Search NASA⌕ Search

SEARCH · Search NASA

Results for “THRESHOLD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Threshold for permanent refractive index change in crystalline silicon by femtosecond laser irradiation

An optical damage threshold for crystalline silicon from single femtosecond laser pulses was determined by detecting a permanent change in the refractive index of the material. This index change could be detected with unprecedented sensitivity by measuring the resonant wavelength shift of silicon integrated optics microring resonators irradiated with femtosecond laser pulses at 400 nm and 800 nm wavelengths. The threshold for permanent index change at 400 nm wavelength was determined to be 0.053 ± 0.007 J/cm{sup 2}, which agrees with previously reported threshold values for femtosecond laser modification of crystalline silicon. However, the threshold for index change at 800 nm wavelength was found to be 0.044 ± 0.005 J/cm{sup 2}, which is five times lower than the previously reported threshold values for visual change on the silicon surface. The discrepancy is attributed to possible modification of the crystallinity of silicon below the melting temperature that has not been detected before.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thresholds of absolute instabilities driven by a broadband laser

Absolute instability thresholds for stimulated Raman scattering and two-plasmon decay driven by a broadband laser pulse are evaluated numerically. The scalings of the calculated thresholds with density scale length, temperature, and central wavelength are qualitatively similar to existing analytic results. The threshold values, yet, reflect significant quantitative differences. Comparisons between thresholds calculated for various broadband power spectra suggest a universal scaling of the threshold intensity with laser coherence time ($\tau_{c}$). For SRS I thr ∝ $\tau_{c}^{-1/3}$, and for TPD I thr ∝ $\tau_{c}^{-1/2}$ .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Prediction of the energetic particle redistribution by an improved critical gradient model and analysis of the transport threshold

Based on the theory of critical gradient model (CGM) and following the simulation method proposed by Waltz et al., a combination of TGLFEP and EPtran code is employed to predict the energetic particle (EP) transport induced by Alfvén eigenmodes (AEs). To be consistent with the experiment, recent improvements to the simulation method include consideration of threshold evolution and orbit loss due to finite orbit width. The revised CGM is applied to simulate two DIII-D experimental discharges (#142111 and #153071). It well reproduces the experimental profiles with multiple unstable AEs and large-scale EP transport. Discharge #142111 had previously been simulated using a nonlinear MHD-kinetic code MEGA with a transport mechanism based on stochasticity induced by overlapping AE. By comparing the simulated EP profiles, we find that the AE transport threshold is approximated by both the MEGA nonlinear stability threshold and the proposed CGM threshold (error <5% for single n and <17% for multiple n simulation). Both of them are larger than the linear stability threshold of the most unstable AE mode by a quantity of the order of the flux needed to sustain EP transport by the background turbulence. Additionally, we have also applied the improved CGM to simulate the α particle redistribution for a China Fusion Engineering Test Reactor steady state scenario. Because of the clear separation between the AE unstable region and the loss cone, only a moderate α particle loss of ~9.6% is predicted.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of laser pulse repetition frequency on the optical breakdown threshold of quartz glass

The thresholds of optical breakdown in the volume of quartz glass were measured in relation to the number of pulses under irradiation by ultrashort laser pulses with different pulse repetition frequencies (1 – 400 kHz). Increasing this frequency from 10 to 400 kHz was found to substantially lower the breakdown threshold for 500-fs long pulses (at a wavelength of 1030 nm) and to lower to a smaller degree for 5-ps long pulses (515 nm). A strong frequency dependence of the breakdown threshold is observed under the same conditions as a manifold decrease of the breakdown threshold with increase in the number of pulses in a pulse train. The dependence of the optical breakdown on the number of pulses is attributable to the accumulation of point defects under multiple subthreshold irradiation, which affects the mechanism of collisional ionisation. In this case, the frequency dependence of the breakdown threshold of quartz glass is determined by the engagement of shortlived defects in the ionisation mechanism. (interaction of laser radiation with matter)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The H-mode power threshold in hydrogen plasmas in DIII-D

In DIII-D, experiments have been performed in hydrogen plasmas to determine the requirement for hydrogen operation in ITER. The H-mode threshold power has been determined to increase with input torque for both hydrogen and deuterium plasmas with the H-mode power threshold for hydrogen plasmas being greater by approximately a factor of 2 at zero torque than in comparable deuterium plasmas. The threshold power for hydrogen discharges with full counter-current beam injection is roughly the same as the threshold power for deuterium discharges with co-current beam injection. The plasma geometry also influences the power threshold through the vertical distance between the X-point and the divertor surface.

Gohil, P.↗

Parametric dependencies of locked mode thresholds in KSTAR L-mode plasmas

Resonant error fields with toroidal harmonics n = 1 and n = 2 in otherwise axisymmetric tokamak plasmas can drive disruptive locked modes when their strength exceeds a threshold value. This paper presents the sensitivity of error field threshold in global parameters such as line-averaged density and toroidal magnetic field as well as toroidal harmonics dependence in KSTAR L-mode plasmas. The error field threshold for mode-locking increases along with density up to a roll-over density, which coincides well with the linear ohmic confinement (LOC) to saturated ohmic confinement (SOC) density for the studied KSTAR plasmas. As a result, this non-monotonic density correlation of the error field threshold in LOC–SOC can be explained by a modification of existing theoretical scaling in SOC, while plasma rotation can also play an important role in setting the resonant error field threshold.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Damage thresholds for blaze diffraction gratings and grazing incidence optics at an X-ray free-electron laser

The Linac Coherent Light Source is upgrading its machine to high repetition rate and to extended ranges. Novel coatings, with limited surface oxidation, which are able to work at the carbon edge, are required. In addition, high-resolution soft X-ray monochromators become necessary. One of the big challenges is to design the mirror geometry and the grating profile to have high reflectivity (or efficiency) and at the same time survive the high peak energy of the free-electron laser pulses. For these reasons the experimental damage threshold, at 900 eV, of two platinum-coated gratings with different blazed angles has been investigated. The gratings were tested at 1° grazing incidence. To validate a model for which the damage threshold on the blaze grating can be estimated by calculating the damage threshold of a mirror with an angle of incidence identical to the angle of incidence on the grating plus the blaze angle, tests on Pt-coated substrates have also been performed. The results confirmed the prediction. Uncoated silicon, platinum and SiB 3 (both deposited on a silicon substrate) were also investigated. In general, the measured damage threshold at grazing incidence is higher than that calculated under the assumption that there is no energy transport from the volume where the photons are absorbed. However, it was found that, for the case of the SiB 3 coating, the grazing incidence condition did not increase the damage threshold, indicating that the energy transport away from the extinction volume is negligible.

43 PARTICLE ACCELERATORS↗

Trapping volumetric measurement by multidetector CT in chronic obstructive pulmonary disease: Effect of CT threshold

Purpose: The purpose of this study was to evaluate the effect of various computed tomography (CT) thresholds on trapping volumetric measurements by multidetector CT in chronic obstructive pulmonary disease (COPD).Methods: Twenty-three COPD patients were scanned with a 64-slice CT scanner in both the inspiratory and expiratory phase. CT thresholds of −950 Hu in inspiration and −950 to −890 Hu in expiration were used, after which trapping volumetric measurements were made using computer software. Trapping volume percentage (Vtrap%) under the different CT thresholds in the expiratory phase and below −950 Hu in the inspiratory phase was compared and correlated with lung function.Results: Mean Vtrap% was similar under −930 Hu in the expiratory phase and below −950 Hu in the inspiratory phase, being 13.18 ± 9.66 and 13.95 ± 6.72 (both lungs), respectively; this difference was not significant (P= 0.240). Vtrap% under −950 Hu in the inspiratory phase and below the −950 to −890 Hu threshold in the expiratory phase was moderately negatively correlated with the ratio of forced expiratory volume in one second to forced vital capacity and the measured value of forced expiratory volume in one second as a percentage of the predicted value.Conclusions: Trapping volumetric measurement with multidetector CT is a promising method for the quantification of COPD. It is important to know the effect of various CT thresholds on trapping volumetric measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Estimating Alarm Thresholds for Process Monitoring Data under Different Assumptions about the Data Generating Mechanism

Process monitoring (PM) for nuclear safeguards sometimes requires estimation of thresholds corresponding to small false alarm rates. Threshold estimation dates to the 1920s with the Shewhart control chart; however, because possible new roles for PM are being evaluated in nuclear safeguards, it is timely to consider modern model selection options in the context of threshold estimation. One of the possible new PM roles involves PM residuals, where a residual is defined as residual = data − prediction. This paper reviews alarm threshold estimation, introduces model selection options, and considers a range of assumptions regarding the data-generating mechanism for PM residuals. Two PM examples from nuclear safeguards are included to motivate the need for alarm threshold estimation. The first example involves mixtures of probability distributions that arise in solution monitoring, which is a common type of PM. The second example involves periodic partial cleanout of in-process inventory, leading to challenging structure in the time series of PM residuals.

Burr, Tom↗

Relative humidity threshold for oxygen generation by high-purity plutonium dioxides in 3013 containers

High-purity plutonium dioxide with adsorbed water in a sealed container can generate oxygen, but oxygen will not be generated in low water loading conditions. A threshold for oxygen generation has been observed in the hydrogen generation rate normalized by the specific power for high-purity plutonium dioxide. Normalized hydrogen generation rates above this threshold generate oxygen and below the threshold consume oxygen. The threshold rate is determined by the amount of water adsorbed onto the surface of the oxide. The relative humidity of the atmosphere that the oxide is in equilibrium with determines the amount of physisorbed water adsorbed on the surface. We calculate the relative humidity corresponding to the threshold rate as a function of mass and specific surface area of material stored in 3013 containers. Exceeding the calculated relative humidity may result in flammable gas mixtures of hydrogen and oxygen at some time during storage.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurement and interpretation of threshold stress intensity factors for steels in high-pressure hydrogen gas.

Threshold stress intensity factors were measured in high-pressure hydrogen gas for a variety of low alloy ferritic steels using both constant crack opening displacement and rising crack opening displacement procedures. The sustained load cracking procedures are generally consistent with those in ASME Article KD-10 of Section VIII Division 3 of the Boiler and Pressure Vessel Code, which was recently published to guide design of high-pressure hydrogen vessels. Three definitions of threshold were established for the two test methods: K{sub THi}* is the maximum applied stress intensity factor for which no crack extension was observed under constant displacement; K{sub THa} is the stress intensity factor at the arrest position for a crack that extended under constant displacement; and K{sub JH} is the stress intensity factor at the onset of crack extension under rising displacement. The apparent crack initiation threshold under constant displacement, K{sub THi}*, and the crack arrest threshold, K{sub THa}, were both found to be non-conservative due to the hydrogen exposure and crack-tip deformation histories associated with typical procedures for sustained-load cracking tests under constant displacement. In contrast, K{sub JH}, which is measured under concurrent rising displacement and hydrogen gas exposure, provides a more conservative hydrogen-assisted fracture threshold that is relevant to structural components in which sub-critical crack extension is driven by internal hydrogen gas pressure.

08 HYDROGEN↗

A Novel Method for Setting Meaningful Thresholds for RMS-Energy Oscillation Detectors

Oscillation detection and mitigation is a crucial aspect of reliable power system operation. Several transmission system operators and reliability coordinators use the RMS-energy method of oscillation detection, but the process of setting thresholds is time and labor intensive. The current industry practice in the United States is to set thresholds based on the RMS-energy's value during ambient conditions, which can often lead to nuisance alarms that require thresholds to be manually retuned. In this paper, we propose a method for setting RMS-energy thresholds that directly accounts for oscillation amplitudes specified by the user. A theoretical analysis of the statistical properties of the RMS-energy incorporates these user-specified amplitudes, resulting in thresholds that reliably detect oscillations of interest while avoiding nuisance alarms. Theoretical results are validated with simulated measurements and the real-world practicality of the method is established with publicly available field-measured data from the Grid Event Signature Library.

Follum, James D.↗

Threshold kinetic processes for t-C4F9I

To determine the relative threshold of the lasant gas t-C4F9I in comparison to n-C3F7I, the pump energy to reach threshold for photodissociation iodine lasing is measured in a common aparatus. The comparison is made for the threshold energies in the iodide pressure range up to 50 Torr when 64-J electric input into a flashlamp is used for pumping. It is shown from the results that qualitative differences between the thresholds of the two gases result from the degree to which steady state is achieved by the time threshold is reached. The estimated recombination rate for t-C4F9I is found to be much larger than the value given by Ershov et al (1978).

Lee, J. H.↗

High-power low-threshold graded-index separate confinement heterostructure AlGaAs single quantum well lasers on Si substrates

A high-power low-threshold graded-index separate confinement heterostructure AlGaAs single quantum well laser on Si substrates has been demonstrated for the first time by a hybrid growth of migration-enhanced molecular beam epitaxy followed by metalorganic vapor phase epitaxy. The quantum well laser showed an output power of more than 400 mW per facet under pulsed conditions. A room-temperature threshold current of 300 mA was obtained with a differential quantum efficiency of 40 percent without facet coating. The threshold current density was 550 A/sq cm for a cavity length of 500 microns. These results show the highest peak power reported to date for low-threshold lasers on Si substrates. The full width at half maximum of the far-field pattern parallel to the junction was 6 deg. Threshold current densities as low as 250 A/sq cm were obtained for lasers on GaAs substrates.

Kim, Jae-Hoon↗

An analysis of the threshold method for measuring area-average rainfall

Experimental evidence shows that the area-average rain rate and the fractional area covered by rain rate exceeding a fixed threshold are highly correlated; that is, are highly linearly related. A precise theoretical explanation of this fact is given. The explanation is based on the observation that rain rate has a mixed distribution, one that is a mixture of a discrete distribution and a continuous distribution. Under a homogeneity assumption, the slope of the linear relationship depends only on the continuous part of the distribution and as such is found to be markedly immune to parameter changes. This is illustrated by certain slope surfaces obtained from three specific distributions. The threshold level can be chosen in an optimal way by minimizing a certain distance function defined over the threshold range. In general, the threshold level should be not too far from the mean rain rate conditional on rain. The so-called threshold method advocates measuring rainfall from fractional area exploiting the observed linear relationship of the later with the area average rain rate. The method is potentially useful for the estimation of rainfall from space via satellites.

Kedem, Benjamin↗

An experiment on the threshold effect in the coherent wave instability

Results are reported from an experimental study of the threshold effect in the coherent wave instability in which a combination of simulated VLF noise 200 Hz wide, superimposed on a variable amplitude constant frequency test signal (about 3 kHz) is transmitted from Siple Station, Antarctica, and received at Lake Mistissini, Quebec. As the test signal is slowly ramped up in power a 'threshold' level at which growth and triggering of emissions begin (coherent wave instability) is reached. It is shown that sufficiently strong simulated noise supresses the coherent wave instability, which corresponds to increasing the threshold level. This experiment is repeated at progressively lower levels of the simulated noise, until the threshold level for growth and triggering on the test signal no longer changes. At this point the simulated noise power is estimated to equal typical background noise levels due to magnetospheric hiss in the interaction region. It is suggested that unducted magnetospheric hiss is responsible for the threshold effect.

Mielke, T. A.↗

Investigation of Adaptive-threshold Approaches for Determining Area-Time Integrals from Satellite Infrared Data to Estimate Convective Rain Volumes

The principal goal of this project is to establish relationships that would allow application of area-time integral (ATI) calculations based upon satellite data to estimate rainfall volumes. The research is being carried out as a collaborative effort between the two participating organizations, with the satellite data analysis to determine values for the ATIs being done primarily by the STC-METSAT scientists and the associated radar data analysis to determine the 'ground-truth' rainfall estimates being done primarily at the South Dakota School of Mines and Technology (SDSM&T). Synthesis of the two separate kinds of data and investigation of the resulting rainfall-versus-ATI relationships is then carried out jointly. The research has been pursued using two different approaches, which for convenience can be designated as the 'fixed-threshold approach' and the 'adaptive-threshold approach'. In the former, an attempt is made to determine a single temperature threshold in the satellite infrared data that would yield ATI values for identifiable cloud clusters which are closely related to the corresponding rainfall amounts as determined by radar. Work on the second, or 'adaptive-threshold', approach for determining the satellite ATI values has explored two avenues: (1) attempt involved choosing IR thresholds to match the satellite ATI values with ones separately calculated from the radar data on a case basis; and (2) an attempt involved a striaghtforward screening analysis to determine the (fixed) offset that would lead to the strongest correlation and lowest standard error of estimate in the relationship between the satellite ATI values and the corresponding rainfall volumes.

Smith, Paul L.↗

The Relationship Between Area-Time Integrals Determined from Satellite Infrared Data by Means of a Fixed-Threshold Approach and Convective Rainfall Volumes

The relationship of the rainfall from convective clouds to area-time integrals determined from satellite infrared data using a fixed infrared-temperature threshold is investigated. Concurrent radar and rapid-scan satellite data obtained during field projects in the northern High Plains and the southeastern United States were used in this study. The fixed IR threshold appropriate for each region was determined by an optimization procedure that identified the brightness threshold that yields the strongest relationship between estimated rainfall from a cloud cluster and its satellite Area-Time Integral (ATI) for each dataset. For the North Dakota-Montana area the optimization procedure indicated that the area enclosed by the -22.5 C isotherm provides satellite ATI values most closely related to the estimated rainfalls. For the southeastern United States project, the optimized tem- perature threshold was 8.5'C. The difference between the thresholds determined for the two geographic areas suggests that a different 'calibration' for each distinct area may be needed to make use of this relationship. Slopes of the two log-log rainfall-ATI regressions are less than unity, indicating that a relative horizontal expansion and/or increase in persistence of a cloud cluster exceeds the associated increase in precipitation. Implications for the Geostationary Operational Environmental Satellite precipitation index are discussed. New results concerning the rain volume-radar ATI relationship for the southeastern United States are also appended to the paper.

Johnson, L. Ronald↗