Search NASA⌕ Search

SEARCH · Search NASA

Results for “TAPE RECORDER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Method for Visually Integrating Multiple Data Acquisition Technologies for Real Time and Retrospective Analysis

A system for display on a single video display terminal of multiple physiological measurements is provided. A subject is monitored by a plurality of instruments which feed data to a computer programmed to receive data, calculate data products such as index of engagement and heart rate, and display the data in a graphical format simultaneously on a single video display terminal. In addition live video representing the view of the subject and the experimental setup may also be integrated into the single data display. The display may be recorded on a standard video tape recorder for retrospective analysis.

Bogart, Edward H.↗

Solid-State Recorders Enhance Scientific Data Collection

Under Small Business Innovation Research (SBIR) contracts with Goddard Space Flight Center, SEAKR Engineering Inc., of Centennial, Colorado, crafted a solid-state recorder (SSR) to replace the tape recorder onboard a Spartan satellite carrying NASA's Inflatable Antenna Experiment. Work for that mission and others has helped SEAKR become the world leader in SSR technology for spacecraft. The company has delivered more than 100 systems, more than 85 of which have launched onboard NASA, military, and commercial spacecraft including imaging satellites that provide much of the high-resolution imagery for online mapping services like Google Earth.

Source record↗

Calibration tests on magnetic tape lightning current detectors

The low cost, passive, peak lightning current detector (LCD) invented at the NASA/Kennedy Space Center, uses magnetic audio recording tape to sense the magnitude of the peak magnetic field around a conductor carrying lightning currents. Test results show that the length of audio tape erased was linearly related to the peak simulated lightning currents in a round conductor. Accuracies of + or - 10% were shown for measurements made using a stopwatch readout technique to determine the amount of tape erased by the lightning current. The stopwatch technique is a simple, low cost means of obtaining LCD readouts and can be used in the field to obtain immediate results. Where more accurate data are desired, the tape is played and the output recorded on a strip chart, oscilloscope, or some other means so that measurements can be made on that recording. Conductor dimensions, tape holder dimensions, and tape formulation must also be considered to obtain a more accurate result. If the shape of the conductor is other than circular (i.e., angle, channel, H-beam), an analysis of the magnetic field is required to use an LCD, especially at low current levels.

Crouch, K. E.↗

Portable low-frequency vibration measuring and recording system

Information gathering system measures and records vibrations which affect personnel comfort in space, air, and surface vehicles. Three vibration transducers with mutually perpendicular axes control the frequency output of voltage controlled oscillators /VCO/. Outputs of VCO'S are multiplexed and then recorded on one track of stereo tape recorder.

Clevenson, S. A.↗

Surface-pressure fluctuations associated with aerodynamic noise on the space shuttle launch configuration at transonic and supersonic speeds

A 0.035-scale space shuttle model was recently tested at Ames Research Center to define the fluctuating surface pressures during the launch phase of the full-scale vehicle. A 120-channel data acquisition and reduction system was employed to obtain fluctuating pressure measurements from 240 pressure transducers in two separate data passes. Time histories from all transducers were recorded on four 32-track FM tape recorders. A minicomputer was used to compute and record on-line rms values, the fluctuating pressure coefficient, and full-scale dB levels. The minicomputer also partially controlled the test conditions and fully controlled all data acquisition sequences, thus greatly improving the efficiency of test operations. This paper presents details of the tests and illustrates the fluctuating pressures that will occur on the space shuttle and launch vehicle.

Hanly, R. D.↗

Application of laser velocimetry to an unsteady transonic flow

Measurements of mean velocity, turbulent kinetic energy, and turbulent shear stress have been obtained in an unsteady but periodic flow. Polystyrene spheres, 0.35-0.55 microns in diameter, were injected into the tunnel settling chamber to seed the flow for a laser velocimeter. Synchronized counters together with an encoding interface and digital-to-analog converters were used to record the data on an analog tape recorder. Profiles of velocity and turbulence quantities are presented for several times during the periodic flow.

Seegmiller, H. L.↗

Spartan - Space at low-cost

Mission profiles and objectives of the Spartan Shuttle payload are described. Spartan was designed to provide extended observations normally carried out for only a few minutes using sounding rockets. The payload will be placed in co-orbit with the Orbiter by the RMS arm and controlled by a ground-based researcher or by an on-board program. Spartan features minimal battery power, batteries, and control systems and no redundancy. Thermal control is added because the flights last 100-1000 times as long as those on sounding rockets. Data are recorded by an on-board tape recorder and operations are controlled by an on-board microprocessor. Spartan 1 will carry a star-pointer and X-ray detectors for high energy astrophysics experiments. Spartan 2 will gather solar physics data in the form of temperatures of hydrogen gas and ions and electrons. Particle densities will also be monitored and a 43 cm solar telescope will produce UV and white light solar coronagraphs. UV spectroscopy of stars, clouds and galaxies will be performed by the Spartan 3 payload.

Source record↗

Development of the VOLT-A shuttle experiment

The NASA Lewis Research Center (LeRC) is investigating potential problems associated with the operation of high voltage solar cell arrays in the space plasma environment. At high voltages, interactions between the solar array and the space plasma could result in unacceptable levels of electrical discharge (arcing) and/or parasitic losses (current drains from the array to the plasma). The objective of the Voltage Operating Limit Tests (VOLT-A) Shuttle bay experiment is to characterize space plasma/solar cell panel interactions in low earth orbit. VOLT-A consists of an experiment plate subassembly which contains four solar panels, an electronics subassembly and a Langmuir probe subassembly mounted on an MPESS carrier. During a given 8.25 hour data taking period (5-1/2 continuous orbits), the solar panels, which represent state-of-the-art solar cell technologies, will be sequentially subjected to bias voltages in steps ranging from minus 626 V to plus 313 V. Appropriate measurements will be made at each voltage to characterize arcing and parasitic losses. Corresponding measurements of the plasma environment (plasma density, electron temperature and neutral density) will also be made. Data will be recorded on an on-board tape recorder for subsequent data reduction and analysis.

Bifano, W. J.↗

Development of the VOLT-A Shuttle experiment

The NASA Lewis Research Center (LeRC) is investigating potential problems associated with the operation of high voltage solar cell arrays in the space plasma environment. At high voltages, interactions between the solar array and the space plasma could result in unacceptable levels of electrical discharge (arcing) and/or parasitic losses (current drains from the array to the plasma). The objective of the Voltage Operating Limit Tests (VOLT-A) Shuttle bay experiment is to characterize space plasma/solar cell panel interactions in low earth orbit. VOLT-A consists of an experiment plate subassembly which contains four solar panels, an electronics subassembly and a Langmuir probe subassembly mounted on an MPESS carrier. During a given 8.25 hour data taking period (5-1/2 continuous orbits), the solar panels, which represent state-of-the-art solar cell technologies, will be sequentially subjected to bias voltages in steps ranging from minus 626 V to plus 313 V. Appropriate measurements will be made at each voltage to characterize arcing and parasitic losses. Corresponding measurements of the plasma environment (plasma density, electron temperature and neutral density) will also be made. Data will be recorded on an on-board tape recorder for subsequent data reduction and analysis.

Bifano, William J.↗

A photoelectric technique for measuring lightning-channel propagation velocities from a mobile laboratory

The present device for lightning channel propagation-velocity determination employs eight photodetectors mounted behind precision horizontal slits in the focal plane of a photographic camera lens. The eight photodetector pulses, IRIG-B time, and slow and fast electric field-change waveforms are recorded on a 14-track analog tape recorder. A comparison of the present results with those obtained by a streaking camera shows no significant differences between the velocities obtained from the same strokes with the two systems; neither is there any difference in pulse characteristics or in the velocities calculated from them.

Mach, Douglas M.↗

Ultra-high density recording technologies

The Engineering Research Center in Data Storage Systems at Carnegie Mellon University in cooperation with the National Storage Industry Consortium has selected goals of achieving 10 Gbit/sq in. recording density in magnetic and magneto-optic disk recording and 1 terabyte/cubic in. magnetic tape recording technologies. This talk describes the approaches being taken and the status of research leading to these goals.

Kryder, Mark H.↗