Controlled nitric oxide production via O( 1 D) + N 2 O reactions for use in oxidation flow reactor studies

Oxidation flow reactors that use low-pressure mercury lamps to produce hydroxyl (OH) radicals are an emerging technique for studying the oxidative aging of organic aerosols. Here, ozone (O 3 ) is photolyzed at 254 nm to produce O( 1 D) radicals, which react with water vapor to produce OH. However, the need to use parts-per-million levels of O 3 hinders the ability of oxidation flow reactors to simulate NO x -dependent secondary organic aerosol (SOA) formation pathways. Simple addition of nitric oxide (NO) results in fast conversion of NO x (NO + NO 2 ) to nitric acid (HNO 3 ), making it impossible to sustain NO x at levels that are sufficient to compete with hydroperoxy (HO 2 ) radicals as a sink for organic peroxy (RO 2 ) radicals. We developed a new method that is well suited to the characterization of NO x -dependent SOA formation pathways in oxidation flow reactors. NO and NO 2 are produced via the reaction O( 1 D) + N 2 O → 2NO, followed by the reaction NO + O 3 → NO 2 + O 2 . Laboratory measurements coupled with photochemical model simulations suggest that O( 1 D) + N 2 O reactions can be used to systematically vary the relative branching ratio of RO 2 + NO reactions relative to RO 2 + HO 2 and/or RO 2 + RO 2 reactions over a range of conditions relevant to atmospheric SOA formation. We demonstrate proof of concept using high-resolution time-of-flight chemical ionization mass spectrometer (HR-ToF-CIMS) measurements with nitrate (NO 3 − ) reagent ion to detect gas-phase oxidation products of isoprene and α -pinene previously observed in NO x -influenced environments and in laboratory chamber experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Controlled Nitric Oxide Production via O(1D) + N2O Reactions for Use in Oxidation Flow Reactor Studies

Oxidation flow reactors that use low-pressure mercury lamps to produce hydroxyl (OH) radicals are an emerging technique for studying the oxidative aging of organic aerosols. Here, ozone (O3) is photolyzed at 254 nm to produce O(1D) radicals, which react with water vapor to produce OH. However, the need to use parts-per-million levels of O3 hinders the ability of oxidation flow reactors to simulate NOx-dependent secondary organic aerosol (SOA) formation pathways. Simple addition of nitric oxide (NO) results in fast conversion of NOx (NO+NO2) to nitric acid (HNO3), making it impossible to sustain NOx at levels that are sufficient to compete with hydroperoxy (HO2) radicals as a sink for organic peroxy (RO2) radicals. We developed a new method that is well suited to the characterization of NOx-dependent SOA formation pathways in oxidation flow reactors. NO and NO2 are produced via the reaction O(1D)+N2O->2NO, followed by the reaction NO+O3->NO2+O2. Laboratory measurements coupled with photochemical model simulations suggest that O(1D)+N2O reactions can be used to systematically vary the relative branching ratio of RO2 +NO reactions relative to RO2 +HO2 and/or RO2+RO2 reactions over a range of conditions relevant to atmospheric SOA formation. We demonstrate proof of concept using high-resolution time-of-flight chemical ionization mass spectrometer (HR-ToF-CIMS) measurements with nitrate (NO-3 ) reagent ion to detect gas-phase oxidation products of isoprene and -pinene previously observed in NOx-influenced environments and in laboratory chamber experiments.

Lambe, Andrew↗

ToF-SIMS spectral analysis of pristine and neutron irradiated single crystal tungsten

Time-of-flight secondary ion mass spectrometry (ToF-SIMS) has many promising features in studying materials including high spatial resolution and high mass accuracy of elements, molecules, and isotopes. Its ability to resolve isotopes is especially attractive in studying transmutation products of single crystal tungsten (SCW) post neutron irradiation. Tungsten (W) is a contender of plasma facing materials (PFMs) due to its high thermal and radiological stability. PFMs to be used in the construction of fusion vessels are subject to high temperature and neutron irradiation, resulting in changes to materials including transmutation, which ultimately impact material mechanical and thermal properties. We used IONTOF TOF.SIMS V instrument equipped with a 30 keV Bi 3 + primary ion beam to study pristine SCW and irradiated SCW speciemens. Scanning electron microscope coupled with focused ion beam (SEM-FIB) was used to reduce the dosage of neutron irradiated tungsten and prepare for specimens for SIMS analysis. Static ToF-SIMS spectra were obtained, and transmutation product peak identification was presented in this work. Identified molecules and molecular fragments were compared against isotope theoretical mass to charge ratios of tungsten, rhenium, osmium, and other relevant products. Our results show that ToF-SIMS provides a viable means to study transmutation products of W post neutron irradiation. Such applications are suitable to investigate transmutation effects on materials that are being considered and developed for fusion pilot plants.

36 MATERIALS SCIENCE↗

Neutron Capture Measurements at the n lowbar TOF Facility

Nuclear astrophysics, advanced nuclear technology and nuclear structure physics present many cases that require neutron capture reaction data with high precision. In particular, refined data are needed for stellar nucleosynthesis, for nuclear waste transmutation studies, and for the design of generation IV reactors. The measurements take profit of the pulsed neutron beam of the n lowbar TOF facility at CERN, which is generated by proton-induced spallation reactions on a massive lead target. The low repetition rate of the proton beam, the high instantaneous neutron flux, and the favourable background conditions in the experimental area make this facility unique for high resolution time-of-flight measurements of neutron induced reaction cross sections. The n lowbar TOF collaboration is presently operating two different experimental set-ups. The first consists of two low-neutron sensitivity C{sub 6}D{sub 6} detectors with the analysis relying on the Pulse Height Weighting technique. In addition, a Total Absorption Calorimeter, consisting of 40 BaF{sub 2} crystals covering the whole solid angle, was used. A review of several capture measurements with these detectors on selected stable and unstable samples will be presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-resolution reflecting time-of-flight momentum and energy mapping system

A new system to map electron momentum and energy is proposed. A reflecting electrode is introduced into a time-of-flight (TOF) system whose decelerating electric field sends all the electrons back to a position-sensitive detector close to but behind the source of the electrons. The longer flying distance that results makes it possible to significantly improve the energy-resolved performance, especially in the higher energy region. The dependence of the new TOF system on its characteristic parameters is analyzed, along with its application to attosecond streak cameras. Experimental results verified a relative energy resolution better than 0.2 eV for 22 eV electrons and also revealed the availability of the improved relative energy resolution smaller than 1.0% for electron energy ranging from 30 to 40 eV.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Congruence of Clusters Defined By Whole Genome Sequencing and MALDI-TOF for Bacteria Isolated From Cleanrooms

Introduction: Oligotrophic conditions can render cleanrooms inhospitable to microbes. Despite these constraints, fungi and bacteria are frequently isolated from surfaces in astromaterials cleanrooms at the Johnson Space Center. Bacillus species are of particular concern because endospores belonging to this genus are resilient and can affect astromaterials. Current monitoring programs rely on 16S rRNA sequencing and the VITEK2 Compact system. These methods have limited power to resolve Bacillus species. Matrix-assisted laser desorption - time of flight mass spectrometry (MALDI-TOF MS), provides a rapid, low cost, method of identifying bacterial isolates and has a higher resolution than 16S rRNA sequencing, particularly for Bacillus species; however, few studies have compared this method to the industry gold standard, whole genome sequencing (WGS). Methods: Based on 16S rRNA classification, we selected 14 isolates for analysis with MALDI-TOF and WGS. Mass spectra were generated with MALDI-TOF MS and processed with custom scripts to identify clusters of closely related isolates and calculate a matrix of pairwise cosine similarity scores. Hybrid Illumina and Nanopore sequencing were used to generate draft genomes. Pairwise similarity scores were calculated from these genomes based on the average amino acid identity (AAI) predicted from single copy core genes. Congruence of clustering between these methods, was assessed by calculating adjusted Rand and Wallace coefficients. Results: Clusters of species generated from MALDI-TOF MS showed good agreement of phylotypes generated with WGS. Pairs of strains that were > 94% similar to each other in terms of predicted amino acid sequences consistently showed cosine similarities of mass spectra > 0.65 and, of the 9 clusters identified with WGS, 8 were identical with MALDI-TOF. This corresponds to an adjusted Rand index of 0.95 and a 95% confidence interval of 0.80 – 1.00 for adjusted Wallace coefficients. The only discordance was for a pair of isolates that were classified as Paenibacillus species. This pair showed relatively high similarity (0.84) in terms of MALDI-TOF MS but only 85% similarity in terms of AAI. Conclusion: This study shows that MALDI-TOF and WGS exhibit a similar ability to delineate Bacillus species isolated from cleanrooms and taxonomic units described by these two methods are consistent with one another. Since MALDI-TOF MS is low in cost and high in throughput, this approach appears to be an ideal option for routine microbial monitoring and identifying Bacillus species.

Farnaz Mazhari↗

Combining ToF‐SIMS and Multivariate Analysis to Resolve Active Sites on Ni‐Based HER Catalysts

Unambiguous identification of active sites in heterogeneous catalysis remains a major challenge, particularly for materials with ultrathin, chemically mixed surface layers. Here, we demonstrate a generalizable approach that combines time-of-flight secondary ion mass spectrometry (ToF-SIMS) with multivariate statistical analysis (principal component analysis [PCA] and multivariate curve resolution [MCR]) to resolve catalytically relevant motifs at the nanoscale. Using Ni electrodes as a model system, PCA distinguished hydroxide-enriched domains from oxide- and metal-rich regions, while MCR decomposed depth profiles and 3D images into hydroxide, oxide, and metallic layers with nanometer resolution. A unique secondary-ion fragment, NiO 3 H 3 − (m/z 108.94), emerged as a marker of hydroxide-rich environments and correlated with hydrogen evolution reaction (HER) activity across a series of Ni electrodes. Complementary density functional theory (DFT) calculations revealed that Ni(OH) 2 clusters adjacent to metallic Ni offer the most favorable water dissociation energetics, establishing the structural origin of the marker. While illustrated here for Ni-based HER, this workflow provides a broadly applicable framework to isolate and rank near-surface patterns that govern catalytic activity, thereby extending ToF-SIMS from a qualitative probe to a predictive tool for active site identification.

HER active sites↗

Low power implementation of high frequency SiPM readout for Cherenkov and scintillation detectors in TOF-PET

State-of-the-art (SoA) electronic readout for silicon photomultiplier (SiPM)-based scintillation detectors that demonstrate experimental limits in achievable coincidence time resolution (CTR) leverage low noise, high frequency signal processing to facilitate a single photon time response that is near the limit of the SiPMs architecture. This readout strategy can optimally exploit fast luminescence and prompt photon populations, and promising measurements show detector concepts employing this readout can greatly advance PET detector CTR, relative to SoA in clinical systems. However, the technique employs power hungry components which make the electronics chain impractical for channel-dense time-of-flight (TOF)-PET detectors. We have developed and tested a low noise and high frequency readout circuit which is performant at low power and consists of discrete elements with small footprints, making it feasible for integration into TOF-PET detector prototypes. A 3 × 3 mm 2 Broadcom SiPM with this readout chain exhibited sub-100 ps single photon time resolution at 10 mW of power consumption, with a relatively minor performance degradation to 120 ± 2 ps FWHM at 5 mW. CTR measurements with 3 × 3 × 20 mm 3 LYSO and fast LGSO scintillators demonstrated 127 ± 3 ps and 113 ± 2 ps FWHM at optimal power operation and 133 ± 2 ps and 121 ± 3 ps CTR at 5 mW. BGO crystals 3 × 3 × 20 mm 3 in size show 271 ± 5 ps FWHM CTR (1174 ± 14 ps full-width-at-tenth-maximum (FWTM)) at optimal power dissipation and 289 ± 8 ps (1296 ± 33 ps FWTM) at 5 mW. The compact and low power readout topology that achieves this performance thereby offers a platform to greatly advance PET system CTR and also opportunities to provide high performance TOF-PET at reduced material cost.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A combined photoionization time-of-flight mass spectrometry and laser absorption spectrometry flash photolysis apparatus for simultaneous determination of reaction rates and product branching

In recent years, predictions of product branching for reactions of consequence to both combustion and atmospheric chemistry have outpaced validating experiments. An apparatus is described that aims to fill this void by combining several well-known experimental techniques into one: flash photolysis for radical generation, multiple-pass laser absorption spectrometry (LAS) for overall kinetics measurements, and time-resolved photoionization time-of-flight mass spectrometry (PI TOF-MS) for product branching quantification. The sensitivity of both the LAS and PI TOF-MS detection techniques is shown to be suitable for experiments with initial photolytically generated radical concentrations of ~1 × 10 12 molecules cm -3 . As it is fast (μs time resolution) and non-intrusive, LAS is preferred for accurate kinetics (time-dependence) measurements. By contrast, PI TOF-MS is preferred for product quantification because it provides a near-complete picture of the reactor composition in a single mass spectrum. The value of simultaneous LAS and PI TOF-MS detection is demonstrated for the chemically interesting phenyl radical + propene system.

47 OTHER INSTRUMENTATION↗

Cr(III) adsorption by cluster formation on boehmite nanoplates in highly alkaline solution

The development of advanced functional nanomaterials for selective adsorption in complex chemical environments requires partner studies of binding mechanisms. Motivated by observations of selective Cr(III) adsorption on boehmite nanoplates (?-AlOOH) in highly caustic multicomponent solutions of nuclear tank waste, here we unravel the adsorption mechanism in molecular detail. We examined Cr(III) adsorption to synthetic boehmite nanoplates in sodium hydroxide solutions up to 3 M, using a combination of XRD, Raman, XPS, STEM, EELS, HR-AFM, TOF-SIMS, Cr K-edge XANES/EXAFS, and EPR. Adsorption isotherms and kinetics were successfully fit to Langmuir and pseudo-second-order kinetic models, respectively, consistent with monotonic uptake of Cr(OH)4- monomers until saturation coverage of approximately half the aluminum surface site density. High resolution AFM revealed monolayer cluster self-assembly on the (010) basal surfaces with increasing Cr(III) loading, possessing a structural motif similar to ?-CrOOH, stabilized by corner-sharing Cr-O-Cr bonds and attached to the surface with edge-sharing Cr-O-Al bonds. The selective uptake appears related to short-range surface templating effects, with bridging metal connections likely enabled by hydroxyl anion ligand exchange reactions at the surface. Such a cluster formation mechanism, which stops short of more laterally extensive heteroepitaxy, could be a metal discrimination mechanism more prevalent than currently recognized.

Cui, Wenwen↗

Discovery of Nb hydride precipitates in superconducting qubits

We report the first evidence of the formation of niobium hydrides within niobium films on silicon substrates in superconducting qubits fabricated at Rigetti Computing. We combine complementary techniques including room and cryogenic temperature atomic scale high-resolution and scanning transmission electron microscopy (HR-TEM and STEM), atomic force microscopy (AFM), and the time-of-flight secondary ion mass spectroscopy (TOF-SIMS) to reveal the existence of the niobium hydride precipitates directly in the Rigetti chip areas. Electron diffraction and high-resolution transmission electron microscopy (HR-TEM) analyses are performed at room and cryogenic temperatures (~106 K) on superconducting qubit niobium film areas, and reveal the formation of three types of Nb hydride domains with different crystalline orientations and atomic structures. There is also variation in their size and morphology from small (~5 nm) irregular shape domains within the Nb grains to large (~10-100 nm) Nb grains fully converted to niobium hydride. As niobium hydrides are non-superconducting and can easily change in size and location upon different cooldowns to cryogenic temperatures, our findings highlight a new previously unknown source of decoherence in superconducting qubits, contributing to both quasiparticle and two-level system (TLS) losses, and offering a potential explanation for qubit performance changes upon cooldowns. A pathway to mitigate the formation of the Nb hydrides for superconducting qubit applications is also discussed.

Lee, Jaeyel↗

In Situ Measurements of Ammonia In Plumes Emitted From Wildfires And Agricultural Fires in the US

Emissions of trace gases and particles from fires have a major impact on climate, visibility, air quality, and public health. Biomass burning emissions include reactive nitrogen gases, among which ammonia (NH3) plays a prominent role. NH3 is a short-lived gas that acts as precursor for secondary inorganic aerosols. This process is still poorly constrained in downwind fire plumes. In summer 2019, NASA and NOAA carried out the joint airborne FIREX-AQ (Fire Influence on Regional to global Environments and Air Quality) mission over the continental US to sample plumes from wildfires and agricultural fires. On board the NASA DC-8, we used a modified PTR-ToF-MS instrument for measuring NH3 in situ and at high time resolution. Over the course of the mission, we collected a large set of NH3 data in plumes emitted from fires differing in fuel type and burning stage. Herein, we will present the measured NH3 emissions ratios and factors, compare them with the literature, and investigate the dependence of NH3 emissions on fuel type and burning conditions.

ammonia↗

Secondary Ion Mass Spectrometry Imaging of Tissues, Cells, and Microbial Systems

Mass spectrometry imaging (MSI) techniques are increasingly being utilized within many biological fields, including medicine, pathology, microbial ecology, and more. Of the MSI methods available, secondary ion mass spectrometry (SIMS) offers the highest lateral resolution of any technique. Moreover, SIMS versatility in the number of different operating modes and types of mass spectrometers available has made it an increasing popular method for bio-related measurements. Here, we discuss SIMS ability to image tissues, single cells, and microbes with a particular emphasis on the types chemical and spatial information that can be ascertained by the different types of SIMS instruments and methods. The recently developed Fourier transform ion cyclotron resonance (FTICR) SIMS located at PNNL is capable of generating molecular maps of tissues with an unprecedented mass resolving power and mass accuracy, with respect to SIMS measurements. ToF-SIMS can generate chemical maps, where detection of small molecules and fragments can be acquired with an order of magnitude better lateral resolution than the FTICR-SIMS. Furthermore, many of commercially available ToF-SIMS instruments are capable of depth profiling measurements, offering the ability to attain three-dimensional information of one’s sample. The NanoSIMS instrument offers the highest lateral resolution of any MSI method available. In practice, NanoSIMS regularly achieves sub-100 nm resolution of atomic and diatomic secondary ions within biological samples. The strengths of the different SIMS methods are more and more being leveraged in both multimodal-imaging endeavors that use complementary MSI techniques as well with optical, fluorescence, and force microscopy methods.

59 BASIC BIOLOGICAL SCIENCES↗

µRWELL-PICOSEC: The Development of Fast Timing Resistive Micro-WELL Detector Technology.

We present the development of a new concept of fast timing gaseous detector, the ?RWELL-PICOSEC detector based on Resistive Micro-Well (?RWELL) technology to provide timing resolution in the tens of picosecond range for application as time-of-flight (TOF) technology in the particle physics and medical instrumentation fields. The ?RWELL-PICOSEC technology combined a Cerenkov radiator for the generation of Cerenkov photons from high energy charged particles, a photocathode for the conversion of the produced photons into primary electrons and the ?RWELL foil for the multiplication of the electron to produce large signal on pad segmentation readout. The proof of concept of ?RWELL-PICOSEC is demonstrated with a small single-channel prototype and preliminary timing performance of 90 ps has been measured. Optimization study the amplification structure of ?RWELL-PICOSEC for the improvement of timing resolution is discussed and results on timing performance studies in beam at CERN are presented. The development of large area (100 mm × 100 mm) ?RWELL-PICOSEC and associated multichannel fast readout electronics and data acquisition system are also reported

Weisenberger, Andrew↗

Automated segmentation of cerebral vasculature with aneurysms in 3DRA and TOF-MRA using geodesic active regions: An evaluation study

Purpose: To evaluate the suitability of an improved version of an automatic segmentation method based on geodesic active regions (GAR) for segmenting cerebral vasculature with aneurysms from 3D x-ray reconstruction angiography (3DRA) and time of flight magnetic resonance angiography (TOF-MRA) images available in the clinical routine. Methods: Three aspects of the GAR method have been improved: execution time, robustness to variability in imaging protocols, and robustness to variability in image spatial resolutions. The improved GAR was retrospectively evaluated on images from patients containing intracranial aneurysms in the area of the Circle of Willis and imaged with two modalities: 3DRA and TOF-MRA. Images were obtained from two clinical centers, each using different imaging equipment. Evaluation included qualitative and quantitative analyses of the segmentation results on 20 images from 10 patients. The gold standard was built from 660 cross-sections (33 per image) of vessels and aneurysms, manually measured by interventional neuroradiologists. GAR has also been compared to an interactive segmentation method: isointensity surface extraction (ISE). In addition, since patients had been imaged with the two modalities, we performed an intermodality agreement analysis with respect to both the manual measurements and each of the two segmentation methods. Results: Both GAR and ISE differed from the gold standard within acceptable limits compared to the imaging resolution. GAR (ISE) had an average accuracy of 0.20 (0.24) mm for 3DRA and 0.27 (0.30) mm for TOF-MRA, and had a repeatability of 0.05 (0.20) mm. Compared to ISE, GAR had a lower qualitative error in the vessel region and a lower quantitative error in the aneurysm region. The repeatability of GAR was superior to manual measurements and ISE. The intermodality agreement was similar between GAR and the manual measurements. Conclusions: The improved GAR method outperformed ISE qualitatively as well as quantitatively and is suitable for segmenting 3DRA and TOF-MRA images from clinical routine.

60 APPLIED LIFE SCIENCES↗

Direct Characterization of Atomically Dispersed Catalysts: Nitrogen-Coordinated Ni Sites in Carbon-Based Materials for CO 2 Electroreduction

Metal, nitrogen-doped carbon materials have attracted interest as heterogenous catalysts that contain MN x active sites that are analogous to molecular catalysts. Of particular interest is Ni,N-doped carbon, a catalyst that is active for the electrochemical reduction of CO 2 to CO. Critical to the understanding of these materials is proof of single atomic sites and characterization of the environment surrounding the metal atom; however, directly probing this coordination remains challenging. This challenge is addressed in this study by combining scanning transmission electron microscopy (STEM), single atom electron energy loss spectroscopy (EELS), and time-of-flight secondary ion mass spectrometry (ToF-SIMS). Through STEM imaging, atomic dispersion of Ni in the carbon framework is confirmed and image analyses are utilized to give semiquantitative estimates of neighbor distance distributions and site densities of Ni atoms. Atomic resolution EELS demonstrates that N and Ni are colocated at the single Ni atom sites suggesting Ni–N coordination. ToF-SIMS reveals a distribution of NiN x C y - fragments that reflect the Ni–N bonding environments within Ni,N-doped carbon. The fragmentation from Ni,N-doped carbon is similar to Ni phthalocyanine, suggesting the existence of heterogenized, molecular-like NiN 4 active sites which motivates future studies that leverage insight from molecular catalysis design to develop next-generation heterogeneous catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutron Cross Sections for Next Generation Reactors: New Data from n_TOF

In 2002, an innovative neutron time-of-flight facility started operation at CERN: n_TOF. The main characteristics that make the new facility unique are the high instantaneous neutron flux, high resolution and wide energy range. Combined with state-of-the-art detectors and data acquisition system, these features have allowed to collect high accuracy neutron cross-section data on a variety of isotopes, many of which radioactive, of interest for Nuclear Astrophysics and for applications to advanced reactor technologies. A review of the most important results on capture and fission reactions obtained so far at n_TOF is presented, together with plans for new measurements related to nuclear industry.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New high-resolution electrostatic ion mass analyzer using time of flight

The design of a high-resolution ion-mass analyzer is described, which is based on an accurate measurement of the time of flight (TOF) of ions within a region configured to produce a harmonic potential. In this device, the TOF, which is independent of ion energy, is determined from a start pulse from secondary electrons produced when the ion passes through a thin carbon foil at the entrance of the TOF region and at a stop pulse from the ion striking a microchannel plate upon exciting the region. A laboratory prototype instrument called 'VMASS' was built and was tested at the Goddard Space Flight Center electrostatic accelerator, showing a good mass resolution of the instrument. Sensors of the VMASS type will form part of the WIND Solar Wind and Suprathermal Ion experiment, the Soho mission, and the Advanced Composition Explorer.