Search NASA⌕ Search

SEARCH · Search NASA

Results for “Storage Duration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Technical, economic, and load-following capabilities assessment of grid-connected geothermal and geothermal-solar hybrid systems

The technical and economic performance as well as the load-following capabilities of grid-connected geothermal hybrid systems were assessed in this work. The analyzed geothermal hybrid configuration is composed of a binary geothermal plant integrated with a concentrating solar-thermal system and underground thermal energy storage (UTES) through a primary heat exchanger. Physics-based models for the hybrid system for plant generation capacities of 1, 25, and 50 MW were developed from validated models for each subsystem. Also, an economic model was developed that accounts for different hybrid system capabilities, solar field sizes, and thermal storage duration. The advantage of the geothermal hybrid system was assessed by comparing the performance with the baseline benchmark geothermal plant with a similar configuration and generation capacity. It was found that hybridizing geothermal plants with concentrating solar and thermal energy storage not only improves the thermal efficiency by up to 8 percentage points when additional heat from the solar-UTES loop rises the evaporator temperatures from 70 to 125 °C, but also enhances the load-following capability for the geothermal plant, which can meet a typical residential load profile with a power rate of change 0.25 kW/s with an absolute error under 13 kW for a 1 MW plant. Other benefits of hybridization include resource preservation and a potential LCOE reduction of up to 56% for a 50 MW geothermal hybrid plant having a 50% solar share, a 1.4 solar multiple, and 24-h storage capacity. The results presented in this work demonstrate that hybridizing geothermal systems transforms them into a flexible and cost-effective solution for addressing the dynamic requirements of modern electric grids.

15 GEOTHERMAL ENERGY↗

Collaboration to Enable Higher Penetrations of Solar Power Generation Using the Natural Gas Pipeline System for Energy Storage (CRADA CRD-14-00567)

This unique project explored one possible solution for photovoltaic (PV) generation to become a reliable and dispatchable energy resource similar to conventional baseload fossil fuel electricity generation. Solar power generation is a renewable resource that varies naturally from day-to-day as well as seasonally. To use solar power as a baseload generation asset requires a flexible storage system that can recover power on both a daily and seasonal basis. Converting solar power to natural gas (i.e., first to hydrogen and then to methane) and having access to utility-scale storage in the natural gas network has the potential to make solar power generation a baseload asset. This will: 1) Increase the net energy yield from solar resources by increasing the effective capacity factor and maximize the energy produced during the assets’ lifetimes. 2) Improve the economics of energy storage for solar project developers, thereby accelerating the deployment of new solar generation. 3) Reduce the impact of increasing solar penetration on congestion of the electrical transmission system by shifting power delivery in time using the gas pipeline network for long-duration storage. 4) Reduce the impact of increasing solar generation on electrical distribution system control. 5) Offer alternative revenue sources for solar power generation beyond electricity including: hydrogen (H 2 ) production for stationary fuel cells and fuel cell electric vehicles, conversion of carbon dioxide (CO 2 ) to methane (CH 4 ) as a direct drop-in replacement for fossil natural gas use, and transmission as high volumetrically-dense CH 4 for use in transportation, heating, power generation, chemical production or conversion back to H2 at the point of use. Additional work was added to this CRADA in modification 4 having a primary objective to characterize the performance of the electrolyzer, Southern California Gas (SoCalGas) bioreactor and balance of plant to demonstrate production of renewable natural gas (RNG) from renewable H 2 and CO 2 using single-cell, self-replicating organisms. The additional scope of work allowed researchers to ramp up gas flowrates and pressure of the system over the designed range to grow the cells and begin to show the load-following capabilities of this anaerobic gas fermentation process. These activities enabled the research team to predict system performance at much greater scales; namely 10’s of mega-watts (MWs) of electrolyzer nameplate capacity.

14 SOLAR ENERGY↗

An Overview of NASA's In-Space Cryogenic Propellant Management Technologies

Future mission planning within NASA continues to include cryogenic propellants for in space transportation, with mission durations ranging from days to years. Between 1995 and the present, NASA has pursued a diversified program of ground-based testing to prepare the various technologies associated with in-space cryogenic fluid management (CFM) for implementation. CFM technology areas being addressed include passive insulation, zero gravity pressure control, zero gravity mass gauging, capillary liquid acquisition devices, and zero boiloff storage. NASA CFM technologies are planned, coordinated, and implemented through the Cryogenic Technology Working Group which is comprised of representatives from the various NASA Centers as well as the National Institute of Standards and Technologies (NIST) and, on selected occasions, the Air Force. An overview of the NASA program and Marshall Space Flight Center (MSFC) roles, accomplishments, and near-term activities are presented herein. Basic CFM technology areas being addressed include passive insulation, zero gravity pressure control, zero gravity mass gauging, capillary liquid acquisition devices, and zero boiloff storage. Recent MSFC accomplishments include: the large scale demonstration of a high performance variable density multilayer insulation (MLI) that reduced the boiloff by about half that of standard MLI; utilization of a foam substrate under MLI to eliminate the need for a helium purge bag system; demonstrations of both spray-bar and axial-jet mixer concepts for zero gravity pressure control; and sub-scale testing that verified an optical sensor concept for measuring liquid hydrogen mass in zero gravity. In response to missions requiring cryogenic propellant storage durations on the order of years, a cooperative effort by NASA's Ames Research Center, Glenn Research Center, and MSFC has been implemented to develop and demonstrate zero boiloff concepts for in-space storage of cryogenic propellants. An MSFC contribution to this cooperative effort is a large-scale demonstration of the integrated operation of passive insulation, destratification/pressure control, and cryocooler (commercial unit) subsystems to achieve zero boiloff storage of liquid hydrogen. Testing is expected during the Summer of 2001.

Tucker, Stephen↗

Lunar South Pole Illumination: Review, Reassessment, and Power System Implications

This paper reviews past analyses and research related to lunar south pole illumination and presents results of independent illumination analyses using an analytical tool and a radar digital elevation model. The analysis tool enables assessment at most locations near the lunar poles for any time and any year. Average illumination fraction, energy storage duration, solar/horizon terrain elevation profiles and illumination fraction profiles are presented for various highly illuminated sites which have been identified for manned or unmanned operations. The format of the data can be used by power system designers to develop mass optimized solar and energy storage systems. Data are presented for the worse case lunar day (a critical power planning bottleneck) as well as three lunar days during lunar south pole winter. The main site under consideration by present lunar mission planners (on the Crater Shackleton rim) is shown to have, for the worse case lunar day, a 0.71 average illumination fraction and 73 to 117 hours required for energy storage (depending on power system type). Linking other sites and including towers at either site are shown to not completely eliminate the need for energy storage.

Fincannon, James↗

Local-Scale Framework for Techno-Economic Analysis of Subsurface Hydrogen Storage

The energy sector is evolving toward increased reliance on renewable energy technologies to meet state, national, and organization decarbonization goals. This trend is creating challenges and opportunities with meeting current and future energy demand under the variable supply conditions that most renewables provide. Hydrogen (H 2 ) is a promising energy carrier that may meet the need for both on-demand and long-duration storage to maintain energy security and resilience. Underground hydrogen storage (UHS) is a method of storing H 2 in subsurface geological systems, such as depleted hydrocarbon reservoirs, salt caverns, saline aquifers, hard rock, and other engineered systems. UHS has the potential to store large quantities of H 2 over time, providing a reliable source of energy while minimizing surface footprints at a lower investment cost compared to surface storage. Earlier work estimated that, if converted and retrofitted, existing underground natural gas storage (UGS) facilities in the U.S. can store approximately 327 TWh, or 9.8 million metric tons, of pure H 2 . However, a shift to pure H 2 would decrease the collective working-gas energy of the UGS facilities by approximately 75% due to physical and chemical differences between natural gas and hydrogen. The same work also suggests that almost 75% of the existing UGS facilities in the U.S. could maintain current energy demand buffering using a blend of only 20% H 2 to 80% natural gas, by volume at surface conditions. If we can take advantage of the suite of mature technologies of existing UGS facilities and natural gas utility systems to accelerate the transition to a hydrogen economy in the U.S., a 20% H 2 blend could lead to a 6-7% reduction of greenhouse gas emissions for energy delivered through natural gas utility systems.

03 NATURAL GAS↗

Concrete Thermal Energy Storage Enabling Flexible Operation without Coal Plant Cycling

The work described in this report is responsive to the Office of Fossil Energy program “Energy Storage for Fossil Power Generation.” The pilot plant built as a result of this project demonstrated the feasibility and performance of a concrete thermal energy storage (CTES) system integrated with a supercritical coal power plant. The 10 MWh electrical (>25 MWh thermal) CTES unit, developed by Storworks Power, was designed to enable flexible operation of coal plants without cycling damage. The project's key technical achievements showcase a significant advancement in energy storage technology. A modular CTES system using 42 “Bolderblocs” units was successfully designed and constructed at Alabama Power’s Plant Gaston Unit 5, with each block containing embedded stainless-steel coils in specialized, cost-effective high-temperature concrete. The system interfaced seamlessly with the plant's 3500 psig (241 barg), 1000°F (538°C) supercritical steam, demonstrating operational flexibility. Over 86 full cycles, the CTES exhibited rapid charging and discharging capabilities, effectively mimicking steam turbine feed conditions and handling varying load profiles and storage durations. Performance validation confirmed the system's ability to consistently meet design target steam conditions of 75 bar-a and ~400°C for nominal baseline discharge. The concrete material withstood repeated thermal cycling without degradation, validating earlier lab-scale tests. Integration of balance of plant components, including a condensate management system with storage tank and air-cooled condenser, minimized plant interfaces and water consumption. A robust control scheme ensured safe, automated operation across various scenarios. Key learnings from the project were invaluable: 1. Initial concrete drying and commissioning procedures were refined for future deployments, enhancing efficiency in subsequent installations. 2. System flexibility exceeded expectations, with rapid response to changing conditions. 3. Design improvements were identified including optimized insulation and piping that will enhance overall system efficiency in future deployments 4. Full cycle thermal roundtrip efficiencies exceeded 88%. While the roundtrip electrical efficiency was somewhat limited by known challenges using input steam, such constraints may be mitigated by swapping steam for hot air as thermal input. 5. A summary of key performance parameters for the pilot test and predicted performance of a full scale commercial system with specified improvements determined from the pilot are shown in Section 8. The project faced challenges, including COVID-19 delays and host plant availability constraints. However, these were overcome through adaptive planning and execution. The successful management of these obstacles demonstrated the resilience and adaptability of the project team and the robustness of the CTES technology. This successful pilot demonstrates the potential for CTES to enhance coal plant flexibility, supporting grid stability as renewable penetration increases. The validated design and operational data provide a solid foundation for scaling up to utility-scale implementations, potentially transforming how thermal plants operate in evolving energy landscapes. The system's ability to rapidly respond to changing grid conditions while maintaining high efficiency makes it a promising solution for balancing intermittent renewable energy sources. Furthermore, the project highlighted the potential for even greater efficiencies in future iterations. The use of air as an input medium could potentially eliminate the limitations observed with steam input, opening new possibilities for energy storage applications beyond coal plant integration. In conclusion, this pilot project not only achieved its primary goals but also uncovered additional benefits and potential applications of the CTES technology. It represents a significant step forward in addressing the challenges of grid stability and flexibility in an increasingly renewable-driven energy landscape.

01 COAL, LIGNITE, AND PEAT↗

Valuation of Hydrogen Technology on the Electric Grid Using Production Cost Modeling: Cooperative Research and Development Final Report, CRADA Number CRD-18-00736

This research project will estimate the value to the United States electric grid of deploying hydrogen technology (such as electrolyzers and hydrogen-fueled generation) under projected conditions of high renewable penetration. The analysis will advance the state of the art in systems-level cost-benefit analysis of hydrogen technology for the electric grid by incorporating production cost modeling results in the analysis. Large-scale grid simulation tools will be used to evaluate total system production cost and grid operation when hydrogen technology is deployed for applications such as energy storage and demand response. Scenarios will include one or more future grid mixes in the Western Interconnect (WI) with a high proportion of intermittent renewables. Electric Power Research Institute (EPRI) will work with four utility companies to refine scenarios. Results of the analysis will include comparing the net cost of hydrogen to other technologies for long duration storage, and of power-to-gas (P2G) scenarios including merchant hydrogen sale and hydrogen-fueled generation.

08 HYDROGEN↗

Development of a Modular, Crushed-Rock Thermal Energy Storage Pilot Design

The goal of this project, primarily funded by the U.S. Department of Energy, is to design a next-step pilot to advance near-term energy storage integrated with a fossil plant to provide a facility capable of being viable and effective in a market with growing penetration of variable renewable energy (VRE). Thermal energy storage (TES) represents an ideal technology for this purpose. The current effort will complete a feasibility study to prepare for the Phase II pre-front end engineering design (pre-FEED) for implementing a crushed-rock TES system integrated with a natural gas combined cycle (NGCC) plant. The crushed rock storage technology, which is being developed by Brenmiller Energy, is a modular TES system termed bGen™, which can accommodate both thermal and electrical inputs and output steam, hot water, or hot air. For this application, the estimated efficiency is 80% thermal to thermal. The TES technology is being designed to operate on a slipstream from NYPA’s Eugene W. Zeltmann Power Project (Zeltmann) natural gas combined cycle (NGCC) plant. The projected size of the system will be up to 4 MWe with at least 4 hours of storage duration, or 16 MWh-e total. Final sizing is being determined during the ongoing feasibility study. The next-step pilot being designed as part of the current project will represent a 5-fold increase in scale for this TES technology, and will be used to validate the technology’s ability to provide effective and economical energy storage. This pilot would represent the next-to-last demonstration scale before the technology could be commercial ready at GWh-e scales in the 2030 timeframe. This project is expected to design the critical next-step pilot, which will be undertaken in real-world operating conditions to better determine the crushed rock TES technology’s ability to be integrated with an NGCC plant and assess degradation over transient cycling at rates befitting various marketplaces. The crushed-rock TES pilot design is a technically feasible next step in the development of the technology and is built upon years of prior testing and demonstration. The proposed TES technology was developed by Brenmiller over the last 8 years and has been tested in 3 generations of demonstration units at various sites, globally. During this field testing, different characteristics and performance of the technology were validated, including the following key features: energy storage capacity, energy storage charge/discharge rate, energy storage loses, energy storage mechanical testing. This presentation will provide an update on the results of the conceptual design study for the modular crushed-rock TES system, integrated with a NGCC power plant.

03 NATURAL GAS↗

JV Task 119 - Effects of Aging on Treated Activated Carbons

For both the United States and Canada, testing has been under way for electric utilities to find viable and economical mercury control strategies to meet pending future mercury emission limits. The technology that holds the most promise for mercury control in low-chlorine lignite to meet the needs of the Clean Air Act in the United States and the Canada-Wide Standards in Canada is injection of treated activated carbon (AC) into the flue gas stream. Most of the treated carbons are reported to be halogenated, often with bromine. Under a previous multiyear project headed by the Energy & Environmental Research Center (EERC), testing was performed on a slipstream unit using actual lignite-derived flue gas to evaluate various sorbent technologies for their effectiveness, performance, and cost. Testing under this project showed that halogenated ACs performed very well, with mercury capture rates often {ge} 90%. However, differences were noted between treated ACs with respect to reactivity and capacity, possibly as a result of storage conditions. Under certain conditions (primarily storage in ambient air), notable performance degradation had occurred in mercury capture efficiency. Therefore, a small exploratory task within this project evaluated possible differences resulting from storage conditions and subsequent effects of aging that might somehow alter their chemical or physical properties. In order to further investigate this potential degradation of treated (halogenated) ACs, the EERC, together with DOE's National Energy Technology Laboratory, the North Dakota Industrial Commission (NDIC), the Electric Power Research Institute (EPRI), SaskPower, and Otter Tail Power Company, assessed the aging effects of brominated ACs for the effect that different storage durations, temperatures, and humidity conditions have on the mercury sorption capacity of treated ACs. No aging effects on initial capture activity were observed for any carbons or conditions in the investigation. As measured by the 50% breakthrough time, no changes in capacity were observed for Norit LH samples stored frozen and likely none for Norit LH samples stored under high humidity conditions. The major aging effects on capacity for the EERC brominated sample were seen as a decrease in capacity during the first week of storage under high humidity conditions. Storage of the Norit LH and the EERC 5% brominated samples under low humidity conditions resulted in slightly improved capacities. Storage of the 15% brominated sample under high humidity conditions also improved the capacity. Surface analysis using x-ray photoelectron spectroscopy (XPS) showed some migration of bromine to and from the surface occurred during storage, although no net loss of bromine was observed. The migration to the surface in the case of the 15% brominated carbon correlates with the increased capacity observed for this sample. The XPS elemental speciation data for the EERC brominated carbons showed a trend toward more bromide being formed at the expense of covalent bromine during storage. This was especially great for the 15% and the 5% stored in low humidity. The Norit LH samples did not show this increase in bromide concentration. This is consistent with the lack of change in capacity for the Norit LH during storage. The carbon speciation data showed generally more oxidization of carbon surfaces with storage, especially formation of carboxylate groups. The least increase in carboxylate groups was seen for the Norit LH stored under low humidity, which correlates with its increased capacity. In conclusion, the observed changes in surface chemistry can be related to the minimal changes in capacity observed, but the factors operate in different directions, so the relationships are complex. High-quality x-ray absorption fine structure spectra were obtained for most of the samples. Significant changes were observed in the x-ray absorption near edge structure and extended x-ray absorption fine structure spectra of the stored carbons, but proved difficult to interpret and correlate with structural changes.

01 COAL, LIGNITE, AND PEAT↗

Energy and Power Evolution Over the Lifetime of a Battery

Li-ion batteries currently are dominant energy storage devices for electric vehicles. Rechargeable batteries with lower cost, longer lifetime, and higher safety are desired in support of building of a green grid infrastructure. The continued investment in new battery materials, novel battery structures, advanced manufacturing processes, and accelerated testing/validation of battery performance has led to significant progress in battery development and deployment. Battery safety/reliability, which is essential to the success of a battery technology in the real world, naturally becomes the next big topic in battery research. Recently, the increasing interest in long-duration storage, fast charging, battery secondary use, and material recycling to build a circular industry and sustainable material supply chain has compelled further attention to understand the energy/power evolution and safety over the lifetime of a battery. Here, in this short Viewpoint, we discuss some high-level analyses on the energy/power evolution of rechargeable batteries over their life cycles aiming to inspire more discussion on the safety and sustainability of some representative and emerging battery technologies.

25 ENERGY STORAGE↗

Modular, Crushed-Rock Thermal Energy Storage Pilot Design (Final Report)

The goal of this project was to design a next-step pilot to advance near-term energy storage integrated with a fossil plant to provide a facility capable of being viable and effective in a market with growing penetration of variable renewable energy (VRE). Thermal energy storage (TES) represents an ideal technology for this purpose. The completed effort included a feasibility study to prepare for the Phase II pre-front end engineering design (pre-FEED) for implementing a crushed-rock TES system integrated with a natural gas combined cycle (NGCC) plant. The crushed rock storage technology, which is being developed by Brenmiller Energy, is a modular TES system termed bGen™, which can accommodate both thermal and electrical inputs and output steam, hot water, or hot air. For this application, the estimated efficiency is 80% thermal to thermal. For the feasibility study, the Brenmiller technology was designed to operate on a slipstream from NYPA’s Eugene W. Zeltmann Power Project (Zeltmann) NGCC plant in Astoria, New York. The projected size of the system will be up to 4 MWe with at least 4 hours of storage duration, or 16 MWh-e total. The study also included a techno-economic evaluation of a 200 MWh commercial-scale demonstration. Prior to this project, EPRI had reviewed Brenmiller’s technology, which is being built to demonstrate bGen™ at 1.7 MWe on a solar plant (Rotem) and has been designed for an NGCC facility in Italy, assessing it at technology readiness level (TRL) 5. Brenmiller is also conducting a separate 1-MWth pilot with NYPA that pairs a bGen™ module with a microturbine for a combined-heat-and-power (CHP) application to improve efficiency and provide flexibility. The next-step pilot being designed as part of this project would represent a 5-fold increase in scale, versus Rotem, and would show the technology’s ability to provide effective and economical energy storage, bringing the technology to TRL 6. This pilot would represent the next-to-last demonstration scale before the technology could be commercial ready at GWh-e scales in the 2030 timeframe. The main objective of the work completed by the Electric Power Research Institute, Inc. (EPRI), Brenmiller Energy (Brenmiller), New York Power Authority (NYPA), and United E&C (formerly AECOM) was to perform a Phase I feasibility study on the integration of a crushed-rock thermal energy storage (TES) with a fossil plant. Under this project, the EPRI-led team successfully completed a feasibility study to prepare for the potential future Phase II pre-front end engineering design (pre-FEED) to implement a crushed-rock TES system integrated with a natural gas combined cycle (NGCC) plant. Specific deliverables under this project included the Technology Maturation Plan, Conceptual Study, Techno-Economic Assessment, Technology Gap Assessment, Project Plan for Phase II (submitted as Phase II Renewal Application), Commercialization Plan, and the Final Report (this document). This Final Report includes a compilation of the various summary reports that were prepared during the 12-month schedule of the Phase I project execution under award DE-FE0032017.

03 NATURAL GAS↗

Africa Battery Energy Storage Systems (BESS) Capacity Building Utility-Scale Storage: BESS Valuation, Tariffs, and Remuneration [Slides]

Utility-scale Battery Energy Storage Systems (BESS) are key to enhancing grid reliability, integrating renewable energy, and providing operational flexibility. Designing effective valuation, remuneration, and tariff frameworks is essential to ensure both system benefits and financial viability for developers. This presentation outlines a structured methodology for evaluating BESS projects, covering policy and legal considerations, cost and revenue analysis, benchmarking, financial sensitivity, and risk assessment, while ensuring alignment with public interest. It also explores valuation of multiple storage services - bulk energy, ancillary services, and infrastructure support - and monetization strategies through capacity payments, energy tariffs, tolling, arbitrage, and non-wires alternative payments. Technical factors, including round-trip efficiency, degradation, and storage duration, are integrated into financial and operational modeling to quantify both system-wide and project-level benefits. Through case studies and simulation-based approaches, this framework provides regulators, utilities, and developers with practical guidance for tariff design, payment structures, and investment decisions, maximizing the economic and societal value of BESS deployment.

25 ENERGY STORAGE↗

Spent Nuclear Fuel Exploratory Roadmaps - 20054

The U.S. Department of Energy manages nearly 2,500 metric tons of heavy metal (MTHM) of spent nuclear fuel (SNF) resulting from several decades of research, testing, and production reactors [DOE 1995]. This SNF is managed at the DOE Hanford Site in Washington State (Hanford), Idaho National Laboratory (INL), and Savannah River Site in South Carolina (SRS). From 1995 to 2004, the Department of Energy (DOE) made several key programmatic decisions, supported by appropriate documentation in accordance with the National Environmental Policy Act (NEPA) for the management of SNF [DOE 1995]. These decisions have provided an overarching framework for SNF management, as well as site-specific and SNF-related management decisions for the past two decades. In the years since these decisions were made, with the notable exception of the successful drying and packaging of the production reactor fuel at Hanford, a majority of the decisions have been largely unimplemented. Also, since these decisions were made, a number of changes that bear on considerations relative to the path forward have occurred. A SNF Exploratory Road map activity, identified reasonable alternate pathways for DoE's inventory of SNF. Three fundamental pathways were identified in this activity for the long-term management and disposition of DOE SNF: Direct Disposal Pathway, Existing Processing Pathway and Alternate Processing Pathway. Further actions would be required (e.g., evaluation of NEPA analysis, technology maturity evaluations, refinement of cost and risks, benefits and advantages relative to other alternate paths) to define and inform many key decisions that will result in the selection of the disposition pathways that are most beneficial to the US Government in dispositioning DoE's SNF inventory. DOE is currently managing all SNF safely; however, the age of DOE-owned SNF and facilities for storing and processing SNF, coupled with the uncertainty of the storage duration, necessitates decisions and actions to ensure that the infrastructure will be in place to ensure continued safe and effective long-term management and eventual disposal. The identification of reasonable alternate pathways took these considerations into account in an effort to proactively manage conditions that could challenge the safety of storing and managing DOE SNF over the time periods now contemplated and also to ensure that flexibility is preserved to ensure that the DOE SNF remains compatible with final disposition pathways when they become available. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

System Design of a 2.0 MWth Sodium/Molten Salt Pilot System

Nitrate molten salt concentrating solar power (CSP) systems are currently deployed globally and are considered state-of the art heat transfer fluids (HTFs) for present day high-temperature operation. Although slightly higher limits may be possible with molten salt, to fully realize SunShot efficiency goals of $15/kWhth HTFs and an LCOE of 6¢/kWh, HTF technologies working at higher temperatures (e.g., 650 °C to 750 °C) will require an alternative to molten salts, such as with alkali metal systems. This investigation explores the development of a 2.0 MWth sodium receiver system that employs a sodium receiver as the HTF, as well as with a ternary chloride (20%NaCl/40%MgCl/40%KCl by mol wt.%) salt as a thermal energy storage (TES) medium to facilitate a 6-hr. storage duration. A sodium-to-salt heat exchanger model as well as a salt-to-sCO2 primary heat exchanger model are employed and evaluated in this investigation. A thermodynamic system design model was developed using Engineering Equation Solver (EES) where state properties were calculated at inlets and outlets along both hot and cold legs of the pilot-scale plant. This investigation assesses receiver performance as well as system efficiency studies for the pump and system operational ranges. Results found that high efficiency sodium receivers were found to have higher heat transfer coefficients and required far less spreading of incident flux. The system performance model results suggest that for a pump speed of 2400 RPM, respective hot and cold pump TDH values were determined to be 260.1–307 ft. and 260.1–307 ft for pump flow rates of 90–120 GPM.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Operational Parameter Database for Molten Salt Thermal Energy Storage Tank Modeling

The second generation of concentrated solar power (CSP) plants is characterized by the use of a central receiver (either cavity or external), two molten nitrate salt tanks (60 wt.% NaNO 3 and 40 wt.% KNO 3 ), and a steam Rankine power-generation cycle connected through a primary heat exchanger. Molten salt thermal energy storage (TES) tanks have been widely deployed in commercial CSP plants worldwide and have been essential for increasing plant dispatchability and capacity factor, while also reducing the levelized cost of electricity (LCOE). These systems enable energy storage at the gigawatt-hour scale, typically providing 6 to 17 hours of storage duration. Despite being a commercial technology, the multiple failures observed after only a few months or years of operation in plants around the world demonstrate the technology's relative infancy and highlight the need for further research to improve its reliability. The National Laboratory of the Rockies (NLR), in collaboration with industry partners and academic and research institutions, has been leading multiple projects funded by the U.S. Department of Energy (DOE). These projects focus on addressing molten salt tank failures by improving tank design and welding fabrication practices, evaluating new alloys and weld fillers, and providing guidelines for tank commissioning and safe operation. In particular, this report presents modeling results on the effect of key tank operation parameters during 60 minutes of operation, including the mass flow rate and temperature of the salt inflow, tank salt inventory temperature, and inventory level for a representative molten salt tank design. These results form a database of tank operation behaviors that captures the effects of each specific parameter during charging, charging/discharging, and discharging processes.

14 SOLAR ENERGY↗

Nephrotoxicity of uranium in drinking water from private drilled wells

Objectives: To investigate the association between uranium in drinking water from drilled wells and aspects of kidney function measured by sensitive urine tests. Methods: Three hundred and one of 398 eligible subjects (75.6%) aged 18-74 years with daily drinking water supplies from private drilled wells located in uranium-rich bedrock (exposed group) volunteered to participate along with 153 of 271 local controls (56.4%) who used municipal water. Participants responded to a questionnaire on their water consumption and general health, and provided a morning urine sample and drinking water for analysis. Results: The uranium content of well water samples (n=153) varied considerably (range <0.20-470 {mu}g/l, median 6.7 {mu}g/l, 5% >100 {mu}g/l), while uranium levels in all samples of municipal water (n=14) were below the limit of quantification (0.2 {mu}g/l). Urinary levels of uranium were more than eight times higher in exposed subjects than in controls (geometric means 38 and 4.3 ng/l, respectively; p<0.001), but their mean urine lead levels were not significantly different. There was a strong curvilinear correlation between uranium in drinking water and in urine (r{sup 2}=0.66). Levels of albumin, {beta}{sub 2}-microglobulin, protein HC as well as kappa and lambda immunoglobulin chains in urine from exposed and controls were similar. The N-acetyl-{beta}-D-glucosaminidase (NAG) activity was significantly lower in the exposed group vs. controls, possibly secondary to differential storage duration of samples from the two groups. Even in regression models adjusting for gender, age and smoking no association of uranium in water and the kidney function parameters was observed. Using uranium in urine in the entire study group as a marker of exposure, however, a tendency of exposure-related increases of {beta}{sub 2}-microglobulin, protein HC and kappa chains were noted. This tendency was enhanced after exclusion of subjects with diabetes mellitus from the analysis. Conclusions: Uranium levels in urine were strongly correlated to levels in drinking water from drilled wells. There were no clear signs of nephrotoxicity from uranium in drinking water at levels recorded in this study, but some indications of an effect were observed using uranium in urine as a measure of overall uranium exposure. The clinical relevance of these findings remains unclear.

60 APPLIED LIFE SCIENCES↗

Amorphous ZnAlSnO thin-film transistors by a combustion solution process for future displays

A combustion solution method was developed to fabricate amorphous ZnAlSnO (a-ZATO) for thin-film transistors (TFTs). The properties of a-ZATO films and behaviors of a-ZATO TFTs were studied in detail. An appropriate Al content in the matrix could suppress the formation of oxygen vacancies efficiently and achieve densely amorphous films. The a-ZATO TFTs exhibited acceptable performances, with an on/off current ratio of ∼10{sup 6}, field-effect mobility of 2.33 cm{sup 2}·V{sup −1}·S{sup −1}, threshold voltage of 2.39 V, and subthreshold swing of 0.52 V/decade at an optimal Al content (0.5). The relation between on- and off-resistance of the ZATO TFT was also within the range expected for fast switching devices. More importantly, the introduced Al with an appropriate content had the ability to evidently enhance the device long-term stability under working bias stress and storage durations. The obtained indium- and gallium-free a-ZATO TFTs are very promising for the next-generation displays.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Geographical variability of summer- and winter-dominant onshore wind

For each geographical region, one of the biggest challenges in reaching a zero-carbon grid is identifying sources of electricity that match the seasonal profile of the load. Summer-dominant solar electricity generation can often be balanced by winter-dominant wind electricity generation. Together with long-duration storage, balanced solar and wind generation are well positioned to provide reliable renewable electricity. However, in some locations the wind may not complement solar energy so well. For example, currently California's wind turbines produce more electricity during summer than winter, raising the question of whether all future wind plants in California will exhibit the same seasonality. As a response to this question, in this paper, we analyzed the generation from existing California wind plants and simulated potential onshore wind resource for the whole state using a metric that reflects the relative wind resource in winter. Our results indicate that the seasonality of the wind can vary for very small spatial difference with more than half of California showing stronger wind resource in the winter compared with the summer despite the current observation of the opposite trend. This study differentiates the seasonality of potential wind resources to inform the creation of a reliable, 100%-renewable-driven grid.

17 WIND ENERGY↗