Search NASA⌕ Search

SEARCH · Search NASA

Results for “Setpoints”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A Multi-Instrument Cloud Condensation Nuclei Spectrum Product (Final Technical Report)

A wealth of observational data exists on the characteristics of atmospheric particulate matter, over multiple years, at the DOE ARM Southern Great Plains (SGP) Central Facility site. This site is located in a region of the country that frequently experiences weather extremes, and that is removed from many local sources of pollution but is affected by transported smoke, dust, and urban emissions. The relationships between particulate matter, cloud formation and evolution, and precipitation are therefore of strong interest, and are being explored via modeling on a variety of scales. These models require as input detailed information on the characteristics of particles capable of serving as the nuclei for cloud formation. Sufficient data exist to be able to put together a picture of the nature of the total aerosol and the cloud condensation nuclei (CCN) subset, and their variability, through merged data products. This study was aimed at exploiting the multiple measurement types at SGP to develop the first such multi-year estimates. Further, the resulting data were analyzed to understand temporal patterns ranging from hourly to seasonal, thereby gaining insights into the particle sources affecting the atmosphere in this region. DOE-funded datasets that were analyzed in this study include total particle number concentrations, submicron aerosol scattering coefficients, dry aerosol size distributions, and more recently, time-resolved submicron aerosol chemical composition. Data are also available for the number concentrations of particles that are activated in a cloud condensation nucleus instrument at a series of setpoint supersaturations, providing direct observations of the number concentrations of “CCN”. This variable is the quantity that is generally desired for inclusion in numerical models that seek to represent and predict the impacts of varying aerosol characteristics on the formation and microphysical properties of clouds. One limitation of the use of direct CCN observations is that they are not available for supersaturations larger than about 1%, which is insufficient for deep convection and may be insufficient even for shallow convection, depending on the nature of the available CCN and the dynamics of the cloud. We developed a data-based approach to representing the full aerosol size spectrum with size-dependent hygroscopicity, and used this to extrapolate CCN spectra beyond the limited measurements. Five years of SGP aerosol data (2009 -2013) were analyzed. As a side product of our work, we identified and communicated several previously-unflagged data quality issues. The resulting merged aerosol distributions, along with fits for seasonal averages, were published and submitted to the ARM archive as a special value-added product (VAP; submitted as a PI product). CCN spectra were computed for the same data period and will similarly be published and submitted to the archive for use by the community. We also note that our methodologies and findings have been discussed at several Joint ARM User Facility/Atmospheric System Research (ASR) Principal Investigators Meetings and that recent ARM/ASR aerosol data reporting strategies have included similar ideas for data merging, indicating that this work has had a lasting impact on ARM aerosol data acquisition and reporting. The proposed work advances the science of the interactions of aerosols, clouds and precipitation, with direct application to improve representation of such interactions for clouds in regional and global climate models. The archived data will continue to serve research studies in the future.

54 ENVIRONMENTAL SCIENCES↗

A System Approach to Deep Heating Savings Through Measurement, Management, and Motivation

Across multi-tenant commercial office and multifamily buildings, centrally metered fuel use represents a substantial fraction of whole-building energy use. Energy audit practitioners understand that improving heating distribution efficiency is typically more of an opportunity than combustion efficiency and that differing thermal comfort preferences between tenants are the bane of operators across these building typologies. There is an unmet market need for retrofit technologies that allow for the delivery of the right amount of heat to the right spaces, at the right time. The Energy Management and Information System (EMIS) package fills this gap through enhanced controls and metering, incorporating low-cost sensors and wireless communication infrastructure to provide a platform for ongoing commissioning and tenant feedback, including heat cost allocation. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Sentient Buildings, E Source, building owners, and utility and policy stakeholders, to demonstrate a market viable EMIS that achieves a reduction in space heating energy use by reducing heating load, improving control, and positively impacting behavior while providing an acceptable financial return. In this study, EMIS packages were implemented in two New York City multifamily rental buildings. Both buildings conducted basic mechanical work (e.g., repairing steam traps) to ensure the heating system was operating well before any tenant feedback was layered in. Heating Energy Use Reports (HEUR) were created to provide tenants with social comparisons and energy savings tips to influence their behavior; these were provided monthly to all tenants in both buildings. Additionally, one building allocated heating costs to a portion of the tenants. Heat cost allocation (HCA) has a long history in the European Union (EU), although it is not common in the US or in steam-heated buildings. SWA leveraged existing EU best practices and stakeholder feedback to develop a Heat Cost Allocation algorithm that was considered equitable and intuitive. Energy use and tenant behavior impacts were tracked throughout the study. The basic mechanical repair work saved between 11-20% of heating energy. Those savings rose to 17-24% with the addition of tenant feedback. While it may not be possible to precisely determine the impact of COVID-19 on research studies like this, there may have been additional savings realized had the study taken place in a period of normal occupancy patterns. These types of central heating systems have been a blind spot for utilities, who have traditionally had little visibility into detailed behind-the-meter gas usage. Heating energy savings stayed consistent during the coldest months, indicating the potential for utilities to utilize EMIS packages for peak gas demand reductions or demand response programs. Tenant comfort was also improved. Post installation, room temperatures more closely matched thermostat set points. Perhaps due to this greater level of control, the vast majority of tenants being billed for heating were accepting of the allocation costs. And tenants receiving heat cost allocations were more likely to reduce their thermostat setpoints than tenants receiving behavioral feedback without financial impacts were. Variation in building specifics makes it difficult to provide precise energy and financial savings estimates. But within the range of expected conditions, the study identified a few key variables that can have the greatest impact on financial returns: the cost of fuel, the ability and willingness to allocate heating costs to tenants, and a well-functioning heating system as a starting point. This study focused on two multifamily buildings, but additional use cases, such as commercial buildings and affordable housing, should be explored to better understand the full market potential. While this type of upgrade has the potential for deep energy reductions and cost savings, future projects should take into account the balance of costs and benefits between owners and tenants, especially in the affordable, regulated, or other low-to-moderate income (LMI) segments of the market. Rent credits, utility allowances, or a shared savings program are possible options to accelerate adoption of this strategy in these market segments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mitigating Phase Unbalance for Distribution Systems with High Penetrations of Solar PV (Final Technical Report)

Distribution system operators have traditionally limited unbalance among phases by maintaining similar loadings on each phase. High penetrations of distributed solar PV continually change the net loading on each phase, resulting in time-varying phase unbalances that can damage three-phase devices such as three-phase motors, violate grid codes, and increase technical losses. This project has developed several control strategies for the reactive power outputs of solar PV inverters in order to mitigate power quality issues related to phase unbalance. These control strategies include a decentralized approach that is solely based on local measurements, distributed and grouped approaches that consider subsets of loads and PV generators, and a centralized approach that leverages measurements from a variety of locations in order to compute optimal reactive power setpoints for each inverter. Variants of the controllers handle challenges relevant to practical implementations, including noisy measurements, delayed communications, and reactive power limits. Moreover, the project developed theory that provides convergence guarantees for systems with multiple interacting controllers as well as “balanceability” certificates that ensure satisfaction of phase unbalance requirements with variable loading. The controllers were integrated with NRECA’s Open Modeling Framework (omf.coop) and evaluated using actual distribution system models obtained from several NRECA member utilities. Application of the controllers results in significant improvements to phase unbalance in these test cases with decreases from base case levels of over 3% to under 0.5%, which is within the 2% IEC phase unbalance standard.

14 SOLAR ENERGY↗

Smart Building Start (SBS) (CRADA 480)

The idea of Smart Building Start (SBS) is to manage the on/off scheduling of HVAC equipment in buildings in an optimal way in order to achieve comfort conditions at the designated times with the minimal use of energy. This concept is also known as Optimal Start and it has typically been used in buildings to start up equipment based on predictions made for a representative (or average) zone in a building. This means that zones that could have waited longer to receive conditioned air are activated too early leading to unnecessary energy loss. The approach proposed in this project is to develop and implement a distributed version of optimal start that will consider the individual requirements of all treated zones. The developed control strategy will enable smart start of the central plant as well as further localized control over each individual zone by means of setpoint adjustment so that zones are not conditioned too early thereby reducing energy use compared to the current state of the art. This project is a collaboration between PNNL and Verdicity with the goal being to bring the research concept of SBS to commercialization. The SBS algorithm(s) will be implemented and hosted on the PNNL-developed open-platform VOLTTRON which will accelerate bringing the research to practice. It is anticipated that this project will lead to new IP surrounding the algorithm and its decentralized deployment. The project will also further demonstrate the success of VOLTRON as a flexible platform for implementation of innovative algorithms for improving energy efficiency in buildings. Previous studies on smart building start carried out by PNNL have indicated potential energy savings on the order of 10-15% for multi-zone buildings compared to conventional strategies. Verdicity currently has a number of customers who can benefit from the use of this technology. PNNL will work with Verdicity to identify any key gaps in the integrated software and jointly work to enhance and customize it for Verdicity and to integrate it with their existing products for use at their customers’ sites. The proposed work will help previously funded Federal research and development technology investments find their way into a viable commercial market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automation of FARM from Alpha Phase to Beta Phase

Integrated energy systems (IES) combine different energy technologies in synergistic ways to achieve a more secure and economical energy supply. The RAVEN-based HYBRID framework and the RAVEN plugin for grid and capacity optimization (HERON) are used to find the optimal installed capacity and the optimal economical dispatch of each component of the IES, by respecting the limits on the production variables and the corresponding rates of variation (explicit constraints). Besides, there are other process variables whose evolution needs to be bounded to avoid damaging the components (e.g., condensers, heat exchangers, steam generators, etc.) or degrading the process efficiency (e.g., electrolysis in the hydrogen production process). To avoid violating these latter limits (implicit constraints), a proof-of-concept HERON validator based on Feasible Actuator Range Modifier (FARM-Alpha) was developed by Argonne National Laboratory in January 2021. This FARM-Alpha validator calculates the evolution of process variables on whom the implicit constraints are placed, and then provides feedback to HERON dispatcher to adjust the power setpoints of three IES components, i.e., Balance of Plant, Secondary Energy Source, and Thermal Energy Storage, so as to meet both the explicit and implicit constraints. FARM-Alpha was designed to assess the performance of FARM as a HERON validator only, i.e., the list of components and implicit operational constraints were hard-coded within the source code. The lack of flexibility of the corresponding software structure does not allow the deployment in production environment. This report describes the development and the implementation of an enhanced version of the FARM-based validator (FARM-Beta), which ensures more flexibility for the end user in modeling multiple IES configurations and scenarios. Several test cases of the power dispatch problem were then selected to demonstrate the capabilities offered by FARM-beta. The test cases illustrate the efficiency of the closed-loop optimization scheme and the capability to calculate set-point trajectories satisfying both explicit and implicit constraints.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Thin Film Core Technology: CIGS Final Technical Report (FTR)

Cu(In,Ga)Se 2 (CIGS) thin-film photovoltaics are a high-efficiency and reliable technology. This project completed research in two important areas and was designed to work collaboratively with industrial partners. Task 1: Alkali Science focused on alkali post-deposition treatments (PDT). PDTs have been instrumental in the dramatic voltage improvements that have moved CIGS device efficiencies from 20% to 23.35% [1]. Based on a survey of CIGS companies at the beginning of the project, the single biggest breakthrough for the CIGS community would be a mechanistic understanding of the role of alkalis in the material system. Significant accomplishments of Task 1: Alkali Science: 1) KF post-deposition treatments were shown to improve lifetime, open-circuit voltage (VOC), and efficiency of industrial partner samples, even when done as a later step, separate from the original CIGS deposition. 2) KF boosted efficiency when incorporated at the end of the third stage of NREL CIGS growth. 3) XPS characterization of CIGS surfaces with and without PDTs led to a proposed mechanism whereby K drives structural transformation at 350 degrees C that is locked in at room temperature even after K is rinsed away. 4) Published recipes for KF and RbF PDTs. Literature to date did not provide enough detail to quickly reproduce experimental results. 5) Identified most important parameters (RbF cell temperature and lamp setpoint temperature) and set boundaries for successful RbF PDTs. The purpose of Task 2: Cell-level Reliability was to overcome the largest challenges to investor confidence and long product lifetime in CIGS-based photovoltaic products: metastability, shading-induced hot spots, and potential-induced degradation (PID). Key findings were made in each of these areas by studying CIGS reliability at the cell level: 1) Published NREL's cell-level reliability testing procedures along with challenges that were encountered while developing them. These were also distributed to the community through an MRS conference presentation. 2) Decreased metastability by adding a CdS hole-injection layer between the CIGS and Zn(O,S) in the device stack. It also improved device performance. Materials other than CdS can be used for the same purpose. 3) Reduced front-glass PID by replacing soda-lime glass with low-Na borosilicate glass. 4) Found that PID depends on leakage current and light/electrical bias. This will help labs avoid test-specific degradation. 5) Discovered that CIGS can suffer from two different types of PID with different mechanisms. Front is slower and leads to shunting ZnO. Back is faster and degrades the p-n junction. 6) Holding cells at open circuit slows PID compared to short circuit. This affects testing protocols for glass/glass modules.

14 SOLAR ENERGY↗

Grid-Connected Modular Soft-Switching Solid State Transformers (M-S4T)

The objective of this project is to develop and verify the concept of a flexible and modular soft-switching solid-state transformer (M-S4T) for direct grid-connected applications. The ability to directly connect power electronics converters to the medium voltage grid (4 kV – 13 kV), and to potentially replace the passive and bulky, but ubiquitous 60 hertz service transformer in the 25 kVA to 100 kVA range, with a more flexible and controllable device, has been regarded as the ‘holy grail’ in grid control. However, this has proven to be extremely difficult. This project has developed the solutions to several key challenges of the direct grid-connected power electronics and realized a 7.2 kV M-S4T prototype. First, a protection method to protect the M-S4T from the high voltages (110 kV for the 13 kV system) that occur on the grid due to transients and lightning strikes have been developed and experimentally verified. Second, the realization and the operation of the M-S4T based on high-voltage SiC devices (>3.3 kV) and a medium-frequency medium-voltage low-leakage transformer in a single-stage solid-state transformer with zero-voltage switching, low dv/dt, and low electromagnetic interference has been successfully demonstrated up to 7.5 kV peak. Third, an oil-cooling system and stable communication and distributed control system for converter module voltage sharing have been developed and experimentally verified. The developed M-S4T has realized a modular universal high-performance power conversion system. This conversion system is scalable to different voltage and power levels and adaptable to four-quadrant bidirectional operation. Moreover, the use of passive cooling techniques meets the equipment life requirements, and the lightning protection scheme fulfills the basic insulation level specifications for direct grid connection. Such power conversion system opens up near-term opportunities, including energy storage, solar PV, or electric vehicle charging with significant cost and footprint savings. In the longer term, the possibility of replacing the utility distribution transformer with an M-S4T will be transformative for future distribution grids with a compact footprint and full controllability to enable high renewable energy and storage penetration. In addition to the main project, this report expands on the Plus-Up projected including as part of the main award. This project developed and demonstrated the technology for autonomous collaborative inverters that can be connected in an ad hoc manner to the grid. The aim of the project was to: (1) evaluate the existing techniques for grid-connected inverters and find their limitations; (2) develop detailed requirements for grid-connected inverters in the modern grid with millions of active nodes; (3) design a unified control strategy that brings more autonomy and intelligence to grid-connected inverters, and addresses parts of the issues with the existing techniques. The proposed technique, called UniCon, enables inverters to 1) connect/disconnect to/from the grid in an ad hoc manner; (2) work based on local sensing. Slow communication could be used for a more optimized behavior; (3) work automatically in both grid-forming/grid-following mode; (4) handle large disturbances, e.g., big load step and fault, in an oscillation-free manner; (5) work collaboratively with other inverters in steady-state and during transients. UniCon can be implemented in the middle-level control; hence it is agnostic to the vendor and to the implementation of the inner voltage/current and protection loops. Furthermore, a new synchronization scheme, based on deep learning, was developed that can extract the grid voltage phase and amplitude in a stable manner. The method is cheap to implement can improve the dynamic performance of the grid-connected inverters during fast transients, e.g., fault. The proposed control scheme was validated by (1) MATLAB/Simulink; (2) hardware-in-the-loop results, and; (3) experimental results using three inverters that form a microgrid in a down-scaled feeder. Lastly, both the M-S4T and UniCon have achieved promising tangible paths to markets. In the case of the M-S4T, the underlying technology — the Soft Switching Solid State Transformer (S4T) developed at the Georgia Tech Center for Distributed Energy (GT-CDE) has been licensed by GridBlock from the Georgia Tech Research Corporation, and GridBlock has been working with manufacturing partner Jabil (one of the largest US-based contract manufacturers) and system integrator Power Secure (largest deployer of microgrids in the US with 4.7 GW under management), to meet the strong initial demand. Similarly, GridBlock has an exclusive license to the UniCon technology, developed under this award by GT-CDE. The UniCon provides an intermediate control layer that enables the implementation of the higher-level ‘transactive’ control commands for the system. The architecture of the system - slow communications with the cloud for system optimization and setpoints, and the use of locally measured quantities for real-time control, provide a very robust and secure way of implementing a real-time must-run grid that is also secure and stable. This is a brand-new functionality that is critical for the future grid and key to GridBlock’s business model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Powertrain Performance and Total Cost of Ownership Analysis for Class 8 Yard Tractors and Refuse Trucks

Advanced powertrain technologies, specifically fuel cell electric powertrains, have gained attention as viable alternatives for medium- and heavy-duty (M/HD) vehicles. However, it is unclear how these alternative powertrain vehicles stack up against their diesel counterparts in terms of performance and total cost of ownership (TCO). Furthermore, there are vehicle segments within the M/HD sector that have remained unstudied for fuel cell electric applications. This analysis aims to provide a comparative scoping-level TCO and performance analysis for two heavy-duty vocation vehicles (Class 8 U.S. port-side yard tractor and Class 8 U.S.-based refuse truck) for both conventional diesel and heavy-duty fuel cell electric (HDFC) powertrains. The refuse truck analysis also considered compressed natural gas powertrains (CNG) for comparison. The analysis includes seven timeframes (2020, 2025, 2030, 2035, 2040, 2045, and 2050) for comparison. This simplified TCO analysis includes only direct costs (fuel price, glider purchase price, and operating & maintenance costs) and excludes any associated indirect cost (e.g., dwell time costs and other opportunity based costs). Representative drive cycles for each vehicle were based on on-board GPS logged data and chosen by the analysis team to represent average, non-extreme driving conditions. At the time the analysis was performed, the Inflation Reduction Act was not in effect and therefore any potential subsidies and future cost reductions enacted under the Inflation Reduction Act were not included. Based on the operational setpoints used in this analysis, HDFC powertrains for both yard tractors and refuse trucks have the potential to achieve TCO advantages over conventional diesel powertrains (and CNG for refuse truck applications) in the near- to mid-term future while meeting the necessary duty cycle performance requirements. Yard tractors and refuse trucks spend a significant amount of time operating at low speeds, with long durations of idling, and experience numerous start/stop occurrences. These operational characteristics favor fuel cell performance as fuel cells operate with higher efficiencies at lower percentages of total power output. Conversely, conventional diesel and CNG engines are most efficient at higher percentages of total power output. This helps HDFC powered yard tractors and refuse trucks realize improved fuel economy when compared to their diesel counterparts, which helps reduce total fuel costs and therefore, total TCO. The analysis demonstrates that fuel prices play a significant role in determining TCO for each vehicle and should remain an R&D focus area. Overall, under the analysis' specified conditions, HDFC yard tractors have the potential to achieve cost parity with diesel yard tractors as early as 2025. For refuse trucks, HDFC refuse trucks have the potential to achieve cost parity with diesel and CNG refuse trucks in 2030 and 2040, respectively.

33 ADVANCED PROPULSION SYSTEMS↗

Application of FARM to an IES scenario within the FORCE ecosystem

The FARM (Feasible Actuator Range Modifier) software module is a component of the RAVEN-based FORCE framework for analysis of Integrated Energy Systems (IES). FARM supports the HERON software module in the evaluation of the optimal dispatch by evaluating feasible set-points for the different IES unit components. Set-points are required to satisfy limits on both production variables (i.e., the variables to be optimized such as the electrical power, the hydrogen production rate, etc.) and process variables tied to the service life of equipment (e.g., steam flowrate, vessel pressure, turbine firing temperature, etc.). This problem is addressed by adopting a two-stage approach. First, the HERON power dispatcher determines set-points that meet the constraints on the former variables (e.g., power levels and power ramp rate limits). These constraints are called explicit constraints. Then, FARM adjusts these set-points to ensure the respect of the limits on the latter variables given the knowledge of the system physics acquired through machine learning algorithms. These constraints are called implicit constraints. From this standpoint, FARM constitutes a bridge between the HERON power dispatcher that adopts a simplified description of the IES unit (low-resolution physics) and the HYBRID high-fidelity models (high-resolution physics). The original version of the FARM software module (FARM-Alpha) was released by Argonne National Laboratory in January 2021. In the latest version of the code released in July 2022 (FARM-Delta), the Reference Governor (RG) algorithm was upgraded to a Multi-Input Multi-Output version from its original Single-Input Single-Output form. The RG algorithm acts to enforce constraints. With this improvement an IES unit is now treated as a single dynamic system from the standpoint of control. The crosstalk among components in an IES unit is now fully considered thereby ensuring a true optimization is obtained for those units that have multiple set-points. In this report, the capabilities of FARM-Delta operating within the FORCE ecosystem are demonstrated for an IES test case. The specific configuration of IES unit for this case was selected by the IES team with consultation from the Advanced Reactor IES Expert Group. A full TEA analysis that invoked HERON, HYBRID, FARM, and RAVEN was performed and serves to demonstrate how the latest modification to FARM algorithms (i.e., state variable selection, state-space matrices derivation, set-point verification) can shape setpoints that might otherwise compromise the health of equipment through accelerated wear and tear. In this specific test case, it was demonstrated that these algorithms ensure a more efficient utilization of steam resources to be shared by two different subsystems, namely Balance of Plant (BOP) and High-Temperature Steam Electrolysis (HTSE). Finally, some code improvements that can further enhance the user-friendliness are suggested.

97 MATHEMATICS AND COMPUTING↗

Preliminary Development of Heat Transfer Model-Based Control Algorithms of Liquid Sodium Purification System: Advanced Sensors and Instrumentation Advanced Controls

Monitoring the operation of sodium purification system is essential for efficient operation of sodium fast reactors. In this work, a heat transfer model has been developed for monitoring the plugging meter and cold trap systems at the Mechanisms Engineering Test Loop (METL) liquid sodium facility at Argonne National Laboratory. The model of the purification system was developed by treating the respective aspects of the cold trap purification loop and plugging meter diagnostic loop as two separate control volumes using information from the METL piping and instrumentation diagram (P&ID). A model predictive controller was designed using first order differential equations with the specified boundary conditions. The system behavior was studied with a tuned optimized procedure using the internal cold trap temperature and plugging meter outlet temperature as control variables, and the air blower temperature as an independent variable respectively. Results of computer simulations obtained in this study compared favorably with experimental data showing very good reference tracking response with negligible overshoot as both plugging meter and cold trap physical models approach the setpoint.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Skewering the silos: using Brick to enable portable analytics, modeling and controls in buildings

Nearly all large commercial buildings have heating, ventilation and air conditioning (HVAC) systems, lighting systems, safety and other systems controlled by a computer—a dedicated server with a building energy management system (BMS). However, these BMSs are proprietary with each building’s assets (that is, fans, valves, pumps, and their setpoints) named and coded uniquely by the BMS vendor or engineer; building analytics and control algorithms are written specific to the assets and the building. Thus, any control updates or analytics to improve building performance—especially critical to reduce greenhouse emissions or improve load flexibility—are labor intensive and costly. The Brick schema was developed so the same analysis or control algorithms can work on a variety of buildings if each is digitally represented in a Brick data model. The goal of this project was to further the development of Brick to extend it beyond an academic project with demonstrated success in a small field study, to a practical choice for industrial and commercial stakeholders seeking to realize value from building data. To do this, we executed four objectives: (1) expand the Brick schema including its modeling capabilities and vocabulary, (2) develop tools for integrating Brick with existing digital technologies and representations in buildings, (3) develop an open-source analytics platform to facilitate use of Brick in delivering data value, and (4) demonstrate Brick-driven analytics and controls in real settings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstrating Load-Shaping Capabilities of Cost Minimizing Heat Pump Water Heater Controls with Varying Price Profiles

Increased penetration of photovoltaics and electrification of traditionally gas appliances are exacerbating existing challenges in cost-effectively balancing electricity grid supply and demand. Decarbonization without incurring expensive transmission and distribution system capacity increases requires shifting building loads from peak demand times to peak renewable production times. Grid operators are evaluating new ways of encouraging load shifting, including using time-varying price structures to provide a financial incentive. If devices incorporate price-responsive controls, a price profile could be designed to yield a wide variety of load curves as needed to optimize grid functionality. Heat pump water heaters (HPWHs) are an ideal device for price-responsive controls because the storage tank enables them to optimize the timing of electricity consumption without impacting hot water delivery service. This paper presents work demonstrating how price-responsive controls for HPWHs can provide different load profiles, as needed to stabilize the grid, in response to different price profiles. HPWH manufacturers now include web API and CTA-2045 communication capabilities which enable sending load shaping control signals. Pilot studies and preliminary programs have utilized these capabilities with uniform control strategies to reduce 4-9 PM electricity consumption. However, no studies have developed flexible controls capable of both a) responding to constantly varying price profiles and b) customizing logic to match the needs of each HPWH. Berkeley Lab's CalFlexHub project is pioneering price-driven load flexibility by developing and deploying cost-minimizing controls utilizing setpoint setting signals for fleets of HPWHs in response to varying price profiles. Control development is based on simulations using the Flexible Heat Pump Water Heater Performance Predictor which captures the control decisions of a residential, integrated HPWH manufacturer’s on-board controller. The proposed cost-reducing controls respond to constantly changing price profiles, providing the ability to change the price profile to generate load curves as needed to maintain grid stability. Preliminary simulations studying the load shaping capabilities of price-responsive controls on a fleet of 60 HPWHs have demonstrated an average of a) 135.4% increases in load during low-price periods, b) >36.8% reductions in electricity peak-price period, and c) 6.2% electricity cost savings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Component-to-Optimization Workflow Demonstration

This report aims to demonstrate workflow-generating algorithms for optimizing dispatch across a broad range of Integrated Energy System applications using the Framework for Optimization of Resources and Economics (FORCE) tool suite. The optimization is performed at two different time scales. In the coarse time scale, the optimization focuses on a class of energy sources and consumers and aims to find the optimal combinations and flows of energy based on real-time price data information. In the fine time scale, the optimization focuses on a specific thermal energy delivery system and aims to find the optimal setpoints of components in order to meet the energy demands from coarse-time-scale optimizations. In this demonstration, the coarse-scale optimization is implemented using the newly developed Dispatch Optimization Variable Engine (DOVE), while the fine-scale optimization used Optimization of Real-Time Capacity Allocation (ORCA).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Faster-than-real-time Simulation with Demonstration for Resilient DER Integration

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. The Faster-than-real-time Simulation with demonstration for Resilient DER Integration project set out to do the following: a. Flatten the voltage profile through the feeders and system for cost saving and voltage stabilization needs. b. Increase the amount of intermittent distributed energy resources (IDERs) that could be deployed on a utility feeder and provide 100% or more energy needed for the demands on that feeder, and c. based on an accurate model (Digital Twin) of the utilities system, be able to detect any abnormalities on the utilities distribution system. To manage the voltage and increase IDER penetration (a,b), Graph Trace Analysis is employed in a time-series, optimal power flow to coordinate the time-varying feedback control setpoints of a distribution feeder’s utility control devices. Under the coordinated control are a Load Tap Changing Transformer, a voltage regulator, and five switched capacitor banks. The feeder serves over 2000 customers, the feeder secondaries are modeled, and the feeder has 2.3 MW of PV generation, corresponding to a 17.4% penetration of PV generation. The feeder model has over 12,000 components, where every customer load bus and PV generator are modeled. The accuracy of the power flow solution is compared against historical meter voltage measurements, the improvement in conservation voltage reduction energy savings as a function of the coordinated control desired voltage profile is investigated, and the increase in PV penetration of the coordinated control over the existing control is presented. To achieve improved control performance while observing system operation constraints, bellwether Advanced Metering Infrastructure (AMI) voltage measurements are used to adjust the desired voltage profile used by the optimal power flow analysis. To detect and alleviate or negate attacks or failures on the distribution and transmission utility grids (c) the grid needs to be resilient and self-healing. In this project software was designed to do just that. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hard-ware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

Integrated System Model, Graph Trace Analysis, Adv↗

Hardware Specification and Reference Design for the Low-Cost, Interoperable, User-Centric, Supervisory Controller Kit for Small and Medium Size Commercial Buildings

Commercial buildings are responsible for approximately 20 percent of the total United States energy consumption and greenhouse gas emissions. Over 85 percent of these buildings lack building automation systems to manage the various building systems they have. Many of these buildings are small (< 50,000 square feet), underserved, and use rooftop units (RTUs) for heating, ventilation, and air-conditioning needs. Because these buildings lack proper control systems, they have several operational deficiencies that lead to excess energy consumption. Studies have shown that managing the RTU’s heating and cooling setpoints, schedules, setbacks, and optimal start times can result in 20 to 25 percent reduction in electricity consumption in small and medium commercial buildings (SMBs). In addition, improving the demand flexibility of these buildings will result in additional cost savings for the building owner. To address the needs of the SMBs, the Department of Energy’s Building Technologies Office jointly funded Pacific Northwest National Laboratory (PNNL) and Oak Ridge National Laboratory (ORNL) to design, develop, test, and validate a low-cost, interoperable, user-centric, retrofit supervisory controller kit (SC-SMB) that can be used to continuously optimize energy consumption and deliver demand flexibility of SMBs, including all-electric buildings, and provide a means for maximizing decarbonization benefits. The team also includes industry partners Edo and Intellimation. Previously, the team drafted an SC-SMB system specification document (Goodman et al. 2023). This document describes a reference design of a low-cost supervisory control system for SMBs, including the various hardware components, software system, and an example implementation of the reference design. The final release of the reference design is planned for December 2025. Section 2.0 of the report documents the relevant building types that the SC-SMB system is suitable for. Section 3.0 documents the various hardware components, their function, cost, whether they are off-the-shelve, support standard communication, etc., and the software system. An example deployment in a 10,000-sf building with six rooftop units, a hot water heater, solar, and storage is described in Section 4.0. The planned next steps are described in Section 5.0, and references are listed in Section 6.0.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design Requirements and Hardware Specification for the Low-Cost, Interoperable, User-Centric, Supervisory Controller Kit for Small and Medium Size Commercial Buildings

Commercial buildings are responsible for approximately 20 percent of the total United States energy consumption and greenhouse gas emissions. Over 85 percent of these buildings lack building automation systems to manage the various building systems they have. Many of these buildings are small (< 50,000 square feet), underserved, and use rooftop units (RTUs) for heating, ventilation, and air-conditioning needs. Because these buildings lack proper control systems, they have several operational deficiencies that lead to excess energy consumption. Studies have shown that managing the RTU’s heating and cooling setpoints, schedules, setbacks, and optimal start times can result in 20 to 25 percent reduction in electricity consumption in small and medium commercial buildings (SMBs). In addition, improving the demand flexibility of these buildings will result in additional cost savings for the building owner.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Update on Microreactor Automated Control System (MACS)

Automation of control systems is expected to be important in the economic and safe operation of microreactors. There is a need to develop and demonstrate automated control for microreactors, along with the development of testbeds for this purpose. This report provides updates on the status of a microreactor automated control system (MACS) testbed developed to test control system automation. While a future goal is to demonstrate this system using a prototypic microreactor such as MARVEL, the present focus is on developing and testing within a non-nuclear testbed. The testbed, developed in collaboration with Idaho National Laboratory, includes hardware-in-the-loop simulation and uses a Modelica-based model of a prototypic microreactor for use in testing control automation. Research to date at Oak Ridge National Laboratory has focused on the development of prototypic software for automating plant-level control under selected scenarios. Empirical testing on the integrated MACS testbed was performed to quantify key characteristics of the integrated testbed and to demonstrate the use of the software for automating the calculation and use of actuation setpoints for selected load-following scenarios. Ongoing research is focused on integrating additional control algorithms that utilize data from newly included sensors within the MACS hardware testbed, as well as demonstrating and assessing the performance of the different automated control algorithms on multiple additional operational scenarios.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Building ControlScore: Research Laboratory Building Deployment

Improvements to building control systems can lead to energy savings and increased occupant comfort. In an optimized system, process variables such as air temperature will closely follow their desired setpoints and avoid excess energy use. Typically, experts must manually inspect individual control loops to identify poor performance and opportunities for improvement. However, this approach is difficult in modern buildings that have a prohibitively large number of controllers. To address this issue, Pacific Northwest National Laboratory (PNNL) created the ControlScore tool which captures operating data from the many controllers within a building and generates standardized scores for each loop on a scale of 0 to 10 (a score of 0 indicates poor control, a score of 10 indicates good control).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗