Search NASA⌕ Search

SEARCH · Search NASA

Results for “Source characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Multi-INT Signature Collection and Exploitation for Security Los Alamos LDRD Report

This project demonstrates the feasibility of a 2-D passive tracking capability for ground-based and airborne moving sources using multi-INT signal processing of acoustic and seismic signals. We leveraged the recent DDSTE-supported investment in rapid deployable sensors (the Los Alamos Rapid-deployable Sensor Array—LARSA), and used uncrewed aerial vehicles (UAV) as a data source. Moving source types are characterized by their variability with time (exemplified but not limited to the Doppler shift of a passing vehicle) and the signatures used for detection should have similar characteristics. We have demonstrated that time-varying sensor signatures (TVS) combined with time-stable sensor signatures provide a more complete understanding of moving source behavior and drive towards path prediction. Importantly, we have collected a new, relevant LANL dataset of moving sources (small UAV flights and vehicle movement), developed new signatures, and demonstrated a capability to identify, track and forecast the position of TVS.

42 ENGINEERING↗

Analysis of Long-Term Quality Control Data for a 137 Cs Dosimetry Calibration Source

Strict quality assurance programs are required for many radiological applications, but these seldom exist for verifying dosimetry calibration sources. After initial characterization of a dosimetry calibration facility, quality control procedures are recommended to ensure the early detection of any changes or malfunctions. These also result in refined knowledge about average dose rate and experimental variations in dose delivery. This paper describes the implementation of a phase I quality control protocol for a 137 Cs dosimetry calibration source and includes an analysis of the resulting data collected over a 24-mo period. During this time, substantial data was collected to establish trial control limits. Air kerma rate measurements were obtained using an ion chamber and were adjusted for decay, corrected for ambient temperature, pressure and humidity, and then analyzed using quality control charts. Three variations of rational subgrouping methods were used in order to find assignable causes of error, and Nelson's Rules were followed to detect any non-random statistical variations. Measurements were subgrouped according to same-day measurements in order to detect positional errors as well as atmospheric correction errors. Additionally, measurements were subgrouped according to analogous experimental setups in order to detect failure in equipment or incorrect settings. Both were analyzed using the X-bar and R chart method. Similarly, individuals and moving ranges charts were used to carefully examine each position in order to observe any situational errors that may occur which include timing, positional, or interference errors. Each method was successful in identifying unique out-of-control data points that occurred during the phase I application of forming control limits. Furthermore, over the 24-mo period, enough data points were deemed in-control to establish reliable trial limits. Future experiments will include the phase II application of gaining more reliable measurements in order to fine-tune the limits, as well as performing a designed experiment, where variables are purposefully changed in order to test the variation of the data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multi-INT Signature Collection and Exploitation for Security: Improving Discrimination, Analyses, and Passive Tracking Capabilities for Time- and Distance-Varying Signatures in the Seismoacoustic Regime

This project demonstrates the feasibility of a passive tracking capability for ground-based and airborne moving sources using multiple information streams from acoustic and seismic signals. These moving source types are characterized by their variability with time and distance (exemplified but not limited to the familiar doppler shift of a passing vehicle) and the signatures used for detection should have similar characteristics. We have demonstrated that time-varying sensor signatures (TVS) combined with time-stable sensor signatures provide a more complete understanding of moving source behavior. Importantly, we have collected a new, relevant LANL dataset of moving sources (small uncrewed aerial vehicle flights and ground vehicle movement), developed new signatures, and demonstrated the capability to identify, track and forecast the position of these moving sources.

42 ENGINEERING↗

Statistical and systematic uncertainties in extracting the source properties of neutron star-black hole binaries with gravitational waves

Gravitational waves emitted by neutron star black hole mergers encode key properties of neutron stars - such as their size, maximum mass and spins - and black holes. However, the presence of matter and the high mass ratio makes generating long and accurate waveforms from these systems hard to do with numerical relativity, and not much is known about systematic uncertainties due to waveform modeling. In this work, we simulate gravitational waves from neutron star black hole mergers by hybridizing numerical relativity waveforms produced with the SpEC code with a recent numerical relativity surrogate NRHybSur3dq8Tidal. These signals are analyzed using a range of available waveform families, and statistical and systematic errors are reported. We find that at a network signal-to-noise ratio (SNR) of 30, statistical uncertainties are usually larger than systematic offsets, while at an SNR of 70 the two become comparable. The individual black hole and neutron star masses, as well as the mass ratios, are typically measured very precisely, though not always accurately at high SNR. At a SNR of 30 the neutron star tidal deformability can only be bound from above, while for louder sources it can be measured and constrained away from zero. All neutron stars in our simulations are non-spinning, but in no case we can constrain the neutron star spin to be smaller than ~0.4 (90% credible interval). Waveform families whose late inspiral has been tuned specifically for neutron star black hole signals typically yield the most accurate characterization of the source parameters. Their measurements are in tension with those obtained using waveform families tuned against binary neutron stars, even for mass ratios that could be relevant for both binary neutron stars and neutron star black holes mergers.

79 ASTRONOMY AND ASTROPHYSICS↗

A digital holography ex situ measurement characterization of plasma-exposed surface erosion from an electrothermal arc source

Digital holography has been proposed to fulfill a need for an imaging diagnostic capable of in situ monitoring of surface erosion caused by plasma–material interaction in nuclear fusion devices. A digital holography diagnostic for 3D surface erosion measurement has been developed at Oak Ridge National Laboratory with the goal of deployment on a plasma device. A proof-of-concept in situ demonstration is planned which would involve measurement of plasma erosion on targets exposed to an electrothermal arc source. This work presents the results of an ex situ characterization of the capability and limitations of holographic imaging of targets exposed to the arc source. Targets were designed to provide a fiducial for comparison of deformed and unaffected areas. The results indicated that the average net erosion was ~150 nm/plasma exposure, which is expected to be within the diagnostic’s measurement capacity. Surface roughness averages determined by holographic image analysis showed good agreement with measurements taken with a profilometer. Finally, the limit of the holography diagnostic’s x–y spatial resolution was characterized by comparison with scanning electron microscope imaging.

47 OTHER INSTRUMENTATION↗

Real-time mixed reality display of dual particle radiation detector data

Radiation source localization and characterization are challenging tasks that currently require complex analyses for interpretation. Mixed reality (MR) technologies are at the verge of wide scale adoption and can assist in the visualization of complex data. Herein, we demonstrate real-time visualization of gamma ray and neutron radiation detector data in MR using the Microsoft HoloLens 2 smart glasses, significantly reducing user interpretation burden. Radiation imaging systems typically use double-scatter events of gamma rays or fast neutrons to reconstruct the incidence directional information, thus enabling source localization. The calculated images and estimated ’hot spots’ are then often displayed in 2D angular space projections on screens. By combining a state-of-the-art dual particle imaging system with HoloLens 2, we propose to display the data directly to the user via the head-mounted MR smart glasses, presenting the directional information as an overlay to the user’s 3D visual experience. We describe an open source implementation using efficient data transfer, image calculation, and 3D engine. We thereby demonstrate for the first time a real-time user experience to display fast neutron or gamma ray images from various radioactive sources set around the detector. We also introduce an alternative source search mode for situations of low event rates using a neural network and simulation based training data to provide a fast estimation of the source’s angular direction. Using MR for radiation detection provides a more intuitive perception of radioactivity and can be applied in routine radiation monitoring, education & training, emergency scenarios, or inspections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photoemission characterization of N-polar III-nitride photocathodes as candidate bright electron beam sources for accelerator applications

We report on the growth and characterization of a new class of photocathode structures for use as electron sources to produce high brightness electron beams for accelerator applications. The sources are realized using III-nitride materials and are designed to leverage the strong polarization field, which is characteristic of this class of materials when grown in their wurtzite crystal structure, to produce a negative electron affinity condition without the use of Cs, possibly allowing these materials to be operated in radio frequency guns. A Quantum Efficiency (QE) of about 1×10−3 and an emitted electrons’ Mean Transverse Energy (MTE) of about 100 meV are measured at a wavelength of 265 nm. In a vacuum level of 3×10−10 Torr, the QE does not decrease after more than 24 h of continuous operation. The lowest MTE of about 50 meV is measured at 300 nm along with a QE of 1.5×10−5. Surface characterizations reveal a possible contribution to the MTE from surface morphology, calling for more detailed studies.

Cultrera, L. (ORCID:0000000235606059)↗

Simultaneous bright- and dark-field X-ray microscopy at X-ray free electron lasers

Abstract The structures, strain fields, and defect distributions in solid materials underlie the mechanical and physical properties across numerous applications. Many modern microstructural microscopy tools characterize crystal grains, domains and defects required to map lattice distortions or deformation, but are limited to studies of the (near) surface. Generally speaking, such tools cannot probe the structural dynamics in a way that is representative of bulk behavior. Synchrotron X-ray diffraction based imaging has long mapped the deeply embedded structural elements, and with enhanced resolution, dark field X-ray microscopy (DFXM) can now map those features with the requisite nm-resolution. However, these techniques still suffer from the required integration times due to limitations from the source and optics. This work extends DFXM to X-ray free electron lasers, showing how the $$10^{12}$$ 10 12 photons per pulse available at these sources offer structural characterization down to 100 fs resolution (orders of magnitude faster than current synchrotron images). We introduce the XFEL DFXM setup with simultaneous bright field microscopy to probe density changes within the same volume. This work presents a comprehensive guide to the multi-modal ultrafast high-resolution X-ray microscope that we constructed and tested at two XFELs, and shows initial data demonstrating two timing strategies to study associated reversible or irreversible lattice dynamics.

47 OTHER INSTRUMENTATION↗

SYMBA: An end-to-end VLBI synthetic data generation pipeline

Realistic synthetic observations of theoretical source models are essential for our understanding of real observational data. In using synthetic data, one can verify the extent to which source parameters can be recovered and evaluate how various data corruption effects can be calibrated. These studies are the most important when proposing observations of new sources, in the characterization of the capabilities of new or upgraded instruments, and when verifying model-based theoretical predictions in a direct comparison with observational data. We present the SYnthetic Measurement creator for long Baseline Arrays (SYMBA), a novel synthetic data generation pipeline for Very Long Baseline Interferometry (VLBI) observations. SYMBA takes into account several realistic atmospheric, instrumental, and calibration effects. Here, we used SYMBA to create synthetic observations for the Event Horizon Telescope (EHT), a millimetre VLBI array, which has recently captured the first image of a black hole shadow. After testing SYMBA with simple source and corruption models, we study the importance of including all corruption and calibration effects, compared to the addition of thermal noise only. Using synthetic data based on two example general relativistic magnetohydrodynamics (GRMHD) model images of M 87, we performed case studies to assess the image quality that can be obtained with the current and future EHT array for different weather conditions. Our synthetic observations show that the effects of atmospheric and instrumental corruptions on the measured visibilities are significant. Despite these effects, we demonstrate how the overall structure of our GRMHD source models can be recovered robustly with the EHT2017 array after performing calibration steps, which include fringe fitting, a priori amplitude and network calibration, and self-calibration. With the planned addition of new stations to the EHT array in the coming years, images could be reconstructed with higher angular resolution and dynamic range. In our case study, these improvements allowed for a distinction between a thermal and a non-thermal GRMHD model based on salient features in reconstructed images.

79 ASTRONOMY AND ASTROPHYSICS↗

2D-to-3D image translation of complex nanoporous volumes using generative networks

Image-based characterization offers a powerful approach to studying geological porous media at the nanoscale and images are critical to understanding reactive transport mechanisms in reservoirs relevant to energy and sustainability technologies such as carbon sequestration, subsurface hydrogen storage, and natural gas recovery. Nanoimaging presents a trade off, however, between higher-contrast sample-destructive and lower-contrast sample-preserving imaging modalities. Furthermore, high-contrast imaging modalities often acquire only 2D images, while 3D volumes are needed to characterize fully a source rock sample. In this work, we present deep learning image translation models to predict high-contrast focused ion beam-scanning electron microscopy (FIB-SEM) image volumes from transmission X-ray microscopy (TXM) images when only 2D paired training data is available. We introduce a regularization method for improving 3D volume generation from 2D-to-2D deep learning image models and apply this approach to translate 3D TXM volumes to FIB-SEM fidelity. We then segment a predicted FIB-SEM volume into a flow simulation domain and calculate the sample apparent permeability using a lattice Boltzmann method (LBM) technique. Results show that our image translation approach produces simulation domains suitable for flow visualization and allows for accurate characterization of petrophysical properties from non-destructive imaging data.

58 GEOSCIENCES↗

Dwarf AGNs from Optical Variability for the Origins of Seeds (DAVOS): insights from the dark energy survey deep fields

ABSTRACT We present a sample of 706, z < 1.5 active galactic nuclei (AGNs) selected from optical photometric variability in three of the Dark Energy Survey (DES) deep fields (E2, C3, and X3) over an area of 4.64 deg2. We construct light curves using difference imaging aperture photometry for resolved sources and non-difference imaging PSF photometry for unresolved sources, respectively, and characterize the variability significance. Our DES light curves have a mean cadence of 7 d, a 6-yr baseline, and a single-epoch imaging depth of up to g ∼ 24.5. Using spectral energy distribution (SED) fitting, we find 26 out of total 706 variable galaxies are consistent with dwarf galaxies with a reliable stellar mass estimate ($M_{\ast }\lt 10^{9.5}\, {\rm M}_\odot$; median photometric redshift of 0.9). We were able to constrain rapid characteristic variability time-scales (∼ weeks) using the DES light curves in 15 dwarf AGN candidates (a subset of our variable AGN candidates) at a median photometric redshift of 0.4. This rapid variability is consistent with their low black hole (BH) masses. We confirm the low-mass AGN nature of one source with a high S/N optical spectrum. We publish our catalogue, optical light curves, and supplementary data, such as X-ray properties and optical spectra, when available. We measure a variable AGN fraction versus stellar mass and compare to results from a forward model. This work demonstrates the feasibility of optical variability to identify AGNs with lower BH masses in deep fields, which may be more ‘pristine’ analogues of supermassive BH seeds.

79 ASTRONOMY AND ASTROPHYSICS↗

Electron-nuclear decoupling at a spin clock transition

The ability to design quantum systems that decouple from environmental noise sources is highly desirable for development of quantum technologies with optimal coherence. The chemical tunability of electronic states in magnetic molecules combined with advanced electron spin resonance techniques provides excellent opportunities to address this problem. Indeed, so-called clock transitions have been shown to protect molecular spin qubits from magnetic noise, giving rise to significantly enhanced coherence. Here we conduct a spectroscopic and computational investigation of this physics, focusing on the role of the nuclear bath. Away from the clock transition, linear coupling to the nuclear degrees of freedom causes a modulation and decay of electronic coherence, as quantified via electron spin echo signals generated experimentally and in silico. Meanwhile, the effective hyperfine interaction vanishes at the clock transition, resulting in electron-nuclear decoupling and an absence of quantum information leakage to the nuclear bath, providing opportunities to characterize other decoherence sources.

74 ATOMIC AND MOLECULAR PHYSICS↗

Characterization of 128 × 128 MM-PAD-2.1 ASIC: a fast framing hard x-ray detector with high dynamic range

Here, we characterize a new x-ray Mixed-Mode Pixel Array Detector (MM-PAD-2.1) Application Specific Integrated Circuit (ASIC). Using an integrating pixel front-end with dynamic charge removal architecture, the MM-PAD-2.1 ASIC extends the maximum measurable x-ray signal (in 20 keV photon units) to > 10 7 x-rays/pixel/frame while maintaining a low read noise across the full dynamic range, all while imaging continuously at a frame rate of up to 10 kHz. The in-pixel dynamic charge removal mechanism prevents saturation of the input amplifier and proceeds in parallel with signal integration to achieve deadtime-less measurements with incident x-ray rates of > 10 10 x-rays/pixel/s. The ASIC format consists of 128 × 128 square pixels each 150 μm on a side and is designed to be 3-side buttable so large arrays can be effectively tiled. Here we use both laboratory x-ray sources and the Cornell High Energy Synchrotron Source (CHESS) to characterize two single ASIC prototype detectors for both low (single x-ray) and high incident flux detection. In the first detector the ASIC was solder bump-bonded to a 500 μm thick Si sensor for efficient detection of x-rays below 20 keV, whereas the second detector used a 750 μm thick CdTe sensor for x-rays above ~20 keV.

36 MATERIALS SCIENCE↗

Stimulated emission tomography for efficient characterization of spatial entanglement

Stimulated-emission tomography (SET) is an excellent tool for characterizing the process of spontaneous parametric down conversion (SPDC), which is commonly used to create pairs of entangled photons for use in quantum information protocols. The use of stimulated emission increases the average number of detected photons by several orders of magnitude compared to the spontaneous process. In a SET measurement, the parametric down conversion is seeded by an intense signal field prepared with specified mode properties rather than by broadband multimodal vacuum fluctuations, as is the case for the spontaneous process. The SET process generates an intense idler field in a mode that is the complex conjugate to the signal mode. In this work we use SET to estimate the joint spatial mode distribution (JSMD) in the Laguerre-Gaussian (LG) basis of the two photons of an entangled photon pair. The pair is produced by parametric down conversion in a beta barium borate (BBO) crystal with type-II phase matching pumped at a wavelength of 405 nm along with a 780 nm seed signal beam prepared in a variety of LG modes to generate an 842 nm idler beam of which the spatial mode distribution is measured. We observe strong idler production and good agreement with the theoretical prediction of its spatial mode distribution. Our experimental procedure should enable the efficient determination of the photon-pair wavefunctions produced by low-brightness SPDC sources and the characterization of high-dimensional entangled-photon pairs. Published by the American Physical Society 2024

Xu, Yang (ORCID:0009000954547320)↗

Advancing Sodium-Ion Battery Cathodes: A Low-Cost, Eco-Friendly Mechanofusion Route from TiO 2 Coating to Ti 4+ Doping

Layered oxide battery cathodes often require extra stabilization strategies, such as surface coating or doping, to mitigate side reactions and enhance longevity. Conventional methods such as aqueous deposition and atomic layer deposition are costly and environmentally unfriendly and even damage the original structure, especially for air-sensitive sodium-ion battery (SIB) cathodes. Herein, we introduce an all-dry mechanofusion technique that modifies hydroxide precursors with TiO 2 coating before sintering with a sodium source. Using advanced characterizations including X-ray diffraction, neutron diffraction, and solid-state nuclear magnetic resonance for structural insights, X-ray absorption spectroscopy to study metal valence states, and transmission X-ray microscopy for nanoscale visualization of nickel oxidation states, we verified that postsintering transforms TiO 2 surface coating into Ti doping, leading to improved Ni-oxidation homogeneity, modified charge compensation, and enhanced thermal stability. Electrochemical tests reveal superior performance in capacity retention, rate capability, and air stability for these modified cathodes, with pouch cells maintaining over 85% capacity after 650 cycles. This method presents a sustainable, cost-effective route for advanced SIB cathode development.

36 MATERIALS SCIENCE↗

A Vector Sensor-Based Acoustic Characterization System for Marine Renewable Energy

NoiseSpotter is a passive acoustic monitoring system that characterizes, classifies, and geo-locates anthropogenic and natural sounds in near real time. It was developed with the primary goal of supporting the evaluation of potential acoustic effects of offshore renewable energy projects. The system consists of a compact array of three acoustic vector sensors, which measures acoustic pressure and the three-dimensional particle velocity vector associated with the propagation of an acoustic wave, thereby inherently providing bearing information to an underwater source of sound. By utilizing an array of three vector sensors, the application of beamforming techniques can provide sound source localization, allowing for characterization of the acoustic signature of specific underwater acoustic sources. Here, performance characteristics of the system are presented, using data from controlled acoustic transmissions in a quiet environment and ambient noise measurements in an energetic tidal channel in the presence of non-acoustic flow noise. Data quality is demonstrated by the ability to reduce non-acoustic flow noise contamination, while system utility is shown by the ability to characterize and localize sources of sound in the underwater environment.

16 TIDAL AND WAVE POWER↗

Evaluation of methods for characterizing the fine particulate matter emissions from aircraft and other diffusion flame combustion aerosol sources

The U. S. Environmental Protection Agency in collaboration with the U. S. Air Force Arnold Engineering Development Complex conducted the VAriable Response In Aircraft nvPM Testing (VARIAnT) 3 and 4 test campaigns to compare nvPM emissions measurements from a variety of diffusion flame combustion aerosol sources (DFCASs), including a Cummins diesel engine, a diesel powered generator, two gas turbine start carts, a J85-GE-5 turbojet engine burning multiple fuels, and a Mini-CAST soot generator. The VARIAnT research program has conducted four test campaigns to date with the VARIAnT 3 and 4 test campaigns focusing on BC mass instrument performance, use of gas turbine engine sources for BC mass instrument calibration, and the characterization of the aerosols produced from the combustion sources. Results from both campaigns revealed agreement of about 20% between the AVL Micro-Soot Sensor, the Cavity Attenuated Phase Shift (CAPS PMSSA) monitor and the thermal-optical reference method for elemental carbon (EC), independent of the calibration source used. For the Artium LII-300, the measured mass concentrations in VARIAnT3 fall within 18% and in VARIAnT4 fall within 32% of the reference EC mass concentration when calibrated on a combustor rig in VARIAnT3 and on a LGT-60 start cart in VARIAnT4, respectively. It was also found that the three mass instrument types (MSS, CAPS PMSSA, and LII-300) can exhibit different BC to reference EC ratios depending on the emission source that appear to correlate to particle geometric mean mobility diameter, morphology, or some other parameter associated with particle geometric mean diameter (GMD) with the LII-300 showing a slightly stronger apparent trend with GMD. Systematic differences in LII-300 measured mass concentrations have been reduced by calibrating with a turbine combustion source (combustor or turbine engine). With respect to the particle size measurements made, the sizing instruments (TSI SMPS, TSI EEPS, and Cambustion DMS 500) were found to be in general agreement in terms of size distributions and concentrations with some exceptions. Teflon filter measurements of the total aerosol mass produced by the various DFCASs differed from the reference EC, BC, and integrated particle sized distribution measured aerosol masses. The Teflon filter measured mass was 30 to 40% greater than the reference EC and 50 to 60% greater than the BC mass for the J85 in both test campaigns. The measurements of particle size distributions and single particle analysis by miniSPLAT indicated the presence of large particles (>100 nm) having more compact morphologies, higher effective density, and a composition dominated by OC and ash. This increased large particle fraction is also associated with higher values of single scattering albedo measured by the CAPS PMSSA instrument and higher OC/EC measurements. These measurements indicate gas turbine engine emissions can be a more heterogeneous mix of particle types beyond the original E31 assumption that it is mainly composed of black carbon.

33 ADVANCED PROPULSION SYSTEMS↗

Repeatability and sensitivity characterization of the far-field high-energy diffraction microscopy instrument at the Advanced Photon Source

In the last two decades, far-field high-energy diffraction microscopy (FF-HEDM) and similar non-destructive techniques have been actively developed at synchrotron light sources around the world. As these techniques (and associated analysis tools) are becoming more available for the general users of these light sources, it is important and timely to characterize their performance and capabilities. In this work, the FF-HEDM instrument implemented at the 1-ID-E endstation of the Advanced Photon Source (APS) is summarized. The set of measurements conducted to characterize the instrument's repeatability and sensitivity to changes in grain orientation and position are also described. When an appropriate grain matching method is used, the FF-HEDM instrument's repeatability is approximately 5 µm in translation, 0.02° in rotation, and 2 × 10 −4 in strain; the instrument sensitivity is approximately 5 µm in translation and 0.05° in rotation.

3DXRD↗