Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMOCOUPLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Scanning thermal microscopy based on a quartz tuning fork and a micro-thermocouple in active mode (2ω method)

A novel probe for scanning thermal microscope using a micro-thermocouple probe placed on a Quartz Tuning Fork (QTF) is presented. Instead of using an external deflection with a cantilever beam for contact detection, an original combination of piezoelectric resonator and thermal probe is employed. Due to a non-contact photothermal excitation principle, the high quality factor of the QTF allows the probe-to-surface contact detection. Topographic and thermal scanning images obtained on a specific sample points out the interest of our system as an alternative to cantilevered resistive probe systems which are the most spread.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of multiple heat flux components at the divertor target by using surface eroding thermocouples (invited)

The Surface Eroding Thermocouple (SETC) is a robust diagnostic utilized in DIII-D to provide fast, edge-localized modes (ELMs) resolved heat flux measurements, in particular in geometric regions that are too shadowed for traditional infrared thermography. In order to further investigate the power dissipation in the divertor region, a combination of flush-mounted and recessed SETCs was developed to assess the effect on surface heating from non-charged particles at the divertor target. Utilizing the Divertor Materials Evaluation System sample exposure platform, the first demonstration of the feasibility of using this new method to distinguish between the heat flux from charged particles and that from neutrals and radiative heating was achieved. This paper details the process of using the combination of flush SETCs and recessed SETCs to measure the multiple heat flux components at the divertor target and further discusses how to determine two important ratios, α (ratio of heat flux from charged particles deposit on recessed SETC to that deposit on flush SETC) and β (ratio of heat flux from non-charged particles deposit on recessed SETC to that deposit on flush SETC), in the estimation of the heat flux from non-charged particle sources. Using a time dependent ratio α, it was found that ~50% of the total incident heat flux is attributable to the non-charged particles in the fully detached open divertor in DIII-D. Finally, the new application of similar SETC diagnostics in the Small Angle Slot divertor with a V-like configuration and partial tungsten coated surface (SAS-VW) is also introduced.

47 OTHER INSTRUMENTATION↗

Anomaly Detection for Online Monitoring of Thermocouple Sensors in the Advanced Test Reactor

This study explores data-driven anomaly detection methods to analyze sensor fail- ures in the Advanced Gas Reactor (AGR) nuclear fuel irradiation experiments. Specifically, we examine failures of thermocouples (TCs), which are critical for mon- itoring and controlling in-reactor temperatures during operation. Failures were pri- marily observed during abrupt power transitions and manifested as sensor drop-outs, drifts, or unexplained behavior. We applied three time-series analysis techniques— rolling mean smoothing, matrix profile, and vector auto-regression (VAR)—to de- tect anomalies in TC data prior to failure events. The rolling mean method effec- tively highlighted deviations aligned with reported failures, while the matrix profile provided partial early warning but sometimes flagged normal fluctuations during power-down periods. VAR shows potential in capturing multivariate dependencies but requires further calibration. A rare case of TC drift was also documented, which did not result in failure, underscoring the challenge of building predictive models with sparse positive examples. Our findings demonstrate that traditional statistical tools can aid anomaly detection but have limited predictive power without richer training data. We propose future directions including synthetic data generation, real- time surrogate modeling, and multi-modal feature integration. This work provides a foundation for applying robust anomaly detection frameworks to mission-critical sensor systems in experimental settings.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Specific features of thermocouple calorimeter application for measurements of pulsed X-ray emission from plasma

It is shown that the accuracy of time-integrated measurements of pulsed X-ray emission from hot plasma with calibrated thermocouple calorimeters is mainly determined by two factors. The first and the most important factor is heating of the filter by the absorbed X-rays; as a result, the calorimeter measures the thermal radiation of the filter, which causes appreciable distortion of the temporal profile and amplitude of the recorded signal. The second factor is the dependence of the effective depth of X-ray absorption in the dielectric that covers the entrance window of the calorimeter on the energy of X-ray photons, i.e., on the recorded radiation spectrum. The results of model calculations of the calorimeter signal are compared with the experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of Thermocurrents in ILC cavities via measurements of the Seebeck Effect in niobium, titanium, and stainless steel thermocouples

The goals of Fermilab’s Superconductivity and Radio Frequency Development Department are to engineer, fabricate, and improve superconducting radio frequency (SCRF) cavities in the interest of advancing accelerator technology. Improvement includes exploring possible limitations on cavity performance and mitigating such impediments. This report focuses on investigating and measuring the Seebeck Effect observed in cavity constituents titanium, niobium, and stainless steel arranged in thermocouples. These junctions exist between cavities, helium jackets, and bellows, and their connection can produce a loop of electrical current and magnetic flux spontaneously during cooling. The experimental procedure and results are described and analyzed. Implications relating the results to cavity performance are discussed.

43 PARTICLE ACCELERATORS↗

Qualification Test Requirements Report for High-Temperature Irradiation-Resistant Thermocouples

The qualification of f high-temperature irradiation-resistant thermocouples (HTIR-TCs) is set forth utilizing the Advanced Gas Reactor (AGR) 5/6/7 test in the Advanced Test Reactor located at the Idaho National Laboratory (INL). The requirements to achieve the qualification are appropriate design, construction, and calibration followed by proper installation and performance parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary Calibration System Report for High-Temperature Irradiation-Resistant Thermocouples

An established calibration procedure is presented for the high-temperature irradiation-resistant thermocouple (HTIR-TC). Standard calibration curves for both an individual (i.e. case by case basis) and common calibrations is shown. The error limits within ±3 σ are ±1% for the individual calibrations and ±2% for the common calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Temperature Irradiation-Resistant Thermocouple Qualification (Test Results Report)

This is a qualification report for the high-temperature irradiation-resistant thermocouple (HTIR-TC) developed by Nuclear Energy Enabling Technologies Advanced Sensors and Instrumentation program. Utilizing the Advanced Gas Reactor (AGR) 5/6/7 test conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory, the HTIR-TCs measured temperatures upwards of 1500°C during accident conditions. The HTIR TCs are thus qualified to perform and withstand an 18-month refueling cycle typical of nuclear power plants at the normal operating temperature, with a drift of less than ±1%. The HTIR-TC is also qualified for incorporating into a test fixture during new fuels tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗