At least 181 records · Page 10

Measurement of Energy Reduction of Inertial Alfvén Waves Propagating through Parallel Gradients in the Alfvén Speed

We have studied the propagation of inertial Alfvén waves through parallel gradients in the Alfvén speed using the Large Plasma Device at the University of California, Los Angeles. The reflection and transmission of Alfvén waves through inhomogeneities in the background plasma are important for understanding wave propagation, turbulence, and heating in space, laboratory, and astrophysical plasmas. Here we present inertial Alfvén waves under conditions relevant to solar flares and the solar corona. We find that the transmission of the inertial Alfvén waves is reduced as the sharpness of the gradient is increased. Any reflected waves were below the detection limit of our experiment, and reflection cannot account for all of the energy not transmitted through the gradient. Our findings indicate that, for both kinetic and inertial Alfvén waves, the controlling parameter for the transmission of the waves through an Alfvén speed gradient is the ratio of the Alfvén wavelength along the gradient divided by the scale length of the gradient. Furthermore, our results suggest that an as-yet-unidentified damping process occurs in the gradient.

79 ASTRONOMY AND ASTROPHYSICS↗

Adsorption system

An adsorption system can be used as part of a climate control system in a vehicle or in any other space requiring heating or cooling. The adsorbent system can include an enclosure, a plurality of layers arranged in a stack inside the enclosure, and a vapor channel inside the enclosure.

Wang, Evelyn N.↗

Design and performance assessment of a dual-mode latent thermal storage integrated heat pump across multiple climate zones

The electrification of space cooling and heating systems risks overloading the existing electrical grid during peak hours. Heat pumps integrated with thermal energy storage (HP-TES) offer a promising solution by shifting peak loads to off-peak hours, reducing grid strains. This work presents the design and assessment of a dual-mode HP-TES that uses a single 22°C phase-change material (PCM) as a heat source or sink in heating and cooling modes, respectively. Performance assessment was conducted using Modelica-based transient models, and full-year simulations were conducted across eight US climate zones using typical weather data. Two HP-TES performance metrics: peak energy reduction and recharge energy increases, were defined by comparing HP-TES energy consumption with base HP peak consumptions. Annual heating demand reductions (40–65%) exceeded cooling demand reductions (15–20%) due to the elimination of peak-hour backup heating. Cooling mode recharge energy requirements (0–10%) were reduced in locations with lower summer nighttime temperatures, while heating recharge requirements were lower than the high base-peak energy demand from backup heating. Simplified rapid methods that were 10 7 times faster than annual simulations were developed to predict seasonal cooling and heating energy reductions, and recharge energy requirements, with maximum deviations of ±2.5% and ±3.5% points. These methods enabled rapid parametric studies that identified optimal location-specific PCM temperatures between 22°C and 27°C, highlighting the need to consider both discharge and recharge energy requirements to achieve sustainable, energy-efficient peak load shifting across various climate zones.

25 ENERGY STORAGE↗

Electrochemically driven phase transformation for high-efficiency heat pumping

To reduce energy consumption and improve energy utilization in space conditioning, advanced heat pumping technologies are needed. The chemical looping heat pump (CLHP) is a promising thermodynamic cycle that has theoretically shown the potential to achieve a cooling coefficient of performance (COP c ) increase of over 20% relative to conventional vapor compression systems. In this paper, the key process of the CLHP is experimentally demonstrated, and the system performance and non-ideal behavior are predicted using the component-level models. The results show the feasibility of electrochemical phase change of a working fluid; the peak COP c was 7.64 with a cooling capacity of 3.6 mW (cooling density of 2.57 W m -2 ) at both sink and source temperature of 23°C based on laboratory experiments. The COP c can theoretically reach up to 13 at a temperature lift of 15°C as long as an electrochemical cell can achieve a greater degree of conversion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phase-space entropy cascade and irreversibility of stochastic heating in nearly collisionless plasma turbulence

We consider a nearly collisionless plasma consisting of a species of “test particles” in one spatial and one velocity dimension, stirred by an externally imposed stochastic electric field—a kinetic analog of the Kraichnan model of passive advection. The mean effect on the particle distribution function is turbulent diffusion in velocity space—known as stochastic heating. Accompanying this heating is the generation of fine-scale structure in the distribution function, which we characterize with the collisionless (Casimir) invariant C 2 ∝ ∫ ∫ d x d v 〈 f 2 〉 —a quantity that here plays the role of (negative) entropy of the distribution function. We find that C 2 is transferred from large scales to small scales in both position and velocity space via a phase-space cascade enabled by both particle streaming and nonlinear interactions between particles and the stochastic electric field. We compute the steady-state fluxes and spectrum of C 2 in Fourier space, with k and s denoting spatial and velocity wave numbers, respectively. In our model, the nonlinearity in the evolution equation for the spectrum turns into a fractional Laplacian operator in k space, leading to anomalous diffusion. Whereas even the linear phase mixing alone would lead to a constant flux of C 2 to high s (towards the collisional dissipation range) at every k , the nonlinearity accelerates this cascade by intertwining velocity and position space so that the flux of C 2 is to both high k and high s simultaneously. Integrating over velocity (spatial) wave numbers, the k -space ( s -space) flux of C 2 is constant down to a dissipation length (velocity) scale that tends to zero as the collision frequency does, even though the rate of collisional dissipation remains finite. The resulting spectrum in the inertial range is a self-similar function in the ( k , s ) plane, with power-law asymptotics at large k and s . Our model is fully analytically solvable, but the asymptotic scalings of the spectrum can also be found via a simple phenomenological theory whose key assumption is that the cascade is governed by a “critical balance” in phase space between the linear and nonlinear timescales. We argue that stochastic heating is made irreversible by this entropy cascade and that, while collisional dissipation accessed via phase mixing occurs only at small spatial scales rather than at every scale as it would in a linear system, the cascade makes phase mixing even more effective overall in the nonlinear regime than in the linear one. Published by the American Physical Society 2024

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Heat Pumps with Phase Change Thermal Storage: Flexible, Efficient, and Electrification Friendly

As we continue to electrify space- and water-heating, the electricity demand profile of many buildings will change significantly, and periods of high electricity demand will likely not align with renewable energy generation. We expect electricity demands will increase substantially in the winter, annual maximum electricity demands will increase, and more regions will experience annual peak electrical demands – and higher wholesale electricity prices – in the winter. This is especially important for cold climates where 60% of site energy use in buildings is for heating, and where heat pumps perform least efficiently. This paper focuses on one promising solution among the many paths to electrification: the use of phase change materials (PCM) for compact low-cost thermal energy storage (TES). We present the design and simulation of a combi heat pump and phase change thermal storage system used for space- and water-heating in a multifamily residence in a cold climate. To assess the benefits of this technology, we compare its annual performance to that of a current state-of-the-art air-to-air heat pump and separate heat pump water heater. Simulation results for IECC Climate Zone 6A reveal that the combi heat pump with phase change thermal storage can reduce the design size for heat pumps by 40-60%, reduce maximum electric demand by 30-50%, reduce electricity use during 4-12-hour load shed periods by 50%, and avoid the need for auxiliary electric resistance for both space- and water-heating. Tariff structures are highly varied between different utilities and currently reflect higher wholesale market prices for electricity during summer days. Consequently, although this system design provides large electric demand reductions during hypothetical 4-12-hour load shed periods, it does not provide energy cost reductions with current winter residential time-of-use tariffs.

Helmns, Dre↗

Decarbonization of Liquid Heating Fuels

Annually, residential and commercial buildings use about 5 billion gallons (18.9 billion liters) of distillate fuel for space and water heating. There is considerable interest in decarbonizing these markets through a combination of heat pumps and a future, carbon-free grid. An alternate approach that offers rapid and cost effective decarbonization involves substitution of low-carbon biofuels for fossil fuels within this market. Heating fuel marketers in North America and Europe are aggressively moving to achieve market penetration of biofuels. Processes for this include fuel specification standards, development of manufacturer-approved burners and all system components, development of standards for equipment listing, installation code changes, and generation of performance data. There has been considerable progress in these areas and each of these are reviewed in this paper. Currently, the most important biofuel for this market is biodiesel with a U.S. production capacity of 2.4 billion gallons (9.1 billion liters) and approximately a 75% reduction in GHG emissions. The biodiesel industry has stated a vision for dramatic increases in biodiesel production over the next decades. Fuel and equipment standards are in place to enable use of biodiesel blends to 20% and this blend is now widely used. Standard changes to extend this to as high as 100% biodiesel are nearing completion. Several states have implemented requirements for minimum levels of biodiesel in heating oil with these levels increasing over time.

09 BIOMASS FUELS↗

Direct Measurement of Diffusion Coefficients: Evidence for Diffusive Stochastic Heating in Collisionless Plasmas

Open questions in collisionless plasma dissipation can be addressed using space-based observations in different astrophysical environments, with implications for both astrophysical and laboratory plasma systems. We study a low-𝛽, highly imbalanced, sub-Alfvénic stream observed by Parker Solar Probe (PSP) to identify and distinguish between signatures of stochastic heating (SH) and resonant heating (RH) by parallel ion cyclotron waves (∥-ICWs). Prior work studying this stream [Trevor A. Bowen et al., Stochastic heating in the sub-Alfvénic solar wind, Phys. Rev. Lett. 135, 255201 (2025)] showed that the SH rate, accounting for intermittency, matched the amplitude of the local energy transfer (LET) rate, while the RH rate did not. This comparison relied on a number of assumptions regarding the nature of the diffusive process and the calculation of the LET rate. We introduce a novel technique of inverting the proton guiding center equation to empirically measure velocity-space diffusion coefficients using three-dimensional proton velocity distribution functions, from the ion electrostatic analyzer (the Solar Probe Analyzer for Ions) on PSP. Measured diffusion coefficients are used to determine phase-space heating rates, leading to a calculation of a fully kinetic heating rate independent of assumptions made in prior work. We show that scale-dependent analytic expressions for SH via noncoherent fluctuations match the empirical measurements from PSP data, provided that we account for intermittency in the heating calculation. In contrast, the derived heating rates for SH that accounts for the effects of the helicity barrier and heating rates for RH via ∥-ICWs do not peak in the same region of velocity space as the empirical measurements, nor do they reach the required magnitude. Our approach provides novel methodology to uniquely identify and constrain heating processes in collisionless plasmas and shows evidence of a Fokker-Planck-like diffusive process in the near-Sun solar wind.

Plasma kinetic theory↗

Lab Evaluation of Downward Capacity of Radiant Ceiling Panel Systems

This project investigated the cooling delivery effectiveness of radiant ceiling panels as a function of attic insulation level using multiple laboratory testing and analytical methodologies. Delivery effectiveness is the heating or cooling energy delivered to a conditioned space divided by the total heating or cooling energy added or removed by the space conditioning system. The lower the losses of the heating or cooling delivery method, the higher the delivery effectiveness. For ducted systems, delivery effectiveness is reduced by both air leakage and thermal losses (especially if the ducts are installed in attics), while the delivery effectiveness of a radiant system supplied by hot and cold water is only reduced by thermal losses, which can be mitigated by sufficient insulation above, or at the "back" of the panel. Being installed at or below the ceiling plane, sufficient back insulation should be provided by default in the form of the attic insulation above the radiant ceiling panels. Site-built radiant ceiling panels were evaluated at Frontier Energy’s Building Science Research Laboratory (BSRL) in a uniquely designed environmental test chamber with independently controllable indoor and attic spaces and a height-adjustable ceiling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Catalyzing the Mass Adoption of High Efficiency Technologies in the Multifamily Housing Market

ICAST’s objective was to catalyze the adoption of very-high-efficiency (VHE) heat pump HVAC (mini-splits) and water heaters (HPWH) in multifamily (MF), especially affordable housing (MFAH). Nationally, the market penetration of ENERGY STAR-certified ASHPs is estimated at 43%, and for HPWHs it’s 3% (ENERGY STAR, 2022). Note that mini-splits are a much more practical choice for MF units than ducted systems and their adoption is only a portion of the number provided above, but isolating the market penetration data for mini-split systems is difficult. Both the heat pump-based HVAC and water heater systems can be approx. three times more efficient than their conventional counterparts for space and water heating. While awareness and adoption of VHE heat pumps has been growing nationally, and electric heat pump systems have outsold gas furnaces for two years in a row, the MF segment continues to lag behind single-family. MF constitutes almost a third of the housing in the U.S., so scaling up VHE adoption in this segment can assist in achieving critical climate change goals, while preserving housing affordability for the low-to-moderate income (LMI) population (historically, 85% of residents of MF are LMI).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transition from wall modes to multimodality in liquid gallium magnetoconvection

Coupled laboratory-numerical experiments of Rayleigh-Bénard convection in liquid gallium subject to a vertical magnetic field are presented. The experiments are carried out in two cylindrical containers with diameter-to-height aspect ratio Γ = 1.0 and 2.0 at varying thermal forcing (Rayleigh numbers 10 5 ≲ Ra ≲ 10 8 ) and magnetic field strength (Chandrasekhar numbers 0 ≲ Ch ≲ 3 × 10 5 ). Laboratory measurements and numerical simulations confirm that magnetoconvection in our finite cylindrical tanks onsets via nondrifting wall-attached modes, in good agreement with asymptotic predictions for a semi-infinite domain. With increasing supercriticality, the experimental and numerical thermal measurements and the numerical velocity data reveal transitions between wall mode states with different azimuthal mode numbers and between wall-dominated convection to wall and interior multimodality. These transitions are also reflected in the heat transfer data, which combined with previous studies connect onset to supercritical turbulent behaviors in liquid metal magnetoconvection over a large parameter space. The gross heat transfer behaviors between magnetoconvection and rotating convection in liquid metals are compared and discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

City-Scale Building Anthropogenic Heating during Heat Waves

More frequent and longer duration heat waves have been observed worldwide and are recognized as a serious threat to human health and the stability of electrical grids. Past studies have identified a positive feedback between heat waves and urban heat island effects. Anthropogenic heat emissions from buildings have a crucial impact on the urban environment, and hence it is critical to understand the interactive effects of urban microclimate and building heat emissions in terms of the urban energy balance. Here we developed a coupled-simulation approach to quantify these effects, mapping urban environmental data generated by the mesoscale Weather Research and Forecasting (WRF) coupled to Urban Canopy Model (UCM) to urban building energy models (UBEM). We conducted a case study in the city of Los Angeles, California, during a five-day heat wave event in September 2009. We analyzed the surge in city-scale building heat emission and energy use during the extreme heat event. We first simulated the urban microclimate at a high resolution (500 m by 500 m) using WRF-UCM. We then generated grid-level building heat emission profiles and aggregated them using prototype building energy models informed by spatially disaggregated urban land use and urban building density data. The spatial patterns of anthropogenic heat discharge from the building sector were analyzed, and the quantitative relationship with weather conditions and urban land-use dynamics were assessed at the grid level. The simulation results indicate that the dispersion of anthropogenic heat from urban buildings to the urban environment increases by up to 20% on average and varies significantly, both in time and space, during the heat wave event. The heat dispersion from the air-conditioning heat rejection contributes most (86.5%) of the total waste heat from the buildings to the urban environment. We also found that the waste heat discharge in inland, dense urban districts is more sensitive to extreme events than it is in coastal or suburban areas. The generated anthropogenic heat profiles can be used in urban microclimate models to provide a more accurate estimation of urban air temperature rises during heat waves.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SEASONAL PERFORMANCE SIMULATION OF A GAS-FIRED CHEMISORPTION HEAT PUMP FOR RESIDENTIAL HEATING IN COLD CLIMATE

The gas-fired chemisorption heat pump (CSHP) is a promising technology for high-efficiency cold-climate residential heating. The CSHP utilizes the heat of reversible chemical reactions between sorbent and refrigerant to extract heat from cold ambient and supply high-temperature heat to the indoors. The efficiency of CSHP depends on the ambient and heat rejection temperatures. This study evaluates the seasonal performance of a CSHP by first develop a dynamic system model to generate a performance map for various ambient and heat-supply temperatures; then the bin method is used to evaluate the CSHP seasonal performance in two cold-climate locations for space and water heating.

Yang, Zhiyao↗

Heat Transfer, Refrigeration and Heat Pumps

The Special Issue entitled “Heat Transfer, Refrigeration and heat Pumps” accepted papers covering a wide range of topics related to heat pumps, thermal energy storage, and low-Global Warming Potential (GWP) alternative refrigerants. Heat pumps play a vital role in providing space conditioning and water heating while utilizing the energy of the environment. Since heat pumps use renewable thermal energy from the environs to provide the desired utility, they contribute to the portfolio of technologies that mitigate carbon footprint. The heat pump may be considered a truly renewable technology if the electricity it uses comes entirely from a renewable source. More accurately, a heat pump is a “low carbon technology”. These perspectives make heat pumps an indispensable option for the future in order to reduce the nocuous human impact on the environment. More efficient heat pumping technologies are being developed for the residential, commercial, and industrial sectors of the economy. Another R&D thrust is heat pumps for cold climates. Hardware components, use of low-GWP refrigerants, and identification of systemic inefficiencies are active research areas. This article is a synopsis of the papers submitted to the Special Issue.

42 ENGINEERING↗

G-Function Library for Modeling Vertical Bore Ground Heat Exchanger

This library contains g-functions (thermal response functions) for standard, regularly spaced vertical borehole ground heat exchangers. In total, it contains 34, 321 configurations. To permit interpolation, each configuration has g-functions for heights of 24, 48, 96, 192, and 384 m. All the g-functions were calculated with burial depths of 2m, and borehole diameters of 15 to 17.5 cm, depending on height. In configurations with uniform spacing, the spacing between the boreholes is set to 5m, though it can be scaled to other horizontal spacings.

15 GEOTHERMAL ENERGY↗

Improved MPACT energy deposition and explicit heat generation coupling with CTF

The CASL neutronics code MPACT assumes local energy deposition with equilibrium delayed energy for steady-state and transient calculations. These approximations limit the accurate representation of the heat generation in space and its variations over time, both of which are essential for power distribution and thermal–hydraulic coupling analyses. This paper presents an explicit energy deposition model considering the neutron and gamma heating of all regions and the time-dependent delayed energy. The MPACT/CTF interfaces are updated to transfer the explicit heat sources. The new model agrees well with MCNP for problems without thermal–hydraulic feedback. The MPACT/CTF coupled calculation for a hot-full-power quarter-core case using the new model exhibits a reduction of peak pin power by 2.3% and fuel centerline temperature by 17 K. The new model also shows a keff difference up to -100 pcm in depletion and a 30 K peak fuel temperature reduction in a reactivity-initiated-accident problem.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-temperature NMR MAS probe with optimized temperature gradient across sample rotor

A rotor housing assembly for NMR spectroscopy. An elongate rotor has a distal drive end, a proximal end and an internal sample space positioned along its length between the drive and proximal ends. The rotor is driveable about a rotation axis by a drive gas flow. A rotor housing has an interior space in which the rotor is at least partially received. At least one first heated gas flow inlet is positioned opposite the internal sample space, through which a first heated gas flow is controllably flowable into the interior space to heat it and the rotor. At least a pair of spaced apart second heated gas flow outlets are axially spaced from the first heated gas flow inlet to controllably convey a second heated gas flow to heat distal and proximal areas of the sample space to minimize a temperature gradient extending axially within the sample space.

Mehta, Hardeep S.↗

SPHERE Assembly and Operation Demonstration

The objective of the current scope was to complete single primary heat extraction and removal emulator (SPHERE) assembly and demonstrate the operation of the SPHERE facility. The initial testing consisted of vacuum operation of a sodium heat pipe. The temperature was measured at 10 evenly spaced points along the heat pipe. Additional exterior thermocouple measurements were also taken on the exterior of the heat pipe to confirm the similarity of thermowell temperatures to exterior heat pipe temperature measurements. The initial test was successfully completed and results measured at INL are consistent with the data from the manufacturer.

42 ENGINEERING↗