Search NASA⌕ Search

SEARCH · Search NASA

Results for “System Operator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Broadband carbon monoxide laser system operating in the wavelength range of 2.5 - 8.3 {mu}m

A two-cascade frequency conversion of CO-laser radiation is demonstrated in a single sample of a nonlinear ZnGeP{sub 2} crystal. The crystal is pumped by a repetitively pulsed cryogenic lowpressure CO laser operating on {approx}150 vibration - rotational transitions in the wavelength range 5.0 - 7.5 {mu}m, which corresponds to the frequency range of a half octave. In the first conversion cascade, generation of second harmonic and sum frequencies of various pairs of CO-laser radiation give {approx}350 emission lines in the wavelength range 2.5 - 3.7 {mu}m. In the second cascade, by mixing the radiation converted in the first cascade with the residual radiation of the CO laser we have obtained {approx}90 lines in the range 4.3 - 5.0 {mu}m and more than 80 lines in the range 7.5 - 8.3 {mu}m. Thus, using a single sample of the nonlinear ZnGeP{sub 2} crystal pumped by the radiation of a single CO laser we have produced a source of broadband (more than one and a half octaves) laser radiation, simultaneously operating at {approx}670 lines in the wavelength range 2.5 - 8.3 {mu}m. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improving Distribution System Operations Using Fleet Control of Electrolyzers

The proliferation of electrolyzers presents an opportunity for grid operators. Fast response times and the use of hydrogen as storage can be leveraged in a symbiotic way to support increasing penetration levels of photovoltaics (PV) in the distribution grid. This work presents the grid integration of an electrolyzer fleet and its control applications to minimize the impact of increasing solar PV penetration in the distribution network. The study involves a feeder model of a real utility circuit from a utility partner with an operational model of a fleet of electrolyzers. The operational improvements are quantified with performance metrics. The metrics show that the fleet control application of the electrolyzers can aid in reducing overvoltages, voltage fluctuations, and control device operations induced by intermittent solar generation. The locational dependence of electrolyzers are also discussed in terms of performance metrics.

39 EE - Hydrogen and Fuel Cell Technologies (EE-3F↗

UNITY: Unified Memory and File Space. In: ROSS '17 Proceedings of the 7th International Workshop on Runtime and Operating Systems for Supercomputers ROSS 2017, Article No. 6

This paper describes the vision for UNITY, a new high-performance computing focused data storage abstraction that places the entire memory hierarchy, including both traditionally separated memory-and file-based data storage, into one storage continuum. Through the use of a novel API and a set of services centered around a smart runtime system, UNITY is able to provide a number of valuable and interesting benefits. The unified storage space provides a scalable and resilient data environment that dynamically manages the mapping of data onto available resources based on multiple factors, including desired persistence and energy budget considerations. By eliminating the need for high-performance computing domain scientists to develop architecture-dependent optimizations for rapidly evolving data storage technologies, UNITY addresses both ease-of-use and performance.

Jones, Terry↗

Extreme Performance Scalable Operating Systems Final Progress Report (July 1, 2008 - October 31, 2011)

This is the final progress report for the FastOS (Phase 2) (FastOS-2) project with Argonne National Laboratory and the University of Oregon (UO). The project started at UO on July 1, 2008 and ran until April 30, 2010, at which time a six-month no-cost extension began. The FastOS-2 work at UO delivered excellent results in all research work areas: * scalable parallel monitoring * kernel-level performance measurement * parallel I/0 system measurement * large-scale and hybrid application performance measurement * onlne scalable performance data reduction and analysis * binary instrumentation

97 MATHEMATICS AND COMPUTING↗

HPC Colony II: FAST_OS II: Operating Systems and Runtime Systems at Extreme Scale

HPC Colony II has been a 36-month project focused on providing portable performance for leadership class machines—a task made difficult by the emerging variety of more complex computer architectures. The project attempts to move the burden of portable performance to adaptive system software, thereby allowing domain scientists to concentrate on their field rather than the fine details of a new leadership class machine. To accomplish our goals, we focused on adding intelligence into the system software stack. Our revised components include: new techniques to address OS jitter; new techniques to dynamically address load imbalances; new techniques to map resources according to architectural subtleties and application dynamic behavior; new techniques to dramatically improve the performance of checkpoint-restart; and new techniques to address membership service issues at scale.

97 MATHEMATICS AND COMPUTING↗

Workshop on DR System Operator Breakout Session

Workshop breakout questions: Is it possible to use load response for ancillary services? Is it desirable? Is it worth the effort? What is required? What are the obstacles? How can DOE help?

ancilliary services↗

Renewable Electricity Futures Study - Volume 4: Bulk Electric Power Systems. Operations and Transmission Planning

The Renewable Electricity Futures (RE Futures) Study investigated the challenges and impacts of achieving very high renewable electricity generation levels in the contiguous United States by 2050. The analysis focused on the sufficiency of the geographically diverse U.S. renewable resources to meet electricity demand over future decades, the hourly operational characteristics of the U.S. grid with high levels of variable wind and solar generation, and the potential implications of deploying high levels of renewables in the future. RE Futures focused on technical aspects of high penetration of renewable electricity; it did not focus on how to achieve such a future through policy or other measures. Given the inherent uncertainties involved with analyzing alternative long-term energy futures as well as the multiple pathways that might be taken to achieve higher levels of renewable electricity supply, RE Futures explored a range of scenarios to investigate and compare the impacts of renewable electricity penetration levels (30%–90%), future technology performance improvements, potential constraints to renewable electricity development, and future electricity demand growth assumptions. RE Futures was led by the National Renewable Energy Laboratory (NREL) and the Massachusetts Institute of Technology (MIT). Learn more at the RE Futures website. http://www.nrel.gov/analysis/re_futures/

24 POWER TRANSMISSION AND DISTRIBUTION↗