Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Implementation of an impurity diagnostic suite on the Pegasus-III experiment

A suite of diagnostics used to assess impurity content and dynamics has been updated, upgraded, and installed on the Pegasus-III Experiment. Typical plasma parameters during local helicity injection start-up are τ shot ~10 ms, n e ~ 1 × 10 19 m –3 , and T e ~ 50 eV. The deployed diagnostics are compatible with this modest temperature and density regime and provide species identification, source localization, and estimation of radiation losses. Impurity species are determined by recording time-evolving, single line-of-sight spectra at 1.25 kfps using a SPRED (Survey, Poor Resolution, Extended Domain) vacuum ultraviolet spectrometer. SPRED is equipped with 450 g/mm grating, giving a spectral resolution of 0.33 nm and a spectral range from ~10 to 110 nm, useful to identify light impurity species in this temperature and density range. An absolutely calibrated spectrometer that collects light from the plasma at R tan = 15.9 cm and Δt ≥ 2 ms is used as a visible survey spectrometer and for continuum measurements. The radiated power from the plasma is estimated with a photodiode-based diagnostic. Two 16-channel absolute extreme ultraviolet diode arrays are placed behind pinhole apertures, resulting in 32 lines of sight at Z = 0, with a spatial resolution of 2–3 cm and a time response of 60 kHz. A photometrically calibrated collinear D α /near infrared filtered photodiode-based system measures the D α emission and around 1040 nm. All these instruments have been designed to suppress electromagnetic interference from megawatt-class switching power supplies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of mosaic crystal instrument functions on x-ray Thomson scattering diagnostics

Mosaic crystals, with their high integrated reflectivities, are widely employed in spectrometers used to diagnose high energy density systems. X-ray Thomson scattering (XRTS) has emerged as a powerful diagnostic tool of these systems, providing in principle direct access to important properties such as the temperature via detailed balance. However, the measured XRTS spectrum is broadened by the spectrometer instrument function (IF), and without careful consideration of the IF one risks misdiagnosing system conditions. Here, we consider in detail the IF of 40 and 100 μm mosaic Highly Annealed Pyrolytic Graphite crystals, and how the broadening varies across the spectrometer in an energy range of 6.7–8.6 keV. Notably, we find a strong asymmetry in the shape of the IF toward higher energies. As an example, we consider the effect of the asymmetry in the IF on the temperature inferred via XRTS for simulated 80 eV CH plasmas and find that the temperature can be overestimated if an approximate symmetric IF is used. We, therefore, expect a detailed consideration of the full IF will have an important impact on system properties inferred via XRTS in both forward modeling and model-free approaches.

47 OTHER INSTRUMENTATION↗

A platform for non-local thermodynamic equilibrium atomic physics research using the buried layer target approach at a kJ level laser facility

Here we present a design and first use of a kJ level laser facility for research of non-local thermodynamic equilibrium atomic physics using the buried layer target method. The target design included a metal layer buried inside a plastic tamper with thicknesses tailored to the expected laser intensities. The target was illuminated from each side by two laser beams with intensities of 0.5–5 × 10 14 W/cm 2 . The advanced diagnostic suite included static and time-resolved imagers and spectrometers with various spectral resolutions. A 3D printed dual elliptically curved spectrometer is presented, and its results are compared to a traditional crystal spectrometer. Experimental results and radiation hydrodynamic simulations demonstrate that the target achieved the desired thermodynamic conditions of n e ≈ 10 21 –10 22 cm -3 and T e ≈ 1–2 keV.

3D printing↗

The inertial confinement fusion experimental platform and diagnostics for studies of nuclear reactions relevant to nuclear astrophysics

High energy density plasmas generated in laser-driven inertial confinement fusion implosions provide unparalleled laboratory conditions for studying stellar-relevant nuclear reactions: plasma environment; hot and dense; uniquely high achievable neutron flux. These experiments have the potential to address long-standing questions about plasma effects on nuclear reactions hitherto experimentally inaccessible, including nuclear rates with thermally distributed reactants, plasma screening, and reactions involving nuclei in excited states. The National Ignition Facility (NIF) and OMEGA lasers are two primary facilities for executing experiments of this type. Existing and future nuclear diagnostics, along with supporting diagnostics to characterize the platform, enable exploitation of these plasmas for such nuclear astrophysics-relevant experiments. Here, this review describes the nuclear diagnostic capabilities currently available for these types of experiments at the NIF and OMEGA, including neutron time-of-flight spectrometers, charged-particle detectors, gamma detectors and radiochemistry diagnostics, and briefly summarizes other available diagnostic capabilities used for platform characterization. Enabling tools not yet available are also identified, including a rapid radioactive sample retrieval system, a low-energy neutron spectrometer and a high-efficiency gamma spectrometer.

National Ignition Facility↗

The meV-resolved Inelastic X-ray Scattering Beamline at NSLS-II: Design and Performance

The ultrahigh resolution inelastic X-ray scattering (IXS) beamline at NSLS-II is designed and built to achieve sub-meV resolution at a moderate energy of 9.13 keV for IXS experiments with high momentum resolution and high spectral contrast. The key instrument is a novel spectrometer featuring a new type of analyzer optics, which combines post-sample collimation with angular dispersive crystal optics. As the first user instrument of its kind, the spectrometer has demonstrated unique research capabilities in exploring low momentum transfer (Q), THz dynamics in soft material systems characterized by mesoscopic heterogeneity and complexity, such as liquid crystals and bio-membranes. Ongoing efforts to improve performance since the start of user operations have resulted in a state-of-the-art energy resolution in routine operations of less than 1.4 meV, with sharp Gaussian-like tails, making it a premier IXS spectrometer for studying the dynamics of soft materials, while also delivering competitive performance for investigating phonon dynamics in hard condensed matter systems, including a broad range of quantum materials.

43 PARTICLE ACCELERATORS↗

Reconstruction of neutrino events in the Accelerator Neutrino Neutron Interaction Experiment. Part I

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) was designed to reconstruct neutrino events from the Fermilab Booster Neutrino Beam (BNB) with the parallel goals of measuring neutron production in interactions with oxygen and serving as a testbed for new technology. The ANNIE detector consists of a 26-ton water Cherenkov target tank instrumented with conventional photomultiplier tubes (PMTs), a downstream tracking muon spectrometer, and an upstream double wall of plastic scintillator to serve to veto charged particles incoming from neutrino events that occur upstream of the experimental setup. ANNIE has also deployed multiple Large-Area Picosecond PhotoDetectors (LAPPDs) and a test vessel of water-based liquid scintillator (WbLS). This paper describes the event reconstruction performance of the detector before implementation of these novel technologies, which will serve as a baseline against which their impact can be measured. That said, even the techniques used for event reconstruction using only the conventional PMT array and muon spectrometer are significantly different than those used in other water Cherenkov detectors due to the small size of ANNIE (which makes nanosecond-scale timing not as useful as in a large detector) and the availability of reconstruction information from the tracking muon spectrometer. We demonstrate that combining the information from these two elements into a single fit using only pattern recognition yields a muon vertex uncertainty of 60 cm, a directional uncertainty of 13.2 degrees, and energy reconstruction uncertainty of about 10% for BNB muon neutrino Charged Current Zero Pion (CC0π) events.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Direct Reactions and Spectroscopy with Hydrogen Targets at the RIBF

The implementation of MINOS, a liquid-hydrogen target and vertex-tracking system, at the Radioactive Isotope Beam Factory (RIBF) of the RIKEN Nishina Center has led to numerous nuclear physics discoveries. In experiments involving rare-isotope beams at intermediate energies, MINOS was integrated with the DALI2 + γ-ray spectrometer and other auxiliary devices. These were positioned in front of both the ZeroDegree Spectrometer and the SAMURAI magnetic spectrometers for the identification of ejectiles following quasi-free scattering direct reactions. Notable outcomes include the first spectroscopy of unstable doubly magic nucleus, investigations into multi-neutron decays, and the study of shell evolution along isotopic chains. These studies have significantly advanced our understanding of nuclear structure, as well as the mechanism of direct reactions with fast beams. Simultaneously, these direct reactions enabled raising new physics questions and paved the way for next-generation experimental setups to address them. Through the combination of particle- and γ-spectroscopy with a broad range of nuclear reactions, new frontiers will be established in our understanding of nuclear structure and reaction mechanisms. Here, we review the past ten years of studies on direct reactions and spectroscopy of exotic nuclei with liquid-hydrogen targets at the RIBF and define a vision for the future.

Bertulani, Carlos A [East Texas A & M Univ., Comme↗

pathSQE : an automated workflow for single-crystal inelastic neutron scattering data processing and analysis

Inelastic neutron scattering (INS) experiments utilizing modern time-of-flight spectrometers enable the comprehensive mapping of the energy (E)- and momentum (Q)-resolved dynamical structure factor of single crystals, probing both the lattice and magnetic excitations. Yet, the large size and complexity of four-dimensional INS data are challenging current analysis workflows, often resulting in an underutilization of the measured information. To help address this issue, this paper introduces new software interfaced with the Mantid framework, pathSQE, designed to streamline the processing, analysis and interpretation of 4D single-crystal INS data. By automating key tasks such as 1D/2D slicing, symmetrization, Brillouin zone folding, data visualization, prioritization and filtering, and comparisons with simulations, pathSQE facilitates and accelerates INS data analysis workflows. Here, this paper outlines the features and implementation and provides several illustrations of the use of pathSQE on data collected on single crystals using direct-geometry time-of-flight spectrometers at the Spallation Neutron Source, including Ge, FeSi, MnO and SnS single-crystal measurements on the ARCS, HYSPEC and CNCS neutron spectrometers. Beyond streamlining post-experiment data processing, pathSQE establishes an automated and modular processing pipeline that could support future real-time experiment steering.

36 MATERIALS SCIENCE↗

Measuring X-Ray Emission Line Shapes in Neutral Species for XRISM Calibration

Space X-ray spectrometers such as the Resolve instrument on XRISM require precise calibration in order to interpret the spectra of astrophysical objects. Key components of the calibration are the energy scale and the core line spread function, both of which vary with photon energy. A major issue in the calibration of high-resolution spectrometers is locating good calibrators with well-known and stable intrinsic line shapes. Neutral fluorescence is widely used, but inner-shell transitions in neutral atoms often exhibit complex, poorly documented line shapes that vary with excitation conditions. Here, in this study, we present empirical measurements of K-shell transitions in neutral O and F below 1 keV using an engineering model XRISM calorimeter array, an electron bombardment modulated X-ray source, and an electron beam ion trap (EBIT) to provide a precise energy reference. In addition, we report measurements of the Mo Lα complex with the transition-edge microcalorimeter spectrometer (TEMS), which reveal strong satellite structure and sensitivity of the line shape to the incident exciting spectrum. Together, these results demonstrate the need for empirical line-shape models, highlight the nonstationary nature of neutral fluorescence features, and define a path toward developing transfer standards for XRISM and future precision instruments such as Athena/X-IFU.

Astronomy and AstroPhysics↗

Rapid monitoring of fermentations: a feasibility study on biological 2,3-butanediol production

2,3-butanediol (2,3-BDO) is an economically important platform chemical that can be produced by the fermentation of sugars using an engineered strain of Zymomonas mobilis . These fermentations require continuous monitoring and modification of fermentation conditions to maximize 2,3-BDO yields and minimize the production of the undesired coproducts glycerol and acetoin. Because of the time required for sampling and off-line chromatographic measurement of fermentation samples, the ability of fermentation scientists to modify fermentation conditions in a timely manner is limited. The goal of this study was to test if near-infrared spectroscopy (NIRS) along with multivariate statistics could reduce the time needed for this analysis and enable real-time monitoring and control of the fermentation. In this work we developed partial least squares (PLS) calibration models to predict the concentrations of glucose, xylose, 2,3-BDO, acetoin, and glycerol in fermentations via NIRS using two different spectrometers and two different spectroscopy modalities. We first evaluated the feasibility of rapid NIRS monitoring through experiments where we measured the signals from each analyte of interest and built NIRS-based PLS models using spectra from synthetic samples containing uncorrelated concentrations of these analytes. All analytes showed unique spectral signatures, and this initial modeling showed that all analytes could be detected simultaneously. We then began work with samples from laboratory fermentation experiments and tested the feasibility of regression model development across two spectral collection modalities (at-line and on-line) and two instruments: a laboratory-grade instrument and a low-cost instrument with a more limited spectral range. All modalities showed promise in the ability to monitor Z. mobilis fermentations of glucose and xylose to 2,3-BDO. The low-cost instrument displayed a lower signal-to-noise ratio than the laboratory-grade instrument, which led to comparatively lower performance overall, but still provided sufficient accuracy to monitor fermentation trends. While the ease of use of on-line monitoring systems was favored as compared to at-line systems due to the lack of sampling required and potential for automated process control, we observed some decrease in performance due to the additional complexity of the sample matrix. We have demonstrated that NIRS combined with multivariate analysis can be used for at-line and on-line monitoring of the concentrations of glucose, xylose, 2,3-BDO, acetoin, and glycerol during Z. mobilis fermentations. The decrease in signal-to-noise ratio when using a low-cost spectrometer led to greater prediction error than the laboratory-grade spectrometer for at-line monitoring. The on-line monitoring modality showed great promise for real time process control via NIRS.

09 BIOMASS FUELS↗

Understanding the Quadrupole Mass Filter and Testing a High-Resolution QMS RGA for ITER

A common type of residual gas analyzer is the quadrupole mass spectrometer. One of the main components within this instrument is a mass filter known as the quadrupole. It is responsible for the selective throughput of the ionized gas particles - by ascending mass number - prior to ion impacts on the analyzer (or detector) surface from which the ion current signal is generated for processing. However, the quadrupole is not fully described in relation to the electric field characteristics and the function as an ion mass separator. This paper describes the basic origins of the electrical design, the intricate assembly criteria, and performance of the quadrupole within the spectrometer. A specialized quadrupole mass spectrometer is part of a configuration for a diagnostic gas analyzer system planned for ITER, a fusion research machine. It has a verified capability, essential as a diagnostic criterion for this reactor project, to successfully deconvolute the mass signals of Helium-4 and deuterium (reactor fuel exhaust gases, separated by only 0.026 atomic mass units), down to a relative three-percent concentration of the former gas. The associated preliminary testing, performed at the Oak Ridge National Laboratory, is also addressed. Finally, one of the key parameters used to express gas concentration, the relative sensitivity factor, will be explained, including an evaluation of dependency on other variables.

Marcus, Chris [ORNL] (ORCID:0000000190139636)↗

Experimental Report: Multi-Instrument Comparison of AAF Size Distribution Instruments

Aerosols are particles suspended in the atmosphere, ranging in size from nanometers to micrometers. Their size distribution affects key atmospheric processes, including nucleation, coagulation, scavenging, activation, and radiative properties (Seinfeld and Pandis 2016). Aerosol size distribution is a critical parameter in atmospheric science, influencing processes such as cloud formation and radiative forcing. Accurate representation of aerosol size distributions is essential for understanding their impact on climate, air quality, and human health. However, aerosol size and composition vary significantly across time and space due to meteorological conditions and natural or anthropogenic sources. (Wu and Boor 2021). Various instruments are used to measure aerosol size distributions, each with distinct principles, advantages, and limitations. This report begins with an in-depth overview of aerosol size-distribution comparison studies, focusing on the passive cavity aerosol spectrometer probe (PCASP), portable optical particle spectrometer (POPS), ultra-high-sensitivity aerosol spectrometer (UHSAS), aerodynamic particle sizer (APS), and scanning mobility particle sizer (SMPS). All of these instruments are used by the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Aerial Facility (AAF), which commissioned this comparison and report. The report evaluates the strengths and weaknesses of these instruments, highlights their applications, and discusses efforts to merge data from multiple instruments for comprehensive analysis.

54 ENVIRONMENTAL SCIENCES↗

Aerosol Microphysics and Chemical Measurements at Mt. Soledad and Scripps Pier during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) from February 2023 to February 2024 UCSD Library Collection

This dataset includes guest instrument measurements and other PI products for aerosol microphysics and chemical measurements collected at Mt. Soledad and Scripps Pier during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) from February 2023 to February 2024. The measurements include the following instruments at Mt. Soledad: High-Resolution Time-of-Flight Aerosol Mass Spectrometer (HR-ToF-AMS, Aerodyne), Scanning Electrical Mobility Spectrometer (SEMS, Brechtel Manufacturing Inc.), Aerodynamic Particle Sizer (APS, Droplet Measurements Technologies), Single Particle Soot Photometer (SP2, Drople Measurements Technologies), Meteorological Station (WXT520, Vaisala), Ozone (Teco), and trace gas proxies (Teledyne). In addition, the analyses of particle filters collected at Mt. Soledad for three dry-diameter size cuts (<1 micron, <0.5 micron, <0.18 micron) and at Scripps Pier for one dry-diameter size cut (<1 micron) by Fourier Transform Infrared (FTIR) and X-ray Fluorescence (XRF) are reported. A differential mobility analyzer operated as a scanning mobility particle sizer (SMPS, TSI Inc.), a printed particle optical spectrometer (POPS, Grimm), and a continuous flow diffusion cloud condensation nuclei (CCN, DMT) counter provide the mobility aerosol size distribution (30-360 nm), optical size distribution (150 - 6000 nm), size-resolved CCN distribution (30-360 nm) at 0.2, 0.4, 0.6, 0.8, and 1.0% supersaturation. Measurements are reported for both sampling from an isokinetic aerosol inlet and from a Counterflow Virtual Impactor (CVI, Brechtel Manufacturing Inc.). The data are available at the following link: https://library.ucsd.edu/dc/collection/bb0898306q

54 ENVIRONMENTAL SCIENCES↗

Rapid native single cell mass spectrometry

A method for analyzing single cells by mass spectrometry includes the steps of providing a plurality of cells in a liquid medium and placing the cells and liquid medium in a single cell isolation and ejection system. Liquid medium containing a single cell is released from the single cell isolation and ejection system. The liquid medium and single cell are captured in a capture probe containing a flowing capture probe solvent. The cell is lysed by a lysis inducer in the capture probe to disperse single cell components into the medium. The lysed single cell components are transported to a mass spectrometer, where the lysed single cell components entering the mass spectrometer are spatially and temporally separated from any dispersed components of another single cell from the sample entering the mass spectrometer. Mass spectrometry is conducted on the lysed single-cell components. A system for analyzing single cells by mass spectrometry is also disclosed.

Cahill, John F.↗

Measurement of the Neutron Electromagnetic Form Factors at High Momentum Transfer Using a Polarized 3He Target at Jefferson Lab

Ever since the composite structure of nucleons was uncovered, many experiments have been commissioned with the purpose of extracting parameters that shape our understanding of this structure. Form factors are powerful tools that rest at the forefront of the nucleon structure study. In the non-relativistic limit, they describe the magnetic and charge distributions inside the nucleon. The GEn-II experiment, which ran in Hall A of Jefferson Lab as a part of the SuperBigbite Spectrometer (SBS) program, aimed to extract the ratio of the neutron’s electric to magnetic Sachs form factors (GnE/GnM. This was accomplished using the double polarization technique: scattering polarized electrons with initial energies up to 8.45 GeV off high-density polarized 3He targets. The experiment was a coincidence measurement, with the scattered electrons detected in the BigBite Spectrometer and the recoil nucleons in a hadron calorimeter, a part of the SuperBigbite Spectrometer. The convection-style target cells used in this experiment have a 60cm long target chamber, an increase from the 40 cm cell used in the most recent polarized 3He target experiment. In addition, the cells were optically pumped from two sides of the pumping chamber. These improvements in design and functionality introduced world-record-breaking luminosity. This thesis presents preliminary results of the GEn-II experiment for the following 4-momentum transfer (Q2) values: 2.93, 6.76, and 9.78 GeV2, in addition to target performance and preliminary polarimetry results.

Presley, Hunter [Univ. of Virginia, Charlottesvill↗

A Measurement of the Neutron Electromagnetic Form Factor Ratio from a Rosenbluth Technique with Simultaneous Detection of Neutrons and Protons

The internal structure of protons and neutrons provides insight into both the dynamical behavior of the constitute quarks and gluons, and emergent properties of the nucleons (such as mass, spin, and electromagnetic distributions). Elastic electron-nucleon scattering can probe the elastic electromagnetic form factors of the nucleon. The electric and magnetic form factors, respectively, encode information about the internal charge and magnetization distributions within the nucleon. Precision data for these form factors, over a broad range of the four-momentum transfer squared, Q^2, can benchmark theoretical models describing the strong interaction of nuclear physics. The Super BigBite Spectrometer (SBS) program in Hall A at Jefferson Lab, is a series of high-precision experiments which seek to significantly extend the Q^2 reach of previous data for the nucleon electromagnetic form factors. The first two experiments of this program are known as G_M^n and the neutron Two Photon Exchange (nTPE) and the data were collected from October 2021 to February 2022. Both experiments were conducted with the simultaneous measurement of D(e,e'n) and D(e,e'p) reactions for quasi-elastic electron-deuteron scattering. The scattered electrons were detected in the BigBite Spectrometer, which features multiple large-acceptance Gas Electron Multiplier (GEM) detectors. The Super BigBite Spectrometer provided simultaneous detection of scattered nucleons, and utilized a large acceptance dipole magnet and Hadron Calorimeter (HCal). The G_M^n experiment provides precision measurements of the neutron magnetic form factor, via the ratio method, over a Q^2 range of 3.0 to 13.5 (GeV/c)2. From this data analysis, preliminary values for G_M^n/µ_n G_D are extracted. For Q^2=4.48 (GeV/c)2 we find G_M^n/µ_n G_D=0.9546±0.0132 and for Q^2=4.476 (GeV/c)2 we find G_M^n/µ_n G_D=0.9563±0.0110. These preliminary G_M^n/µ_n G_D values are more precise than existing world data in this Q^2 regime and are consistent with the most recent parameterization of the G_M^n/µ_n G_D world data. The nTPE experiment provides a first measurement of the neutron Rosenbluth Slope and seeks to quantify the two-photon exchange(TPE) contribution to elastic electron-neutron scattering at a fixed Q^2=4.5 (GeV/c)2 with two different beam energies and scattering angle values. For data of the proton form factor ratio, µ_p G_E^p/G_M^p, significant discrepancies exist between values obtained from Rosenbluth Separation and polarization transfer measurement, particularly at large Q^2, and TPE contributions are thought to resolve this discrepancy. The impacts of TPE contributions have not yet been experimentally established for the neutron. From the data analysis presented in this dissertation, a preliminary result for the neutron Rosenbluth Slope is found as S^n=(G_E^n )^2/t_n (G_M^n )^2=0.0916±0.0476 for Q^2=4.48 (GeV/c)2. This value of the neutron Rosenbluth Slope is consistent with the world data extrapolation and the absence of large TPE corrections.

Wertz, Ezekiel [Thomas Jefferson National Accelera↗

Performance assessment after long-term irradiation of ATLAS Micromegas detectors using 120 GeV muons at the Gamma Irradiation Facility at CERN

The ATLAS muon spectrometer will face an increased particle rate as a result of the increased instantaneous luminosity expected during the High-Luminosity LHC (HL-LHC) upgrade. The HL-LHC will provide a luminosity of $\mathscr{L}$ = 7.5 × 10 34 cm −2 s −1 and 3000 fb −1 of integrated luminosity in 10 years, about 9 times more data of the ones so far collected by the ATLAS experiment. Micromegas chambers are used in the New Small Wheel(s), the first forward muon spectrometer station, to provide tracking and triggering at the intense particle rates expected. The detectors are operated with a ternary gas mixture composed of Ar + 5%CO 2 + 2%iC 4 H 10 , providing good high voltage stability and a large pulse height, important for inclined track reconstruction of particles crossing the detector. To ensure the long-term stable operation of the detector during the whole HL-LHC period, and due to the hydrocarbon content in the mixture, an extensive aging campaign has been ongoing since 2021 at the CERN Gamma Irradiation Facility, where spare production chambers are long-term exposed to a 14 TBq 137 Cs 𝛾-source, accumulating so far, a charge equivalent to five years of HL-LHC operations under the highest expected background rate. This paper describes the results of the Micromegas chamber performance studies after two years of gamma irradiation and using the SPS/H4 120 GeV muon beams at CERN.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Long Neglected Cycloidal Mass Analyzer

Cycloid mass spectrometers offer powerful advantages for isotope ratio measurements, including double focusing (mass and energy), linear mass dispersion over a large spatial area, and a small footprint. However, the linear cycloid has not been adopted as widely as other mass analyzer designs, in part because of challenges with utilizing common ion detectors such as electron multipliers and Faraday cups. Integration of a linear cycloid with a capacitive transimpedance amplifier detector arrays can overcome these challenges, resulting in a compact powerful mass spectrometer for precision isotope ratio measurements.

47 OTHER INSTRUMENTATION↗