Search NASA⌕ Search

SEARCH · Search NASA

Results for “TIME”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

SU-E-I-88: The Effect of System Dead Time On Real-Time Plastic and GOS Based Fiber-Optic Dosimetry Systems

Purpose: A methodology is presented to correct for measurement inaccuracies at high detector count rates using a plastic and GOS scintillation fibers coupled to a photomultiplier tube with digital readout. This system allows temporal acquisition and manipulation of measured data. Methods: The detection system used was a plastic scintillator and a separate gadolinium scintillator, both (0.5 diameter) coupled to an optical fiber with a Hamamatsu photon counter with a built-in microcontroller and digital interface. Count rate performance of the system was evaluated using the nonparalzable detector model. Detector response was investigated across multiple radiation sources including: orthovoltage x-ray system, colbat-60 gamma rays, proton therapy beam, and a diagnostic radiography x-ray tube. The dead time parameter was calculated by measuring the count rate of the system at different exposure rates using a reference detector. Results: The system dead time was evaluated for the following sources of radiation used clinically: diagnostic energy x-rays, cobalt-60 gamma rays, orthovoltage xrays, particle proton accelerator, and megavoltage x-rays. It was found that dead time increased significantly when exposing the detector to sources capable of generating Cerenkov radiation, all of the sources sans the diagnostic x-rays, with increasing prominence at higher photon energies. Percent depth dose curves generated by a dedicated ionization chamber and compared to the detection system demonstrated that correcting for dead time improves accuracy. On most sources, nonparalzable model fit provided an improved system response. Conclusion: Overall, the system dead time was variable across the investigated radiation particles and energies. It was demonstrated that the system response accuracy was greatly improved by correcting for dead time effects. Cerenkov radiation plays a significant role in the increase in the system dead time through transient absorption effects attributed to electron hole-pair creations within the optical waveguide.

07 ISOTOPE AND RADIATION SOURCES↗

Ultrafast Space-time and Spectrum-time Resolved Diagnostics of Multicharged Femtosecond Laser Microplasma

We present the review of the recent experimental studies of fundamental mechanisms of femtosecond laser plasma formation and evolution performed in A. M. Prokhorov General Physics Institute of Russian Academy of Sciences. The main object we dealt with was the micro-sized plasma produced in gases with high intensity (up to 5x10{sup 17} W/cm{sup 2}), tightly focused (to a few microns in diameter) IR and UV femtosecond laser pulses. The main attention in the experiments was paid to the initial stage of microplasma formation and evolution characterized by strong laser-plasma coupling resulting in efficient ionization and heating of the medium, distortion of laser beam, and nonlinear spectral conversion of laser radiation to the continuum and laser harmonics. Using a precise pump-probe micro-interferometric technique the dynamics of plasma was studied with femtosecond time-resolution in a wide density range--from a minimal detectable electron concentration (10{sup 19} cm{sup -3}) to the almost total (down to nuclei) ionization of ions occurred under femtosecond excitation. The obtained time-dependences of plasma density were analyzed. It was observed, for the first time, that a characteristic time of femtosecond laser plasma formation in gases considerably (in times) exceeds the duration of the pump laser pulse. This postionization process is attributed to impact ionization of plasma by hot electrons. We compare the results of the experiments with what the developed theory predicts. Using an ultrafast streak-camera-based spectroscopy technique the temporal evolution of microplasma emission and the dynamics of spectral lines formation in UV-visible range were studied with picosecond time-resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the late-time growth of the two-dimensional Richtmyer–Meshkov instability in shock tube experiments [On the late-time growth of the 2D Richtmyer–Meshkov instability in shock tube experiments]

In the present study, shock tube experiments are used to study the very late-time development of the Richtmyer–Meshkov instability from a diffuse, nearly sinusoidal, initial perturbation into a fully turbulent flow. The interface is generated by two opposing gas flows and a perturbation is formed on the interface by transversely oscillating the shock tube to create a standing wave. The puncturing of a diaphragm generates a Mach $1. 2$ shock wave that then impacts a density gradient composed of air and SF 6 , causing the Richtmyer–Meshkov instability to develop in the 2.0 m long test section. The instability is visualized with planar Mie scattering in which smoke particles in the air are illuminated by a Nd:YLF laser sheet, and images are recorded using four high-speed video cameras operating at 6 kHz that allow the recording of the time history of the instability. In addition, particle image velocimetry (PIV) is implemented using a double-pulsed Nd:YAG laser with images recorded using a single CCD camera. Initial modal content, amplitude, and growth rates are reported from the Mie scattering experiments while vorticity and circulation measurements are made using PIV. Amplitude measurements show good early-time agreement but relatively poor late-time agreement with existing nonlinear models. The model of Goncharov agrees with growth rate measurements at intermediate times but fails at late experimental times. Measured background acceleration present in the experiment suggests that the late-time growth rate may be influenced by Rayleigh–Taylor instability induced by the interfacial acceleration. Numerical simulations conducted using the LLNL codes Ares and Miranda show that this acceleration may be caused by the growth of boundary layers, and must be accounted for to produce good agreement with models and simulations. Adding acceleration to the Richtmyer–Meshkov buoyancy–drag model produces improved agreement. It is found that the growth rate and amplitude trends are also modelled well by the Likhachev–Jacobs vortex model. Here, circulation measurements also show good agreement with the circulation value extracted by fitting the vortex model to the experimental data.

42 ENGINEERING↗

Influence of Hydrogen Plasma Treatment Time to Si:H Layer Deposition Time Ratio on the Properties of Layer-by-Layer Deposited Hydrogenated Silicon (Si:H) Thin Films

Hydrogenated silicon (Si-H) thin films were deposited from a mixture of pure silane (SiH{sub 4}) and hydrogen (H{sub 2}) gases in a home-built plasma enhanced chemical vapour deposition (PECVD) system using the layer-by-layer (LBL) deposition technique. In the LBL process, the deposition was performed by periodically alternating the deposition of Si:H layer with the hydrogen treatment process of the growth surface. In this work, the effects of the H plasma treatment time to Si-H layer growth time ratio on the film properties were studied. The LBL deposited Si-H films studied in this work were deposited using different Si-H layer growth times ranging from 2 minutes to 7 minutes with the hydrogen plasma treatment time on the growth surface fixed at 3 minutes. Optical transmission spectroscopy, X-ray diffraction (XRD), micro-Raman scattering spectroscopy, Fourier transform infrared (FTIR) spectroscopy and atomic force microscopy (AFM) measurements were done on these films to investigate the optical, structural and morphological properties of the films. The films deposited by this technique produced the highest deposition rate of 6.3 A ring /s when the growth time of the Si-H layer was fixed at 5 minutes. These films were amorphous in structure and had large optical energy gaps irrespective of the Si-H layer deposition time. High concentration of cone-like structures was observed in the AFM images for the films deposited using the higher Si-H layer deposition times.

36 MATERIALS SCIENCE↗

A parameter free prediction of simulated crystal nucleation times in the Lennard-Jones system: from steady state nucleation to the transient-time regime

Large scale simulations of crystal nucleation from the liquid are performed using the Lennard-Jones potential, to determine the time required for nucleation. By considering both transient and finite-size effects, we successfully predict the nucleation time within order of magnitude without any parameter fitting. All necessary parameters are derived from separate, equilibrium simulations. At smaller undercoolings, large system sizes are required, not only to accommodate large critical nuclei, but also to control statistical effects that are controlled by the density of critical nuclei. Two distinct nucleation regions are observed in the simulations, which are dominated by transient time and steady state nucleation time, respectively. At deep undercoolings, we still show consistency between predicted transient times and simulated nucleation times, which suggests that the short nucleation times in simulations are due to a small barrier to nucleation, rather than spinodal transformation that have been previously predicted. We compare with similar, previous results on a model of Al, which does not show such rapid nucleation at low temperatures, and suggest that the differences are due to the behavior of the reduced barrier G*/kBT.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Precision Timing with the CMS MIP Timing Detector

The Compact Muon Solenoid (CMS) detector at the CERN Large Hadron Collider (LHC) is undergoing an extensive Phase II upgrade program to prepare for the challenging conditions of the High Luminosity LHC (HL-LHC). A new timing layer is designed to measure minimum ionizing particles (MIPs) with a time resolution of 30 ps and hermetic coverage up to a pseudo-rapidity of |η|=3. This MIP Timing Detector (MTD) will consist of a central barrel region based on LYSO:Ce crystals read out with SiPMs and two end-caps instrumented with radiation-tolerant Low Gain Avalanche Detectors (LGADs). The precision time information from the MTD will reduce the effects of the high levels of pile-up expected at the HL-LHC and will bring new and unique capabilities to the CMS detector. The time information assigned to each track will enable the use of 4D-vertexing which will render a 5-fold pile-up reduction thus recovering the current conditions. Precision timing will also enable new time-based isolations and improved b-tagging algorithms. All of this translates into a 20% gain in effective luminosity when looking at di-Higgs boson events decaying to a pair of b-quarks and two photons. We present the current status and ongoing R&D of the MTD, including implications on the physics reach at the HL-LHC and test beam results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact representation and long-time extrapolation of real-time data for quantum systems using the ESPRIT algorithm

Representing real-time data as a sum of complex exponentials provides a compact form that enables both denoising and extrapolation. As a fully data-driven method, the Estimation of Signal Parameters via Rotational Invariance Techniques (ESPRIT) algorithm is agnostic to the underlying physical equations, making it broadly applicable to various observables and experimental or numerical setups. In this work, we consider applications of the ESPRIT algorithm primarily to extend real-time dynamical data from simulations of quantum systems. We evaluate ESPRIT's performance in the presence of noise and compare it to other extrapolation methods. We demonstrate its ability to extract information from short-time dynamics to reliably predict long-time behavior and determine the minimum time interval required for accurate results. We discuss how this insight can be leveraged in numerical methods that propagate quantum systems in time, and we show how ESPRIT can predict infinite-time values of dynamical observables, offering a purely data-driven approach to characterizing quantum phases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Instrumentation and methods for efficient time-resolved X-ray crystallography of biomolecular systems with sub-10 ms time resolution

Time-resolved X-ray crystallography has great promise to illuminate structure–function relations and key steps of enzymatic reactions with atomic resolution. The dominant methods for chemically-initiated reactions require complex instrumentation at the X-ray beamline, significant effort to operate and maintain this instrumentation, and enormous numbers (∼10 5 –10 9 ) of crystals per time point. We describe instrumentation and methods that enable high-throughput time-resolved study of biomolecular systems using standard crystallography sample supports and mail-in X-ray data collection at standard high-throughput cryocrystallography synchrotron beamlines. The instrumentation allows rapid reaction initiation by mixing of crystals and substrate/ligand solution, rapid capture of structural states via thermal quenching with no pre-cooling perturbations, and yields time resolutions in the single-millisecond range, comparable to the best achieved by any non-photo-initiated method in both crystallography and cryo-electron microscopy. Our approach to reaction initiation has the advantages of simplicity, robustness, low cost, adaptability to diverse ligand solutions and small minimum volume requirements, making it well suited to routine laboratory use and to high-throughput screening. We report the detailed characterization of instrument performance, present structures of binding of N -acetylglucosamine to lysozyme at time points from 8 ms to 2 s determined using only one crystal per time point, and discuss additional improvements that will push time resolution toward 1 ms.

Indergaard, John A. (ORCID:000000022367699X)↗

SALSA3D: A Tomographic Model of Compressional Wave Slowness in the Earth’s Mantle for Improved Travel-Time Prediction and Travel-Time Prediction Uncertainty

The task of monitoring the Earth for nuclear explosions relies heavily on seismic data to detect, locate, and characterize suspected nuclear tests. In this study, motivated by the need to locate suspected explosions as accurately and precisely as possible, we developed a tomographic model of the compressional wave slowness in the Earth’s mantle with primary focus on the accuracy and precision of travel-time predictions for P and Pn ray paths through the model. Path-dependent travel-time prediction uncertainties are obtained by computing the full 3D model covariance matrix and then integrating slowness variance and covariance along ray paths from source to receiver. Path-dependent travel-time prediction uncertainties reflect the amount of seismic data that was used in tomography with very low values for paths represented by abundant data in the tomographic data set and very high values for paths through portions of the model that were poorly sampled by the tomography data set. The pattern of travel-time prediction uncertainty is a direct result of the off-diagonal terms of the model covariance matrix and underscores the importance of incorporating the full model covariance matrix in the determination of travel-time prediction uncertainty. In addition, the computed pattern of uncertainty differs significantly from that of 1D distance-dependent travel-time uncertainties computed using traditional methods, which are only appropriate for use with travel times computed through 1D velocity models.

58 GEOSCIENCES↗

Reformulation of the relativistic conversion between coordinate time and atomic time

The relativistic conversion between coordinate time and atomic time is reformulated to allow simpler time calculations relating analysis in solar system barycentric coordinates (using coordinate time) with earth-fixed observations (measuring 'earth-bound' proper time or atomic time). After an interpretation in terms of relatively well-known concepts, this simplified formulation, which has a rate accuracy of about 10 to the minus 15th, is used to explain the conventions required in the synchronization of a worldwide clock network and to analyze two synchronization techniques - portable clocks and radio interferometry. Finally, pertinent experimental tests of relativity are briefly discussed in terms of the reformulated time conversion.

Thomas, J. B.↗

Analysis of vector wind change with respect to time for Cape Kennedy, Florida: Wind aloft profile change vs. time, phase 1

Wind vector change with respect to time at Cape Kennedy, Florida, is examined according to the theory of multivariate normality. The joint distribution of the four variables represented by the components of the wind vector at an initial time and after a specified elapsed time is hypothesized to be quadravariate normal; the fourteen statistics of this distribution, calculated from fifteen years of twice daily Rawinsonde data are presented by monthly reference periods for each month from 0 to 27 km. The hypotheses that the wind component changes with respect to time is univariate normal, the joint distribution of wind component changes is bivariate normal, and the modulus of vector wind change is Rayleigh, has been tested by comparison with observed distributions. Statistics of the conditional bivariate normal distributions of vector wind at a future time given the vector wind at an initial time are derived. Wind changes over time periods from one to five hours, calculated from Jimsphere data, are presented.

Adelfang, S. I.↗

Discrete-time stability of continuous-time controller designs for large space structures

In most of the stable control designs for flexible structures, continuous time is assumed. However, in view of the implementation of the controllers by on-line digital computers, the discrete-time stability of such controllers is an important consideration. In the case of direct-velocity feedback (DVFB), involving negative feedback from collocated force actuators and velocity sensors, it is not immediately apparent how much delay due to digital implementation of DVFB can be tolerated without loss of stability. The present investigation is concerned with such questions. A study is conducted of the discrete-time stability of DVFB, taking into account an employment of Euler's method of approximation of the time derivative. The obtained result gives an indication of the acceptable time-step size for stable digital implementation of DVFB. A result derived in connection with the consideration of the discrete-time stability of stable continuous-time systems provides a general condition under which digital implementation of such a system will remain stable.

Balas, M. J.↗

A note on some statistical properties of rise time parameters used in muon arrival time measurements

Most investigations of the muon arrival time distribution in EAS during the past decade made use of parameters which can collectively be called rise time parameters. The rise time parameter T sub A/B is defined as the time taken for the integrated pulse from a detector to rise from A% to B% of its full amplitude. The use of these parameters are usually restricted to the determination of the radial dependence thereof. This radial dependence of the rise time parameters are usually taken as a signature of the particle interaction characteristics in the shower. As these parameters have a stochastic nature, it seems reasonable that one should also take notice of this aspect of the rise time parameters. A statistical approach to rise time parameters is presented.

Vanderwalt, D. J.↗

Ground-based time-guidance algorithm for control of airplanes in a time-metered air traffic control environment: A piloted simulation study

The rapidly increasing costs of flight operations and the requirement for increased fuel conservation have made it necessary to develop more efficient ways to operate airplanes and to control air traffic for arrivals and departures to the terminal area. One concept of controlling arrival traffic through time metering has been jointly studied and evaluated by NASA and ONERA/CERT in piloted simulation tests. From time errors attained at checkpoints, airspeed and heading commands issued by air traffic control were computed by a time-guidance algorithm for the pilot to follow that would cause the airplane to cross a metering fix at a preassigned time. These tests resulted in the simulated airplane crossing a metering fix with a mean time error of 1.0 sec and a standard deviation of 16.7 sec when the time-metering algorithm was used. With mismodeled winds representing the unknown in wind-aloft forecasts and modeling form, the mean time error attained when crossing the metering fix was increased and the standard deviation remained approximately the same. The subject pilots reported that the airspeed and heading commands computed in the guidance concept were easy to follow and did not increase their work load above normal levels.

Knox, C. E.↗

Quantification of reaction time and time perception during Space Shuttle operations

A microprocessor-based test battery containing simple reaction time, choice reaction time, and time perception tasks was flown aboard a 1985 Space Shuttle flight. Data were obtained from four crew members. Individual subject means indicate a correlation between change in reaction time during the flight and the presence of space motion sickness symptoms. The time perception task results indicate that the shortest duration task time (2 s) is progressively overestimated as the mission proceeds and is statistically significant when comparing preflight and postflight baselines. The tasks that required longer periods of time to estimate (8, 12, and 16 s) are less affected.

Ratino, D. A.↗

Time-locked time-histories - A new way of examining eye-movement data

A problem often encountered when eye-movement measurement is conducted is the choice of 'indices' or 'statistics' available to present such information. The present study reports the use of the Time-Locked Time-History as a technique of value in the examination and presentation of eye-movement data. Plots created using this technique are labeled time-locked time-histories as they illustrate subject eye lookpoint during a period of time before and after a certain time-locking event. Events that occur with some degree of repetition, such as the onset or termination of control activities, warning signals, or changes in indicator positions may be utilized as time-locking events. The present study reports the use of this technique in an eye-movement study using a secondary task in which the subject must discriminate specific types of information in the display.

Comstock, J. Raymond, Jr.↗

Delivery performance of conventional aircraft by terminal-area, time-based air traffic control: A real-time simulation evaluation

A description and results are presented of a study to measure the performance and reaction of airline flight crews, in a full workload DC-9 cockpit, flying in a real-time simulation of an air traffic control (ATC) concept called Traffic Intelligence for the Management of Efficient Runway-scheduling (TIMER). Experimental objectives were to verify earlier fast-time TIMER time-delivery precision results and obtain data for the validation or refinement of existing computer models of pilot/airborne performance. Experimental data indicated a runway threshold, interarrival-time-error standard deviation in the range of 10.4 to 14.1 seconds. Other real-time system performance parameters measured include approach speeds, response time to controller turn instructions, bank angles employed, and ATC controller message delivery-time errors.

Credeur, Leonard↗

GPS/Loran-C interoperability for time and frequency applications: A survey of the times of arrival of Loran-C transmissions via GPS common mode/common view satellite observations

The results from this survey clearly indicate that the Global Positioning System (GPS) time transfer capability is superior to that of the Loran-C system for absolute timing accuracy, and that even with the most careful calibration of the Loran-C receiver delay and propagation path, inexplicable time of arrival (TOA) biases remain which are larger than the variations across all of the transmitters. Much more data covering years would be needed to show that these biases were stable enough to be removed with a one time site calibration. The synchronization of the transmissions is excellent, all showing low parts in 10(exp 13) offsets versus the United States Naval Observatory (USNO) master clock. With the exception of the Searchlight transmitter, all of the transmissions exhibit timing stabilities over the entire period of less than 300 ns RMS which is at the observed levels of GPS under selective availability (SA). The Loran-C phase instabilities take place over a much greater time interval than those being forced onto the GPS signals under SA, providing for better medium to short term frequency stability. Data show that all but the most distant transmitters offer better than three parts in 10(exp 11) stability at this averaging time. It is in the frequency control area where GPS/Loran-C interoperation will offer some synergistic advantages over GPS alone under SA.

Penrod, Bruce↗