Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectrum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Data for "Plasma shape effects on the Alfvén eigenmode spectrum through Alfvén slow-magnetosonic wave coupling"

electron density profile as a function of normalized poloidal flux: psinorm ne(10^20/m^3) dne/dpsiN Pressure profile as a function of normalized poloidal flux: psinorm ptot(KPa) dptot/dpsiN scaled to oftain beta=5% at magnetic axis Magnetic safety factor profile as a function of normalized poloidal flux: psinorm q_profile All needed to perform the NOVA calculations.

Alfven waves↗

Measurement of the galaxy-velocity power spectrum of DESI tracers with the kinematic Sunyaev-Zeldovich effect using DESI DR2 and ACT DR6

Joint analyses of high-resolution CMB temperature maps with galaxy surveys provide a unique way to reconstruct the radial velocity field of the underlying matter distribution via the kinematic Sunyaev-Zeldovich (kSZ) effect. Using data from the Atacama Cosmology Telescope (ACT) DR6 and the Dark Energy Spectroscopic Instrument (DESI) DR2, we present radial velocity reconstructions for luminous red galaxies (LRGs), emission-line galaxies (ELGs), and quasars (QSOs). Leveraging the spectroscopic data, we are able to reliably model the foreground contamination and report a negligible impact on our main observables. We detect the velocity-galaxy cross-correlation at $17.0σ$ for LRGs, and for the first time, at $8.3σ$ for ELGs and $6.8σ$ for QSOs. We further report the first detection of the velocity-velocity correlation using LRGs at $3.1σ$, as well as the highest cumulative detection of the kSZ effect to date at $20.8 σ$. Similarly to previous results, we find a lower amplitude of the kSZ signal compared to our fiducial halo model prediction and electron profile assuming a Battaglia profile. Combining these new observables, we obtain constraints on local-type primordial non-Gaussianity (PNG): $f_{\rm NL}^{\rm loc} = 15.9_{-34.4}^{+34.6}$ at 68% confidence, which represents the tightest constraint to date derived from the velocity field. The measurements presented here already exhibit lower noise on a per-mode basis than the galaxy auto-correlation on the largest scales, $k<0.004~\rm{Mpc^{-1}}$, highlighting the key role these observables will play in the context of future CMB experiments such as the Simons Observatory.

Chaussidon, Edmond [LBL, Berkeley] (ORCID:00000001↗

A317_Fast and Thermal Neutron Spectrum Dosimetry Measurements in the Advanced Test Reactor large-B and small-I Positions Following the Sixth Core Internals Change-out

The Advanced Test Reactor (ATR) has a wide variety of irradiation positions that have had experiments that were developed by users from around the world. Most experiment irradiations rely on thoroughly benchmarked numerical models. However, some irradiation positions in ATR are not as well- characterized and are complicated by spectral perturbations from control cylinder orientation. The “small I” and “large-B” irradiation positions are located nearby control cylinders and suffer from these flux perturbations from control cylinder orientations that change during an irradiation cycle to maintain the desired core power distribution. Models predicted that these types of position would exhibit both spectral shifts and amplitude changes in neutron flux, but few measurements have been conducted to benchmark these predictions. Recently, requalification testing was performed to confirm the operational readiness of the ATR following the completion of the Core Internals Change-out (CIC). These tests provided a unique opportunity to validate the analytical methods used to simulate the ATR because nearly all components in the reactor were in a clean as-built state, significantly reducing modelling uncertainties. One subset of the testing included characterization of the fast and thermal neutron flux in the “small-I” and “large-B” positions using silver, cobalt, and nickel neutron dosimetry. In contrast to typical irradiation cycles, the control cylinders were held in position during the post-CIC nuclear testing. The specific activity of these dosimeter wires was measured following two low-power tests with different control cylinder positions.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Validation and Verification of Python based Neutron Spectrum Unfolding Software

To validate and verify the python-based code (PySL), designed to replicate the programs used by STAYSL for Beam Correction Factor (BCF) and Self-Shielding Factor (SHIELD), a series of tests were performed. To test BCF a python script was written to generate a random flux history file and both versions of the code processed the data. The test verified matching values up to at least one decimal place, approximately 10,000 tests where run and each one passed. Isotopes began to fail the tests once neutron saturation was reached. To verify this the total time of exposure was varied the isotopes that failed were compared to a list of their half-lives. The test process for SHIELD was very similar but, in this case, the code began by producing an input file with varying thickness and device type/environment for the SHIELD input. The failure condition for this test was if any of the data points for an isotope had a difference above 3%. Approximately 40 of these tests were run and there were only 3 isotopes that had reoccurring failures but only 2% of their points were above the 3% difference. A visual comparison was conducted by plotting the results from both programs. Although the test failed, the differences between their values were minuscule, and the self-shielding factor’s shape was preserved when plotted. Next steps for this project will be validating and verifying the python-based SigPhi code and then reproducing and testing the least squares unfolding performed by STAYSL.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photoproduction of K0K0-bar with the GlueX Experiment

In this dissertation, we study photoproduction of K0 ?K 0 through the KSKLp and KSKSp ?nal states with the GlueX Phase-I (GlueX-I) data set. We measure the spin-density matrix elements (SDMEs) and di?erential cross section of ?(1020) ! KSKL to better understand photoproduction of light vector mesons. A mass independent Partial Wave Analysis (PWA) of the KSKL and KSKS meson spectrum below 2 GeV is also undertaken to study the meson spectrum with JPC = even++ and odd??. The ?(1020) di?erential cross section is measured at E = 8:2 ? 8:8 GeV and ?t = 0:15 ? 1:00 GeV2. The di?erential cross section is well described by an exponential decay with slope 4:44?0:01 GeV?2 and the integrated cross section is determined to be 295:7?0:4 nb, only statistical uncertainties are quoted. Both measurements are consistent and far more precise than the previous measurement by Ballam et al. [1]. The ?(1020) SDMEs were measured in nine bins of ?t in the same range. At low ?t, we ?nd the data were consistent with s-channel helicity conservation, SCHC, i. e. the only non-zero SDMEs were ?1 1?1 = ?Im(?2 1?1) = 1=2. At higher ?t, the SDMEs deviate from SCHC and the measurements indicate this is due to natural parity exchange since we observe that the SDMEs are consistent with zero unnatural exchange. We also ?find that the contribution from helicity double-flip amplitudes is consistent with zero. The measured SDMEs are in poor agreement with theoretical predictions put forward by JPAC [35]. These measurements will serve as input to re?ne models of production processes, which will be essential for the interpretation of possible signals of exotic mesons in GlueX. Analysis of the spectrum above the ?(1020) indicates the presence of at least three particles at ? 1:50, ? 1:75, and 2:20 GeV. We employ simple parametrizations of the resonance line shape based on relativistic Breit-Wigner functions considering cases with and without interference. The resonance at ? 1:50 GeV is not identifi?ed as any specifi?c resonance, but could be due to interference between the ?(1450) and !(1420). Our models favor the resonance at ~1:75 GeV as the X(1750) rather than the ?(1680). We ?find that introducing a third Breit-Winger into the models improves the ?t quality with the ?2/ndf going from 1.75 to 1.59 and 1.41 to 1.18 for models without and with interference respectively. A PWA of the KSKL spectrum indicates that the spectrum is consistent with exclusively spin-1 contribution up to ? 1:6 GeV. Above ? 1:6 GeV we ?find evidence for a small spin-3 contribution. We also ?nd that the spectrum predominantly positive reflectivity up to ? 1:6 GeV, after which the spectrum becomes a nearly equal mix of both. The KSKS system shows a rich spectrum with multiple resonance structures but is more statistically limited than the KSKL system. Modelling the line shape we ?find evidence at greater than 10? level in favor of a resonance at ? 1:75 GeV. The model parameters suggest this resonance is the f0(1710). The PWA of the KSKS system was inconclusive. However, using a small set of amplitudes suggests that the spin-2 contribution to the spectrum is primarily in the range 1:2?1:6 GeV, where f2(1270), a2(1320) and f02 (1525) are expected.

Linera, Gabriel Rodriguez↗

Low energy neutron light output characterization of EJ301D and deuterated stilbene with a comparison of light output characterization methods

The neutron-induced light yield of a 2.54 cm diameter by 2.54 cm long right circular cylinder of EJ301D and a (5.08 cm)3 custom made cube of deuterated trans-stilbene-d12 (d-stilbene) were measured over incident neutron energies from 300 keV to 2.2 MeV and 200 keV to 2.4 MeV, respectively. The measurements were performed using a time-of-flight experiment with a Cf-252 source and an approximately 1.5 m flight path. We compare three light output spectrum full energy deposition edge estimation methods: (1) simulating the neutron energy spectrum edge and fitting it to the light output spectrum, (2) using the inflection point of the light output spectrum edge (derivative method, a.k.a. Kornilov’s method), and (3) using an empirical model fit to the edge of the light output spectrum. Both the derivative and equation fit methods do not account for physical processes such as multiple neutron scattering in the detectors. They instead rely on assumptions about the linear shape continuum shape of the light output spectrum and the direct correlation between the location of the spectrum’s inflection point and maximum energy deposition. These assumptions were found to introduce bias into those methods when tested against simulated spectra with known edge locations. When tested against measured spectra the derivative method was found to differ from the simulation fit by greater than 30% at low energies with large discontinuities for adjacent data points above 800 keV incident neutron energy. The empirical equation fitting method was found to also exhibit bias of a similar magnitude, but with significantly more continuous behavior, especially with the lower count data of the smaller volumed EJ301D scintillator. Experimental light output yield for this neutron energy range is reported using the simulated spectrum fitting method because it includes physics neglected by the other methods, and did not exhibit the bias observed in the other methods

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Godiva IV central cavity neutron environment characterization with threshold neutron detectors

Godiva IV is a cylindrical fast burst reactor comprised of approximately 65 kg of highly enriched uranium that is operated by Los Alamos National Laboratory and sited at the National Criticality Experiments Research Center at the Nevada National Security Site in Nevada in the United States. Godiva IV is typically operated at delayed critical and in the regime spanning from sub-prompt to super-prompt bursts. Godiva IV is used for sample irradiations, criticality safety demonstrations, dosimetry studies, and for studying super-prompt behavior. In preparation for both an upcoming experiment to reduce uncertainties in the prompt fission spectrum for 235U using threshold neutron detectors, and for future research using Godiva IV, it was desired to exercise the process of the selection of threshold neutron detectors/activation foils, radiation metrology, and the subsequent adjustment of the neutron spectrum. For this exercise, nine high purity threshold neutron detectors/activation foils were irradiated in a Godiva IV burst. The foils were then analyzed using a high-purity germanium detector in the NCERC counting laboratory to determine end of irradiation specific activities for available IRDFF-II reactions. This work summarizes the Godiva IV foil irradiation, radiation metrology results, and adjusted neutron spectrum. The results of this exercise ultimately characterized the neutron environment inside the sample irradiation cavity inside Godiva IV to a higher degree than previously performed, informed decisions for the upcoming larger scale experiment, and will inform future neutron spectrum characterizations at NCERC.

Whitman, Nicholas H.↗

Godiva IV Simulated Radiation Field Characterization and Variance Reduction

Godiva IV is a system comprised of highly enriched uranium alloyed with molybdenum in the form of fuel plate rings. The reactor, along with its predecessors, was designed with the unique ability to satisfy interests in the super-prompt-critical reactor operation space. Originally, the reactor was part of the Los Alamos Critical Experiments Facility (LACEF) at Technical Area-18 (TA-18). The radiation field around Godiva at this facility was well characterized and understood. As a fast neutron system, the neutron spectrum in and around Godiva was close to a Watt Fission spectrum. The Kiva where Godiva IV was located at LACEF was made of thin, sheet metal walls which did not contribute significantly to the neutron spectrum. Following the transition of LACEF to the National Critical Experiments and Research Center (NCERC) in Nevada, Godiva-IV was moved from TA-18 to the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS). Part of this move brought renewed interest in radiation field characterization. The new facility introduced significant changes to the environment surrounding Godiva, and preliminary foil irradiation results suggested that the room contribution to the neutron spectrum was significant. Unlike at TA-18, a large thermal neutron signature was added to the fast spectrum from Godiva due to significant room return. A primary goal due to the additional complexity that the room return adds to the Godiva IV radiation emission spectrum was the development of an efficient Monte Carlo N-Particle (MCNP) calculation capable of characterizing the neutron spectrum anywhere in the room around Godiva. A campaign of activation foil irradiations and analysis were completed to support the validation of the MCNP model. The modeling of these foils in MCNP can be easily done with a standard volumetric neutron flux tally. However, given the multitude of locations and reaction rates to be modeled, further steps must be taken to increase the efficiency of these calculations in MCNP. During this study, a benchmark model currently under development for Godiva IV was used. A qualitative assessment of the thermal neutron contributors was performed using spatial neutron distribution plots. Additional detail was added to the model based on the qualitative results showing the thermal spectrum’s large sensitivity to hydrogenous material. Neutron energy spectra was evaluated at discrete locations in the room around Godiva to quantify the relative contribution of various components. It was discovered that the concrete walls are the largest contributor to the thermal signature, with minor contributions from plastic components surrounding Godiva. Following these results, two different variance reduction techniques were implemented to improve the problem efficiency in these calculations. In the first approach, an F5 point detector tally was implemented in the standard Godiva IV criticality problem. The second approach involved a weight-window generator implementation with an F5 point detector tally in a fixed source problem. The weight window implementation reduced the runtime from 42739.55 minutes to 1803.34 minutes (computer time), compared to the F5 KCODE implementation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

7-8 GHz Point-to-Point Testing

Wireless spectrum is a limiting resource for continued economic growth in the United States. As discussed in the recent National Spectrum Strategy (NSS), wireless spectrum underpins several aspects of the U.S. economy and the demand for additional spectrum is driving the need for realizing spectrum sharing to enable continued development. At the same time, wireless spectrum is an essential foundation of critical energy infrastructure, including electric, oil, and natural gas resources. In particular, wireless point-to-point (P2P) links are the backbone of vast infrastructure networks that enable the flow of sensor and control information needed to manage critical energy sector infrastructure in the United States. These links will only become more important as the energy sector incorporates more diverse sensing and more efficient control mechanisms, which increases system complexity and data volume requiring more resilient communications. Therefore, the continued economic development of the U.S. depends on determining novel approaches to spectrum management that balance both broad access for advanced wireless technologies and resilience for critical infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of Source Geometry on Detector Response Matrix Efficiency: Simulations of the PFUNS-MUSiC Experiments

This work looks at two different bare highly enriched uranium (HEU) systems, configuration one from Measurements of Uranium Subcritical and Critical (MUSiC) and Prompt Fission Uranium Neutron Spectrum (PFUNS) to see the effect geometry has on detector efficiency and the response matrix. The distance from the multiplying source, the medium between the source and detector, and the geometry of the source all play a part in the efficiency of the detector. These factors are especially important when performing spectrum unfolding. Spectrum unfolding is a process used to reconstruct a true spectrum from measured detector response data. It involves interpreting a set of measured values, such as a light signal from a scintillator, to recover the original neutron energy spectrum. This leads to the question, how much will the efficiency of a detector change when you measure a point source compared to an extended source? The distance and solid angle from the source to the detector may be different. It may only be a minuscule change, but in the spectrum unfolding process it can have a considerable effect on the unfolded spectrum

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cosmology From CMB Lensing and Delensed EE Power Spectra Using 2019-2020 SPT-3G Polarization Data

From CMB polarization data alone we reconstruct the CMB lensing power spectrum, comparable in overall constraining power to previous temperature-based reconstructions, and an unlensed E -mode power spectrum, with clear detections of the third through tenth acoustic peaks. The observations, taken in 2019 and 2020 with the South Pole Telescope (SPT) and the SPT-3G camera, cover 1500 deg 2 at 95, 150, and 220 GHz with arcminute resolution and roughly 4.9 µ K-arcmin coadded noise in polarization. The power spectrum estimates, together with systematic parameter estimates and a joint covariance matrix, follow from a Bayesian analysis using the Marginal Unbiased Score Expansion (MUSE) method. The E -mode spectrum at ℓ > 2000 and lensing spectrum at L > 350 are the most precise to date. Assuming the ΛCDM model, and using only these SPT data and priors on τ and absolute calibration from Planck, we find H 0 = 66.81 ± 0.81 km/s/Mpc, comparable in precision to the Planck determination and in 5.4 σ tension with the most precise H 0 inference derived via the distance ladder. We also find S 8 ≡ σ 8 (Ω m /0.3) 0.5 = 0.850 ± 0.017, providing further independent evidence of a slight tension with low-redshift structure probes. The ΛCDM model provides a good simultaneous fit to the combined Planck, ACT, and SPT data, and thus passes a powerful test. Combining these CMB datasets with BAO observations, we explore extensions to the ΛCDM model. We find that the effective number of neutrino species, spatial curvature, and primordial helium fraction are consistent with standard model values, and that the 95% confidence upper limit on the neutrino mass sum is 0.075 eV, close to the minimum sum expected from observations of solar and atmospheric neutrino oscillations. The SPT data are consistent with the somewhat weak (< 3 σ ) preference for excess lensing power seen in Planck and ACT data relative to predictions of the ΛCDM model given the combined Planck, ACT, and BAO data sets. Finally, we also detect at greater than 3 σ the influence of non-linear evolution in the CMB lensing power spectrum and discuss it in the context of the S 8 tension. Forthcoming SPT-3G analyses will feature deeper and wider observations in temperature and polarization, providing even tighter constraints and more powerful tests of the ΛCDM model.

79 ASTRONOMY AND ASTROPHYSICS↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗