Search NASA⌕ Search

SEARCH · Search NASA

Results for “Storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Electrochemical Orbital Energy Storage (ECOES) technology program

The versatility and flexibility of a regenerative fuel cell power and energy storage system is considered. The principal elements of a Regenerative Fuel Cell System combine the fuel cell and electrolysis cell with a photovoltaic solar cell array, along with fluid storage and transfer equipment. The power output of the array (for LEO) must be roughly triple the load requirements of the vehicle since the electrolyzers must receive about double the fuel cell output power in order to regenerate the reactants (2/3 of the array power) while 1/3 of the array power supplies the vehicle base load. The working fluids are essentially recycled indefinitely. Any resupply requirements necessitated by leakage or inefficient reclamation is water - an ideal material to handle and transport. Any variation in energy storage capacity impacts only the fluid storage portion, and the system is insensitive to use of reserve reactant capacity.

Mcbryar, H.↗

Storage, transmission and distribution of hydrogen

Current practices and future requirements for the storage, transmission and distribution of hydrogen are reviewed in order to identify inadequacies to be corrected before hydrogen can achieve its full potential as a substitute for fossil fuels. Consideration is given to the storage of hydrogen in underground solution-mined salt caverns, portable high-pressure containers and dewars, pressure vessels and aquifers and as metal hydrides, hydrogen transmission in evacuated double-walled insulated containers and by pipeline, and distribution by truck and internal distribution networks. Areas for the improvement of these techniques are indicated, and these technological deficiencies, including materials development, low-cost storage and transmission methods, low-cost, long-life metal hydrides and novel methods for hydrogen storage, are presented as challenges for research and development.

Kelley, J. H.↗

Thermal energy storage for the Stirling engine powered automobile

A thermal energy storage (TES) system developed for use with the Stirling engine as an automotive power system has gravimetric and volumetric storage densities which are competitive with electric battery storage systems, meets all operational requirements for a practical vehicle, and can be packaged in compact sized automobiles with minimum impact on passenger and freight volume. The TES/Stirling system is the only storage approach for direct use of combustion heat from fuel sources not suitable for direct transport and use on the vehicle. The particular concept described is also useful for a dual mode TES/liquid fuel system in which the TES (recharged from an external energy source) is used for short duration trips (approximately 10 miles or less) and liquid fuel carried on board the vehicle used for long duration trips. The dual mode approach offers the potential of 50 percent savings in the consumption of premium liquid fuels for automotive propulsion in the United States.

Morgan, D. T.↗

Extended development of a sodium hydroxide thermal energy storage module

The post-test evaluation of a single heat exchanger sodium hydroxide thermal energy storage module for use in solar electric generation is reported. Chemical analyses of the storage medium used in the experimental model are presented. The experimental verification of the module performance using an alternate heat transfer fluid, Caloria HT-43, is described. Based on these results, a design analysis of a dual heat exchanger concept within the storage module is presented. A computer model and a reference design for the dual system (storage working fluid/power cycle working fluid) were completed. The dual system is estimated to have a capital cost of approximately one half that of the single heat exchanger concept.

Rice, R. E.↗

Parametric study of thermal storage containing rocks or fluid filled cans for solar heating and cooling, phase 2

The test data and an analysis of the heat transfer characteristics of a solar thermal energy storage bed utilizing water filled cans and standard bricks as energy storage medium are presented. This experimental investigation was initiated to find a usable heat intensive solar thermal storage device other than rock storage and water tank. Four different sizes of soup cans were stacked in a chamber in three different arrangements-vertical, horizontal, and random. Air is used as transfer medium for charging and discharge modes at three different mass flow rates and inlet air temperature respectively. These results are analyzed and compared, which show that a vertical stacking and medium size cans with Length/Diameter (L/D) ratio close to one have better average characteristics of heat transfer and pressure drop.

Saha, H.↗

Buffer thermal energy storage for an air Brayton solar engine

The application of latent-heat buffer thermal energy storage to a point-focusing solar receiver equipped with an air Brayton engine was studied. To demonstrate the effect of buffer thermal energy storage on engine operation, a computer program was written which models the recuperator, receiver, and thermal storage device as finite-element thermal masses. Actual operating or predicted performance data are used for all components, including the rotating equipment. Based on insolation input and a specified control scheme, the program predicts the Brayton engine operation, including flows, temperatures, and pressures for the various components, along with the engine output power. An economic parametric study indicates that the economic viability of buffer thermal energy storage is largely a function of the achievable engine life.

Strumpf, H. J.↗

On the inversion of block tridiagonals without storage constraints

A strategy was developed to permit trade-offs between the number of floating point operations required and the storage requirements for the solution of certain difference problems, such as block tridiagonal systems of equations. This is done by recomputing some intermediate results instead of storing them. Reducing the storage to the square root of the current requirement roughly doubles the number of computations. Reducing the storage more than this tends to make the number of computations prohibitively large. In theory, if m is the order of each sub-matrix in the block tridiagonal matrix, one can solve any linear system with only 5m(2) + 1 temporary storage cells. In many cases m is a constant and quite small. For example, in solving a factored form of the three-dimensional Navier-Stokes equations, the size m of the block tridiagonals is 5. This method lends itself to efficient use on computers with parallel processing or vector processing architectures. On these computers the larger number of floating point operations is more than offset by the decrease in I/O and the increased percentage of vector operations made possible by this algorithm.

Merriam, M. L.↗

Buffer thermal energy storage for a solar Brayton engine

A study has been completed on the application of latent-heat buffer thermal energy storage to a point-focusing solar receiver equipped with an air Brayton engine. To aid in the study, a computer program was written for complete transient/stead-state Brayton cycle performance. The results indicated that thermal storage can afford a significant decrease in the number of engine shutdowns as compared to operating without thermal storage. However, the number of shutdowns does not continuously decrease as the storage material weight increases. In fact, there appears to be an optimum weight for minimizing the number of shutdowns.

Strumpf, H. J.↗

Deposit formation in liquid fuels. I - Effect of coal-derived Lewis bases on storage stability of Jet A turbine fuel

The development of reasonably precise techniques for the measurement of storage stability of jet aviation fuel is described. Lewis bases, extracted by ligand-exchange from a coal-derived liquid, are shown to adversely affect storage stability (as determined by an accelerated storage test) when added to Jet A turbine fuel. JFTOT results suggesting slight decreases in thermal stability of fuel 'spiked' (i.e., contaminated with a measured quantity of reagent) with extract are reported. Addition to Jet A turbine fuel of individual heterocyclic nitrogen compounds is shown to produce comparable decreases in storage stability.

Dahlin, K. E.↗

Redox storage systems for solar applications

It is noted that the worldwide development of solar photovoltaic and wind turbine systems to meet a range of terrestrial electrical energy requirements has underscored the need for inexpensive and reliable electrical energy storage. The NASA Redox Energy Storage System, based on soluble aqueous iron and chromium chloride redox couples, has exhibited many system-related features which for the most part are unique to this storage system. The technology advances required in the two elements (electrodes and membranes), which are the key to its technological feasibility, have been attained and system development has begun. The design, construction, and testing of a 1-kW system integrated with a solar photovoltaic array is underway to provide early demonstration of the attractive system-related features of the NASA Redox Storage System. Also demonstrated will be its versatility and compatibility with a terrestrial solar photovoltaic electric power system.

Hagedorn, N. H.↗

Experimental simulation of latent heat thermal energy storage and heat pipe thermal transport for dish concentrator solar receiver

Test results on a modular simulation of the thermal transport and heat storage characteristics of a heat pipe solar receiver (HPSR) with thermal energy storage (TES) are presented. The HPSR features a 15-25 kWe Stirling engine power conversion system at the focal point of a parabolic dish concentrator operating at 827 C. The system collects and retrieves solar heat with sodium pipes and stores the heat in NaF-MgF2 latent heat storage material. The trials were run with a single full scale heat pipe, three full scale TES containers, and an air-cooled heat extraction coil to replace the Stirling engine heat exchanger. Charging and discharging, constant temperature operation, mixed mode operation, thermal inertial, etc. were studied. The heat pipe performance was verified, as were the thermal energy storage and discharge rates and isothermal discharges.

Narayanan, R.↗

Inertial storage for satellites

A new system is being developed that performs satellite attitude control, attitude reference, and energy storage utilizing inertia wheels. The baseline approach consists of two counter rotating flywheels suspended in specially designed magnetic bearings, spin axis motor/generators, and a control system. The control system regulates the magnetic bearings and spin axis motor/generators and interacts with other satellite subsystems (photovoltaic array, star trackers, Sun sensors, magnetic torquers, etc.) to perform the three functions. Existing satellites utilize separate subsystems to perform attitude control, provide attitude reference, and store energy. These functions are currently performed using reaction or momentum wheels, gyros, batteries, and devices that provide an absolute reference (Sun sensors and star trackers). A Combined Attitude, Reference, and Energy Storage (CARES) system based on high energy density inertial energy storage wheels (flywheels) has potential advantages over existing technologies. Even when used only for energy storage, this system offers the potential for substantial improvements in life, energy efficiency, and weight over existing battery technologies. Utilizing this same device for both attitude control and attitude reference would result in significant additional savings in overall satellite weight and complexity.

Eisenhaure, D.↗

Active cooling requirements for propellant storage

Recent NASA and DOD mission models have indicated future needs for orbital cryogenic storage and supply systems. Two thermal control systems which show the greatest promise for improving propellant storage life were evaluated. One system was an open cycle thermodynamic vent type with a refrigeration system for partial hydrogen reliquefaction located at the LH2 tank and a vapor cooled shield for integrated and non-integrated tank designs to reduce boiloff. The other was a closed system with direct refrigeration at the LH2 tank. A reversed Brayton cycle unit was baselined for the propellant processor. It is concluded that: (1) reliquefaction systems are not attractive for minimizing propellant boiloff; (2) open cycle systems may not be economically attractive for long term storage; (3) a number of refrigeration systems are available to assist in the long term storage of cryogenic propellants; and (4) shields can significantly improve the performance of mechanical coolers.

Klein, G. A.↗

Advanced long term cryogenic storage systems

Long term, cryogenic fluid storage facilities will be required to support future space programs such as the space-based Orbital Transfer Vehicle (OTV), Telescopes, and Laser Systems. An orbital liquid oxygen/liquid hydrogen storage system with an initial capacity of approximately 200,000 lb will be required. The storage facility tank design must have the capability of fluid acquisition in microgravity and limit cryogen boiloff due to environmental heating. Cryogenic boiloff management features, minimizing Earth-to-orbit transportation costs, will include advanced thick multilayer insulation/integrated vapor cooled shield concepts, low conductance support structures, and refrigeration/reliquefaction systems. Contracted study efforts are under way to develop storage system designs, technology plans, test article hardware designs, and develop plans for ground/flight testing.

Brown, Norman S.↗

Effect of storage and LEO cycling on manufacturing technology IPV nickel-hydrogen cells

Yardney Manufacturing Technology (MANTECH) 50 A-hr space weight individual pressure vessel nickel-hydrogen cells were evaluated. This consisted of investigating: the effect of storage and charge/discharge cycling on cell performance. For the storage test the cells were precharged with hydrogen, by the manufacturer, to a pressure of 14.5 psia. After undergoing activation and acceptance tests, the cells were discharged at C/10 rate (5A) to 0.1 V or less. The terminals were then shorted. The cells were shipped to NASA Lewis Research Center where they were stored at room temperature in the shorted condition for 1 year. After storage, the acceptance tests were repeated at NASA Lewis. A comparison of test results indicate no significant degradation in electrical performance due to 1 year storage. For the cycle life test the regime was a 90 minute low earth orbit at deep depths of discharge (80 and 60 percent). At the 80 percent DOD the three cells failed on the average at cycle 741. Failure for this test was defined to occur when the cell voltage degraded to 1 V prior to completion of the 35 min discharge. The DOD was reduced to 60 percent. The cycle life test was continued.

Smithrick, John J.↗

Long-term storage of nickel-hydrogen cells

Representative samples of nickel hydrogen cells for the INTELSAT program were used to evaluate the effects of prolonged storage under passive conditions such as open circuit discharged at 0 C, room temperature, and -20 C, and under quasidynamic conditions such as top-off charge and trickle charge. Cell capacity declines when cells are stored open-circuit discharged at room temperature, and a second plateau occurs in the discharge curve. Capacity loss was 47 percent for a cell with hydrogen precharge and 24.5 percent for one with no hydrogen precharge. Capacity recovery was observed following top-off charge storage of cells which had exhibited faded capacity as a result of passive storage at room temperature. Cells stored either at -20 C or on trickle charge maintained their capacity. At 0 C storage, the capacity of all three cells under tests was greater than 55 Ah (which exceeds the required minimum of 44 Ah) after 7 months.

Vaidyanathan, Hari↗

Effect of storage and LEO cycling on manufacturing technology IPV nickel-hydrogen cells

Yardney Manufacturing Technology (MANTECH) 50 A-hr space weight individual pressure vessel nickel-hydrogen cells were evaluated. This consisted of investigating: the effect of storage and charge/discharge cycling on cell performance. For the storage test the cells were precharged with hydrogen, by the manufacturer, to a pressure of 14.5 psia. After undergoing activation and acceptance tests, the cells were discharged at C/10 rate (5A) to 0.1 V or less. The terminals were then shorted. The cells were shipped to NASA Lewis Research Center where they were stored at room temperature in the shorted condition for 1 year. After storage, the acceptance tests were repeated at NASA Lewis. A comparison of test results indicate no significant degradation in electrical performance due to 1 year storage. For the cycle life test the regime was a 90 minute low earth orbit at deep depths of discharge (80 and 60 percent). At the 80 percent DOD the three cells failed on the average at cycle 741. Failure for this test was defined to occur when the cell voltage degraded to 1 V prior to completion of the 35 min discharge. The DOD was reduced to 60 percent. The cycle life test was continued.

Smithrick, John J.↗

An overview of selected information storage and retrieval issues in computerized document processing

The rapid development of computerized information storage and retrieval techniques has introduced the possibility of extending the word processing concept to document processing. A major advantage of computerized document processing is the relief of the tedious task of manual editing and composition usually encountered by traditional publishers through the immense speed and storage capacity of computers. Furthermore, computerized document processing provides an author with centralized control, the lack of which is a handicap of the traditional publishing operation. A survey of some computerized document processing techniques is presented with emphasis on related information storage and retrieval issues. String matching algorithms are considered central to document information storage and retrieval and are also discussed.

Dominick, Wayne D.↗