Ultra-low liquid helium temperature in-situ TEM sample holder
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Abstract not provided.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.
Slides containing updated PIE results for AFC-4C-R5 (MNT20E)
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The desire to image specimens in liquids has led to the development of open-cell and closed-cell techniques in transmission electron microscopy (TEM). The closed-cell approach is currently more common in TEM and has yielded new insights into a number of biological and materials processes in liquid environments. The open-cell approach, which requires an environmental TEM (ETEM), is technically challenging but may be advantageous in certain circumstances due to fewer restrictions on specimen and detector geometry. Here, we demonstrate a novel approach to open-cell liquid TEM, in which we use salt particles to facilitate the in situ formation of droplets of aqueous solution that envelope specimen particles coloaded with the salt. This is achieved by controlling sample temperature between 1 and 10°C and introducing water vapor to the ETEM chamber above the critical pressure for the formation of liquid water on the salt particles. Our use of in situ hydration enables specimens to be loaded into a microscope in a dry state using standard 3 mm TEM grids, allowing specimens to be prepared using trivial sample preparation techniques. Furthermore, our future aim will be to combine this technique with an in situ light source to study photocorrosion in aqueous environments.
For over 25 years, transmission electron microscopy (TEM) has provided a method for the study of aerosol particles with sizes from below the optical diffraction limit to several microns, resolving the particles as well as smaller features. The wide use of this technique to study aerosol particles has contributed important insights about environmental aerosol particle samples and model atmospheric systems. TEM produces an image that is a 2D projection of aerosol particles that have been impacted onto grids and, through associated techniques and spectroscopies, can contribute additional information such as the determination of elemental composition, crystal structure, and 3D particle structures. Soot, mineral dust, and organic/inorganic particles have all been analyzed using TEM and spectroscopic techniques. TEM, however, has limitations that are important to understand when interpreting data including the ability of the electron beam to damage and thereby change the structure and shape of particles, especially in the case of particles composed of organic compounds and salts. In this paper, we concentrate on the breadth of studies that have used TEM as the primary analysis technique. Another focus is on common issues with TEM and cryogenic-TEM. Insights for new users on best practices for fragile particles, that is, particles that are easily susceptible to damage from the electron beam, with this technique are discussed. Tips for readers on interpreting and evaluating the quality and accuracy of TEM data in the literature are also provided and explained.
In this work, we present the formulation and analysis of inert Plastic-Bonded eXplosive (PBX)-surrogates loaded with thermally expandable microspheres (TEMs). TEMs consist of a thermoplastic acrylonitrile shell (10-50 µm diameter) encapsulating an inert low boiling hydrocarbon. Upon heating, the TEMs expand as the shell softens while the hydrocarbon gasifies, increasing the internal pressure and expanding the particle by as much as 120 vol%. We hypothesize that TEM expansion within a PBX will introduce tunable changes in local density and porosity, and ultimately the shock sensitivity. This paper focuses on microstructural analysis of surrogate PBX-TEM formulations, both before and after thermally- induced TEM expansion. The formulations were analyzed by scanning electron microscopy (SEM), ultra-small angle neutron scattering (USANS), and X-ray Computed Tomography (x-ray CT) under various thermal conditions. Evidence suggests that TEM expansion within a PBX is a viable method to impart microstructural changes that are predicted to have a measurable, on-demand effect on the initiation sensitivity. Future work includes development of PBX-TEM formulations with HMX and shock initiation experiments.
The crystallization of an amorphous Ag–In–Sb–Te (AIST) phase change material (PCM) is studied using multiple in situ imaging techniques to directly quantify crystal growth rates over a broad range of temperatures. The measurable growth rates span from ≈ 10 –9 to ≈ 20 m/s. Recent results using dynamic transmission electron microscopy (TEM), a photoemission TEM technique, and TEM with sub-framed imaging are reported here and placed into the context of previous growth rate measurements on AIST. Dynamic TEM experiments show a maximum observed crystal growth rate for as-deposited films to be > 20 m/s. It is shown that crystal growth above the glass transition can be imaged in a TEM through use of subframing and a high-frame-rate direct electron detection camera. Challenges associated with the determination of temperature during in situ TEM experiments are described. Finally, preliminary nanocalorimetry results demonstrate the feasibility of collecting thermodynamic data for crystallization of PCMs with simultaneous TEM imaging.