Search NASASearch

SEARCH · Search NASA

Results for “Stream or ponded width measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

644 records · Page 10

Reducing experimental uncertainty in the calculation of cavity swelling in a transmission electron microscope through crystallographically aided void volume tracking

Accurate measurement of cavity swelling in a transmission electron microscope is essential to define material performance under irradiation, and the conventionally applied spherical assumption for the calculation of cavity volumes in irradiated materials can result in errors ranging between a 25% underestimation and 72% overestimation of volume purely based on the assumption of shape. This assumption is undeniably expedient for calculation but does not sufficiently account for the 3D nature of polyhedral cavities and their shape projection in the transmission electron microscope, and therefore presents too large of an associated uncertainty in swelling determination for faceted cavities. This uncertainty has been defined for many common cavity shapes in FCC and BCC crystal systems, and has been tabulated across the cubic fundamental region. A revised methodology for crystallographically aided void volume tracking, or CAVV-T, is presented and demonstrated on a specimen of neutron irradiated Ni. In-depth discussion on the application of this technique is provided along with resources to allow for conversion between the spherical assumption and this revised method. This work seeks to increase experimental confidence in the characterization and quantification of critical aspects of irradiation damage in materials by applying a crystallographically-resolved approach for cavity swelling calculation.

Haag IV, James V. [Pacific Northwest National Labo

Electron-Deficient Phenazines: Synthesis, Structures, Redox, and Optoelectronic Properties in the Gas Phase, in Solution, and in the Solid State

High-temperature gas-phase reactions of 1,4-C4F8I2 with phenazine (PHNZ) afforded new thermally- and air-stable derivatives with cyclo-C4F8 substituents, viz. 1,2-PHNZ(C4F8), 2,3-PHNZ(C4F8), 1,2:6,7-PHNZ(C4F8)2, 1,2:7,8-PHNZ(C4F8)2, and 1,2:8,9-PHNZ(C4F8)2. Reactions in the presence of Cu powder resulted in reductive-defluorination/aromatization of some of the cyclo-C4F8 substituents to produce 2,3-PHNZ(C4F4), 2,3-PHNZ(C4HF3), and 1,2:6,7-PHNZ(C4F8)(C4F4), which are formally tri- or tetrafluoro derivatives of benzo[a]phenazine. Single-crystal X-ray diffraction structures of these compounds demonstrate the planarity of 2,3-PHNZ(C4F4) and 2,3-PHNZ(C4HF3) and ordered p-stacking in 1,2-PHNZ(C4HF3), 1,2-PHNZ(C4F4), 1,2-PHNZ(C4F8), and 2,3-PHNZ(C4F8). Low-temperature gas-phase photoelectron spectra of the PHNZ(C4F8)1,2 compounds show that they are strong electron acceptors, with the three PHNZ(C4F8)2 isomers having electron affinities exceeding that of C60. Cyclic voltammetry in acetonitrile show that the five PHNZ(C4F8)1,2 compounds exhibit reversible one-electron reductions with large positive shifts in their reduction potentials relative to unsubstituted PHNZ. Spectroelectrochemical absorption and EPR spectra of PHNZ(C4F8)1,2- • anion radicals and extensive DFT calculations revealed the significant role that the different substitution patterns have on determining the optoelectronic properties of the PHNZ(C4F8)1,2 derivatives and PHNZ(C4F8)1,2- • anion radicals. Time-resolved microwave conductivity measurements and photoluminescence spectra of blends of the PHNZ(C4F8)1,2 derivatives with the donor poly(3-hexylthiophene) (P3HT) were recorded to assess the possible use of the new compounds in optoelectronic devices.

Balser, Sebastian

A multi-region approach for the analysis of porous materials and gas-solid reactions using USAXS-SAXS-WAXS: application to CaO carbonation

The reaction rate of gas-solid non-catalytic reactions is typically investigated using reactant conversion data over time and ex-situ measurements of the porous solid reactant textural properties; these data enable the experimental estimation of the initial intrinsic reaction rate, whereas the evolution of the textural properties and the reaction rate over time are evaluated theoretically using reaction models. In this work, a different methodology is presented, based on: a) in-situ time-resolved USAXS-SAXS-WAXS measurements of the solid sample, and b) a multi-region modeling approach; this methodology allows for the estimation of the textural properties and the intrinsic reaction rate at any time during the reaction. Referring to a reaction in which a solid product is obtained from a solid reactant and a gaseous reactant, the porous particle is described as consisting of several distinct regions with different microstructural properties, and both a gas-solid reaction model and a SAXS model are derived and applied to the carbonation of porous CaO. The proposed reaction model highlights the role of the inaccessible reactant and accurately predicts the solid reactant conversion versus time profile. The SAXS model accurately predicts the measured linear trends of the Porod invariant and of the pre-factor of the power law scattering profile versus CaO mass fraction; in the absence of chemical reactions, the proposed equations extend classical SAXS theory to porous materials containing macropores and nonporous solid phases in addition to standard nanoscale inhomogeneous regions.

CO2 solid sorbents

The effect of dogbone sample size in the tensile testing of TATB-based plastic‑bonded explosive materials

Mechanical properties are of interest for many plastic‑bonded explosive (PBX) materials with tensile properties being of particular interest. Direct tensile measurements using dogbone-shaped samples are considered the gold standard, but they are fairly large, making testing more costly and less desirable from a safety perspective. We investigated whether the measured tensile strength depends on the dogbone specimen size, which to our knowledge, has not been reported in the literature for PBX materials. Understanding this should inform the feasibility of employing smaller samples and how sample size should be considered when comparing PBX dogbone values in the literature. The TATB-based PBX dogbone sample size was varied by (a) scaling all dimensions proportionally and (b) varying only the length of the samples. It was observed that the measured tensile peak stress (strength) was a function of the sample size, and was more dependent on the diameter (cross-sectional area) than the length of the samples. Since peak stress is calculated as peak force normalized to the diameter of the sample, one might not expect an explicit diameter dependence for the peak stress. Therefore, these results suggest there may be an additional strengthening effect as the sample diameter is increased.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Method and apparatus for providing thermal wear leveling

Exemplary embodiments provide thermal wear spreading among a plurality of thermal die regions in an integrated circuit or among dies by using die region wear-out data that represents a cumulative amount of time each of a number of thermal die regions in one or more dies has spent at a particular temperature level. In one example, die region wear-out data is stored in persistent memory and is accrued over a life of each respective thermal region so that a long term monitoring of temperature levels in the various die regions is used to spread thermal wear among the thermal die regions. In one example, spreading thermal wear is done by controlling task execution such as thread execution among one or more processing cores, dies and/or data access operations for a memory.

Roberts, David A.

Ductless Heat Pump Program

The Verde Ductless Heat Pump (DHP) Program expanded access to high-efficiency electric heating and cooling technologies for households in priority communities within the Portland Metro area. Funded by the U.S. Department of Energy’s Building Technologies Office (DE-EE0010132), the program combined residential ductless heat pump deployment with community-based outreach, participant support, contractor partnerships, and system development to improve program delivery.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Electric spiking activity in epithelial cells

Epithelial cells (human keratinocyte cells and the canine MDCK cell line), traditionally viewed as electrically non-self-excitable and involved primarily in physiological functions such as barrier presentation, absorption, secretion, and protection, are shown here to exhibit traveling extracellular electric charge when they recover from spatially focused, laser-induced wounding of confluent monolayers cultured on a multielectrode array chip. Voltage spikes measured on these electrodes display depolarization, repolarization, and hyperpolarization phases with amplitudes similar to the action potentials of neurons but with the markedly slower duration of 1 to 2 s. Some propagate distances up to hundreds of μm from the wound with a mean speed of around 10 mm s −1 . Generation and transmission of bioelectric signals are significantly influenced by the perturbation of mechanosensitive cationic ion channels. These direct measurements confirm bioelectric signaling that previous work has hypothesized to regulate epithelial cell development and may have relevance to the frequency parameter selection of bioelectric devices.

Science & Technology - Other Topics

The Future Polarized Target Program at Jefferson Lab

Polarized targets have played a crucial role in Jefferson Lab's exploration of nuclear structure over the past four decades. The three original experimental halls have seen 19 separate installations of polarized solid or gas targets for use in the particle physics scattering experiments, and this trend will continue in the next decade. Five polarized target systems are in preparation for use at JLab in the coming years. Hall B will see the use of two solid polarized targets, one longitudinally polarized to the beam, the other transversely, as well as a novel 3He gas polarized target. In Hall C, new experiments will augment the tensor polarization in dynamically polarized solids. Plans are under development to bring a polarized solid target to Jefferson Lab's photon beam hall, Hall D, for the first time. To support these efforts, the JLab polarized target group is building a test laboratory to develop dynamic nuclear polarization techniques, as well as an apparatus to irradiate target material using electrons from JLab's injector test facility. In this talk, we will explore the development progress and plans for each of these efforts.

Maxwell, James [Thomas Jefferson National Accelera

The role of fast and slow dynamics in nonlinear resonant ultrasound spectroscopy of consolidated granular materials

Abstract Elastic nonlinearity observed in consolidated granular media can be attributed to the combination of slow and fast effects, which give rise to hysteresis and relaxation of both modulus and damping after the sample is perturbed. A consequence is a high level of complexity in the measurements of the sample linear and nonlinear elastic parameters. The results of experiments are dependent on the experimental protocol that is adopted to measure the relevant quantities and it is hard to quantify parameters with accuracy and repeatability. Here we focus on examining Nonlinear Resonant Ultrasound Spectroscopy, showing experimentally the role of slow dynamics in the process and quantifying/discussing its influence on the quantification of nonlinearity. We also propose a model to describe the process, which shows that different contributions to nonlinearity (e.g., classical and hysteretic) could be due to physical features (defects) relaxing with different relaxation times.

Science & Technology - Other Topics

Zero-field J-spectroscopy of quadrupolar nuclei

Abstract Zero- to ultralow-field nuclear magnetic resonance (ZULF NMR) allows molecular structure elucidation via measurement of electron-mediated spin-spinJ-couplings. This study examines zero-fieldJ-spectra from molecules with quadrupolar nuclei, exemplified by solutions of various isotopologues of ammonium cations. The spectra reveal differences between various isotopologues upon extracting preciseJ-coupling values from pulse-acquire measurements. A primary isotope effect,$$\triangle J=\left({\gamma }_{{}^{14}{{{{{\rm{N}}}}}}}/{\gamma }_{{}^{15}{{{{{\rm{N}}}}}}}\right){J}_{{}^{15}{{{{{\rm{N}}}}}}{{{{{\rm{H}}}}}}}-{J}_{{}^{14}{{{{{\rm{N}}}}}}{{{{{\rm{H}}}}}}}\approx -58$$ △ J = γ 14 N / γ 15 N J 15 N H − J 14 N H ≈ − 58 mHz, is deduced by analysis of the proton-nitrogenJ-coupling ratios. This study points toward further experiments with symmetric cations containing quadrupolar nuclei, promising applications in biomedicine, energy storage, and benchmarking quantum chemistry calculations.

Science & Technology - Other Topics

Cully Community Solar

This report summarizes the outcomes, accomplishments, challenges, and lessons learned from Verde’s Cully Community Solar project, funded by the U.S. Department of Energy’s Solar Energy Technologies Office. The project focused on advancing community solar development through engineering, permitting, interconnection, ecological site design, workforce development, and community engagement. During the project period, Verde and its partners successfully developed and commissioned a 1.25 MW ground-mounted community solar system while also advancing planning for additional community solar capacity and developing approaches that can inform future projects in complex urban environments.

14 SOLAR ENERGY

The DESI Single Fiber Lens Search. I. Four Thousand Spectroscopically Selected Galaxy–Galaxy Gravitational Lens Candidates

We present 4110 strong gravitational lens candidates, 3887 of which are new discoveries, selected from a sample of 5,837,154 luminous red galaxies (LRGs) observed with the Dark Energy Spectroscopic Instrument (DESI). Candidates are identified via the presence of background ionized oxygen [O II ] nebular emission lines in the foreground LRG spectra, which may originate from the lensing of higher-redshift star-forming galaxies. Using the measured foreground redshift, background redshift, and integrated flux of the background [O II ] doublet, we integrate over impact parameters to compute the probability that each candidate is a lens. We expect 53% of candidates to be true lenses with Einstein radii ranging from 0$^{''}_.$1–4", which can be confirmed with high-resolution imaging. Confirmed strong lenses from this sample will form a valuable cosmological data set, as strong gravitational lensing is the only method to directly measure dark matter halo substructure at cosmological distances. We independently recover the host of the multiply imaged gravitationally lensed type Ia supernova iPTF16geu. Monitoring these lenses for future multiply lensed transients will enable (a) H 0 measurements via time-delay cosmography and (b) substructure measurements via flux ratios.

Karp, Juliana S. M. [Univ. of Washington, Seattle,

The SPT-deep Cluster Catalog: Sunyaev–Zel’dovich Selected Clusters from Combined SPT-3G and SPTpol Measurements over 100 Square Degrees

We present a catalog of 500 galaxy cluster candidates in the SPT-Deep field: a 100 deg$^{2}$ field that combines data from the SPT-3G and SPTpol surveys to reach noise levels of 3.0, 2.2, and 9.0 μK-arcmin at 95, 150, and 220 GHz, respectively. Candidates are selected via the thermal Sunyaev–Zel’dovich (SZ) effect with a minimum significance of ξ = 4.0, resulting in a catalog of purity ∼89%. Optical data from the Dark Energy Survey and infrared data from the Spitzer Space Telescope are used to confirm 442 cluster candidates. The clusters span 0.12 < z ≲ 1.8 and 1.0 × 10$^{14}$M$_{⊙}$/h$_{70}$ < M$_{500c}$ < 8.7 × 10$^{14}$M$_{⊙}$/h$_{70}$. The sample’s median redshift is 0.74, and the median mass is 1.7 × 10$^{14}$M$_{⊙}$/h$_{70}$; these are the lowest median mass and highest median redshift of any SZ-selected sample to date. We assess the effect of infrared emission from cluster member galaxies on cluster selection by performing a joint fit to the infrared dust and tSZ signals by combining measurements from SPT and overlapping submillimeter data from Herschel/SPIRE. We find that at high redshift (z > 1), the tSZ signal is reduced by $17.9_{−3.2}^{+3.8}$%$(3.8_{−0.7}^{+0.9}$%$)$ at 150 GHz (95 GHz) due to dust contamination. We repeat our cluster finding method on dust-nulled SPT maps and find the resulting catalog is consistent with the nominal SPT-Deep catalog, suggesting dust contamination does not significantly impact the SPT-Deep selection function; we attribute this lack of bias to the inclusion of the SPT 220 GHz band.

79 ASTRONOMY AND ASTROPHYSICS

Gating ion and fluid transport with chiral solvent

Nonlinear spectroscopy and electrokinetic measurements reveal that the electrochemical properties of a solid–liquid interface in salt solutions in propylene carbonate are dependent on the solvent chirality.

Chemistry

Uncovering Hidden Entanglement in Twin Beams

Proper characterization of quantum correlations in multimode optical quantum states is critical for applications in quantum information science. However, standard entanglement measurements can lead to incomplete state reconstruction and characterization. Here, we implement a resonator-based detection system that reveals entanglement between sideband modes of twin beams, achieving full tomography and retrieving often ignored quantum correlations. Unlike standard spectral measurements such as homodyne detection, resonator detection can independently address the sidebands of each beam, thereby accessing these hidden correlations. Additionally, we show how phase shifts between the carrier and the sideband modes of the involved fields redistribute information and modify the observation of entanglement for different witnesses. The ability of the resonant detection to independently address sideband modes of entangled states can contribute to enhancing the capacity for secure communication and quantum networking protocols.

Rincon Celis, Raul [University of Sao Paulo, Brazi

A Tutorial on Bayesian analysis of linear shock compression data

Gas gun and other shock compression experiments often produce shock wave velocity measurements that are linearly associated with particle velocity. Traditionally, this empirical relationship is quantified with a single Hugoniot curve that is estimated using least squares regression. However, for downstream modeling and simulation tasks, it is often more useful to have multiple Hugoniot curves in the pressure–volume plane that are consistent with the data. We employ Bayesian uncertainty quantification methods as a framework for propagating measurement uncertainty through to model parameters and predictions. Specifically, this Tutorial shows how to sample multiple Hugoniot curves in the pressure–volume plane that are consistent with the shock wave-particle velocity measurements in a two-step Bayesian approach. First, we obtain an analytical expression for the posterior distribution of the linear model parameters using Bayesian linear regression. Second, we propagate samples from the posterior distribution through the Rankine–Hugoniot equations to yield Hugoniot curves in the pressure–volume plane. The procedure is demonstrated with publicly available data on argon, copper, and nickel, and compared against bootstrapping and linear regression. The Bayesian procedure is shown to be interpretable, computationally inexpensive, and less sensitive than an alternative bootstrapping approach to the removal of the point in the copper dataset that has the largest particle velocity. As a Tutorial on Bayesian methodology for the shock compression community, we provide several derivations and explanations that make this paper self-contained, and make all code and data available at github.com/llnl/BALSCD.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC

First multi-institutional systematic comparison of the neutron ambient dose equivalent produced by proton therapy systems

Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.

LUPIN

Electron temperature relations and the direct N, O, Ne, S, and Ar abundances of 49 959 star-forming galaxies in DESI data release 2

We present the largest direct-method abundance catalogue of galaxies to date, containing measurements of 49 959 star-forming galaxies at z<0.96 from DESI (Dark Energy Spectroscopic Instrument) data release 2. By directly measuring electron temperatures across multiple ionization zones, we provide constraints on a number of electron temperature relations. Using the temperature measurements, we derive reliable abundances for N, O, Ne, S, and Ar, and measure the evolution of abundances and abundance ratios of as a function of metallicity and other galaxy properties. Our measurements include direct oxygen abundances for 49 507 galaxies, leading to the discovery of the two most metal-poor galaxies in the nearby Universe, with oxygen abundances of 12+log⁡(O/H)=6.77−0.03+0.03 dex (1.2 per cent Z⊙⁠) and 12+log⁡(O/H)=6.81−0.04+0.04 dex (1.3 per cent Z⊙⁠). We identify a rare outlier population of 24 galaxies with high-N/O ratios at low metallicity, reminiscent of galaxy abundances observed in the early Universe. We find the Ne/O ratio is constant at low metallicity but increases gradually at 12+log(O/H)>8.105±0.004 dex. We show that the S/O and Ar/O abundance ratios are strongly correlated, consistent with the expected additional Type Ia enrichment channel for S and Ar. In this work, we present an initial survey of the key properties of the sample, with this data set serving as a foundation for extensive future work on galaxy abundances at low redshift.

Scholte, D. [Edinburgh U., Inst. Astron.] (ORCID:0