timely analysis of plutonium in spent nuclear fuel is critical in nuclear safeguards for detection of both protracted and rapid plutonium diversions. Gamma spectroscopy is a viable method for accurate and timely measurements of plutonium provided that the plutonium is well separated from the interfering fission and activation products present in spent nuclear fuel. Electrochemically modulated separation (EMS) is a method that has been used successfully to isolate picogram amounts of Pu from nitric acid matrices. With EMS, Pu adsorption may be turned “on” and “off” depending on the applied voltage, allowing for collection and stripping of Pu without the addition of chemical reagents. In this work, we have scaled up the EMS process to isolate microgram quantities of Pu from matrices encountered in spent nuclear fuel during reprocessing. Several challenges have been addressed including surface area limitations, radiolysis effects, electrochemical cell performance stability, and chemical interferences. After these challenges were resolved, 6 µg Pu was deposited in the electrochemical cell with approximately an 800-fold reduction of fission and activation product levels from a spent nuclear fuel sample. Modeling showed that these levels of Pu collection and interference reduction may not be sufficient for Pu detection by gamma spectroscopy. The main remaining challenges are to achieve a more complete Pu isolation and to deposit larger quantities of Pu for successful gamma analysis of Pu. If gamma analyses of Pu are successful, EMS will allow for accurate and timely on-site analysis for enhanced Pu safeguards.

Pratt, Sandra H.↗

Features of a separating turbulent boundary layer in the vicinity of separation

Laser anemometer measurements using a directionally sensitive system were obtained for a nominally two-dimensional separating turbulent boundary layer produced by an adverse pressure gradient. An airfoil-type flow was generated in which the flow was accelerated and then decelerated until separation. The results include the skin friction, mean velocity profiles, turbulent shear stresses and intensities, spectra, dissipation rate, turbulent/non-turbulent interfacial intermittency, and eddy speeds.

Simpson, R. L.↗

Measurements of Aircraft Wake Vortex Separation at High Arrival Rates and a Proposed New Wake Vortex Separation Philosophy

This paper presents data and a proposed new aircraft wake vortex separation standard that argues for a fundamental re-thinking of international practice. The current static standard, under certain atmospheric conditions, presents an unnecessary restriction on system capacity. A new approach, that decreases aircraft separation when atmospheric conditions dictate, is proposed based upon the availability of new instrumentation and a better understanding of wake physics.

Rutishauser, David↗

Process for separating carbon dioxide from flue gas using sweep-based membrane separation and absorption steps

A gas separation process for treating flue gases from combustion processes, and combustion processes including such gas separation. The invention involves routing a first portion of the flue gas stream to be treated to an absorption-based carbon dioxide capture step, while simultaneously flowing a second portion of the flue gas across the feed side of a membrane, flowing a sweep gas stream, usually air, across the permeate side, then passing the permeate/sweep gas to the combustor.

54 ENVIRONMENTAL SCIENCES↗

In search of chiral magnetic effect: Separating flow-driven background effects and quantifying anomaly-induced charge separations

Here we report our recent progress on the search of Chiral Magnetic Effect (CME) by developing new measurements as well as by hydrodynamic simulations of CME and background effects, with both approaches addressing the pressing issue of separating flow-driven background contributions and possible CME signal in current heavy ion collision measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adsorption, separation, and catalytic properties of densified metal-organic frameworks

Metal-organic frameworks (MOFs) are one of the widely investigated materials of 21st century due to their unique properties such as structural tailorability, controlled porosity and crystallinity. These exceptional properties make them promising candidates for various applications including gas adsorption and storage, separation, and catalysis. However, commercial applications of MOFs produced by conventional methods including solvothermal or hydrothermal synthesis are rather limited or restricted because they often produce fine powders. The use of MOF powders for industrial applications often results in pressure drop problems similar to the case with Zeolites. To realize these materials for practical applications, densification of MOFs is routinely employed to form pellets, extrudates or beads to improve the overall density, volumetric adsorption, mechanical and thermal properties. However, the improvements come with some drawbacks such as reduction in overall porosity, surface area, and gravimetric adsorption capacity. Thus, optimizing the properties of densified MOF’s by tuning the packing density is very crucial for realizing these materials for industrial applications. In this review, various methods of densification of MOFs, their properties, and applications are discussed.

Nandasiri, Manjula I.↗

Method development for comprehensive extraction and analysis of marine toxins: Liquid-liquid extraction and tandem liquid chromatography separations coupled to electrospray tandem mass spectrometry

Toxins from biological sources are recognized as potential chemical weapon threats, with saxitoxin and ricin listed by the chemical weapons convention (CWC) as schedule one agents (CWC reference). These two toxins represent a metabolite (saxitoxin) and protein (ricin) from algal and plant sources, respectively. An array of toxins have been listed as "select agents" by the Health and Human Services (HHS) select agent program, including ricin, abrin, saxitoxin, tetrodotoxin, specific paralytic alpha conotoxin peptides, T-2 toxin, diacetoxyscirpenols, botulinum toxins, and staphylococcal enterotoxins [1]. The quantities of these toxins dictate whether they are considered select agents with federal oversight of their storage and use. While this list captures some of the naturally occurring toxins that may pose a threat to the public, there are a number of other naturally occurring toxins that may also be a concern.

biodetection↗

Polysialylated N-Glycans Identified in Human Serum Through Combined Developments in Sample Preparation, Separations and Electrospray ionization-mass spectrometry

The N-glycan diversity of human serum glycoproteins, i.e. the human blood serum N-glycome, is complex due to the range of glycan structures potentially synthesizable by human glycosylation enzymes. The reported glycome, however, is limited by methods of sample preparation, available analytical platforms, e.g., based upon electrospray ionization-mass spectrometry (ESI-MS), and software tools for data analysis. In this report, several improvements have been implemented in sample preparation and analysis to extend ESI-MS glycan characterization and to provide an improved view of glycan diversity. Sample preparation improvements include acidified, microwave-accelerated, PNGase F N-glycan release, and sodium borohydride reduction were optimized to improve quantitative yields and conserve the number of glycoforms detected. Two-stage desalting (during solid phase extraction and on the analytical column) increased the sensitivity by reducing analyte signal division between multiple reducing-end-forms or cation adducts. On-line separations were improved by using extended length graphitized carbon columns and adding TFA as an acid modifier to a formic acid/reversed phase gradient which provides additional resolving power and significantly improved desorption of both large and heavily sialylated glycans. To improve MS sensitivity and provide gentler ionization conditions at the source-MS interface, subambient pressure ionization with nanoelectrospray (SPIN) has been utilized. When method improvements are combined together with the Glycomics Quintavariate Informed Quantification (GlyQ-IQ) recently described1 these technologies demonstrate the ability to significantly extend glycan detection sensitivity and provide expanded glycan coverage. We demonstrate application of these advances in the context of the human serum glycome, and for which our initial observations include detection of a new class of heavily sialylated N-glycans, including polysialylated N-glycans.