Search NASA⌕ Search

SEARCH · Search NASA

Results for “TRACE CONTAMINANT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Methane and Carbon Monoxide Concentration Dynamics of the International Space Station Cabin Atmosphere

Methane and carbon monoxide are gaseous contaminants commonly found in a crewed spacecraft’s cabin environment that are of interest to trace contaminant control equipment design. Generation sources include crew metabolism and equipment offgassing. Sources and generation rates of methane and carbon monoxide aboard the International Space Station (ISS) are examined. Cabin atmosphere concentration dynamics covering 19 years of ISS crewed operations are presented and correlation with octafluoropropane (Freon 218) concentration levels is analyzed.

Perry, Jay L.↗

Octafluoropropane Concentration Dynamics on Board the International Space Station

Since activating the International Space Station s (IS9 Service Module in November 2000, archival air quality samples have shown highly variable concentrations of octafluoropropane in the cabin. This variability has been directly linked to leakage from air conditioning systems on board the Service Module, Zvezda. While octafluoro- propane is not highly toxic, it presents a significant chal- lenge to the trace contaminant control systems. A discussion of octafluoropropane concentration dynamics is presented and the ability of on board trace contami- nant control systems to effectively remove octafluoropro- pane from the cabin atmosphere is assessed. Consideration is given to operational and logistics issues that may arise from octafluoropropane and other halo- carbon challenges to the contamination control systems as well as the potential for effecting cabin air quality.

Perry, J. L.↗

Monitoring spacecraft atmosphere contaminants by laser absorption spectroscopy

Data were obtained which will provide a test of the accuracy of the differential absorption method for trace contaminant detection in many-component gas mixtures. The necessary accurate absorption coefficient determinations were carried out for several gases; acetonitrile, 1,2-dichloroethane, Freon-113, furan, methyl ethyl ketone, and t-butyl alcohol. The absorption coefficients are displayed graphically. An opto-acoustic method was tested for measuring absorbance, similar to the system described by Dewey.

Steinfeld, J. I.↗

Visible-Light-Responsive Catalysts Using Quantum Dot-Modified TiO2 for Air and Water Purification

Photocatalysis, the oxidation or reduction of contaminants by light-activated catalysts, utilizing titanium dioxide (TiO2) as the catalytic substrate has been widely studied for trace contaminant control in both air and water applications. The interest in this process is due primarily to its low energy consumption and capacity for catalyst regeneration. Titanium dioxide requires ultraviolet light for activation due to its relatively large band gap energy of 3.2 eV. Traditionally, Hg-vapor fluorescent light sources are used in PCO reactors; however, the use of mercury precludes the use of this PCO technology in a spaceflight environment due to concerns over crew Hg exposure. The development of a visible-light responsive (VLR) TiO2-based catalyst would eliminate the concerns over mercury contamination. Further, VLR development would allow for the use of ambient visible solar radiation or highly efficient LEDs, both of which would make PCO approaches more efficient, flexible, economical, and safe. Though VLR catalyst development has been an active area of research for the past two decades, there are few commercially available VLR catalysts. Those VLR catalysts that are commercially available do not have adequate catalytic activity, in the visible region, to make them competitive with those operating under UV irradiation. This study was initiated to develop more effective VLR catalysts through a novel method in which quantum dots (QD) consisting of narrow band gap semiconductors (e.g., CdS, CdSe, PbS, ZnSe, etc.) are coupled to TiO2 via two preparation methods: 1) photodeposition and 2) mechanical alloying using a high-speed ball mill. A library of catalysts was developed and screened for gas and aqueous phase applications using ethanol and 4-chlorophenol as the target contaminants, respectively. Both target compounds are well studied in photocatalytic systems and served as model contaminants for this research. Synthesized catalysts were compared in terms of preparation method, nature of the quantum dots, and dosage of quantum dots.

visible light↗

Visible-Light Responsive Catalysts Using Quantum Dot-Modified TiO2 for Air and Water Purification

Photocatalysis, the oxidation or reduction of contaminants by light-activated catalysts, utilizing titanium dioxide (TiO2) as the catalytic substrate has been widely studied for trace contaminant control in both air and water applications. The interest in this process is due primarily to its low energy consumption and capacity for catalyst regeneration. Titanium dioxide requires ultraviolet light for activation due to its relatively large band gap energy of 3.2 eV. Traditionally, Hg-vapor fluorescent light sources are used in PCO reactors; however, the use of mercury precludes the use of this PCO technology in a spaceflight environment due to concerns over crew Hg exposure.

visible light↗

A Chemical Containment Model for the General Purpose Work Station

Contamination control is a critical safety requirement imposed on experiments flying on board the Spacelab. The General Purpose Work Station, a Spacelab support facility used for life sciences space flight experiments, is designed to remove volatile compounds from its internal airpath and thereby minimize contamination of the Spacelab. This is accomplished through the use of a large, multi-stage filter known as the Trace Contaminant Control System. Many experiments planned for the Spacelab require the use of toxic, volatile fixatives in order to preserve specimens prior to postflight analysis. The NASA-Ames Research Center SLS-2 payload, in particular, necessitated the use of several toxic, volatile compounds in order to accomplish the many inflight experiment objectives of this mission. A model was developed based on earlier theories and calculations which provides conservative predictions of the resultant concentrations of these compounds given various spill scenarios. This paper describes the development and application of this model.

Flippen, Alexis A.↗

Contaminant Permeation in the Ionomer-Membrane Water Processor (IWP) System

The Ionomer-membrane Water Processor (IWP) is a patented membrane-distillation based urine brine water recovery system. The unique properties of the IWP membrane pair limit contaminant permeation from the brine to the recovered water and purge gas. A paper study was conducted to predict volatile trace contaminant permeation in the IWP system. Testing of a large-scale IWP Engineering Development Unit (EDU) with urine brine pretreated with the International Space Station (ISS) pretreatment formulation was then conducted to collect air and water samples for quality analysis. Distillate water quality and purge air GC-MS results are presented and compared to predictions, along with implications for the IWP brine processing system.

Kelsey, Laura K.↗

Source Contaminant Control System Design, Operation, and Testing for the Trash Compaction and Processing System

The Trash Compaction and Processing System (TCPS) aims to reduce volume, biologically safen, physically stabilize, manage effluents, and recover resources from astronaut trash in the International Space Station (ISS). This process involves heating the trash to high temperatures, which in turn releases gaseous contaminants. Effluent management scenarios involve releasing these gases back to the ISS cabin after processing and/or directly venting these gases out to space via the Vacuum Exhaust System (VES). Concerns for recovering the gases back to cabin are crew health, safety, and spacecraft environmental impact. The Heat Melt Compactor (HMC) at NASA Ames Research Center (ARC) serves as a test system that supports TCPS development by conducting risk reduction activities associated with an ISS flight demonstration. Previous gas effluent studies were conducted on the HMC. The results consisted of contaminants from the trash exhaust to exceed Spacecraft Maximum Allowable Concentrations (SMAC), which are selected airborne contaminants that can elicit toxicity symptoms to crewmembers via exposure. The Source Contaminant Control System (SCCS) aims to reduce that risk by converting the contaminants into carbon dioxide (CO2) and water (H2O) vapor. The SCCS is composed of a carbon adsorbent bed, to avoid catalyst poisoning, and a catalytic oxidizer (CatOx), which promotes oxidation of the contaminants to CO2and H2O. In turn, the gases coming out of the SCCS should be compatible to the ISS cabin and systems such as the Trace Contaminant Control System (TCCS). Preparation for SCCS testing alongside the HMC Gen 3 are currently underway at ARC. The main objectives are to evaluate CatOx efficiency by CO2conversion and characterize effectiveness of removal by comparing contaminant results before and after CatOx. This paper will report on the SCCS design, operation, and testing with results.

TCPS↗

Development of Metal-impregnated Single Walled Carbon Nanotubes for Toxic Gas Contaminant Control in Advanced Life Support Systems

The success of physico-chemical waste processing and resource recovery technologies for life support application depends partly on the ability of gas clean-up systems to efficiently remove trace contaminants generated during the process with minimal use of expendables. Highly purified metal-impregnated carbon nanotubes promise superior performance over conventional approaches to gas clean-up due to their ability to direct the selective uptake gaseous species based both on the nanotube s controlled pore size, high surface area, and ordered chemical structure that allows functionalization and on the nanotube s effectiveness as a catalyst support material for toxic contaminants removal. We present results on the purification of single walled carbon nanotubes (SWCNT) and efforts at metal impregnation of the SWCNT's.

Cinke, Martin↗

Development of Metal-impregnated Single Walled Carbon Nanotubes for Toxic Gas Contaminant Control in Advanced Life Support Systems

The success of physico-chemical waste processing and resource recovery technologies for life support application depends partly on the ability of gas clean-up systems to efficiently remove trace contaminants generated during the process with minimal use of expendables. Carbon nanotubes promise superior performance over conventional approaches to gas clean-up due to their ability to direct the selective uptake of gaseous species based on their controlled pore size, high surface area, ordered chemical structure that allows functionalization and their effectiveness also as catalyst support materials for toxic gas conversion. We present results and findings from a preliminary study on the effectiveness of metal impregnated single walled nanotubes as catalyst/catalyst support materials for toxic gas contaminate control. The study included the purification of single walled nanotubes, the catalyst impregnation of the purified nanotubes, the experimental characterization of the surface properties of purified single walled nanotubes and the characterization of physisorption and chemisorption of uptake molecules.

Pisharody, Suresh A.↗

Source Contaminant Control System Design, Operation, and Testing for the Trash Compaction and Processing System

The Trash Compaction and Processing System (TCPS) aims to reduce volume, biologically safen, physically stabilize, manage effluents, and recover resources from astronaut trash in the International Space Station (ISS). This process involves heating the trash to high temperatures, which in turn releases gaseous contaminants. Effluent management scenarios involve releasing these gases back to the ISS cabin after processing and/or directly venting these gases out to space via the Vacuum Exhaust System (VES). Concerns for recovering the gases back to cabin are crew health, safety, and spacecraft environmental impact. The Heat Melt Compactor (HMC) at NASA Ames Research Center (ARC) serves as a test system that supports TCPS development by conducting risk reduction activities associated with an ISS flight demonstration. Previous gas effluent studies were conducted on the HMC. The results consisted of contaminants from the trash exhaust to exceed Spacecraft Maximum Allowable Concentrations (SMAC), which are selected airborne contaminants that can elicit toxicity symptoms to crewmembers via exposure. The Source Contaminant Control System (SCCS) aims to reduce that risk by converting the contaminants into carbon dioxide (CO2) and water (H2O) vapor. The SCCS is composed of a carbon adsorbent bed, to avoid catalyst poisoning, and a catalytic oxidizer (CatOx), which promotes oxidation of the contaminants to CO2 and H2O. In turn, the gases coming out of the SCCS should be compatible to the ISS cabin and systems such as the Trace Contaminant Control System (TCCS). Preparation for SCCS testing alongside the HMC Gen 3 are currently underway at ARC. The main objectives are to evaluate CatOx efficiency by CO2 conversion and characterize effectiveness of removal by comparing contaminant results before and after CatOx. This paper will report on the SCCS design, operation, and testing with results.

Janine Young↗

Contaminant Interferences with SIMS Analyses of Microparticle Impactor Residues on LDEF Surfaces

Elemental analyses of impactor residues on high purity surface exposed to the low earth orbit (LEO) environment for 5.8 years on Long Duration Exposure Facility (LDEF) has revealed several probable sources for microparticles at this altitude, including natural micrometeorites and manmade debris ranging from paint pigments to bits of stainless steel. A myriad of contamination interferences were identified and their effects on impactor debris identification mitigated during the course of this study. These interferences included pre-, post-, and in-flight deposited particulate surface contaminants, as well as indigenous heterogeneous material contaminants. Non-flight contaminants traced to human origins, including spittle and skin oils, contributed significant levels of alkali-rich carbonaceous interferences. A ubiquitous layer of in-flight deposited silicaceous contamination varied in thickness with location on LDEF and proximity to active electrical fields. In-flight deposited (low velocity) contaminants included urine droplets and bits of metal film from eroded thermal blankets.

Simon, C. G.↗

Secondary ion mass spectrometry (SIMS) analysis of hypervelocity microparticle impact sites on LDEF surfaces

Two dimensional elemental ion maps have been recorded for hundreds of microparticle impact sites and contamination features on LDEF surfaces. Since the majority of the analyzed surfaces were metal-oxide-silicon (MOS) impact detectors from the Interplanetary Dust Experiment, a series of 'standard' and 'blank' analyses of these surfaces are included. Hypervelocity impacts of forsterite olivine microparticles on activated flight sensors served as standards while stylus and pulsed laser simulated 'impacts' served as analytical blanks. Results showed that despite serious contamination issues, impactor residues can be identified in greater than 1/3 of the impact sites. While aluminum oxide particles could not be detected on aluminum surfaces, they were detected on germanium surfaces from row 12. Remnants of manmade debris impactors consisting of paint chips and bits of metal were identified on surfaces from LDEF Rows 3 (west or trailing side), 6 (south), 9 (ram or leading side), 12 (north) and the space end. Higher than expected ratios of manmade microparticle impacts to total microparticle impacts were found on the space end and the trailing side. These results were consistent with time-tagged and time-segregated microparticle impact data from the IDE and other LDEF experiments. A myriad of contamination interferences were identified and their effects on impactor debris identification mitigated during the course of this study. These interferences include pre-, post and inflight deposited surface contaminants as well as indigenous heterogeneous material contaminants. Non-flight contaminations traced to human origins, including spittle and skin oils, contributed significant levels of alkali-rich carbonaceous interferences. A ubiquitous layer of in-flight deposited silicaceous contamination varied in thickness with location on LDEF, even on a micro scale. In-flight deposited (low velocity) contaminants include urine droplets and bits of metal film from eroded thermal blankets.

Simon, C. G.↗

Space Station atmospheric monitoring systems

A technology assessment study on atmospheric monitoring systems was performed by Battelle Columbus Division for the National Aeronautics and Space Administration's John F. Kennedy Space Center under Contract No. NAS 10-11033. In this assessment, the objective was to identify, analyze, and recommend systems to sample and measure Space Station atmospheric contaminants and identify where additional research and technology advancements were required. To achieve this objective, it was necessary to define atmospheric monitoring requirements and to assess the state of the art and advanced technology and systems for technical and operational compatibility with monitoring goals. Three technical tasks were defined to support these needs: Definition of Monitoring Requirements, Assessment of Sampling and Analytical Technology, and Technology Screening and Recommendations. Based on the analysis, the principal candidates recommended for development at the Space Station's initial operational capability were: (1) long-path Fourier transform infrared for rapid detection of high-risk contamination incidences, and (2) gas chromatography/mass spectrometry utilizing mass selective detection (or ion-trap) technologies for detailed monitoring of extended crew exposure to low level (ppbv) contamination. The development of a gas chromatography/mass spectrometry/matrix isolation-Fourier transform infrared system was recommended as part of the long range program of upgrading Space Station trace-contaminant monitoring needs.

Air Pollution, Indoor/analysis↗

Updated Analysis of the Source Contaminant Control System (SCCS) for the Trash Compaction and Processing System (TCPS)

The Trash Compaction and Processing System (TCPS) aims to reduce volume, biologically safen, physically stabilize, manage effluents, and recover resources from astronaut trash in the International Space Station (ISS). This process involves heating the trash to high temperatures, which in turn releases gaseous contaminants. A Source Contaminant Control System (SCCS) is planned to be implemented within the TCPS to convert these contaminants into carbon dioxide (CO 2 ) and water (H 2 O) vapor. The SCCS is composed of a carbon adsorbent bed, to avoid catalyst poisoning, and a catalytic oxidizer (CatOx), which promotes oxidation of the contaminants to CO 2 and H 2 O. In turn, the gases coming out of the SCCS should be compatible to the ISS cabin and systems such as the Trace Contaminant Control System (TCCS). This paper will individually evaluate the carbon bed and CatOx to understand what components the carbon bed removes and what contaminants are converted in the CatOx. Overall, this is an updated analysis of the SCCS design, operation, testing with results, and lessons learned.

Janine Criselda Young↗

Global sensing of gaseous and aerosol trace species using automated instrumentation on 747 airliners

The Global Atmospheric Sampling Program (GASP) is collecting and analyzing data on gaseous and aerosol trace contaminants in the upper troposphere and lower stratosphere. Measurements are obtained from automated systems installed on four 747 airliners flying global air routes. Improved instruments and analysis techniques are providing an expanding data base for trace species including ozone, carbon monoxide, water vapor, condensation nuclei, and mass concentration of sulfates and nitrates. Simultaneous measurements of several trace species obtained frequently can be used to identify the source of the air mass as being typically tropospheric or stratospheric.

Perkins, P. J.↗

Sustainability of the Catalytic Activity of a Silica-Titania Composite (STC) for Long-Term Indoor Air Quality Control

TiO2-assisted photocatalytic oxidation (PCO) is an emerging technology for indoor air quality control and is also being evaluated as an alternative trace contaminant control technology for crew habitats in space exploration. Though there exists a vast range of literature on the development of photocatalysts and associated reactor systems, including catalyst performance and performance-influencing factors, the critical question of whether photocatalysts can sustain their initial catalytic activity over an extended period of operation has not been adequately addressed. For a catalyst to effectively serve as an air quality control product, it must be rugged enough to withstand exposure to a multitude of low concentration volatile organic compounds (VOCs) over long periods of time with minimal loss of activity. The objective of this study was to determine the functional lifetime of a promising photocatalyst - the silica-titania composite (STC) from Sol Gel Solutions, LLC in a real-world scenario. A bench-scale STC-packed annular reactor under continuous irradiation by a UV-A fluorescent black-light blue lamp ((lambda)max = 365 nm) was exposed to laboratory air continuously at an apparent contact time of 0.27 sand challenged with a known concentration of ethanol periodically to assess any changes in catalytic activity. Laboratory air was also episodically spiked with halocarbons (e.g., octafluoropropane), organosulfur compounds (e.g., sulfur hexafluoride), and organosilicons (e.g., siloxanes) to simulate accidental releases or leaks of such VOCs. Total organic carbon (TOC) loading and contaminant profiles of the laboratory air were also monitored. Changes in STC photocatalytic performance were evaluated using the ethanol mineralization rate, mineralization efficiency, and oxidation intermediate (acetaldehyde) formation. Results provide insights to any potential catalyst poisoning by trace halocarbons and organosulfur compounds.

Coutts, Janelle L.↗