Search NASA⌕ Search

SEARCH · Search NASA

Results for “Source Code Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Benchmark studies among own and commercial beam tracking codes on fundamental conditions

In order to design accelerators or to analyze experimental data, commercially or noncommercially programs for tracking particles have been developed and used. However the reliabilities of those programs are not clear, especially if the beam quality is as high as that required for future applications. Therefore, for the purpose to study the reliabilities and to improve their accuracy, we planed to benchmark those programs. As a first step, the calculations were carried out in the both condition of free space and homogeneously accelerating-field by using three own codes and three commercial codes (MAGIC, PARMELA, and GPT)

43 PARTICLE ACCELERATORS↗

Final remnant of binary black hole mergers: Multipolar analysis

Methods are presented to define and compute source multipoles of dynamical horizons in numerical relativity codes, extending previous work in the isolated and dynamical horizon formalisms to allow for horizons that are not axisymmetric. These methods are then applied to a binary black hole merger simulation, providing evidence that the final remnant is a Kerr black hole, both through the (spatially) gauge-invariant recovery of the geometry of the apparent horizon, and through a detailed extraction of quasinormal ringing modes directly from the strong-field region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ORBUMP Pulsed Dipole Magnet Design for Fermilab Booster

Fermilab initiated the accelerator magnet system upgrade project PIP-II for future neutrino experiments. Old ORBUMP pulsed dipoles should be replaced with new stronger magnets occupying the same space as old ones. Four of these magnets connected in series form dogleg type of proton beam orbit. The magnet field and 19 kA current pulse length are close to 1 ms. Old magnet cores were based on a ferrite material. For new magnets, a magnet gap field is above 0.4 T, which completely saturates ferrite material. So, for the magnet core, 0.127 mm thick laminations of low carbon steel with inorganic coating, as the magnet were placed in a vacuum box. There were investigated transient magnet parameters including skin effect in the iron core and in the single-turn copper coil. The integrated field homogeneity was improved by the copper coil shimming. Simulated by OPERA3D power losses were used for the thermal analysis by ANSYS code. The magnet performance is strongly coupled with the power source. The dynamic magnet inductance and resistance were included in the pulsed power source design. Finally, the paper presented the ORBUMP magnet system design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Relationship Between Dose Rate and Decay Heat for Spent Nuclear Fuel Casks

Decay heat and dose rate are two important limits used for determining the allowable contents of spent fuel (SNF) in dry storage systems and transportation packages. While the decay heat limit is used to maintain fuel cladding integrity and ensure retrievability, dose rates are used to demonstrate compliance with regulatory requirements on radiation protection. Because both dose rate and decay heat result from decay of radioisotopes in SNF, this study is an attempt to examine the relationship between dose rate and decay heat for a given cask design. Dose rates were evaluated for 198 cask configurations, that include various SNF system designs (e.g., storage, transfer, transport), SNF characteristics (e.g., fuel types, burnup, cooling time), and loading maps (e.g., uniform loading, zone loading), while a constant decay heat was maintained. The decay heat was calculated using US Nuclear Regulatory Commission (NRC) Regulatory Guide (RG) 3.54, Revision 2, and verified using ORIGEN sequence within SCALE code system. The ORIGEN outputs were used as source terms in the dose analysis using 198 different configurations. A computer script was developed to calculate the cooling time necessary to achieve a given decay heat for a given enrichment, assembly average burnup, assembly mass, and in-core history using a rootfinder algorithm. Initially the computer script was developed to provide cooling time and burnup calculations directly to the analysis of dose rates and decay heats, so a comparison between Used Nuclear Fuel-Storage Transportation and Disposal Analysis Resource Data System (UNF-ST&DARDS) results and RG3.54 data was made; results are included in the appendix to this document. However, an iterative approach was used to compute cooling time, and its accuracy did not depend on the results of the RG3.54r2 algorithm, although the algorithm was still used. The results of the evaluation presented herein clearly demonstrate that a given decay heat does not correspond to a unique dose rate for a variety of cask and package designs. There is no clear pattern to develop a correlation between decay heat and the source terms. Depending on burnup, enrichment, cask type, and loading pattern, dose rates varied for the exact same decay heat—in some cases by 400% for a given cask. For cases in which decay heat was held constant through selection of the appropriate cooling time, dose rates would decrease with increasing burnup, and in other cases, dose rates would increase. The large variation in dose rates for a constant decay heat indicates that casks loaded based on decay heat—that is allowing any burnup, cooling time, and enrichment combinations that yield the qualified decay heat limit(s) —cannot ensure that an Independent Spent Fuel Storage Installation or a spent fuel transportation package will meet the regulatory limits set forth by the respective regulations, i.e., 10 CFR 72 or 10 CFR 71.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MicrobesOnline: an integrated portal for comparative and functional genomics

Since 2003, MicrobesOnline (http://www.microbesonline.org) has been providing a community resource for comparative and functional genome analysis. The portal includes over 1000 complete genomes of bacteria, archaea and fungi and thousands of expression microarrays from diverse organisms ranging from model organisms such as Escherichia coli and Saccharomyces cerevisiae to environmental microbes such as Desulfovibrio vulgaris and Shewanella oneidensis. To assist in annotating genes and in reconstructing their evolutionary history, MicrobesOnline includes a comparative genome browser based on phylogenetic trees for every gene family as well as a species tree. To identify co-regulated genes, MicrobesOnline can search for genes based on their expression profile, and provides tools for identifying regulatory motifs and seeing if they are conserved. MicrobesOnline also includes fast phylogenetic profile searches, comparative views of metabolic pathways, operon predictions, a workbench for sequence analysis and integration with RegTransBase and other microbial genome resources. The next update of MicrobesOnline will contain significant new functionality, including comparative analysis of metagenomic sequence data. Programmatic access to the database, along with source code and documentation, is available at http://microbesonline.org/programmers.html.

59 BASIC BIOLOGICAL SCIENCES↗

MCNP Version 6.2 Release Notes

Monte Carlo N-Particle or MCNP ® is a general-purpose Monte Carlo radiation-transport code designed to track many particle types over broad ranges of energies. This MCNP Version 6.2 follows the MCNP6.1.1 beta version and has been released in order to provide the radiation transport community with the latest feature developments and bug fixes for MCNP. Since the last release of MCNP major work has been conducted to improve the code base, add features, and provide tools to facilitate ease of use of MCNP version 6.2 as well as the analysis of results. These release notes serve as a general guide for the new/improved physics, source, data, tallies, unstructured mesh, code enhancements and tools. For more detailed information on each of the topics, please refer to the appropriate references or the user manual which can be found at http://mcnp.lanl.gov. This release of MCNP version 6.2 contains 39 new features in addition to 172 bug fixes and code enhancements. There are still some 33 known issues the user should familiarize themselves with (see Appendix).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent Improvements To CINDER2008 and Activation Analysis Tools

CINDER2008 is a transmutation code that calculates induced radioactivity for either reactor- or accelerator-driven radiation sources. Several Perl scripts have been developed to treat multi-cell problems in combination with either the radiation transport code MCNPX or a special version of MCNPX that writes residual nuclide tallies from model-based physics directly in the MCNPX output file. These scripts simplify the preparation of CINDER input, and can use CINDER output to prepare the source term for a subsequent MCNPX run to calculate dose rates due to activated material. In addition, these scripts support calculations with the transmutation codes SP-FISPACT and ORIHET-3. A number of improvements have been made to CINDER, its data libraries, and the Perl scripts, including (1) substantial corrections to the data libraries, (2) inclusion of recent revisions to USDOE HC-2/HC-3 thresholds and the corresponding thresholds for regulatory bodies in other countries, (3) the ability to run the CINDER accident analysis tool through the script input file, and (4) an easier way to write the script input file when treating a large number of cells. Some features of running CINDER and a number of example problems are discussed.

Micklich, Bradley J.↗

Development, Testing and Validation of a Waste Assay System for the Measurement and Characterisation of Active Spent Fuel Element Debris From UK Magnox Reactors - 12533

This paper describes the development, testing and validation of a waste measurement instrument for characterising active remote handled radioactive waste arising from the operation of Magnox reactors in the United Kingdom. Following operation in UK Magnox gas cooled reactors and a subsequent period of cooling, parts of the magnesium-aluminium alloy cladding were removed from spent fuel and the uranium fuel rods with the remaining cladding were removed to Sellafield for treatment. The resultant Magnox based spent fuel element debris (FED), which constitutes active intermediate level waste (ILW) has been stored in concrete vaults at the reactor sites. As part of the decommissioning of the FED vaults the FED must be removed, measured and characterised and placed in intermediate storage containers. The present system was developed for use at the Trawsfynydd nuclear power station (NPS), which is in the decommissioning phase, but the approach is potentially applicable to FED characterisation at all of the Magnox reactors. The measurement system consists of a heavily shielded and collimated high purity Germanium (HPGe) detector with electromechanical cooling and a high count-rate preamplifier and digital multichannel pulse height analyser. The HPGe based detector system is controlled by a software code, which stores the measurement result and allows a comprehensive analysis of the measured FED data. Fuel element debris is removed from the vault and placed on a tray to a uniform depth of typically 10 cm for measurement. The tray is positioned approximately 1.2 meters above the detector which views the FED through a tungsten collimator with an inverted pyramid shape. At other Magnox sites the positions may be reversed with the shielded and collimated HPGe detector located above the tray on which the FED is measured. A comprehensive Monte Carlo modelling and analysis of the measurement process has been performed in order to optimise the measurement geometry and eliminate interferences from radioactive sources and FED in the immediate vicinity of the measurement position. The detector system has been calibrated and high activity radioactive sources of Cs-137, Co-60 and Na-22 have been used to validate the measurement process. The data acquisition and analysis software code has been tested and validated in keeping with the software quality assurance requirements of both ISO:9001-2008 - TICK-IT in the UK and NQA-1. The measurement and analysis system has been comprehensively tested with high activity sources, is flexible and may be applicable to a wide range of remote handled radioactive waste measurement applications. It is due to be installed at Trawsfynydd NPS later this year. This paper describes the Waste Tray Assay System (WTAS) that has been developed for the measurement of Magnox FED waste. The WTAS has been tested with a range of radioactive sources and its operation has been simulated with benchmarked MCNP Monte Carlo calculations. The measurement software has been validated as has the operation of the system for a range of strong radioactive sources. A system based on the design is due for installation and operation in 2012. The system has application to the measurement of Magnox Fuel Element Debris (FED) waste at other Magnox reactor sites. The major design objective of the WTAS that has been achieved is the ability of the assay system to determine the content of Cs-137, and in turn to enable the fissile burden to be assessed using a radionuclide fingerprint, in the presence of higher and highly variable quantities of Co-60, typically from nimonic springs. The approach can be used in other Magnox FED waste configurations where the detector is located above the FED waste sorting tray and where the collimation is fixed below the detector and at a distance above the tray. In this case, which has also been investigated, there are different shielding problems and mechanical support issues. The extensive use of MCNP Monte Carlo modelling to simulate the geometry of the sorting cell and the distribution of radioactive sources has helped to ensure that all of the detector shielding requirements are addressed and suitable Cs-137 and Co-60 discrimination can be achieved. The WTAS in its present form or in other configurations has relevance to the measurement of other active ILW and highly active RH waste. Examples include high activity RH LLW and RH TRU (Transuranic) waste as defined in the United States arising from both commercial nuclear and Department of Energy (DOE) operations. The analysis is able to analyse a range of radionuclides beyong those expected in the Magnox FED cases. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurement and analysis of GPU-accelerated applications with HPCToolkit

To address the challenge of performance analysis on the US DOE’s forthcoming exascale supercomputers, Rice University has been extending its HPCToolkit performance tools to support measurement and analysis of GPU-accelerated applications. To help developers understand the performance of accelerated applications as a whole, HPCToolkit’s measurement and analysis tools attribute metrics to calling contexts that span both CPUs and GPUs. To measure GPU-accelerated applications efficiently, HPCToolkit employs a novel wait-free data structure to coordinate monitoring and attribution of GPU performance. To help developers understand the performance of complex GPU code generated from high-level programming models, HPCToolkit constructs sophisticated approximations of call path profiles for GPU computations. To support fine-grained analysis and tuning, HPCToolkit uses PC sampling and instrumentation to measure and attribute GPU performance metrics to source lines, loops, and inlined code. To supplement fine-grained measurements, HPCToolkit can measure GPU kernel executions using hardware performance counters. To provide a view of how an execution evolves over time, HPCToolkit can collect, analyze, and visualize call path traces within and across nodes. Finally, on NVIDIA GPUs, HPCToolkit can derive and attribute a collection of useful performance metrics based on measurements using GPU PC samples. Here, we illustrate HPCToolkit’s new capabilities for analyzing GPU-accelerated applications with several codes developed as part of the Exascale Computing Project.

97 MATHEMATICS AND COMPUTING↗

An Uncertainty Analysis of the Hydrogen Source Term for a Station Blackout Accident in Sequoyah Using MELCOR 1.8.5

A methodology for using the MELCOR code with the Latin Hypercube Sampling method was developed to estimate uncertainty in various predicted quantities such as hydrogen generation or release of fission products under severe accident conditions. In this case, the emphasis was on estimating the range of hydrogen sources in station blackout conditions in the Sequoyah Ice Condenser plant, taking into account uncertainties in the modeled physics known to affect hydrogen generation. The method uses user-specified likelihood distributions for uncertain model parameters, which may include uncertainties of a stochastic nature, to produce a collection of code calculations, or realizations, characterizing the range of possible outcomes. Forty MELCOR code realizations of Sequoyah were conducted that included 10 uncertain parameters, producing a range of in-vessel hydrogen quantities. The range of total hydrogen produced was approximately 583kg ± 131kg. Sensitivity analyses revealed expected trends with respected to the parameters of greatest importance, however, considerable scatter in results when plotted against any of the uncertain parameters was observed, with no parameter manifesting dominant effects on hydrogen generation. It is concluded that, with respect to the physics parameters investigated, in order to further reduce predicted hydrogen uncertainty, it would be necessary to reduce all physics parameter uncertainties similarly, bearing in mind that some parameters are inherently uncertain within a range. It is suspected that some residual uncertainty associated with modeling complex, coupled and synergistic phenomena, is an inherent aspect of complex systems and cannot be reduced to point value estimates. The probabilistic analyses such as the one demonstrated in this work are important to properly characterize response of complex systems such as severe accident progression in nuclear power plants.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Refining HPCToolkit for application performance analysis at exascale

As part of the US Department of Energy’s Exascale Computing Project (ECP), Rice University has been refining its HPCToolkit performance tools to better support measurement and analysis of applications executing on exascale supercomputers. To efficiently collect performance measurements of GPU-accelerated applications, HPCToolkit employs novel non-blocking data structures to communicate performance measurements between tool threads and application threads. To attribute performance information in detail to source lines, loop nests, and inlined call chains, HPCToolkit performs parallel analysis of large CPU and GPU binaries involved in the execution of an exascale application to rapidly recover mappings between machine instructions and source code. To analyze terabytes of performance measurements gathered during executions at exascale, HPCToolkit employs distributed-memory parallelism, multithreading, sparse data structures, and out-of-core streaming analysis algorithms. To support interactive exploration of profiles up to terabytes in size, HPCToolkit’s hpcviewer graphical user interface uses out-of-core methods to visualize performance data. The result of these efforts is that HPCToolkit now supports collection, analysis, and presentation of profiles and traces of GPU-accelerated applications at exascale. These improvements have enabled HPCToolkit to efficiently measure, analyze and explore terabytes of performance data for executions using as many as 64K MPI ranks and 64K GPU tiles on ORNL’s Frontier supercomputer. HPCToolkit’s support for measurement and analysis of GPU-accelerated applications has been employed to study a collection of open-science applications developed as part of ECP. This paper reports on these experiences, which provided insight into opportunities for tuning applications, strengths and weaknesses of HPCToolkit itself, as well as unexpected behaviors in executions at exascale.

Adhianto, Laksono↗

As-Run ATR Physics Evaluation for the UCF-1 HSIS Experiment

This Engineering Calculations and Analysis Report (ECAR) documents the Advanced Test Reactor (ATR) detailed MCNP full core model physics analysis performed to support the irradiation of the University of Central Florida (UCF-1) Hydraulic Shuttle Irradiation System Experiment in the ATR B-7 position. The purpose of this analysis is to calculate: • The as-run neutron and gamma heating rates for the experiment components (W/g); • The as-run DPA for the experiment specimens after 20 (test train 1) and 2 (test train 2) days of irradiation in the ATR B-7 position (neutrons/cm2-sec); • The radionuclide source term after 2 days and 20 days of irradiation in the ATR B-7 position; • The decay heat associated with the UCF-1 radionuclide source term. These calculations were performed using the computer codes MCNP and ORIGEN2. The neutronics model, analysis details, and results are presented in the attached report.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of 3-panel and 4-panel microscale ionization sources

Two designs of a microscale electron ionization (EI) source are analyzed herein: a 3-panel design and a 4-panel design. Devices were fabricated using microelectromechanical systems technology. Field emission from carbon nanotube provided the electrons for the EI source. Ion currents were measured for helium, nitrogen, and xenon at pressures ranging from 10{sup -4} to 0.1 Torr. A comparison of the performance of both designs is presented. The 4-panel microion source showed a 10x improvement in performance compared to the 3-panel device. An analysis of the various factors affecting the performance of the microion sources is also presented. SIMION, an electron and ion optics software, was coupled with experimental measurements to analyze the ion current results. The electron current contributing to ionization and the ion collection efficiency are believed to be the primary factors responsible for the higher efficiency of the 4-panel microion source. Other improvements in device design that could lead to higher ion source efficiency in the future are also discussed. These microscale ion sources are expected to find application as stand alone ion sources as well as in miniature mass spectrometers.

07 ISOTOPE AND RADIATION SOURCES↗

Heavy Metal Atmospheric Deposition Study in Moscow Region, Russia

The air quality in north-eastern part of Moscow region was evaluated by trace metals atmospheric deposition using moss Pleurozium schreberi as bioindicator. Thirty six elements were determined in analyzed samples by Neutron activation analysis and Atomic absorption spectrometry. Principal component analysis was used to identify and characterize different pollution sources. Maps showing the geographical distribution of the factor scores were built using ArcGis software. Median values of the elements studied were compared with data obtained for other regions in Russia. The present survey showed that industrial activity, thermal power plants and transport still have the largest anthropogenic impact on air pollution in studied region.

54 ENVIRONMENTAL SCIENCES↗

Validation and uncertainty quantification of detector response functions for a $1"×2"$ NaI collimated detector intended for inverse radioisotope source mapping applications

Detector response functions (DRFs) are often used for inverse analysis. We compute the DRF of a sodium iodide (NaI) nuclear material holdup field detector using the code named g03 developed by the Center for Engineering Applications of Radioisotopes (CEAR) at NC State University. Three measurement campaigns were performed in order to validate the DRF’s constructed by g03: on-axis detection of calibration sources, off-axis measurements of a highly enriched uranium (HEU) disk, and on-axis measurements of the HEU disk with steel plates inserted between the source and the detector to provide attenuation. Furthermore, this work quantifies the uncertainty of the Monte Carlo simulations used in and with g03, as well as the uncertainties associated with each semi-empirical model employed in the full DRF representation. Overall, for the calibration source measurements, the response computed by the DRF for the prediction of the full-energy peak region of responses was good, i.e. within two standard deviations of the experimental response. In contrast, the DRF tended to overestimate the Compton continuum by about 45–65% due to inadequate tuning of the electron range multiplier fit variable that empirically represents physics associated with electron transport that is not modeled explicitly in g03. For the HEU disk measurements, computed DRF responses tended to significantly underestimate (more than 20%) the secondary full-energy peaks (any peak of lower energy than the highest-energy peak computed) due to scattering in the detector collimator and aluminum can, which is not included in the g03 model. We ran a sufficiently large number of histories to ensure for all of the Monte Carlo simulations that the statistical uncertainties were lower than their experimental counterpart’s Poisson uncertainties. The uncertainties associated with least-squares fits to the experimental data tended to have parameter relative standard deviations lower than the peak channel relative standard deviation in most cases and good reduced chi-square values. The highest sources of uncertainty were identified as the energy calibration polynomial factor (due to limited source availability and NaI resolution) and the Ba-133 peak fit (only a very weak source was available), which were 20% and 10%, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Background gas density and beam losses in NIO1 beam source

NIO1 (Negative Ion Optimization 1) is a versatile ion source designed to study the physics of production and acceleration of H- beams up to 60 keV. In ion sources, the gas is steadily injected in the plasma source to sustain the discharge, while high vacuum is maintained by a dedicated pumping system located in the vessel. In this paper, the three dimensional gas flow in NIO1 is studied in the molecular flow regime by the Avocado code. The analysis of the gas density profile along the accelerator considers the influence of effective gas temperature in the source, of the gas temperature accommodation by collisions at walls, and of the gas particle mass. The calculated source and vessel pressures are compared with experimental measurements in NIO1 during steady gas injection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft x-ray scattering facility at the Advanced Light Source with real-time data processing and analysis

We present the development and characterization of a dedicated resonant soft x-ray scattering facility. Capable of operation over a wide energy range, the beamline and endstation are primarily used for scattering from soft matter systems around the carbon K-edge ({approx}285 eV). We describe the specialized design of the instrument and characteristics of the beamline. Operational characteristics of immediate interest to users such as polarization control, degree of higher harmonic spectral contamination, and detector noise are delineated. Of special interest is the development of a higher harmonic rejection system that improves the spectral purity of the x-ray beam. Special software and a user-friendly interface have been implemented to allow real-time data processing and preliminary data analysis simultaneous with data acquisition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EC Transmission Line Materials

The purpose of this document is to identify materials acceptable for use in the US ITER Project Office (USIPO)-supplied components for the ITER Electron cyclotron Heating and Current Drive (ECH&CD) transmission lines (TL), PBS-52. The source of material property information for design analysis shall be either the applicable structural code or the ITER Material Properties Handbook. In the case of conflict, the ITER Material Properties Handbook shall take precedence. Materials selection, and use, shall follow the guidelines established in the Materials Assessment Report (MAR). Materials exposed to vacuum shall conform to the ITER Vacuum Handbook. [Ref. 2] Commercial materials shall conform to the applicable standard (e.g., ASTM, JIS, DIN) for the definition of their grade, physical, chemical and electrical properties and related testing. All materials for which a suitable certification from the supplier is not available shall be tested to determine the relevant properties, as part of the procurement. A complete traceability of all the materials including welding materials shall be provided. Halogenated materials (example: insulating materials) shall be forbidden in areas served by the detritiation systems. Exceptions must be approved by the Tritium System and Safety Section Responsible Officers.

24 POWER TRANSMISSION AND DISTRIBUTION↗