Search NASA⌕ Search

SEARCH · Search NASA

Results for “Temperature Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Surface crystalline carbon temperature sensor

The described sensor has been used to measure small temperature changes in investigations related to the study of the properties of superfluid helium under zero-gravity conditions. The sensor requirements included high sensitivity, rapid response, small size, reproducibility, and ease of application to a test surface. In the preparation of the sensor a thin film of a commercially available carbon colloidal suspension is deposited on a substrate which must be electrically insulated or be covered with an insulating layer.

Petrac, D.↗

Platinum-Resistor Differential Temperature Sensor

Platinum resistance elements used in bridge circuit for measuring temperature difference between two flowing liquids. Temperature errors with circuit are less than 0.01 degrees C over range of 100 degrees C.

Kolbly, R. B.↗

Fiber Bragg Grating Filter High Temperature Sensors

We present a scaled-down method for determining high temperatures using fiber-based Bragg gratings. Bragg gratings are distributed along the length of the optical fiber, and have high reflectivities whenever the optical wavelength is twice the grating spacing. These spatially distinct Bragg regions (located in the core of a fiber) are sensitive to local temperature changes. Since these fibers are silica-based they are easily affected by localized changes in temperature, which results in changes to both the grating spacing and the wavelength reflectivity. We exploit the shift in wavelength reflectivity to measure the change in the local temperature. Note that the Bragg region (sensing area) is some distance away from where the temperature is being measured. This is done so that we can measure temperatures that are much higher than the damage threshold of the fiber. We do this by affixing the fiber with the Bragg sensor to a material with a well-known coefficient of thermal expansion, and model the heat gradient from the region of interest to the actual sensor. The research described in this paper will culminate in a working device as well as be the second portion of a publication pending submission to Optics Letters.

Lyons, Donald R.↗

Optical cross beam field tests at ESSA Haswell Field site, October 1969

A series of tests with both the visible and IR optical cross beam systems was made at the Haswell, Colorado, Field Site of ESSA. This memorandum covers only the details of the test setup and runs. A joint field test program was undertaken by ESSA at a 164 meter (500 foot) meteorological tower. The tower was instrumented with wind sensors, temperature sensors, temperature sensors, fluctuating wind and temperature sensors and humidity sensors. The sensors were located at three elevations: 42, 192 and 162 meters. A movable elevator was also instrumented and could be positioned at any desired location along the tower height. The main object of the cross beam studies was to compare the visible and IR systems. The instruments were also arranged so that direct comparison with the sensors on the tower can be made.

Sandborn, V. A.↗

Drexel University Temperature Sensors

This document summarizes background information and presents results related to temperature measurements in the Advanced Test Reactor (ATR) National Scientific User Facility (NSUF) Drexel University Project 31091 irradiation. The objective of this test was to assess the radiation performance of new ceramic materials for advanced reactor applications. Accordingly, irradiations of transition metal carbides and nitrides were performed using the Hydraulic Shuttle Irradiation System (HSIS) in the B-7 position and in static capsules inserted into the A-3 and East Flux Trap Position 5 locations of the ATR.

36 MATERIALS SCIENCE↗

University of Illinois Temperature Sensors

This document summarizes background information and presents results related to temperature measurements in the Advanced Test Reactor (ATR) National Scientific User Facility (NSUF) University of Illinois Project 29609 irradiation. The objective of this test was to assess the radiation performance of ferritic alloys for advanced reactor applications. The FeCr-based alloy system is considered the lead alloy system for a variety of advanced reactor components and applications. Irradiations of FeCr alloy samples were performed using the Hydraulic Shuttle Irradiation System (HSIS) in the B-7 position and in a static capsule in the A-11 position of the ATR.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Metal 3D Printing of Low-NOX Fuel Injectors with Integrated Temperature Sensors (Final Technical Report)

This technical report presents the exploration of design and prototyping of an Oxy-fuel injector with integrated temperature sensing capabilities using Additive Manufacturing (AM) technology. The AM process has proven itself as a viable method to fabricate complex shapes for custom-designed metallic components rapidly. The lack of assembly requirements and the virtually unlimited geometrical complexity renders the AM process particularly attractive for fabricating complex energy system components. The unique layer-by-layer fabrication technique allows the embedding of sensors within complex components early in the design process. Sensors can be embedded (without post-production component modifications) in AM-fabricated components through two distinct processes: Stop and Go or Post-Integration. The Stop and Go fabrication process allows sensor placement within a cavity during fabrication; where the process is allowed to continue upon sensor placement. Post-integration process supports selective build of customized compartments for sensors within the part. The Stop and Go process requires an extremely accurate re-alignment of the powder-bed during the restart process. Additionally, metallization and shorting of sensors due to a considerably high temperature of the AM process creates significant fabrication challenges and limit the types of sensors that can be embedded. The Post-Integration of sensors is a practical alternative for components that can be effectively designed and fabricated with pre-built complex sensor compartments without the need for post-production component modifications. The proposed effort aimed at exploring the fabrication of an oxy-fuel injector designed for high-pressure Oxy-Combustion applications (Combustor for Directly Heated Supercritical Power Cycle) with integrated temperature measurement capabilities using the AM technique. Since the current design methodology of injectors is based on conventional fabrication techniques (e.g., multi-step machining and welding processes), a new paradigm of design methodology needs to be developed for their adaptation in the AM fabrication process. One of the most challenging issues addressed in powder bed fusion is the removal of powder from internal channels/cavities as the powder to be removed has been lightly sintered during the fabrication process. In this research, a major task has been assigned to developing and evaluating powder removal techniques that will ultimately be used when removing sintered powder from cavities/channels used for sensor placement. Achieving thorough powder removal will permit the incorporation of intricate cavities, integrated fasteners, or other novel features to incorporate sensors into parts directly post-fabrication – allowing for the novel, AM-based design practices to be developed and employ for sensor integration. The designed injector was initially tested at atmospheric conditions to review its successful operation. The tests were carried out for different firing inputs; with a minimum of 55 kW and a maximum of 275 kW. Later tests were carried out for pressurized conditions between 82 kW to 275 kW firing input. A pressure of 16.35bar was observed in the combustion chamber pressure during the pressurized test of 275 kW firing input; test duration was 15 seconds. Integrated thermocouples within the injector provided temperature data for test operations. The data revealed during the atmospheric condition the injector temperature is almost unaffected by the combustion. However, during the pressurized condition, the injector temperature rapidly up to 205°C within 15 seconds; at a 275 kW firing input.

42 ENGINEERING↗

Thermophysical Properties Along Curiosity's Traverse in Gale Crater, Mars, Derived from the REMS Ground Temperature Sensor

The REMS instrument onboard the Mars Science Laboratory rover, Curiosity, has measured ground temperature nearly continuously at hourly intervals for two Mars years. Coverage of the entire diurnal cycle at 1 Hz is available every few martian days. We compare these measurements with predictions of surface atmosphere thermal models to derive the apparent thermal inertia and thermally derived albedo along the rovers traverse after accounting for the radiative effects of atmospheric water ice during fall and winter, as is necessary to match the measured seasonal trend. The REMS measurements can distinguish between active sand, other loose materials, mudstone, and sandstone based on their thermophysical properties. However, the apparent thermal inertias of bedrock dominated surfaces [approx. 350-550 J m(exp. -2) K(exp. -1 s(exp. -1/2 )] are lower than expected. We use rover imagery and the detailed shape of the diurnal ground temperature curve to explore whether lateral or vertical heterogeneity in the surface materials within the sensor footprint might explain the low inertias. We find that the bedrock component of the surface can have a thermal inertia as high as 650-1700 J m(exp. -2) K(exp. -1) s(exp. -1/2) for mudstone sites and approx. 700 J m(exp. -2) K(exp. -1) s(exp. - 1/2) for sandstone sites in models runs that include lateral and vertical mixing. Although the results of our forward modeling approach may be non-unique, they demonstrate the potential to extract information about lateral and vertical variations in thermophysical properties from temporally resolved measurements of ground temperature.

Vasavada, Ashwin R.↗

Thin-film temperature sensor.

A new device has been developed for sensing small and rapid temperature changes accompanying biochemical reactions. The active element consists of an evaporated thin-film capacitor having a relatively strong temperature dependence. This dependence is derived from electron trapping effects in the thin amorphous dielectric film. A voltage output of at least 50 mV/deg can be obtained prior to amplification by using a resonant ac bridge circuit operating at 100 kHz. The corresponding noise output for a 10 kHz bandwidth can with an optimum circuit be as low as 4 microvolts. Therefore, the minimum detectable temperature change would be 80 microdegrees at 10 kHz. Rapid thermal response is assured by supporting the thin-film capacitor on a thin anodic tantalum oxide film suspended across an electrolytically etched window in a tantalum foil.

Maserjian, J.↗

All-Ceramic Passive Wireless Temperature Sensor Realized by Tin-Doped Indium Oxide (ITO) Electrodes for Harsh Environment Applications

In this work, an all-ceramic passive wireless inductor–capacitor (LC) resonator was presented for stable temperature sensing up to 1200 °C in air. Instead of using conventional metallic electrodes, the LC resonators are modeled and fabricated with thermally stable and highly electroconductive ceramic oxide. The LC resonator was modeled in ANSYS HFSS to operate in a low-frequency region (50 MHz) within 50 × 50 mm geometry using the actual material properties of the circuit elements. The LC resonator was composed of a parallel plate capacitor coupled with a planar inductor deposited on an Al2O3 substrate using screen-printing, and the ceramic pattern was sintered at 1250 °C for 4 h in an ambient atmosphere. The sensitivity (average change in resonant frequency with respect to temperature) from 200–1200 °C was ~170 kHz/°C. The temperature-dependent electrical conductivity of the tin-doped indium oxide (ITO, 10% SnO2 doping) on the quality factor showed an increase of Qf from 36 to 43 between 200 °C and 1200 °C. The proposed ITO electrodes displayed improved sensitivity and quality factor at elevated temperatures, proving them to be an excellent candidate for temperature sensing in harsh environments. The microstructural analysis of the co-sintered LC resonator was performed using a scanning electron microscope (SEM) which showed that there are no cross-sectional and topographical defects after several thermal treatments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Doppler Wind Temperature Sensor (DWTS) Flight Evaluation and Experiments (TES-16, 17)

The Doppler Wind and Temperature Sounder instrument (DWTS), developed by Global Atmospheric Technologies and Sciences (GATS), is a simple but powerful tool that has the potential to become a new window through which to study the dynamics of the upper atmosphere. Based around a defense-grade infrared camera peering through a static gas cell used as a scanning spectral filter, the DWTS instrument infers wind velocities and kinetic temperatures through the stratosphere and lower thermosphere. The DWTS achieves this scanning by measuring the induced Doppler shift and Doppler broadening of emissions as they pass through the DWTS field of view (Gordley, et al., 2011). The DWTS holds promise in improving accuracy in weather determination , and the core technology can be adapted to study other planetary atmospheres. In partnership with GATS, NOAA, and other collaborators, NASA Ames and the Nano Orbital Workshop group have been working to evaluate the DWTS instrument on orbit and optimize it as a flexible nanosatellite payload. The first mission selected for DWTS evaluation is preparing for flight in early 2024, which will be followed by a more capable science mission in 2025, with both missions being part of the TES-n/NOW heritage flight series. The first rapid technology demonstration flight, TES-16/DWTS-A, will demonstrate a single DWTS instrument in an approximately 2U payload volume with the imaging aperture perpendicular to the flight velocity vector. With an estimated power consumption of 50 watts, supplied via a custom NOW-designed DC-DC converter, the instrument will maintain the imaging sensor plane at 80K during instrument evaluation periods using an integrated pulse-tube cryocooler. Data from DWTS will be captured and processed via a NOW-designed custom data interface unit before being transmitted via S-band radio back to select ground stations, with instrument command and control operated via L-band global-coverage radio. The subsequent TES-17/DWTS-B mission will be a dedicated science mission to obtain full altitude coverage from 20 to 200 km during both day and night, all from a single small-satellite equipped with three DWTS instruments, each hosting a different gas cell chemistry. The intention of this flight series, and one of NASA’s interests in this instrument, is to advance a Martian atmospheric instrument (Colaprete, Gordley, et al) which, if successful, would greatly further understanding of Martian atmospheric behavior. The proposed paper will review the flight series in detail, including challenges facing the TES-16 flight tests and the projected challenges and application to Mars study. Additional detail regarding the possible applications of a Cognitive Communication technique in current flight development by NOW collaborators at the NASA Glenn Research Center will also be discussed, including the implications of using an automated User Initiated Service (UIS) protocol to maximize the data collected per orbit.

nanosatellite↗

High Fluence Active Irradiation and Combined Effects Testing of Sapphire Optical Fiber Distributed Temperature Sensors [Slides]

All objectives have been completed. Heated irradiation indicates potential for sapphire fiber-based sensors to be used in extreme environments beyond silica fiber temperature limits. Sapphire optical fiber may not be appropriate for high fluence applications. Clad sapphire optical fibers have a temperature-dependent attenuation that has not been observed in unclad sapphire. With the appropriate pre-treatments and data post-processing, sapphire optical fiber has the potential to serve as a distributed sensor up to 1700ºC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Auger electron spectroscopy study of oxidation of a PdCr alloy used for high-temperature sensors

A Pd-13 wt. percent Cr solid solution is a promising high-temperature strain gage alloy. In bulk form it has a number of properties that are desirable in a resistance strain gage material, such as a linear electrical resistance versus temperature curve to 1000 C and stable electrical resistance in air at 1000 C. However, unprotected fine wire gages fabricated from this alloy perform well only to 600 C. At higher temperatures severe oxidation degrades their electrical performance. In this work Auger electron spectroscopy was used to study the oxidation chemistry of the alloy wires and ribbons. Results indicate that the oxidation is caused by a complex mechanism that is not yet fully understood. As expected, during oxidation, a layer of chromium oxide is formed. This layer, however, forms beneath a layer of metallic palladium. The results of this study have increased the understanding of the oxidation mechanism of Pd-13 wt. percent Cr.

Boyd, Darwin L.↗

Ultra-High Temperature Sensors Based on Optical Property

In this program, Nuonics, Inc. has studied the fundamentals of a new Silicon Carbide (SiC) materials-based optical sensor technology suited for extreme environments of coal-fired engines in power production. The program explored how SiC could be used for sensing temperature, pressure, and potential gas species in a gas turbine environment. The program successfully demonstrated the optical designs, signal processing and experimental data for enabling both temperature and pressure sensing using SiC materials. The program via its sub-contractors also explored gas species sensing using SiC, in this case, no clear commercially deployable method was proven. Extensive temperature and pressure measurement data using the proposed SiC sensors was acquired to 1000 deg-C and 40 atms, respectively. Importantly, a first time packaged all-SiC probe design was successfully operated in a Siemens industrial turbine rig facility with the probe surviving the harsh chemical, pressure, and temperature environment during 28 days of test operations. The probe also survived a 1600 deg-C thermal shock test using an industrial flame.

01 COAL, LIGNITE, AND PEAT↗

Active Wireless Temperature Sensors for Aerospace Thermal Protection Systems

Health diagnostics is an area where major improvements have been identified for potential implementation into the design of new reusable launch vehicles in order to reduce life-cycle costs, to increase safety margins, and to improve mission reliability. NASA Ames is leading the effort to advance inspection and health management technologies for thermal protection systems. This paper summarizes a joint project between NASA Ames and Korteks to develop active wireless sensors that can be embedded in the thermal protection system to monitor sub-surface temperature histories. These devices are thermocouples integrated with radio-frequency identification circuitry to enable acquisition and non-contact communication of temperature data through aerospace thermal protection materials. Two generations of prototype sensors are discussed. The advanced prototype collects data from three type-k thermocouples attached to a 2.54-cm square integrated circuit.

Milos, Frank S.↗

Thin-film temperature sensors for gas turbine engines Problems and prospects

The erosion and corrosion of thermocouples used to measure the temperature in turbine engines are studied. Structural and metallurgical interactions and instabilities at thermocouple interfaces are analyzed. Consideration is given to the adhesion, dielectric quality, surface topography, and hardness of the thermal oxides; it is observed that the structural and thermoelectric stability of thin-film thermocouple elements depends on adhesion, surface topography, and dielectric strength. The electrical conductivity and impurity content of the oxide scale are evaluated. Methods for improving the adhesion of thermocouples on the alumina surfaces are described. Compositional inhomogeneities in the sensors and contamination of the thermocouple elements are examined. The fabrication of the thermocouples is discussed. It is noted that Al2O3 and Si3N4 are useful for developing stable thermocouple elements on the surface of the blades and vanes.

Budhani, R. C.↗

Thermogravimetric study of oxidation of a PdCr alloy used for high-temperature sensors

In this study, the oxidation of Pd-13 weight percent Cr, a candidate alloy for high-temperature strain gages, was investigated by thermogravimetry. Although the bulk alloy exhibits linear electrical resistivity versus temperature and stable resistivity at elevated temperatures, problems attributed to oxidation occur when this material is fabricated into strain gages. In this work, isothermal thermogravimetry (TG) was used to study the oxidation kinetics. Results indicate that the oxidation of Pd-13 weight percent Cr was approximately parabolic in time at 600 C but exhibited greater passivation from 700 to 900 C. At 1100 C, the oxidation rate again increased.

Boyd, Darwin L.↗

Development of Filled-Skutterudite Based Thermopile for High Temperature Sensors for Space and Terrestrial Applications

The Thermal Energy Conversion Technologies Group at the Jet Propulsion Laboratory has been pursuing the development of thermopiles capable of higher temperature operation in support of terrestrial and space sensing applications in extreme environments. The next-generation sensor technology would rely on filled skutterudite (SKD) compounds, the same materials currently being considered for use in the enhanced Multi-Mission Radioisotope Thermoelectric Generator (eMMRTG). We report on the design, development and fabrication of SKD-based prototype thermopile devices. The beginning-of-life (BOL) experimental and predicted performance of the SKD-based prototype thermopile in terms of electrical resistance, output voltage, current, power output and efficiency in the 423 to 723 K operating temperature range is reported and discussed.

Smith, Kevin L.↗