Search NASA⌕ Search

SEARCH · Search NASA

Results for “TES, detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Transition-Edge Sensor Pixel Parameter Design of the Microcalorimeter Array for the X-Ray Integral Field Unit on Athena

The focal plane of the X-ray integral field unit (X-IFU) for ESA's Athena X-ray observatory will consist of approximately 4000 transition edge sensor (TES) x-ray microcalorimeters optimized for the energy range of 0.2 to 12 kiloelectronvolts. The instrument will provide unprecedented spectral resolution of approximately 2.5 electronvolts at energies of up to 7 kiloelectronvolts and will accommodate photon fluxes of 1 milliCrab (90 counts per second) for point source observations. The baseline configuration is a uniform large pixel array (LPA) of 4.28 arcseconds pixels that is read out using frequency domain multiplexing (FDM). However, an alternative configuration under study incorporates an 18 by × 18 small pixel array (SPA) of 2 arcseconds pixels in the central approximately 36 arcseconds region. This hybrid array configuration could be designed to accommodate higher fluxes of up to 10 milliCrabs (900 counts per second) or alternately for improved spectral performance (less than 1.5 electronvolts) at low count-rates. In this paper we report on the TES pixel designs that are being optimized to meet these proposed LPA and SPA configurations. In particular we describe details of how important TES parameters are chosen to meet the specific mission criteria such as energy resolution, count-rate and quantum efficiency, and highlight performance trade-offs between designs. The basis of the pixel parameter selection is discussed in the context of existing TES arrays that are being developed for solar and x-ray astronomy applications. We describe the latest results on DC biased diagnostic arrays as well as large format kilo-pixel arrays and discuss the technical challenges associated with integrating different array types on to a single detector die.

Smith, S. J.↗

Development of a Test-Bed for Testing and Refining EarthEn’s Supercritical CO 2 Based Energy Storage System

EarthEn’s energy storage concept leverages supercritical carbon dioxide (sCO 2 ) as a working fluid and relies on compact, high-performance components operating at elevated pressures and temperatures. To accelerate component development and reduce technical risk prior to larger-scale demonstrations, Oak Ridge National Laboratory (ORNL) developed a 100 kW-scale sCO 2 test-bed under a Cooperative Research and Development Agreement with EarthEn (CRADA NO. NFE-24-10050). The objective of the work was to design and construct a flexible experimental facility capable of reproducing key thermodynamic state points and heat-transfer conditions relevant to EarthEn’s thermal energy storage (TES) cycle, with particular emphasis on enabling development and evaluation of next-generation heat exchangers and TES concepts. The test-bed consists of a closed-loop sCO 2 circulation system housed within an open-topped enclosure. In its as-installed configuration, dense-phase sCO 2 is recirculated through a printed circuit recuperator, an electrically heated section, a throttling device used to simulate turbine expansion, and a water-cooled printed circuit heat exchanger that rejects heat to the building chilled-water system before returning to the pump. The pump is driven by a variable frequency drive, enabling controlled adjustment of flow and operating point. A comprehensive instrumentation suite was integrated to support both safe operation and high-quality data collection. Installed sensors include Coriolis flow meters for sCO 2 flow rate and density, resistance temperature detectors and thermocouples distributed throughout the loop (including the heated section and key heat exchanger ports), and pressure transducers for absolute and differential pressure measurements. The facility was designed to support high-pressure (19 MPa nominal) and high-temperature (575°C nominal) operation with credited overpressure protection provided by a rupture disk. Nominal operating conditions were selected to support 100 kW-class testing while maintaining flexibility for non-heated and heated shakedown, control development, and future integration of advanced TES test sections. In parallel with facility development, a system-level thermal-hydraulic model was created using Modelica-based tools to support component sizing, anticipate performance over targeted test conditions, and establish a framework for future model calibration against experimental data. At the conclusion of the project performance period, the facility was in final assembly, and the pressure boundary was nearly completed. However, several practical challenges associated with high-pressure/high-temperature systems and specialized component procurement impacted schedule and prevented initial pump-driven operation and full commissioning within the available resources. This report documents the as-built design, operating capabilities, and instrumentation, and it summarizes key lessons learned related to heater fabrication and testing, first-of-a-kind assembly factors, specialty flange supply constraints, and fill pump corrective actions. Finally, it outlines a phased plan for future commissioning and experimental campaigns, including control and instrumentation shakedown, heater characterization, model calibration, and testing at state points representative of EarthEn’s TES cycle.

25 ENERGY STORAGE↗

First Operation of TES Microcalorimeters in Space with the Micro-X Sounding Rocket

Micro-X is a sounding rocket-borne instrument that uses a microcalorimeter array to perform high-resolution X-ray spectroscopy. This instrument flew for the first time on July 22nd, 2018, from the White Sands Missile Range, USA. This flight marks the first successful operation of a transition-edge sensor array and its time-division multiplexing readout system in space. This launch was dedicated to the observation of the supernova remnant Cassiopeia A. A failure in the attitude control system prevented the rocket from pointing and led to no time on target. The onboard calibration source provided X-rays in flight, and it is used to compare detector performance during preflight integration, flight, and after the successful post-flight recovery. This calibration data demonstrate the capabilities of the detector in a space environment as well as its potential for future flight.

TES↗

Reduced-Scale Transition-Edge Sensor Detectors for Solar and X-Ray Astrophysics

We have developed large-format, close-packed X-ray microcalorimeter arrays fabricated on solid substrates, designed to achieve high energy resolution with count rates up to a few hundred counts per second per pixel for X-ray photon energies upto 8 keV. Our most recent arrays feature 31-micron absorbers on a 35-micron pitch, reducing the size of pixels by about a factor of two. This change will enable an instrument with significantly higher angular resolution. In order to wire out large format arrays with an increased density of smaller pixels, we have reduced the lateral size of both the microstrip wiring and the Mo/Au transition-edge sensors (TES). We report on the key physical properties of these small TESs and the fine Nb leads attached, including the critical currents and weak-link properties associated with the longitudinal proximity effect.

Arrays↗

Development of a Transition-Edge Sensor Anti-Coincidence Detector for a Probe Class Mission

The Light Element Mapper (LEM), a probe class mission proposal slated for submission in 2023, combines a large X-ray optic with an extremely large format microcalorimeter array to probe the physics of galaxy formation with a grasp 22x greater than ATHENA and 7x greater than Lynx. The focal plane for LEM requires a larger anti-coincidence detector than the other missions while maintaining or exceeding their high-speed response, presenting a challenge for claiming technical readiness at the time of the announcement of opportunity (AO). We will perform a rapid demonstration in the next year including design, fabrication and integration and test of a high-fidelity transition-edge sensor (TES) based device at a scale suitable for LEM.

James Chervenak↗

Superconducting Detector Arrays for Astrophysics

The next generation of astrophysics instruments will feature an order of magnitude more photon sensors or sensors that have an order of magnitude greater sensitivity. Since detector noise scales with temperature, a number of candidate technologies have been developed that use the intrinsic advantages of detector systems that operate below 1 Kelvin. Many of these systems employ of the superconducting phenomena that occur in metals at these temperatures to build ultrasensitive detectors and low-noise, low-power readout architectures. I will present one such system in use today to meet the needs of the astrophysics community at millimeter and x-ray wavelengths. Our group at NASA in collaboration with Princeton, NIST, Boulder and a number of other groups is building large format arrays of superconducting transition edge sensors (TES) read out with multiplexed superconducting quantum interference devices (SQUID). I will present the high sensitivity we have achieved in multiplexed x-ray sensors with the TES technology and describe the construction of a 1000-sensor TES/SQUID array for microwave measurements. With our collaboration's deployment of a kilopixel TES array for 2 mm radiation at the Atacarna Cosmology Telescope in November 2007, we have first images of the lensed Cosmic Microwave Background at fine angular scales.

Chervenak, James↗

Radiometry Measurements of Mars at 1064 nm Using the Mars Orbiter Laser Altimeter

Measurements by the Mars Orbiter Laser Altimeter (MOLA) on board the Mars Global Surveyor (MGS) may be used to provides a radiometric measurement of Mars in addition to the topographic measurement. We will describe the principle of operation, a mathematical model, and the receiver calibration in this presentation. MOLA was designed primarily to measure Mars topography, surface roughness end the bidirectional reflectance to the laser beam. To achieve the highest sensitivity the receiver detection threshold is dynamically adjusted to be as low as possible while keeping a predetermined false alarm rate. The average false alarm rate 29 monitored in real time on board MOLA via a noise counter, whose output is fed to the threshold control loop. The false alarm rate at a given threshold is a function of the detector output noise which is the sum of the photo detector, shot noise due to the background light seen by the detector and the dark noise. A mathematical model has been developed that can be used to numerically solve for the optical background power given the MOLA threshold setting and the average noise count. The radiance of Mars can then be determined by dividing the optical power by the solid angle subtended by the MOLA receiver, the receiver optical band-width, end the Mars surface area within the receiver field of view. The phase angle which is the sun-Mars-MOLA angle is available from the MGS database. MOLA also measures simultaneously the bidirectional reflectance of Mars vie its 106-lum loser beam at nadir with nearly zero phase angle. The optical bandwidth of the MOLA receiver is 2um full width at half maximum (FWHM) and centered at 106-lum. The receiver field of view is 0.95mrad FWHM. The nominated spacecraft altitude is 100km and the ground track speed is about 3km/s. Under normal operation, the noise counter are read and the threshold levels are updated at 1Hz. The receiver sensitivity is limited by the detector dark noise to about 0.1nW, which corresponds to less than 2% the maximum radiance during daytime from the brightest area on Mars. The results from the mathematical model agree well with the prelaunch measurements at several calibrated optical power levels. The radiance of sunlit Mars estimated with this technique correlates well with the measurement from the MGS. Thermal Emission Spectrometer (TES) and the Hubble Space Telescope at similar wavelength.

Sun, Xiao-Li↗

Particle Response of Antenna-Coupled TES Arrays: Results from SPIDER and the Laboratory

Future mm-wave and sub-mm space missions will employ large arrays of multiplexed transition-edge-sensor (TES) bolometers. Such instruments must contend with the high flux of cosmic rays beyond our atmosphere that induce ‘glitches’ in bolometer data, which posed a challenge to data analysis from the Planck bolometers. Future instruments will face the additional challenges of shared substrate wafers and multiplexed readout wiring. Here, we explore the susceptibility of modern TES arrays to the cosmic ray environment of space using two data sets: the 2015 long-duration balloon flight of the SPIDER cosmic microwave background polarimeter, and a laboratory exposure of SPIDER flight hardware to radioactive sources. We find manageable glitch rates and short glitch durations, leading to minimal effect on SPIDER analysis. We constrain energy propagation within the substrate through a study of multi-detector coincidences and give a preliminary look at pulse shapes in laboratory data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bolometeric detector arrays for CMB polarimetry

We describe the development of antenna coupled bolometers for CMB polarization experiments. The necessary components of a bolometric CMB polarimeter - a beam forming element, a band defining filter, and detectors - are all fabricated on a silicon chip with photolithography.

TES bolometers↗

Instrument Performance of GISMO, a 2 Millimeter TES Bolometer Camera used at the IRAM 30 m Telescope

In November of 2007 we demonstrated a monolithic Backshort-Under-Grid (BUG) 8x16 array in the field using our 2 mm wavelength imager GISMO (Goddard IRAM Superconducting 2 Millimeter Observer) at the IRAM 30 m telescope in Spain for astronomical observations. The 2 mm spectral range provides a unique terrestrial window enabling ground-based observations of the earliest active dusty galaxies in the universe and thereby allowing a better constraint on the star formation rate in these objects. The optical design incorporates a 100 mm diameter silicon lens cooled to 4 K, which provides the required fast beam yielding 0.9 lambda/D pixels. With this spatial sampling, GISMO will be very efficient at detecting sources serendipitously in large sky surveys, while the capability for diffraction limited imaging is preserved. The camera provides significantly greater detection sensitivity and mapping speed at this wavelength than has previously been possible. The instrument will fill in the spectral energy distribution of high redshift galaxies at the Rayleigh-Jeans part of the dust emission spectrum, even at the highest redshifts. Here1 will we present early results from our observing run with the first fielded BUG bolometer array. We have developed key technologies to enable highly versatile, kilopixel, infrared through millimeter wavelength bolometer arrays. The Backshort-Under-Grid (BUG) array consists of three components: 1) a transition-edge-sensor (TES) based bolometer array with background-limited sensitivity and high filling factor, 2) a quarter-wave reflective backshort grid providing high optical efficiency, and 3) a superconducting bump-bonded large format Superconducting Quantum Interference Device (SQUID) multiplexer readout. The array is described in more detail elsewhere (Allen et al., this conference). In November of 2007 we demonstrated a monolithic 8x 16 array with 2 mm-pitch detectors in the field using our 2 mm wavelength imager GISMO (Goddard IRAM Superconducting 2 Millimeter Observer) at the IRAM 30 m telescope in Spain for astronomical observations. The 2 mm spectral range provides a unique terrestrial window enabling ground-based observations of the earliest active dusty galaxies in the universe and thereby allowing a better constraint on the star formation rate in these objects. The optical design incorporates a 100 mm diameter silicon lens cooled to 4 K, which provides the required fast beam yielding 0.9 lambda1D pixels. With this spatial sampling, GISMO will be very efficient at detecting sources serendipitously in large sky surveys, while the capability for diffraction limited imaging is preserved. The camera provides significantly greater detection sensitivity and mapping speed at this wavelength than has previously been possible. The instrument will fill in the spectral energy distribution of high redshift galaxies at the Rayleigh-Jeans part of the dust emission spectrum, even at the highest redshifts. Here I will we present early results from our observing run with the first fielded BUG bolometer array.

Staguhn, Johannes↗

Multicolor Detectors for Ultrasensitive Long-Wave Imaging Cameras

A document describes a zeptobolometer for ultrasensitive, long-wavelength sensors. GSFC is developing pixels based on the zeptobolometer design that sense three THz wavelengths simultaneously. Two innovations are described in the document: (1) a quasiparticle (QO) filter arrangement that enables a compact multicolor spectrum at the focal plane, and (2) a THz antenna readout by up to three bolometers. The innovations enable high efficiency by greatly reducing high, frequency-dependent microstrip losses, and pixel compactness by eliminating the need for bulky filters in the focal plane. The zeptobolometer is a small TES bolometer, on the scale of a few microns, which can be readily coupled through an impedance-matching resistor to a metal or dielectric antenna. The bolometer is voltage-biased in its superconducting transition, allowing the use of superconducting RF multiplexers to read out large arrays. The antenna is geometrically tapped at three locations so as to efficiently couple radiation of three distinct wavelengths to the individual TESs. The transition edge hot electrons in metals offer a simple, compact arrangement for antenna readout, which can be crucial in the THz where line losses at high frequencies can be substantial. A metallic grill filter acts as a high-pass filter and directs the low-frequency components to a location where they will be absorbed. The absorption spectrum shows that three well-separated THz bands are feasible. The filters can be made from high-purity dielectrics such as float zone silicon or sapphire.

Brown, Ari↗

Development of Kilo-Pixel Arrays of Transition-Edge Sensors for X-Ray Spectroscopy

We are developing kilo-pixel arrays of transition-edge sensor (TES) microcalorimeters for future X-ray astronomy observatories or for use in laboratory astrophysics applications. For example, Athena/XMS (currently under study by the european space agency) would require a close-packed 32x32 pixel array on a 250-micron pitch with < 3.0 eV full-width-half-maximum energy resolution at 6 keV and at count-rates of up to 50 counts/pixel/second. We present characterization of 32x32 arrays. These detectors will be readout using state of the art SQUID based time-domain multiplexing (TDM). We will also present the latest results in integrating these detectors and the TDM readout technology into a 16 row x N column field-able instrument.

Adams, J. S.↗

Quantifying the Effect of Cosmic Ray Showers on the X-IFU Energy Resolution

The X-ray Integral Field Unit (X-IFU) will operate an array of more than 3000 Transition Edge Sensor pixels at 90 mK with an unprecedented energy resolution of 2.5 eV at 7 keV. In space, primary cosmic rays and secondary particles produced in the instrument structure will continuously deposit energy on the detector wafer and induce fluctuations on the pixels’ thermal bath. We have investigated through simulations of the X-IFU readout chain how these fluctuations eventually influence the energy measurement of X-ray photons. Realistic timelines of thermal bath fluctuations at different positions in the array are generated as a function of a thermal model and the expected distribution of the deposited energy of the charged particles. These are then used to model the TES response to these thermal perturbations and their influence on the onboard energy reconstruction process. Overall, we show that with adequate heatsinking, the main energy resolution degradation effect remains minimal and within the associated resolution allocation of 0.2 eV. We further study how a dedicated triggering algorithm could be put in place to flag the rarer large thermal events.

P. Peille↗

Thermal Impact of Cosmic Ray Interaction with an XRay Microcalorimeter Array

The X-ray Integral Field Unit (X-IFU) instrument on the Athena mission will be positioned at the Lagrangian point L2 and be subject to cosmic rays generated by astrophysics sources, primarily relativistic protons. Previous simulations have shown that particles of energy higher than 150 MeV will make it through the outer layers of the satellite. They will reach the detector wafer with a rate of 3 cts/sq. cm/s and a most probable energy deposited in the Si frame supporting the array at 150 keV. These events can affect the energy resolution of the detectors through the thermal fluctuations that they produce. This study assesses this potential problem and discusses two suggested design approaches to decrease the impact of cosmic ray in order to limit their effect to their allocation of 0.2 eV within the Athena/X-IFU energy-resolution budget. The first is the addition of a coating layer of high heat capacity material (e.g., Pd) and the second is the splitting of this coating into two thermal regions near the TES array to keep the heat away from the array. Implementing these two features is predicted to cause a decrease in the number of events above 1 μK by more than a factor 10 to ~ 1.5 cps when compared to an equivalent design without these features.

Antoine R. Miniussi↗

Development of the Microcalorimeter Array for the Line Emission Mapper (LEM) X-Ray Probe

The Line Emission Mapper (LEM) is a proposed NASA probe-class mission designed to study the formation of structure in the Universe. LEM will have a 14k pixel array of transition-edge sensor (TES) microcalorimeters that provide a spectral resolution of < 2.5 eV and a bandpass of 0.2-2 keV. In this paper, we report on the status and plan for continued development of the LMS microcalorimeter. This includes details of the TES and x-ray absorber design, and the measured performance in prototype arrays. We present a detailed budget for the energy resolution and show how the properties of the LEM pixels are well optimized for the baseline time-division-multiplexing (TDM) that will be used read out the array. Finally, we describe the design and performance of the first full scale LMS arrays which include the necessary mechanical and electrical interfaces needed for LEM and are a precursor to an engineering model detector.

Stephen J Smith↗

Array-scale performance of TES X-ray Calorimeters Suitable for Constellation-X

Having developed a transition-edge-sensor (TES) calorimeter design that enables high spectral resolution in high fill-factor arrays, we now present array-scale results from 32-pixel arrays of identical closely packed TES pixels. Each pixel in such an array contains a Mo/Au bilayer with a transition temperature of 0.1 K and an electroplated Au or Au/Bi xray absorber. The pixels in an array have highly uniform physical characteristics and performance. The arrays are easy to operate due to the range of bias voltages and heatsink temperatures over which solution better than 3 eV at 6 keV can be obtained. Resolution better than 3 eV has also been obtained with 2x8 time-division SQUID multiplexing. We will present the detector characteristics and show spectra acquired through the read-out chain from the multiplexer electronics through the demultiplexer software to real-time signal processing. We are working towards demonstrating this performance over the range of count rates expected in the observing program of the Constellation-X observatory. We mill discuss the impact of increased counting rate on spectral resolution, including the effects of crosstalk and optimal-filtering dead time.

Kilbourne, C. A.↗

Observation of Long-Lived UV-Induced Fluorescence from Environmental Materials Using the HVeV Detector as Developed for SuperCDMS

Here, we describe recent experiments using a SuperCDMS HVeV single-charge sensitive detector illuminated with an ultraviolet LED (275 nm) and a monochromatic laser(650 nm) using a dual fiber optic system installed in a small dilution refrigerator at Stanford University. We observed a population of fluorescence background events after UV exposure but not after exposure to the laser source. The fluorescence was likely due to scattered UV photons absorbed outside the detector. We discuss the possibility of fluorescence being a contributor to the low energy excess background observed in above-ground Dark Matter experiments.

36 MATERIALS SCIENCE↗

Demonstration of Time Domain Multiplexed Readout for Magnetically Coupled Calorimeters

Magnetically coupled calorimeters (MCC) have extremely high potential for x-ray applications due to the inherent high energy resolution capability and being non-dissipative. Although very high energy-resolution has been demonstrated, until now there has been no demonstration of multiplexed read-out. We report on the first realization of a time domain multiplexed (TDM) read-out. While this has many similarities with TDM of transition-edge-sensors (TES), for MGGs the energy resolution is limited by the SQUID read-out noise and requires the well established scheme to be altered in order to minimize degradation due to noise aliasing effects. In cur approach, each pixel is read out by a single first stage SQUID (SQ1) that is operated in open loop. The outputs of the SQ1 s are low-pass filtered with an array of low cross-talk inductors, then fed into a single-stage SQUID TD multiplexer. The multiplexer is addressed from room temperature and read out through a single amplifier channel. We present results achieved with a new detector platform. Noise performance is presented and compared to expectations. We have demonstrated multiplexed X-ray spectroscopy at 5.9keV with delta_FWHM=10eV. In an optimized setup, we show it is possible to multiplex 32 detectors without significantly degrading the Intrinsic detector resolution.

Porst, J.-P.↗